메뉴 건너뛰기




Volumn 44, Issue 11, 2009, Pages 691-696

Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography techniques and initial clinical results

Author keywords

Computed tomography (ct); Metal artifact reduction; Multi slice helical ct

Indexed keywords

ARTICLE; ARTIFACT REDUCTION; HIP PROSTHESIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; METAL IMPLANTATION; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; ABDOMINAL RADIOGRAPHY; ALGORITHM; ARTIFACT; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED TOMOGRAPHY; EVALUATION; HUMAN; METHODOLOGY; PILOT STUDY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 73949111106     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e3181b0a2f9     Document Type: Article
Times cited : (87)

References (21)
  • 1
    • 0036798793 scopus 로고    scopus 로고
    • Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction
    • Williamson JF, Whiting BR, Benae J, et al. Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction. Mad. Phys. 2002:29:2404-2418.
    • (2002) Mad. Phys. , vol.29 , pp. 2404-2418
    • Williamson, J.F.1    Whiting, B.R.2    Benae, J.3
  • 2
    • 34447339156 scopus 로고    scopus 로고
    • Correction of CT artifacts and its influence on Monte Carlo dose calculations
    • DOI 10.1118/1.2736777
    • Bazalova M, Beaulieu L, Palefsky S, et al. Correction of CT artifacts and its influence on Monte Carlo dose calculations. Med Phys. 2007; 34:2119-2132. (Pubitemid 47055747)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 2119-2132
    • Bazalova, M.1    Beaulieu, L.2    Palefsky, S.3    Verhaegen, F.4
  • 3
    • 0031794571 scopus 로고    scopus 로고
    • Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise
    • DOI 10.1118/1.598410
    • Hsieh, J. Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise. Med Phys. 1998;25:2139 2147. (Pubitemid 28530103)
    • (1998) Medical Physics , vol.25 , Issue.11 , pp. 2139-2147
    • Hsieh, J.1
  • 4
    • 0035052748 scopus 로고    scopus 로고
    • Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT
    • DOI 10.1118/1.1358303
    • Kachelriess M. Watzke O, Kalender WA. Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice. and cone-beam CT. Med Phys. 2001:28:475-490. (Pubitemid 32323299)
    • (2001) Medical Physics , vol.28 , Issue.4 , pp. 475-490
    • Kachelriess, M.1    Watzke, O.2    Kalender, W.A.3
  • 6
    • 0034206972 scopus 로고    scopus 로고
    • Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm
    • De Mam B. Nuyts J, Dupont P, et al. Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm. IEEE Trans Nucl Sci. 2000:47:977 981. (Pubitemid 30912575)
    • (2000) IEEE Transactions on Nuclear Science , vol.47 , pp. 977-981
    • De Man, B.1    Nuyts, J.2    Dupont, P.3    Marcha, G.4    Suetens, P.5
  • 7
    • 0035491479 scopus 로고    scopus 로고
    • An iterative maximum-likelihood polychromatic algorithm for CT
    • De Man B, Nuyts J, Dupont P, et al. An iterative maximum-likelihood polychromatic algorithm for CT. IEEE Trans Med Imaging. 200l;20: 999-1008.
    • (2001) IEEE Trans Med Imaging. , vol.20 , pp. 999-1008
    • De Man, B.1    Nuyts, J.2    Dupont, P.3
  • 8
    • 0034351113 scopus 로고    scopus 로고
    • X-ray CT metal artifact reduction using wavelets: Arm application for imaging total hip prostheses
    • Zhao SY. Robcrston DD, Wang G, el al. X-ray CT metal artifact reduction using wavelets: arm application for imaging total hip prostheses. IEEE Trans Med Imaging. 2000;19:1238-1247.
    • (2000) IEEE Trans Med Imaging. , vol.19 , pp. 1238-1247
    • Zhao, S.Y.1    Robcrston, D.D.2    Wang, G.3    Al, E.4
  • 9
    • 0019839830 scopus 로고
    • An algorithm for the reduction of metal clip artifacts in CT reconstructions
    • Glover GH, PeIc NJ. An algorithm for the reduction of metal clip artifacts in CT reconstructions. Med Phys. 1981:8:799-807.
    • (1981) Med Phys. , vol.8 , pp. 799-807
    • Glover, G.H.1    Peic, N.J.2
  • 10
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • Kalender WA, Hebel R, Ebersberger J. Reduction of CT artifacts caused by metallic implanls. Radiology. 1987;164:576-577. (Pubitemid 17097989)
    • (1987) Radiology , vol.164 , Issue.2 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.3
  • 11
    • 2542496945 scopus 로고    scopus 로고
    • A pragmatic approach to metal artifact reduction in CT: Merging of metal artifact reduced images
    • DOI 10.1007/s00330-004-2263-y
    • Watzke O, Kalender WA. A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images. Eur Radiol. 2004;14:849-856. (Pubitemid 38678906)
    • (2004) European Radiology , vol.14 , Issue.5 , pp. 849-856
    • Watzke, O.1    Kalender, W.A.2
  • 12
    • 12744273446 scopus 로고    scopus 로고
    • X-ray CT high-density artifact suppression in the presence of bones
    • Wei J, Chen L, Sandison GA, et al. X-ray CT high-density artifact suppression in the presence of bones. Phys Med Biol. 2004:49:5407-5418.
    • (2004) Phys Med Biol. , vol.49 , pp. 5407-5418
    • Wei, J.1    Chen, L.2    Sandison, G.A.3
  • 13
    • 33746633331 scopus 로고    scopus 로고
    • Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
    • DOI 10.1118/1.2218062
    • Bal M. Spies L. Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. Med Phys. 2006;33:2852 2859. (Pubitemid 44154556)
    • (2006) Medical Physics , vol.33 , Issue.8 , pp. 2852-2859
    • Bal, M.1    Spies, L.2
  • 15
    • 21244471813 scopus 로고    scopus 로고
    • An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: Experimental and clinical studies
    • DOI 10.1016/j.ijrobp.2005.02.052, PII S0360301605004219
    • Yazdi M. Gingras L. Beaulieu L. An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies. Int J Radial Oncol Biol Phys. 2005;62:1224-1231. (Pubitemid 40884438)
    • (2005) International Journal of Radiation Oncology Biology Physics , vol.62 , Issue.4 , pp. 1224-1231
    • Yazdia, M.1    Gingras, L.2    Beaulieu, L.3
  • 17
    • 33846826893 scopus 로고    scopus 로고
    • Reducing metal artifacts in cone-beam CT images by preprocessing projection data
    • Zhang YB, Zhang LF. Zhu R, et al. Reducing metal artifacts in cone-beam CT images by preprocessing projection data. Int J Radiat Oncol Biol Phys. 2007;67:924-932.
    • (2007) Int J Radiat Oncol Biol Phys. , vol.67 , pp. 924-932
    • Zhang, Y.B.1    Zhang, L.F.2    Zhu, R.3
  • 18
    • 14344266358 scopus 로고    scopus 로고
    • A hybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy
    • DOI 10.1016/j.brachy.2004.11.001
    • Xia D, Roeske JC. Yu L, et al. A hybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy. Brachvtherapy. 2005:4:18-23. (Pubitemid 40292825)
    • (2005) Brachytherapy , vol.4 , Issue.1 , pp. 18-23
    • Xia, D.1    Roeske, J.C.2    Yu, L.3    Pelizzari, C.A.4    Mundt, A.J.5    Pan, X.6
  • 19
    • 33846829584 scopus 로고    scopus 로고
    • Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate
    • Moseley DJ, White EA, Wiltshire KL, et al. Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate. Int J Radiat Oncol Biol Phys. 2007;67:942 953.
    • (2007) Int J Radiat Oncol Biol Phys. , vol.67 , Issue.942 , pp. 953
    • Moseley, D.J.1    White, E.A.2    Wiltshire, K.L.3
  • 20
    • 0019839830 scopus 로고
    • An algorithm for the reduction of metal clip artifacts in CT reconstructions
    • Glover GH, PeIc NJ. An algorithm for the reduction of metal clip artifacts in CT reconstructions. Med. Phys. 1981;8:799-807.
    • (1981) Med. Phys. , vol.8 , pp. 799-807
    • Glover, G.H.1    Peic, N.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.