메뉴 건너뛰기




Volumn 38, Issue 2, 2011, Pages 701-711

Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization

Author keywords

computed tomography; image reconstruction; metal artifact; optimization

Indexed keywords

CONSTRAINED OPTIMIZATION; GRADIENT METHODS; IMAGE RECONSTRUCTION; IMAGE SEGMENTATION; METALS; OPTIMIZATION; SET THEORY;

EID: 79551662218     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3533711     Document Type: Article
Times cited : (148)

References (30)
  • 1
    • 0345708391 scopus 로고    scopus 로고
    • A New Algorithm for Metal Artifact Reduction in Computed Tomography: In Vitro and in Vivo Evaluation after Total Hip Replacement
    • DOI 10.1097/01.rli.0000086495.96457.54
    • A. H. Mahnken, R. Raupach, J. E. Wildberger, B. Jung, N. Heussen, T. G. Flohr, R. W. Günther, and S. Schaller, " A new algorithm for metal artifact reduction in computed tomography.," Invest. Radiol. INVRAV 0020-9996 38, 769-775 (2003). 10.1097/01.rli.0000086495.96457.54 (Pubitemid 37444949)
    • (2003) Investigative Radiology , vol.38 , Issue.12 , pp. 769-775
    • Mahnken, A.H.1    Raupach, R.2    Wildberger, J.E.3    Jung, B.4    Heussen, N.5    Flohr, T.G.6    Gunther, R.W.7    Schaller, S.8
  • 3
    • 0034351113 scopus 로고    scopus 로고
    • X-ray CT metal artifact reduction using wavelets: An application for imaging total hip prostheses
    • DOI 10.1109/42.897816
    • S. Zhao, D. D. Robertson, and G. Wang, " X-ray CT metal artifact reduction using wavelets: An application for imaging total hip prostheses.," IEEE Trans. Med. Imaging ITMID4 0278-0062 19, 1238-1247 (2000). 10.1109/42.897816 (Pubitemid 32870329)
    • (2000) IEEE Transactions on Medical Imaging , vol.19 , Issue.12 , pp. 1238-1247
    • Zhao, S.1    Robertson, D.D.2    Wang, G.3    Whiting, B.4    Bae, K.T.5
  • 5
    • 0030983762 scopus 로고    scopus 로고
    • Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction
    • DOI 10.1097/00004728-199703000-00024
    • D. D. Robertson, " Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction.," J. Comput. Assist. Tomogr. JCATD5 0363-8715 21, 293-298 (1997). 10.1097/00004728-199703000-00024 (Pubitemid 27120036)
    • (1997) Journal of Computer Assisted Tomography , vol.21 , Issue.2 , pp. 293-298
    • Robertson, D.D.1    Yuan, J.2    Wang, G.3    Vannier, M.W.4
  • 7
    • 0036798793 scopus 로고    scopus 로고
    • Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction
    • DOI 10.1118/1.1509443
    • J. F. Williamson, B. R. Whiting, J. Benac, R. J. Murphy, G. J. Blaine, J. A. O'Sullivan, D. G. Politte, and D. L. Snyder, " Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction.," Med. Phys. MPHYA6 0094-2405 29, 2404-2418 (2002). 10.1118/1.1509443 (Pubitemid 35204449)
    • (2002) Medical Physics , vol.29 , Issue.10 , pp. 2404-2418
    • Williamson, J.F.1    Whiting, B.R.2    Benac, J.3    Murphy, R.J.4    Blaine, G.J.5    O'Sullivan, J.A.6    Politte, D.G.7    Snyder, D.L.8
  • 8
    • 0025676560 scopus 로고
    • Reduction of postoperative CT artefacts of pelvic fractures by use of titanium implants
    • ZZZZZZ 0147-7447.
    • N. A. Ebraheim, " Reduction of postoperative CT artefacts of pelvic fractures by use of titanium implants.," Orthopedics ZZZZZZ 0147-7447 13, 1357-1358 (1990).
    • (1990) Orthopedics , vol.13 , pp. 1357-1358
    • Ebraheim, N.A.1
  • 9
    • 0023637829 scopus 로고
    • CT-assisted assessment of bladder and rectum dose in gynecological implants
    • IOBPD3 0360-3016,. 10.1016/0360-3016(87)90327-0
    • C. C. Ling, " CT-assisted assessment of bladder and rectum dose in gynecological implants.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 13, 1577-1582 (1987). 10.1016/0360-3016(87)90327-0
    • (1987) Int. J. Radiat. Oncol., Biol., Phys. , vol.13 , pp. 1577-1582
    • Ling, C.C.1
  • 10
    • 0033431430 scopus 로고    scopus 로고
    • Iterative X-ray cone-beam tomography for metal artifact reduction and local region reconstruction
    • G. Wang, " Iterative x-ray cone-beam tomography for metal artifact reduction and local region reconstruction.," Microsc. Microanal. MIMIF7 1431-9276 5, 58-65 (1999). 10.1017/S1431927699000057 (Pubitemid 129479946)
    • (1999) Microscopy and Microanalysis , vol.5 , Issue.1 , pp. 58-65
    • Wang, G.1    Vannier, M.W.2    Cheng, P.-C.3
  • 11
    • 0030348393 scopus 로고    scopus 로고
    • A very fast implementation of 2D iterative reconstruction algorithms
    • P. Toft, " A very fast implementation of 2D iterative reconstruction algorithms.," IEEE Proc Med Imaging Conf 3, 1742-1746 (1996).
    • (1996) IEEE Proc Med Imaging Conf , vol.3 , pp. 1742-1746
    • Toft, P.1
  • 12
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • W. A. Kalender, R. Hebel, and J. A. Ebersberger, " Reduction of CT artifacts caused by metallic implants.," Radiology RADLAX 0033-8419 164, 576-577 (1987). (Pubitemid 17097989)
    • (1987) Radiology , vol.164 , Issue.2 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.3
  • 13
    • 17144438952 scopus 로고
    • Algorithms for reduction of CT artifacts caused by metallic implants
    • E. Klotz, W. A. Kalender, R. Sokiranski, and D. Felsenberg, " Algorithms for reduction of CT artifacts caused by metallic implants.," SPIE Med Imaging IV 1234, 642-650 (1990).
    • (1990) SPIE Med Imaging IV , vol.1234 , pp. 642-650
    • Klotz, E.1    Kalender, W.A.2    Sokiranski, R.3    Felsenberg, D.4
  • 14
    • 0017955879 scopus 로고
    • Image reconstruction from projections: 3. Projection completion methods (Theory)
    • R. M. Lewitt and R. H. T. Bates, " Image reconstruction from projections: III. Projection completion methods.," Optik (Stuttgart) OTIKAJ 0030-4026 50, 189-204 (1978). (Pubitemid 8610522)
    • (1978) Optik (Jena) , vol.50 , Issue.3 , pp. 189-204
    • Lewitt, R.M.1    Bates, R.H.T.2
  • 15
    • 34548219962 scopus 로고    scopus 로고
    • Comparing computed tomography localization with daily ultrasound during image-guided radiation therapy for the treatment of prostate cancer: A prospective evaluation
    • JACMFG 1526-9914,. 10.1120/jacmv8i3.2268
    • S. J. Feigenberg, K. Paskalev, S. McNeeley, E. M. Horwitz, A. Konski, L. Wang, C. Ma, and A. Pollack, " Comparing computed tomography localization with daily ultrasound during image-guided radiation therapy for the treatment of prostate cancer: A prospective evaluation.," J. Appl. Clin. Med. Phys. JACMFG 1526-9914 8, 2268-2268 (2007). 10.1120/jacmp.v8i3.2268
    • (2007) J. Appl. Clin. Med. Phys. , vol.8 , pp. 2268-2268
    • Feigenberg, S.J.1    Paskalev, K.2    McNeeley, S.3    Horwitz, E.M.4    Konski, A.5    Wang, L.6    Ma, C.7    Pollack, A.8
  • 16
    • 58149141914 scopus 로고    scopus 로고
    • Iterative image reconstruction for CBCT using edge-preserving prior
    • MPHYA6 0094-2405,. 10.1118/1.3036112
    • J. Wang, T. Li, and L. Xing, " Iterative image reconstruction for CBCT using edge-preserving prior.," Med. Phys. MPHYA6 0094-2405 36, 252-260 (2009). 10.1118/1.3036112
    • (2009) Med. Phys. , vol.36 , pp. 252-260
    • Wang, J.1    Li, T.2    Xing, L.3
  • 17
    • 79551677217 scopus 로고    scopus 로고
    • Accurate determination of the shape and location of metal objects in x-ray computed tomography
    • PSISDG 0277-786X.
    • J. Wang and L. Xing, " Accurate determination of the shape and location of metal objects in x-ray computed tomography.," Proc. SPIE PSISDG 0277-786X 7622, 76225A-76225A-10 (2010).
    • (2010) Proc. SPIE , vol.7622
    • Wang, J.1    Xing, L.2
  • 18
    • 78149448356 scopus 로고    scopus 로고
    • Sinogram processing and binary reconstruction for determination of the shape and location of metal objects in computed tomography (CT)
    • MPHYA6 0094-2405,. 10.1118/1.3505294
    • B. Meng, J. Wang, and L. Xing, " Sinogram processing and binary reconstruction for determination of the shape and location of metal objects in computed tomography (CT).," Med. Phys. MPHYA6 0094-2405 37, 5867-5875 (2010). 10.1118/1.3505294
    • (2010) Med. Phys. , vol.37 , pp. 5867-5875
    • Meng, B.1    Wang, J.2    Xing, L.3
  • 19
    • 51849124226 scopus 로고    scopus 로고
    • Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
    • PHMBA7 0031-9155,. 10.1088/0031-9155/53/17/021
    • E. Y. Sidky and X. Pan, " Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization.," Phys. Med. Biol. PHMBA7 0031-9155 53, 4777-4807 (2008). 10.1088/0031-9155/53/17/021
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4777-4807
    • Sidky, E.Y.1    Pan, X.2
  • 20
    • 0028446166 scopus 로고
    • Penalized weighted least-squares image-reconstruction for positron emission tomography
    • ITMID4 0278-0062,. 10.1109/42.293921
    • J. A. Fessler, " Penalized weighted least-squares image-reconstruction for positron emission tomography.," IEEE Trans. Med. Imaging ITMID4 0278-0062 13, 290-300 (1994). 10.1109/42.293921
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 290-300
    • Fessler, J.A.1
  • 21
    • 33947260155 scopus 로고    scopus 로고
    • Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography
    • DOI 10.1109/TMI.2006.882141
    • J. Wang, T. Li, H. B. Lu, and Z. R. Liang, " Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose x-ray computed tomography.," IEEE Trans. Med. Imaging ITMID4 0278-0062 25, 1272-1283 (2006). 10.1109/TMI.2006.882141 (Pubitemid 46417077)
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , Issue.10 , pp. 1272-1283
    • Wang, J.1    Li, T.2    Lu, H.3    Liang, Z.4
  • 22
    • 8344272167 scopus 로고    scopus 로고
    • Nonlinear sinogram smoothing for low-dose x-ray CT
    • IETNAE 0018-9499,. 10.1109/TNS.2004.834824
    • T. F. Li, X. Li, J. Wang, J. H. Wen, H. B. Lu, J. Hsieh, and Z. R. Liang, " Nonlinear sinogram smoothing for low-dose x-ray CT.," IEEE Trans. Nucl. Sci. IETNAE 0018-9499 51, 2505-2513 (2004). 10.1109/TNS.2004.834824
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , pp. 2505-2513
    • Li, T.F.1    Li, X.2    Wang, J.3    Wen, J.H.4    Lu, H.B.5    Hsieh, J.6    Liang, Z.R.7
  • 23
    • 45949102973 scopus 로고    scopus 로고
    • An experimental study on the noise properties of x-ray CT sinogram data in Radon space
    • DOI 10.1088/0031-9155/53/12/018, PII S0031915508719481
    • J. Wang, H. Lu, Z. Liang, D. Eremina, G. Zhang, S. Wang, J. Chen, and J. Manzione, " An experimental study on the noise properties of x-ray CT sinogram data in Radon space.," Phys. Med. Biol. PHMBA7 0031-9155 53, 3327-3341 (2008). 10.1088/0031-9155/53/12/018 (Pubitemid 351892405)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.12 , pp. 3327-3341
    • Wang, J.1    Lu, H.2    Liang, Z.3    Eremina, D.4    Zhang, G.5    Wang, S.6    Chen, J.7    Manzione, J.8
  • 24
    • 0027542459 scopus 로고
    • Local update strategy for iterative reconstruction from projections
    • DOI 10.1109/78.193196
    • K. Sauer and C. Bouman, " A local update strategy for iterative reconstruction from projections.," IEEE Trans. Signal Process. ITPRED 1053-587X 41, 534-548 (1993). 10.1109/78.193196 (Pubitemid 23609319)
    • (1993) IEEE Transactions on Signal Processing , vol.41 , Issue.2 , pp. 534-549
    • Sauer Ken1    Bouman Charles2
  • 25
    • 0034310513 scopus 로고    scopus 로고
    • Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography
    • DOI 10.1109/42.896783
    • P. Sukovic and N. H. Clinthorne, " Penalized weighted least-squares image reconstruction for dual energy x-ray transmission tomography.," IEEE Trans. Med. Imaging ITMID4 0278-0062 19, 1075-1081 (2000). 10.1109/42.896783 (Pubitemid 32189051)
    • (2000) IEEE Transactions on Medical Imaging , vol.19 , Issue.11 , pp. 1075-1081
    • Sukovic, P.1    Clinthorne, N.H.2
  • 26
    • 33746927954 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram restoration for computed tomography
    • DOI 10.1109/TMI.2006.875429, 1661697
    • P. J. La Riviere, J. G. Brian, and P. A. Vargas, " Penalized-likelihood sinogram restoration for computed tomography.," IEEE Trans. Med. Imaging ITMID4 0278-0062 25, 1022-1036 (2006). 10.1109/TMI.2006. 875429 (Pubitemid 44192174)
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , Issue.8 , pp. 1022-1036
    • La Riviere, P.J.1    Bian, J.2    Vargas, P.A.3
  • 28
    • 31744440684 scopus 로고    scopus 로고
    • Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information
    • DOI 10.1109/TIT.2005.862083
    • E. Candes, J. Romberg, and T. Tao, " Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information.," IEEE Trans. Inf. Theory IETTAW 0018-9448 52, 489-509 (2006). 10.1109/TIT.2005.862083 (Pubitemid 43174093)
    • (2006) IEEE Transactions on Information Theory , vol.52 , Issue.2 , pp. 489-509
    • Candes, E.J.1    Romberg, J.2    Tao, T.3
  • 29
    • 33745604236 scopus 로고    scopus 로고
    • Stable signal recovery from incomplete and inaccurate measurements
    • DOI 10.1002/cpa.20124
    • E. Cand̀s, J. Romberg, and T. Tao, " Stable signal recovery from incomplete and inaccurate measurements.," Commun. Pure Appl. Math. CPMAMV 0010-3640 59, 1207-1223 (2006). 10.1002/cpa.20124 (Pubitemid 43988295)
    • (2006) Communications on Pure and Applied Mathematics , vol.59 , Issue.8 , pp. 1207-1223
    • Candes, E.J.1    Romberg, J.K.2    Tao, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.