메뉴 건너뛰기




Volumn 32, Issue 4, 2008, Pages 621-629

Computed tomographic metal artifact reduction for the detection and quantitation of small features near large metallic implants: A comparison of published methods

Author keywords

Aneurysm; Aorta; Aortic; Computed tomography; CT; Grafts; Interventional procedures; Late phase imaging

Indexed keywords

ADAPTIVE FILTERING; ADAPTIVE FILTERS; COMPUTERIZED TOMOGRAPHY; HIP PROSTHESES; IMAGE ENHANCEMENT; IMAGE SEGMENTATION; INTERPOLATION; TRACE ELEMENTS;

EID: 49949095531     PISSN: 03638715     EISSN: None     Source Type: Journal    
DOI: 10.1097/RCT.0b013e318149e215     Document Type: Article
Times cited : (47)

References (19)
  • 1
    • 0031794571 scopus 로고    scopus 로고
    • Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise
    • Hsieh J. Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise. Med Phys. 1998;25: 2139-2147.
    • (1998) Med Phys , vol.25 , pp. 2139-2147
    • Hsieh, J.1
  • 2
    • 0019978056 scopus 로고
    • The effects of scatter in x-ray computed tomography
    • Joseph PM, Spital RD. The effects of scatter in x-ray computed tomography. Med Phys. 1982;9:464-472.
    • (1982) Med Phys , vol.9 , pp. 464-472
    • Joseph, P.M.1    Spital, R.D.2
  • 3
    • 0018349307 scopus 로고
    • Computed tomography reconstruction from hollow projections: An application to in vivo evaluation of artificial hip joints
    • Hinderling T, Ruegsegger P, Anliker M, et al. Computed tomography reconstruction from hollow projections: an application to in vivo evaluation of artificial hip joints. J Comput Assist Tomogr. 1979;3: 52-57.
    • (1979) J Comput Assist Tomogr , vol.3 , pp. 52-57
    • Hinderling, T.1    Ruegsegger, P.2    Anliker, M.3
  • 4
    • 0019839830 scopus 로고
    • An algorithm for the reduction of metal clip artifacts in CT reconstructions
    • Glover GH, Pelc NJ. An algorithm for the reduction of metal clip artifacts in CT reconstructions. Med Phys. 1981;8:799-807.
    • (1981) Med Phys , vol.8 , pp. 799-807
    • Glover, G.H.1    Pelc, N.J.2
  • 6
    • 0033815263 scopus 로고    scopus 로고
    • CT of metal implants: Reduction of artifacts using an extended CT scale technique
    • Link TM, Berning W, Scherf S, et al. CT of metal implants: reduction of artifacts using an extended CT scale technique. J Comput Assist Tomogr. 2000;24:165-172.
    • (2000) J Comput Assist Tomogr , vol.24 , pp. 165-172
    • Link, T.M.1    Berning, W.2    Scherf, S.3
  • 7
    • 33645672304 scopus 로고    scopus 로고
    • An alternate line erasure and readout (ALER) method for implementing slot-scan imaging technique with a flat-panel detector - initial experiences
    • Liu XM, Shaw CC, Altunbas MC, et al. An alternate line erasure and readout (ALER) method for implementing slot-scan imaging technique with a flat-panel detector - initial experiences. IEEE Trans Med Imaging. 2006;25:496-502.
    • (2006) IEEE Trans Med Imaging , vol.25 , pp. 496-502
    • Liu, X.M.1    Shaw, C.C.2    Altunbas, M.C.3
  • 8
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • Kalender WA, Hebel R, Ebersberger J. Reduction of CT artifacts caused by metallic implants. Radiology. 1987;164:576-577.
    • (1987) Radiology , vol.164 , pp. 576-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.3
  • 9
    • 0035052748 scopus 로고    scopus 로고
    • Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT
    • Kachelriess M, Watzke O, Kalender WA. Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT. Med Phys. 2001;28:475-490.
    • (2001) Med Phys , vol.28 , pp. 475-490
    • Kachelriess, M.1    Watzke, O.2    Kalender, W.A.3
  • 10
    • 5644240930 scopus 로고    scopus 로고
    • Segmentation aided adaptive filtering for metal artifact reduction in radio-therapeutic CT images
    • Olive CS, Klaus MR, Pekar V, et al. Segmentation aided adaptive filtering for metal artifact reduction in radio-therapeutic CT images. Proc Soc Photo Opt Instrum Eng. 2004;5370:1991-2002.
    • (2004) Proc Soc Photo Opt Instrum Eng , vol.5370 , pp. 1991-2002
    • Olive, C.S.1    Klaus, M.R.2    Pekar, V.3
  • 11
    • 2542496945 scopus 로고    scopus 로고
    • A pragmatic approach to metal artifact reduction in CT: Merging of metal artifact reduced images
    • Watzke O, Kalender WA. A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images. Eur Radiol. 2004;14:849-856.
    • (2004) Eur Radiol , vol.14 , pp. 849-856
    • Watzke, O.1    Kalender, W.A.2
  • 12
    • 0034351113 scopus 로고    scopus 로고
    • X-ray CT metal artifact reduction using wavelets: An application for imaging total hip prostheses
    • Zhao S, Robertson DD, Wang G, et al. X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses. IEEE Trans Med Imaging. 2000;19:1238-1247.
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 1238-1247
    • Zhao, S.1    Robertson, D.D.2    Wang, G.3
  • 13
    • 0345708391 scopus 로고    scopus 로고
    • A new algorithm for metal artifact reduction in computed tomography: In vitro and in vivo evaluation after total hip replacement
    • Mahnken AH, Raupach R, Wildberger JE, et al. A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement. Invest Radiol. 2003;38: 769-775.
    • (2003) Invest Radiol , vol.38 , pp. 769-775
    • Mahnken, A.H.1    Raupach, R.2    Wildberger, J.E.3
  • 14
    • 0036210548 scopus 로고    scopus 로고
    • Technical considerations: CT and MR imaging in the postoperative orthopedic patient
    • White LM, Buckwalter KA. Technical considerations: CT and MR imaging in the postoperative orthopedic patient. Semin Musculoskelet Radiol. 2002;6:5-17.
    • (2002) Semin Musculoskelet Radiol , vol.6 , pp. 5-17
    • White, L.M.1    Buckwalter, K.A.2
  • 15
    • 21244471813 scopus 로고    scopus 로고
    • An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: Experimental and clinical studies
    • Yazdia M, Gingras L, Beaulieu L. An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies. Int J Radiat Oncol Biol Phys. 2005;62:1224-1231.
    • (2005) Int J Radiat Oncol Biol Phys , vol.62 , pp. 1224-1231
    • Yazdia, M.1    Gingras, L.2    Beaulieu, L.3
  • 16
    • 0036798793 scopus 로고    scopus 로고
    • Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction
    • Williamson JF, Whiting BR, Benac J, et al. Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction. Med Phys. 2002; 29:2404-2418.
    • (2002) Med Phys , vol.29 , pp. 2404-2418
    • Williamson, J.F.1    Whiting, B.R.2    Benac, J.3
  • 17
    • 0035491479 scopus 로고    scopus 로고
    • An iterative maximum-likelihood polychromatic algorithm for CT
    • De Man B, Nuyts J, Dupont P, et al. An iterative maximum-likelihood polychromatic algorithm for CT. IEEE Trans Med Imaging. 2001; 20:999-1008.
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 999-1008
    • De Man, B.1    Nuyts, J.2    Dupont, P.3
  • 18
    • 0030983762 scopus 로고    scopus 로고
    • Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction
    • Robertson DD, Yuan J, Wang G, et al. Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction. J Comput Assist Tomogr. 1997;21:293-298.
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 293-298
    • Robertson, D.D.1    Yuan, J.2    Wang, G.3
  • 19
    • 0035491083 scopus 로고    scopus 로고
    • Deblurring subject to nonnegativity constraints when known functions are present with application to object-constrained computerized tomography
    • Snyder DL, O'Sullivan JA, Whiting BR, et al. Deblurring subject to nonnegativity constraints when known functions are present with application to object-constrained computerized tomography. IEEE Trans Med Imaging. 2001;20:1009-1017.
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 1009-1017
    • Snyder, D.L.1    O'Sullivan, J.A.2    Whiting, B.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.