메뉴 건너뛰기




Volumn 60, Issue 2, 2012, Pages 165-195

Proactive thermal management in green datacenters

Author keywords

Air cooling system; Data center; Modeling; Proactive approach; Thermal management

Indexed keywords

AIR CONDITIONERS; AIR COOLING SYSTEM; CONTROL APPROACH; COOLING ENERGY; COOLING EQUIPMENT; DATA CENTERS; DELAYED RESPONSE; DUTY CYCLES; EQUIPMENT DAMAGE; EQUIPMENT FAILURES; FAN SPEED; MANAGEMENT TECHNIQUES; OPTIMIZATION FRAMEWORK; PERFORMANCE DEGRADATION; PRO-ACTIVE APPROACH; SOCIETAL IMPACTS; STORAGE CAPACITY;

EID: 84861950279     PISSN: 09208542     EISSN: 15730484     Source Type: Journal    
DOI: 10.1007/s11227-010-0453-8     Document Type: Article
Times cited : (48)

References (29)
  • 2
    • 4344572635 scopus 로고    scopus 로고
    • ASHRAE Technical Committees. American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE
    • ASHRAE Technical Committees (2004) Thermal guidelines for data processing environments. American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)
    • (2004) Thermal Guidelines for Data Processing Environments
  • 3
    • 34247560899 scopus 로고    scopus 로고
    • Computational fluid dynamics modeling of high compute density data centers to assure system inlet air specifications
    • Beitelmal AH, Patel CD (2007) Computational fluid dynamics modeling of high compute density data centers to assure system inlet air specifications. Distrib Parallel Databases 21(2-3):227-238
    • (2007) Distrib Parallel Databases , vol.21 , Issue.2-3 , pp. 227-238
    • Beitelmal, A.H.1    Patel, C.D.2
  • 4
    • 28244487155 scopus 로고    scopus 로고
    • High-performance, power-aware distributed computing for scientific applications
    • DOI 10.1109/MC.2005.380
    • Cameron KW, Ge R, Feng X (2005) High-performance, power-aware distributed computing for scientific applications. Computer 38(11):40-47 (Pubitemid 41709766)
    • (2005) Computer , vol.38 , Issue.11 , pp. 40-47
    • Cameron, K.W.1    Ge, R.2    Feng, X.3
  • 6
    • 67650083370 scopus 로고    scopus 로고
    • EPA report to congress on server and data center energy efficiency
    • EPA
    • EPA (2007) EPA report to congress on server and data center energy efficiency. Technical report, US Environmental Protection Agency
    • (2007) Technical Report, US Environmental Protection Agency
  • 13
    • 60449095133 scopus 로고    scopus 로고
    • A cooperative game theoretical technique for joint optimization of energy consumption and response time in computational grids
    • Khan SU, Ahmad I (2009) A cooperative game theoretical technique for joint optimization of energy consumption and response time in computational grids. IEEE Trans Parallel Distrib Syst 20(3):346-360
    • (2009) IEEE Trans Parallel Distrib Syst , vol.20 , Issue.3 , pp. 346-360
    • Khan, S.U.1    Ahmad, I.2
  • 14
    • 84861956348 scopus 로고    scopus 로고
    • A survey of the research on power management techniques for high-performance systems
    • Liu Y, Zhu H (2009) A survey of the research on power management techniques for high-performance systems. Softw Pract Exp
    • (2009) Softw Pract Exp
    • Liu, Y.1    Zhu, H.2
  • 16
    • 70449525430 scopus 로고    scopus 로고
    • Spatio-temporal thermalaware job scheduling to minimize energy consumption in virtualized heterogeneous data centers
    • Mukherjee T, Banerjee A, Varsamopoulos G, Gupta SKS, Rungta S (2009) Spatio-temporal thermalaware job scheduling to minimize energy consumption in virtualized heterogeneous data centers. Comput Netw 53(17):2888-2904
    • (2009) Comput Netw , vol.53 , Issue.17 , pp. 2888-2904
    • Mukherjee, T.1    Banerjee, A.2    Varsamopoulos, G.3    Gupta, S.K.S.4    Rungta, S.5
  • 20
    • 34247565733 scopus 로고    scopus 로고
    • Modeling of data center airflow and heat transfer: State of the art and future trends
    • DOI 10.1007/s10619-006-7007-3, High Density Data Centers
    • Rambo J, Joshi Y (2007) Modeling of data center airflow and heat transfer: State of the art and future trends. Distrib Parallel Databases 21(2-3):193-225 (Pubitemid 46673097)
    • (2007) Distributed and Parallel Databases , vol.21 , Issue.2-3 , pp. 193-225
    • Rambo, J.1    Joshi, Y.2
  • 21
    • 20344374995 scopus 로고    scopus 로고
    • Thermal profile of a high-density data center - Methodology to thermally characterize a data center
    • NA-04-4-2, Technical and Symposium Papers - 2004 Annual Meeting of the American Society of Heating, Refrigerating and Air-Conditioning Engineers
    • Schmidt RR (2004) Thermal profile of a high-density data center-methodology to thermally characterize a data center. Trans Am Soc Heat Refrig Air-Cond Eng (ASHRAE) 110(2):635-642 (Pubitemid 40785160)
    • (2004) ASHRAE Transactions , vol.110 , Issue.PART II , pp. 635-642
    • Schmidt, R.R.1    Kurkjia, C.2    Phillips, E.W.3    Scofield, C.M.4
  • 29
    • 72749127771 scopus 로고    scopus 로고
    • Cooperative power-aware scheduling in grid computing environments
    • Subrata R, Zomaya AY, Landfeldt B (2010) Cooperative power-aware scheduling in grid computing environments. J Parallel Distrib Comput 70(2):84-91
    • (2010) J Parallel Distrib Comput , vol.70 , Issue.2 , pp. 84-91
    • Subrata, R.1    Zomaya, A.Y.2    Landfeldt, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.