메뉴 건너뛰기




Volumn 2, Issue , 2001, Pages 905-914

Measurements and predictions of the flow distribution through perforated tiles in raised-floor data centers

Author keywords

[No Author keywords available]

Indexed keywords

AIR CONDITIONING; COOLING; DATA PROCESSING; FLOW MEASUREMENT; FLOW OF FLUIDS; HEAT LOSSES; MATHEMATICAL MODELS; PERFORATING; PRESSURE DROP;

EID: 0346938385     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (71)

References (10)
  • 1
    • 0012072925 scopus 로고    scopus 로고
    • Cooling of Large Computer Rooms - Design and Construction of ASCI 10 TeraOps
    • Maui, Hawaii
    • Quivey, B. and Bailey, A. M., 1999, "Cooling of Large Computer Rooms - Design and Construction of ASCI 10 TeraOps," Interpack 1999, Maui, Hawaii.
    • (1999) Interpack 1999
    • Quivey, B.1    Bailey, A.M.2
  • 2
    • 6244283583 scopus 로고    scopus 로고
    • The Sistine Chapel: HVAC Design for Special-Use Buildings
    • Bullock, C. E. and Phillip, F., 1996, "The Sistine Chapel: HVAC Design for Special-Use Buildings," ASHRAE Journal, Vol. 38, No. 4, pp. 49-58.
    • (1996) ASHRAE Journal , vol.38 , Issue.4 , pp. 49-58
    • Bullock, C.E.1    Phillip, F.2
  • 4
    • 0003105924 scopus 로고
    • Predicting Air Flow and Thermal Comfort in Offices
    • Ambi, H. B. and Gan, G., 1994, "Predicting Air Flow and Thermal Comfort in Offices," ASHRAE Journal, pp. 17-21.
    • (1994) ASHRAE Journal , pp. 17-21
    • Ambi, H.B.1    Gan, G.2
  • 6
    • 0347077714 scopus 로고    scopus 로고
    • Thermal Management of Office Data Processing Centers
    • Hawaii
    • Schmidt, R. R., 1997, "Thermal Management of Office Data Processing Centers," Interpack'97, Hawaii.
    • (1997) Interpack'97
    • Schmidt, R.R.1
  • 7
    • 0032269687 scopus 로고    scopus 로고
    • An Innovative Approach to the Environmental System Design for TLC Rooms in Telecom Italia
    • Cinato,P., Bianco, C., Licciardi, L., Pizzuti, F., Antonetti, M., and Grossoni, M., 1998, "An Innovative Approach to the Environmental System Design for TLC Rooms in Telecom Italia," Presented at Intelec 98.
    • (1998) Intelec 98
    • Cinato, P.1    Bianco, C.2    Licciardi, L.3    Pizzuti, F.4    Antonetti, M.5    Grossoni, M.6
  • 8
    • 0033709714 scopus 로고    scopus 로고
    • A Methodology for the Design of Perforated Tiles in Raised Floor Data Centers Using Computational Flow Analysis
    • Las Vegas, N. V., Proceedings
    • Kang, S., Schmidt, R., Kelkar, K., Radmehr, A., and Patankar, S., 2000, "A Methodology for the Design of Perforated Tiles in Raised Floor Data Centers Using Computational Flow Analysis," ITHERM 2000, Las Vegas, N. V., Proceedings, Vol. 1, pp. 215-224.
    • (2000) ITHERM 2000 , vol.1 , pp. 215-224
    • Kang, S.1    Schmidt, R.2    Kelkar, K.3    Radmehr, A.4    Patankar, S.5
  • 9
    • 0347708102 scopus 로고    scopus 로고
    • Innovative Research, Inc., Plymouth, MN, USA
    • Innovative Research, Inc., 2000, Reference Manual for COMPACT, Innovative Research, Inc., Plymouth, MN, USA.
    • (2000) Reference Manual for COMPACT


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.