-
1
-
-
0030898587
-
Pedicle screw fixation in spinal disorders: A European view
-
DOI 10.1007/BF01676569
-
Boos N, Webb JK. Pedicle screw fixation in spinal disorders: a European view. Eur Spine J 1997; 6: 2-18. (Pubitemid 27143836)
-
(1997)
European Spine Journal
, vol.6
, Issue.1
, pp. 2-18
-
-
Boos, N.1
Webb, J.K.2
-
2
-
-
0033794424
-
The use of pedicle-screw internal fixation for the operative treatment of spinal disorders
-
Gaines RW Jr. The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 2000; 82-A: 1458-76.
-
(2000)
J Bone Joint Surg Am
, vol.82 A
, pp. 1458-1476
-
-
Gaines Jr., R.W.1
-
3
-
-
77950548268
-
Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine
-
Rajan VV, Kamath V, Shetty AP, et al. Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine. Indian J Orthop 2010; 44: 163-8.
-
(2010)
Indian J Orthop
, vol.44
, pp. 163-168
-
-
Rajan, V.V.1
Kamath, V.2
Shetty, A.P.3
-
4
-
-
0035672336
-
Treatment of idiopathic scoliosis with CD-instrumentation - Lumbar pedicle screws versus laminar hooks in 66 patients
-
DOI 10.1080/000164701317269049
-
Wimmer C, Gluch H, Nogler M, et al. Treatment of idiopathic sco-liosis with CD-instrumentation: lumbar pedicle screws versus laminar hooks in 66 patients. Acta Orthop Scand 2001; 72: 615-20. (Pubitemid 34031659)
-
(2001)
Acta Orthopaedica Scandinavica
, vol.72
, Issue.6
, pp. 615-620
-
-
Wimmer, C.1
Gluch, H.2
Nogler, M.3
Walochnik, N.4
-
5
-
-
0028567083
-
Comparison of Cotrel-Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis
-
Suk SI, Lee CK, Min HJ, et al. Comparison of Cotrel-Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis. Int Orthop 1994; 18: 341-6.
-
(1994)
Int Orthop
, vol.18
, pp. 341-346
-
-
Suk, S.I.1
Lee, C.K.2
Min, H.J.3
-
6
-
-
0033834682
-
Segmental pedicle screw instrumentation in idiopathic thoracolumbar and lumbar scoliosis
-
Halm H, Niemeyer T, Link T, et al. Segmental pedicle screw instrumentation in idiopathic thoracolumbar and lumbar scoliosis. Eur Spine J 2000; 9: 191-7.
-
(2000)
Eur Spine J
, vol.9
, pp. 191-197
-
-
Halm, H.1
Niemeyer, T.2
Link, T.3
-
7
-
-
14844302180
-
Accuracy and efficacy of thoracic pedicle screws in curves more than 90°
-
DOI 10.1097/01.brs.0000150482.26918.d8
-
Kuklo TR, Lenke LG, O'Brien MF, et al. Accuracy and efficacy of thoracic pedicle screws in curves more than 90 degrees. Spine (Phila Pa 1976) 2005; 30: 222-6. (Pubitemid 40348214)
-
(2005)
Spine
, vol.30
, Issue.2
, pp. 222-226
-
-
Kuklo, T.R.1
Lenke, L.G.2
O'Brien, M.F.3
Lehman Jr., R.A.4
Polly Jr., D.W.5
Schroeder, T.M.6
-
8
-
-
0742269913
-
Direct vertebral rotation: A new technique of three-dimensional deformity correction with segmental pedicle screw fixation in adolescent idiopathic scoliosis
-
Lee SM, Suk SI, Chung ER. Direct vertebral rotation: a new technique of three-dimensional deformity correction with segmental pedicle screw fixation in adolescent idiopathic scoliosis. Spine (Phila Pa 1976) 2004; 29: 343-9.
-
(2004)
Spine (Phila Pa 1976)
, vol.29
, pp. 343-349
-
-
Lee, S.M.1
Suk, S.I.2
Chung, E.R.3
-
9
-
-
77952369629
-
Complications of pedicle screw fixation in scoliosis surgery: A systematic review
-
Hicks JM, Singla A, Shen FH, et al. Complications of pedicle screw fixation in scoliosis surgery: a systematic review. Spine (Phila Pa 1976) 2010; 35: E465-70.
-
(2010)
Spine (Phila Pa 1976)
, vol.35
-
-
Hicks, J.M.1
Singla, A.2
Shen, F.H.3
-
10
-
-
34447305748
-
Complications of thoracic pedicle screws in scoliosis treatment
-
DOI 10.1097/BRS.0b013e318074d604, PII 0000763220070701000014
-
Di Silvestre M, Parisini P, Lolli F, et al. Complications of thoracic pedicle screws in scoliosis treatment. Spine (Phila Pa 1976) 2007; 32: 1655-61. (Pubitemid 47051850)
-
(2007)
Spine
, vol.32
, Issue.15
, pp. 1655-1661
-
-
Di Silvestre, M.1
Parisini, P.2
Lolli, F.3
Bakaloudis, G.4
-
11
-
-
77956895990
-
Complications associated with thoracic pedicle screws in spinal deformity
-
Li G, Lv G, Passias P, et al. Complications associated with thoracic pedicle screws in spinal deformity. Eur Spine J 2010; 19: 1576-84.
-
(2010)
Eur Spine J
, vol.19
, pp. 1576-1584
-
-
Li, G.1
Lv, G.2
Passias, P.3
-
13
-
-
77953578558
-
Intraoperative computed tomography image-guided navigation for posterior tho-racolumbar spinal instrumentation in spinal deformity surgery
-
Tormenti MJ, Kostov DB, Gardner PA, et al. Intraoperative computed tomography image-guided navigation for posterior tho-racolumbar spinal instrumentation in spinal deformity surgery. Neurosurg Focus 2010; 28: E11.
-
(2010)
Neurosurg Focus
, vol.28
-
-
Tormenti, M.J.1
Kostov, D.B.2
Gardner, P.A.3
-
14
-
-
34250782220
-
Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: Comparison between conventional fluoroscopic and computer-assisted technique
-
DOI 10.1097/BRS.0b013e318068661e, PII 0000763220070615000014
-
Kotani Y, Abumi K, Ito M, et al. Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique. Spine (Phila Pa 1976) 2007; 32: 1543-50. (Pubitemid 46956151)
-
(2007)
Spine
, vol.32
, Issue.14
, pp. 1543-1550
-
-
Kotani, Y.1
Abumi, K.2
Ito, M.3
Takahata, M.4
Sudo, H.5
Ohshima, S.6
Minami, A.7
-
15
-
-
77956188220
-
Less invasive surgical correction of adult degenerative scoliosis, part I: Technique and radiographic results
-
Scheufler KM, Cyron D, Dohmen H, et al. Less invasive surgical correction of adult degenerative scoliosis, part I: technique and radiographic results. Neurosurgery 2010; 67: 696-710.
-
(2010)
Neurosurgery
, vol.67
, pp. 696-710
-
-
Scheufler, K.M.1
Cyron, D.2
Dohmen, H.3
-
16
-
-
78650516733
-
Less invasive surgical correction of adult degenerative scoliosis. Part II: Complications and clinical outcome
-
discussion 21
-
Scheufler KM, Cyron D, Dohmen H, et al. Less invasive surgical correction of adult degenerative scoliosis. Part II: complications and clinical outcome. Neurosurgery 2010; 67: 1609-21; discussion 21.
-
(2010)
Neurosurgery
, vol.67
, pp. 1609-1621
-
-
Scheufler, K.M.1
Cyron, D.2
Dohmen, H.3
-
17
-
-
33846239956
-
Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries
-
DOI 10.1097/01.brs.0000252094.64857.ab, PII 0000763220070115000030
-
Rajasekaran S, Vidyadhara S, Ramesh P, et al. Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine (Phila Pa 1976) 2007; 32: E56-64. (Pubitemid 46105794)
-
(2007)
Spine
, vol.32
, Issue.2
-
-
Rajasekaran, S.1
Vidyadhara, S.2
Ramesh, P.3
Shetty, A.P.4
-
18
-
-
0033994068
-
Incorporation of intraoperative computerized tomography in a newly developed spinal navigation technique
-
DOI 10.1002/(SICI)1097-0150(2000)5:1<18::AID-IGS3>3.0.CO;2-T
-
Haberland N, Ebmeier K, Grunewald JP, et al. Incorporation of intraoperative computerized tomography in a newly developed spinal navigation technique. Comput Aided Surg 2000; 5: 18-27. (Pubitemid 30225114)
-
(2000)
Computer Aided Surgery
, vol.5
, Issue.1
, pp. 18-27
-
-
Haberland, N.1
Ebmeier, K.2
Grunewald, J.P.3
Hliscs, R.4
Kalff, R.-L.5
-
19
-
-
67651149876
-
Intraoperative computed tomography with integrated navigation system in a multidisci-plinary operating suite
-
discussion 239-40
-
Uhl E, Zausinger S, Morhard D, et al. Intraoperative computed tomography with integrated navigation system in a multidisci-plinary operating suite. Neurosurgery 2009; 64 (suppl 2): 231-9; discussion 239-40.
-
(2009)
Neurosurgery
, vol.64
, Issue.SUPPL. 2
, pp. 231-239
-
-
Uhl, E.1
Zausinger, S.2
Morhard, D.3
-
20
-
-
74249095923
-
Intraoperative computed tomography with integrated navigation system in spinal stabilizations
-
Zausinger S, Scheder B, Uhl E, et al. Intraoperative computed tomography with integrated navigation system in spinal stabilizations. Spine (Phila Pa 1976) 2009; 34: 2919-26.
-
(2009)
Spine (Phila Pa 1976)
, vol.34
, pp. 2919-2926
-
-
Zausinger, S.1
Scheder, B.2
Uhl, E.3
-
21
-
-
0025267440
-
Accuracy of pedicular screw placement in vivo
-
Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 1990; 15: 11-4. (Pubitemid 20102491)
-
(1990)
Spine
, vol.15
, Issue.1
, pp. 11-14
-
-
Gertzbein, S.D.1
Robbins, S.E.2
-
22
-
-
0345357712
-
Inter-and intraobserver reliability of computed tomography in assessment of thoracic pedicle screw placement
-
DOI 10.1097/01.BRS.0000092341.56793.F1
-
Rao G, Brodke DS, Rondina M, et al. Inter-and intraobserver reliability of computed tomography in assessment of thoracic pedicle screw placement. Spine (Phila Pa 1976) 2003; 28: 2527-30. (Pubitemid 37448969)
-
(2003)
Spine
, vol.28
, Issue.22
, pp. 2527-2530
-
-
Rao, G.1
Brodke, D.S.2
Rondina, M.3
Bacchus, K.4
Dailey, A.T.5
-
23
-
-
70349671492
-
Posterior-only multilevel modi-fied vertebral column resection for extremely severe Pott's kyphotic deformity
-
Wang Y, Zhang Y, Zhang X, et al. Posterior-only multilevel modi-fied vertebral column resection for extremely severe Pott's kyphotic deformity. Eur Spine J 2009; 18: 1436-41.
-
(2009)
Eur Spine J
, vol.18
, pp. 1436-1441
-
-
Wang, Y.1
Zhang, Y.2
Zhang, X.3
-
24
-
-
41049095792
-
A single posterior approach for multilevel modified vertebral column resection in adults with severe rigid congenital kyphoscoliosis: A retrospective study of 13 cases
-
Wang Y, Zhang Y, Zhang X, et al. A single posterior approach for multilevel modified vertebral column resection in adults with severe rigid congenital kyphoscoliosis: a retrospective study of 13 cases. Eur Spine J 2008; 17: 361-72.
-
(2008)
Eur Spine J
, vol.17
, pp. 361-372
-
-
Wang, Y.1
Zhang, Y.2
Zhang, X.3
-
25
-
-
70349592082
-
Complication of thoracic pedicle screw fixation in spinal deformities
-
Deng Y, Zhou Y, Lu G, et al. [Complication of thoracic pedicle screw fixation in spinal deformities]. Zhong Nan Da Xue Xue Bao Yi Xue Ban 2009; 34: 820-4.
-
(2009)
Zhong Nan da Xue Xue Bao Yi Xue Ban
, vol.34
, pp. 820-824
-
-
Deng, Y.1
Zhou, Y.2
Lu, G.3
-
27
-
-
0035884966
-
Thoracic pedicle screw fixation in spinal deformities: Are they really safe?
-
Suk SI, Kim WJ, Lee SM, et al. Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine (Phila Pa 1976) 2001; 26: 2049-57.
-
(2001)
Spine (Phila Pa 1976)
, vol.26
, pp. 2049-2057
-
-
Suk, S.I.1
Kim, W.J.2
Lee, S.M.3
-
28
-
-
0032532750
-
Fatal cardiac tamponade associated with posterior spinal instrumentation: A case report
-
DOI 10.1097/00007632-199810150-00017
-
Heini P, Scholl E, Wyler D, et al. Fatal cardiac tamponade associated with posterior spinal instrumentation: a case report. Spine (Phila Pa 1976) 1998; 23: 2226-30. (Pubitemid 28485182)
-
(1998)
Spine
, vol.23
, Issue.20
, pp. 2226-2230
-
-
Heini, P.1
Scholl, E.2
Wyler, D.3
Eggli, S.4
-
29
-
-
0031413907
-
Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis
-
DOI 10.1097/00007632-199710010-00008
-
Liljenqvist UR, Halm HF, Link TM. Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine (Phila Pa 1976) 1997; 22: 2239-45. (Pubitemid 28074054)
-
(1997)
Spine
, vol.22
, Issue.19
, pp. 2239-2245
-
-
Liljenqvist, U.R.1
Halm, H.F.H.2
Link, T.M.3
-
30
-
-
0035500223
-
In vivo accuracy of thoracic pedicle screws
-
DOI 10.1097/00007632-200111010-00010
-
Belmont PJ Jr, Klemme WR, Dhawan A, et al. In vivo accuracy of thoracic pedicle screws. Spine (Phila Pa 1976) 2001; 26: 2340-6. (Pubitemid 33043316)
-
(2001)
Spine
, vol.26
, Issue.21
, pp. 2340-2346
-
-
Belmont Jr., P.J.1
Klemme, W.R.2
Dhawan, A.3
Polly Jr., D.W.4
-
31
-
-
0037099509
-
Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities
-
DOI 10.1097/00007632-200207150-00015
-
Belmont PJ Jr, Klemme WR, Robinson M, et al. Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities. Spine (Phila Pa 1976) 2002; 27: 1558-66. (Pubitemid 34787183)
-
(2002)
Spine
, vol.27
, Issue.14
, pp. 1558-1566
-
-
Belmont Jr., P.J.1
Klemme, W.R.2
Robinson, M.3
Polly Jr., D.W.4
-
32
-
-
57049113762
-
Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique
-
Modi HN, Suh SW, Fernandez H, et al. Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique. Eur Spine J 2008; 17: 1686-96.
-
(2008)
Eur Spine J
, vol.17
, pp. 1686-1696
-
-
Modi, H.N.1
Suh, S.W.2
Fernandez, H.3
-
33
-
-
0042568676
-
Intraoperative spinal navigation
-
Holly L T, Foley KT. Intraoperative spinal navigation. Spine (Phila Pa 1976) 2003; 28 (suppl): S54-61. (Pubitemid 36959584)
-
(2003)
Spine
, vol.28
, Issue.15 SUPPL.
-
-
Holly, L.T.1
Foley, K.T.2
-
34
-
-
80052564997
-
Pedicle screw insertion accuracy with different assisted methods: A systematic review and meta-analysis of comparative studies
-
Tian NF, Huang QS, Zhou P, et al. Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies. Eur Spine J 2011; 20: 846-59.
-
(2011)
Eur Spine J
, vol.20
, pp. 846-859
-
-
Tian, N.F.1
Huang, Q.S.2
Zhou, P.3
-
35
-
-
0034491195
-
Computer-assisted fluoroscopic targeting system for pedicle screw insertion
-
Choi WW, Green BA, Levi AD. Computer-assisted fluoroscopic targeting system for pedicle screw insertion. Neurosurgery 2000; 47: 872-8. (Pubitemid 32103663)
-
(2000)
Neurosurgery
, vol.47
, Issue.4
, pp. 872-878
-
-
Choi, W.W.1
Green, B.A.2
Levi, A.D.O.3
-
36
-
-
0035865652
-
Virtual fluoroscopy: Computer-assisted fluoroscopic navigation
-
DOI 10.1097/00007632-200102150-00009
-
Foley KT, Simon DA, Rampersaud YR. Virtual fluoroscopy: computer-assisted fluoroscopic navigation. Spine (Phila Pa 1976) 2001; 26: 347-51. (Pubitemid 32184846)
-
(2001)
Spine
, vol.26
, Issue.4
, pp. 347-351
-
-
Foley, K.T.1
Simon, D.A.2
Rampersaud, Y.R.3
-
37
-
-
79955595783
-
Pedicle screw insertion in the thoracolumbar spine: Comparison of 4 guidance techniques in the intact cadaveric spine
-
Alhabib H, Nataraj A, Khashab M, et al. Pedicle screw insertion in the thoracolumbar spine: comparison of 4 guidance techniques in the intact cadaveric spine. J Neurosurg Spine 2011; 14: 664-9.
-
(2011)
J Neurosurg Spine
, vol.14
, pp. 664-669
-
-
Alhabib, H.1
Nataraj, A.2
Khashab, M.3
-
38
-
-
18144414312
-
Use of intraoperative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement: Case report and review of the literature
-
DOI 10.1016/j.spinee.2004.09.012, PII S1529943004009076
-
Acosta FLJr, Thompson TL, Campbell S, et al. Use of intraop-erative isocentric C-arm 3D fluoroscopy for sextant percutaneous pedicle screw placement: case report and review of the literature. Spine J 2005; 5: 339-43. (Pubitemid 40613677)
-
(2005)
Spine Journal
, vol.5
, Issue.3
, pp. 339-343
-
-
Acosta Jr., F.L.1
Thompson, T.L.2
Campbell, S.3
Weinstein, P.R.4
Ames, C.P.5
-
39
-
-
0034667336
-
Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion
-
Rampersaud YR, Foley KT, Shen AC, et al. Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976) 2000; 25: 2637-45.
-
(2000)
Spine (Phila Pa 1976)
, vol.25
, pp. 2637-2645
-
-
Rampersaud, Y.R.1
Foley, K.T.2
Shen, A.C.3
-
40
-
-
0033102795
-
Exploring frameless stereotactic image guided surgery
-
503-5, 508-10 passim
-
Tessman C. Exploring frameless stereotactic image guided surgery. AORN J 1999; 69: 498-500, 503-5, 508-10 passim.
-
(1999)
AORN J
, vol.69
, pp. 498-500
-
-
Tessman, C.1
-
41
-
-
68349104323
-
Image-guided pedicle screw insertion accuracy: A meta-analysis
-
Tian NF, Xu HZ. Image-guided pedicle screw insertion accuracy: a meta-analysis. Int Orthop 2009; 33: 895-903.
-
(2009)
Int Orthop
, vol.33
, pp. 895-903
-
-
Tian, N.F.1
Xu, H.Z.2
-
42
-
-
35348900058
-
A comparison of two techniques in image-guided thoracic pedicle screw placement: A retrospective study of 37 patients and 277 pedicle screws
-
DOI 10.3171/spi.2007.7.4.393
-
Lekovic GP, Potts EA, Karahalios DG, et al. A comparison of two techniques in image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws. J Neurosurg Spine 2007; 7: 393-8. (Pubitemid 47584614)
-
(2007)
Journal of Neurosurgery: Spine
, vol.7
, Issue.4
, pp. 393-398
-
-
Lekovic, G.P.1
Potts, E.A.2
Karahalios, D.G.3
Hall, G.4
-
43
-
-
21244433504
-
Intraoperative Iso-C C-arm navigation in cervical spinal surgery: Review of the first 52 cases
-
Hott JS, Papadopoulos SM, Theodore N, et al. Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases. Spine (Phila Pa 1976) 2004; 29: 2856-60.
-
(2004)
Spine (Phila Pa 1976)
, vol.29
, pp. 2856-2860
-
-
Hott, J.S.1
Papadopoulos, S.M.2
Theodore, N.3
-
44
-
-
61549092238
-
Placement of thoracolumbar pedicle screws using three-dimensional image guidance: Experience in a large patient cohort
-
Nottmeier EW, Seemer W, Young PM. Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort. J Neurosurg Spine 2009; 10: 33-9.
-
(2009)
J Neurosurg Spine
, vol.10
, pp. 33-39
-
-
Nottmeier, E.W.1
Seemer, W.2
Young, P.M.3
-
45
-
-
70349142617
-
The use of navigation (BrainLAB Vector vision(2)) and intraoperative 3D imaging system (Siemens Arcadis Orbic 3D) in the treatment of gunshot wounds of the maxillofacial region
-
Grobe A, Weber C, Schmelzle R, et al. The use of navigation (BrainLAB Vector vision(2)) and intraoperative 3D imaging system (Siemens Arcadis Orbic 3D) in the treatment of gunshot wounds of the maxillofacial region. Oral Maxillofac Surg 2009; 13: 153-8.
-
(2009)
Oral Maxillofac Surg
, vol.13
, pp. 153-158
-
-
Grobe, A.1
Weber, C.2
Schmelzle, R.3
-
46
-
-
79954426998
-
A customized modular reference array clamp for navigated spine surgery
-
O'Loughlin PF, Daentzer D, Hufner T, et al. A customized modular reference array clamp for navigated spine surgery. Arch Orthop Trauma Surg 2010; 130: 1475-80.
-
(2010)
Arch Orthop Trauma Surg
, vol.130
, pp. 1475-1480
-
-
O'Loughlin, P.F.1
Daentzer, D.2
Hufner, T.3
-
47
-
-
0035065411
-
Stereotactic navigation for placement of pedicle screws in the thoracic spine
-
discussion 778-9
-
Youkilis AS, Quint DJ, McGillicuddy JE, et al. Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 2001; 48: 771-8; discussion 778-9.
-
(2001)
Neurosurgery
, vol.48
, pp. 771-778
-
-
Youkilis, A.S.1
Quint, D.J.2
McGillicuddy, J.E.3
-
48
-
-
80455150078
-
Spinal Navigation: Standard preoperative versus intraoperative computed tomography data set acquisition for computer-guidance system. Radiological and clinical study in 100 consecutive patients
-
Francesco C, Andrea C, Ortolina A, et al. Spinal Navigation: standard preoperative versus intraoperative computed tomography data set acquisition for computer-guidance system. Radiological and clinical study in 100 consecutive patients. Spine (Phila Pa 1976) 2011; 36: 2094-8.
-
(2011)
Spine (Phila Pa 1976)
, vol.36
, pp. 2094-2098
-
-
Francesco, C.1
Andrea, C.2
Ortolina, A.3
-
49
-
-
78649282684
-
Learning curve of computer-assisted navigation system in spine surgery
-
Bai YS, Zhang Y, Chen ZQ, et al. Learning curve of computer-assisted navigation system in spine surgery. Chin Med J (Engl) 2010; 123: 2989-94.
-
(2010)
Chin Med J (Engl)
, vol.123
, pp. 2989-2994
-
-
Bai, Y.S.1
Zhang, Y.2
Chen, Z.Q.3
-
50
-
-
0035865653
-
Accuracy requirements for image-guided spinal pedicle screw placement
-
DOI 10.1097/00007632-200102150-00010
-
Rampersaud YR, Simon DA, Foley KT. Accuracy requirements for image-guided spinal pedicle screw placement. Spine (Phila Pa 1976) 2001; 26: 352-9. (Pubitemid 32184847)
-
(2001)
Spine
, vol.26
, Issue.4
, pp. 352-359
-
-
Rampersaud, Y.R.1
Simon, D.A.2
Foley, K.T.3
-
51
-
-
0030915950
-
Frameless stereotactic guided neurosurgery: Clinical experience with an infrared based pointer device navigation system
-
Roessler K, Ungersboeck K, Dietrich W, et al. Frameless stereo-tactic guided neurosurgery: clinical experience with an infrared based pointer device navigation system. Acta Neurochir (Wien) 1997; 139: 551-9. (Pubitemid 27267677)
-
(1997)
Acta Neurochirurgica
, vol.139
, Issue.6
, pp. 551-559
-
-
Roessler, K.1
Ungersboeck, K.2
Dietrich, W.3
Aichholzer, M.4
Hittmeir, K.5
Matula, Ch.6
Czech, Th.7
Koos, W.Th.8
-
52
-
-
78649412164
-
Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: Retrospective study
-
Devito DP, Kaplan L, Dietl R, et al. Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study. Spine (Phila Pa 1976) 2010; 35: 2109-15.
-
(2010)
Spine (Phila Pa 1976)
, vol.35
, pp. 2109-2115
-
-
Devito, D.P.1
Kaplan, L.2
Dietl, R.3
-
53
-
-
34248573622
-
Robotic assisted spinal surgery - From concept to clinical practice
-
DOI 10.1080/10929080701243981, PII 778311583
-
Shoham M, Lieberman IH, Benzel EC, et al. Robotic assisted spinal surgery\from concept to clinical practice. Comput Aided Surg 2007; 12: 105-15. (Pubitemid 46752421)
-
(2007)
Computer Aided Surgery
, vol.12
, Issue.2
, pp. 105-115
-
-
Shoham, M.1
Lieberman, I.H.2
Benzel, E.C.3
Togawa, D.4
Zehavi, E.5
Zilberstein, B.6
Roffman, M.7
Bruskin, A.8
Fridlander, A.9
Joskowicz, L.10
Brink-Danan, S.11
Knoller, N.12
-
55
-
-
58149175397
-
Percutaneous transthoracic fenestration of an intramedullary neurenteric cyst in the thoracic spine with intraoperative magnetic resonance image navigation and thoracoscopy
-
Takahashi S, Morikawa S, Saruhashi Y, et al. Percutaneous transthoracic fenestration of an intramedullary neurenteric cyst in the thoracic spine with intraoperative magnetic resonance image navigation and thoracoscopy. J Neurosurg Spine 2008; 9: 488-92.
-
(2008)
J Neurosurg Spine
, vol.9
, pp. 488-492
-
-
Takahashi, S.1
Morikawa, S.2
Saruhashi, Y.3
-
56
-
-
0035865582
-
Initial experience with intraoperative magnetic resonance imaging in spine surgery
-
DOI 10.1097/00007632-200102150-00018
-
Woodard EJ, Leon SP, Moriarty TM, et al. Initial experience with intraoperative magnetic resonance imaging in spine surgery. Spine (Phila Pa 1976) 2001; 26: 410-7. (Pubitemid 32184855)
-
(2001)
Spine
, vol.26
, Issue.4
, pp. 410-417
-
-
Woodard, E.J.1
Leon, S.P.2
Moriarty, T.M.3
Quinones, A.4
Zamani, A.A.5
Jolesz, F.A.6
-
57
-
-
0142088540
-
Magnetic resonance imaging-guided percutaneous fenestration of a cervical intradural cyst. Case report
-
Takahashi S, Morikawa S, Egawa M, et al. Magnetic resonance imaging-guided percutaneous fenestration of a cervical intradural cyst. Case report. J Neurosurg 2003; 99 (suppl): 313-5.
-
(2003)
J Neurosurg
, vol.99
, Issue.SUPPL.
, pp. 313-315
-
-
Takahashi, S.1
Morikawa, S.2
Egawa, M.3
-
58
-
-
0036217236
-
Interventional MR-guided neuroendoscopy: A new therapeutic option for children
-
DOI 10.1053/jpsu.2002.31639
-
Balmer B, Bernays RL, Kollias SS, et al. Interventional MR-guided neuroendoscopy: a new therapeutic option for children. J Pediatr Surg 2002; 37: 668-72. (Pubitemid 34293116)
-
(2002)
Journal of Pediatric Surgery
, vol.37
, Issue.4
, pp. 668-672
-
-
Balmer, B.1
Bernays, R.L.2
Kollias, S.S.3
Yonekawa, Y.4
-
59
-
-
0034871191
-
Interactive magnetic resonance imaging-guided management of intracranial cystic lesions by using an open magnetic resonance imaging system
-
Kollias SS, Bernays RL. Interactive magnetic resonance imaging-guided management of intracranial cystic lesions by using an open magnetic resonance imaging system. J Neurosurg 2001; 95: 15-23. (Pubitemid 32799768)
-
(2001)
Journal of Neurosurgery
, vol.95
, Issue.1
, pp. 15-23
-
-
Kollias, S.S.1
Bernays, R.L.2
-
60
-
-
0034118425
-
Percutaneous aspiration of an intradural/extradural thoracic arachnoid cyst: Use of MR imaging guidance
-
Bellavia R, King JT Jr, Naheedy MH, et al. Percutaneous aspiration of an intradural/extradural thoracic arachnoid cyst: use of MR imaging guidance. J Vasc Interv Radiol 2000; 11: 369-72. (Pubitemid 30161384)
-
(2000)
Journal of Vascular and Interventional Radiology
, vol.11
, Issue.3
, pp. 369-372
-
-
Bellavia, R.1
King Jr., J.T.2
Hossain Naheedy, M.3
Lewin, J.S.4
-
62
-
-
77955969256
-
Computer-assisted spinal osteotomy: A technical note and report of four cases
-
Fujibayashi S, Neo M, Takemoto M, et al. Computer-assisted spinal osteotomy: a technical note and report of four cases. Spine (Phila Pa 1976) 2010; 35: E895-903.
-
(2010)
Spine (Phila Pa 1976)
, vol.35
-
-
Fujibayashi, S.1
Neo, M.2
Takemoto, M.3
-
63
-
-
42449116237
-
Computer-assisted surgical planning and image-guided surgical navigation in refractory adult scoliosis surgery: Case report and review of the literature
-
DOI 10.1097/BRS.0b013e31816d256e, PII 0000763220080420000023
-
Metz LN, Burch S. Computer-assisted surgical planning and image-guided surgical navigation in refractory adult scoliosis surgery: case report and review of the literature. Spine (Phila Pa 1976) 2008; 33: E287-92. (Pubitemid 351572302)
-
(2008)
Spine
, vol.33
, Issue.9
-
-
Metz, L.N.1
Burch, S.2
-
64
-
-
0035873119
-
Image-guided anterior thoracolumbar corpectomy: A report of three cases
-
DOI 10.1097/00007632-200105150-00024
-
Ohmori K, Kawaguchi Y, Kanamori M, et al. Image-guided anterior thoracolumbar corpectomy: a report of three cases. Spine (Phila Pa 1976) 2001; 26: 1197-201. (Pubitemid 32429326)
-
(2001)
Spine
, vol.26
, Issue.10
, pp. 1197-1201
-
-
Ohmori, K.1
Kawaguchi, Y.2
Kanamori, M.3
Ishihara, H.4
Takagi, H.5
Kimura, T.6
-
65
-
-
13244284587
-
Dose reduction in multislice computed tomography
-
DOI 10.1097/01.rct.0000151188.72850.0d
-
Hundt W, Rust F, Stabler A, et al. Dose reduction in multislice computed tomography. J Comput Assist Tomogr 2005; 29: 140-7. (Pubitemid 40194457)
-
(2005)
Journal of Computer Assisted Tomography
, vol.29
, Issue.1
, pp. 140-147
-
-
Hundt, W.1
Rust, F.2
Stabler, A.3
Wolff, H.4
Suess, C.5
Reiser, M.6
-
66
-
-
0029901904
-
Reducing the lifetime risk of cancer from spinal radiographs among people with adolescent idiopathic scoliosis
-
discussion 1548
-
Levy AR, Goldberg MS, Mayo NE, et al. Reducing the lifetime risk of cancer from spinal radiographs among people with adolescent idiopathic scoliosis. Spine (Phila Pa 1976) 1996; 21: 1540-7; discussion 1548.
-
(1996)
Spine (Phila Pa 1976)
, vol.21
, pp. 1540-1547
-
-
Levy, A.R.1
Goldberg, M.S.2
Mayo, N.E.3
-
67
-
-
0034007246
-
The risk of carcinogenesis from radiographs to pediatric orthopaedic patients
-
DOI 10.1097/00004694-200003000-00023
-
Bone CM, Hsieh GH. The risk of carcinogenesis from radiographs to pediatric orthopaedic patients. J Pediatr Orthop 2000; 20: 251-4. (Pubitemid 30140660)
-
(2000)
Journal of Pediatric Orthopaedics
, vol.20
, Issue.2
, pp. 251-254
-
-
Bone, C.M.1
Hsieh, G.H.2
-
68
-
-
34648826690
-
A pragmatic protocol for reduction in the metal artifact and radiation dose in multislice computed tomography of the spine: Cadaveric evaluation after cervical pedicle screw placement
-
DOI 10.1097/01.rct.0000250117.18080.d8, PII 0000472820070700000026
-
Lee IS, Kim HJ, Choi BK, et al. A pragmatic protocol for reduction in the metal artifact and radiation dose in multislice computed tomography of the spine: cadaveric evaluation after cervical pedicle screw placement. J Comput Assist Tomogr 2007; 31: 635-41. (Pubitemid 47457684)
-
(2007)
Journal of Computer Assisted Tomography
, vol.31
, Issue.4
, pp. 635-641
-
-
Lee, I.S.1
Kim, H.J.2
Choi, B.K.3
Jeong, Y.J.4
Lee, T.H.5
Moon, T.-Y.6
Won Kang, D.7
|