-
1
-
-
78049478848
-
European Resuscitation Council Guidelines for Resuscitation 2010. Section 4. Adult advanced life support
-
Deakin C.D., Nolan J.P., Soar J., et al. European Resuscitation Council Guidelines for Resuscitation 2010. Section 4. Adult advanced life support. Resuscitation 2010, 81:1305-1352.
-
(2010)
Resuscitation
, vol.81
, pp. 1305-1352
-
-
Deakin, C.D.1
Nolan, J.P.2
Soar, J.3
-
2
-
-
78349258536
-
Adult advanced cardiovascular life support: 2010 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care
-
Neumar R.W., Otto C.W., Link M.S., et al. Adult advanced cardiovascular life support: 2010 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 2010, 122(Suppl. 3):S729-S767.
-
(2010)
Circulation
, vol.122
, Issue.SUPPL. 3
-
-
Neumar, R.W.1
Otto, C.W.2
Link, M.S.3
-
3
-
-
33750173272
-
Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest
-
Edelson D.P., Abella B.S., Kramer-Johansen J., et al. Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest. Resuscitation 2006, 71:137-145.
-
(2006)
Resuscitation
, vol.71
, pp. 137-145
-
-
Edelson, D.P.1
Abella, B.S.2
Kramer-Johansen, J.3
et, A.4
-
4
-
-
63749115175
-
Development of the probability of return of spontaneous circulation in intervals without chest compressions during out-of-hospital cardiac arrest: an observational study
-
Gundersen K., Kvaløy J., Kramer-Johansen J., Steen P., Eftestøl T. Development of the probability of return of spontaneous circulation in intervals without chest compressions during out-of-hospital cardiac arrest: an observational study. BMC Med 2009, 7:6.
-
(2009)
BMC Med
, vol.7
, pp. 6
-
-
Gundersen, K.1
Kvaløy, J.2
Kramer-Johansen, J.3
Steen, P.4
Eftestøl, T.5
-
5
-
-
0037022212
-
Importance of continuous chest compressions during cardiopulmonary resuscitation: improved outcome during a simulated single Lay-Rescuer scenario
-
Kern K.B., Hilwig R.W., Berg R.A., Sanders A.B., Ewy G.A. Importance of continuous chest compressions during cardiopulmonary resuscitation: improved outcome during a simulated single Lay-Rescuer scenario. Circulation 2002, 105:645-649.
-
(2002)
Circulation
, vol.105
, pp. 645-649
-
-
Kern, K.B.1
Hilwig, R.W.2
Berg, R.A.3
Sanders, A.B.4
Ewy, G.A.5
-
6
-
-
70350015359
-
Techniques for artefact filtering from chest compression corrupted ECG signals: good, but not enough
-
Li Y., Tang W. Techniques for artefact filtering from chest compression corrupted ECG signals: good, but not enough. Resuscitation 2009, 80:1219-1220.
-
(2009)
Resuscitation
, vol.80
, pp. 1219-1220
-
-
Li, Y.1
Tang, W.2
-
7
-
-
84860467419
-
-
ILCOR. BLS-039 Worksheet for evidence-based review of science for emergency cardiac care.
-
ILCOR. BLS-039 Worksheet for evidence-based review of science for emergency cardiac care; 2010.
-
(2010)
-
-
-
8
-
-
0034329629
-
CPR artifact removal from human ECG using optimal multichannel filtering
-
Aase S., Eftestøl T., Husøy J., Sunde K., Steen P. CPR artifact removal from human ECG using optimal multichannel filtering. IEEE Trans Biomed Eng 2000, 47:1440-1449.
-
(2000)
IEEE Trans Biomed Eng
, vol.47
, pp. 1440-1449
-
-
Aase, S.1
Eftestøl, T.2
Husøy, J.3
Sunde, K.4
Steen, P.5
-
9
-
-
0035082139
-
Reducing CPR artefacts in ventricular fibrillation in vitro
-
Langhelle A., Eftestøl T., Myklebust H., Eriksen M., Holten B.T., Steen P.A., Reducing CPR artefacts in ventricular fibrillation in vitro. Resuscitation 2001, 48:279-291.
-
(2001)
Resuscitation
, vol.48
, pp. 279-291
-
-
Langhelle, A.1
Eftestøl, T.2
Myklebust, H.3
Eriksen, M.4
Holten, B.T.5
Steen, P.A.6
-
10
-
-
18144438347
-
Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithm
-
Husøy J., Eilevstjønn J., Eftestøl T., Aase S., Myklebust H., Steen P. Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithm. IEEE Trans Biomed Eng 2002, 49:1287-1298.
-
(2002)
IEEE Trans Biomed Eng
, vol.49
, pp. 1287-1298
-
-
Husøy, J.1
Eilevstjønn, J.2
Eftestøl, T.3
Aase, S.4
Myklebust, H.5
Steen, P.6
-
11
-
-
2342456424
-
Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG
-
Eilevstjønn J., Eftestøl T., Aase S.O., Myklebust H., Husoy J.H., Steen P.A. Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG. Resuscitation 2004, 61:131-141.
-
(2004)
Resuscitation
, vol.61
, pp. 131-141
-
-
Eilevstjønn, J.1
Eftestøl, T.2
Aase, S.O.3
Myklebust, H.4
Husoy, J.H.5
Steen, P.A.6
-
12
-
-
34548239764
-
Rhythm discrimination during uninterrupted CPR using motion artifact reduction system
-
Berger R.D., Palazzolo J., Halperin H. Rhythm discrimination during uninterrupted CPR using motion artifact reduction system. Resuscitation 2007, 75:145-152.
-
(2007)
Resuscitation
, vol.75
, pp. 145-152
-
-
Berger, R.D.1
Palazzolo, J.2
Halperin, H.3
-
13
-
-
37349087241
-
Removal of CPR artifacts from the ventricular fibrillation ECG by adaptive regression on lagged reference signals
-
Rheinberger K., Steinberger T., Unterkofler K., Baubin M., Klotz A., Amann A. Removal of CPR artifacts from the ventricular fibrillation ECG by adaptive regression on lagged reference signals. IEEE Trans Biomed Eng 2008, 55:130-137.
-
(2008)
IEEE Trans Biomed Eng
, vol.55
, pp. 130-137
-
-
Rheinberger, K.1
Steinberger, T.2
Unterkofler, K.3
Baubin, M.4
Klotz, A.5
Amann, A.6
-
14
-
-
63849329790
-
CPR artifact removal in ventricular fibrillation ECG signals using gabor multipliers
-
Werther T., Klotz A., Kracher G., et al. CPR artifact removal in ventricular fibrillation ECG signals using gabor multipliers. IEEE Trans Biomed Eng 2009, 56:320-327.
-
(2009)
IEEE Trans Biomed Eng
, vol.56
, pp. 320-327
-
-
Werther, T.1
Klotz, A.2
Kracher, G.3
-
15
-
-
67249099926
-
A least mean-square filter for the estimation of the cardiopulmonary resuscitation artifact based on the frequency of the compressions
-
Irusta U., Ruiz J., de Gauna S., Eftestøl T., Kramer-Johansen J. A least mean-square filter for the estimation of the cardiopulmonary resuscitation artifact based on the frequency of the compressions. IEEE Trans Biomed Eng 2009, 56:1052-1062.
-
(2009)
IEEE Trans Biomed Eng
, vol.56
, pp. 1052-1062
-
-
Irusta, U.1
Ruiz, J.2
de Gauna, S.3
Eftestøl, T.4
Kramer-Johansen, J.5
-
16
-
-
77955846089
-
Cardiopulmonary resuscitation artefact suppression using a Kalman filter and the frequency of chest compressions as the reference signal
-
Ruiz J., Irusta U., de Gauna S.R., Eftestøl T. Cardiopulmonary resuscitation artefact suppression using a Kalman filter and the frequency of chest compressions as the reference signal. Resuscitation 2010, 81:1087-1094.
-
(2010)
Resuscitation
, vol.81
, pp. 1087-1094
-
-
Ruiz, J.1
Irusta, U.2
de Gauna, S.R.3
Eftestøl, T.4
-
17
-
-
56849128246
-
Transthoracic impedance used to evaluate performance of cardiopulmonary resuscitation during out of hospital cardiac arrest
-
Stecher F.S., Olsen J., Stickney R.E., Wik L. Transthoracic impedance used to evaluate performance of cardiopulmonary resuscitation during out of hospital cardiac arrest. Resuscitation 2008, 79:432-437.
-
(2008)
Resuscitation
, vol.79
, pp. 432-437
-
-
Stecher, F.S.1
Olsen, J.2
Stickney, R.E.3
Wik, L.4
-
18
-
-
84860463216
-
Filtering of chest compression artefacts in the electrocardiogram
-
Jekova I., Krasteva V., Dotsinsky I. Filtering of chest compression artefacts in the electrocardiogram. Bioautomation 2009, 13:19-28.
-
(2009)
Bioautomation
, vol.13
, pp. 19-28
-
-
Jekova, I.1
Krasteva, V.2
Dotsinsky, I.3
-
19
-
-
0014970447
-
Response to passage of electric current through the body
-
PMID: 5155344
-
Geddes L.A., Baker L.E. Response to passage of electric current through the body. J Asso Adv Med Instrum 1971, 5:13-18. PMID: 5155344.
-
(1971)
J Asso Adv Med Instrum
, vol.5
, pp. 13-18
-
-
Geddes, L.A.1
Baker, L.E.2
-
20
-
-
0017293837
-
Transthoracic admittance plethysmograph for measuring cardiac output
-
Ito H., Yamakoshi K.I., Togawa T. Transthoracic admittance plethysmograph for measuring cardiac output. J Appl Physiol 1976, 40:451-454.
-
(1976)
J Appl Physiol
, vol.40
, pp. 451-454
-
-
Ito, H.1
Yamakoshi, K.I.2
Togawa, T.3
-
21
-
-
0032401226
-
The transthoracic impedance cardiogram is a potential haemodynamic sensor for an automated external defibrillator
-
Johnston P., Imam Z., Dempsey G., Anderson J., Adgey A. The transthoracic impedance cardiogram is a potential haemodynamic sensor for an automated external defibrillator. Eur Heart J 1998, 19:1879-1888.
-
(1998)
Eur Heart J
, vol.19
, pp. 1879-1888
-
-
Johnston, P.1
Imam, Z.2
Dempsey, G.3
Anderson, J.4
Adgey, A.5
-
22
-
-
0036214071
-
Expanding automatic external defibrillators to include automated detection of cardiac, respiratory, and cardiorespiratory arrest
-
PMID: 11953646
-
Pellis T., Bisera J., Tang W., Weil M.H. Expanding automatic external defibrillators to include automated detection of cardiac, respiratory, and cardiorespiratory arrest. Crit Care Med 2002, 30(Suppl.):S176-S178. PMID: 11953646.
-
(2002)
Crit Care Med
, vol.30
, Issue.SUPPL.
-
-
Pellis, T.1
Bisera, J.2
Tang, W.3
Weil, M.H.4
-
23
-
-
34147102881
-
Thoracic-impedance changes measured via defibrillator pads can monitor signs of circulation
-
Losert H., Risdal M., Sterz F., et al. Thoracic-impedance changes measured via defibrillator pads can monitor signs of circulation. Resuscitation 2007, 73:221-228.
-
(2007)
Resuscitation
, vol.73
, pp. 221-228
-
-
Losert, H.1
Risdal, M.2
Sterz, F.3
-
24
-
-
36448937826
-
Impedance-based ventilation detection during cardiopulmonary resuscitation
-
Risdal M., Aase S., Stavland M., Eftestøl T. Impedance-based ventilation detection during cardiopulmonary resuscitation. IEEE Trans Biomed Eng 2007, 54:2237-2245.
-
(2007)
IEEE Trans Biomed Eng
, vol.54
, pp. 2237-2245
-
-
Risdal, M.1
Aase, S.2
Stavland, M.3
Eftestøl, T.4
-
25
-
-
12244295495
-
Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest
-
Wik L., Kramer-Johansen J., Myklebust H., et al. Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest. JAMA 2005, 293:299-304.
-
(2005)
JAMA
, vol.293
, pp. 299-304
-
-
Wik, L.1
Kramer-Johansen, J.2
Myklebust, H.3
-
26
-
-
33751254313
-
Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study
-
Kramer-Johansen J., Myklebust H., Wik L., et al. Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study. Resuscitation 2006, 71:283-292.
-
(2006)
Resuscitation
, vol.71
, pp. 283-292
-
-
Kramer-Johansen, J.1
Myklebust, H.2
Wik, L.3
-
27
-
-
0036172471
-
Compression depth estimation for CPR quality assessment using DSP on accelerometer signals
-
Aase S., Myklebust H. Compression depth estimation for CPR quality assessment using DSP on accelerometer signals. IEEE Trans Biomed Eng 2002, 49:263-268.
-
(2002)
IEEE Trans Biomed Eng
, vol.49
, pp. 263-268
-
-
Aase, S.1
Myklebust, H.2
-
28
-
-
84860490981
-
Use of the transthoracic impedance to determine CPR quality parameters
-
Aramendi E., Ayala U., Irusta U., Alonso E. Use of the transthoracic impedance to determine CPR quality parameters. Resuscitation 2010, 81:S52.
-
(2010)
Resuscitation
, vol.81
-
-
Aramendi, E.1
Ayala, U.2
Irusta, U.3
Alonso, E.4
-
29
-
-
38049079385
-
A method to remove CPR artefacts from human ECG using only the recorded ECG
-
de Gauna S.R., Ruiz J., Irusta U., Aramendi E., Eftestøl T., Kramer-Johansen J. A method to remove CPR artefacts from human ECG using only the recorded ECG. Resuscitation 2008, 76:271-278.
-
(2008)
Resuscitation
, vol.76
, pp. 271-278
-
-
de Gauna, S.R.1
Ruiz, J.2
Irusta, U.3
Aramendi, E.4
Eftestøl, T.5
Kramer-Johansen, J.6
-
30
-
-
77952011416
-
Shock advisory system for heart rhythm analysis during cardiopulmonary resuscitation using a single ECG input of automated external defibrillators
-
Krasteva V., Jekova I., Dotsinsky I., Didon J. Shock advisory system for heart rhythm analysis during cardiopulmonary resuscitation using a single ECG input of automated external defibrillators. Ann Biomed Eng 2010, 38:1326-1336.
-
(2010)
Ann Biomed Eng
, vol.38
, pp. 1326-1336
-
-
Krasteva, V.1
Jekova, I.2
Dotsinsky, I.3
Didon, J.4
-
31
-
-
37549011383
-
Identifying potentially shockable rhythms without interrupting cardiopulmonary resuscitation
-
Li Y., Bisera J., Geheb F., Tang W., Weil M.H. Identifying potentially shockable rhythms without interrupting cardiopulmonary resuscitation. Crit Care Med 2008, 36:198-203.
-
(2008)
Crit Care Med
, vol.36
, pp. 198-203
-
-
Li, Y.1
Bisera, J.2
Geheb, F.3
Tang, W.4
Weil, M.H.5
-
32
-
-
16944364417
-
Automatic external defibrillators for public access defibrillation: recommendations for specifying and reporting arrhythmia analysis algorithm performance, incorporating new waveforms, and enhancing safety: a statement for health professionals from the American Heart Association task force on automatic external defibrillation, subcommittee on AED safety and efficacy
-
Kerber R.E., Becker L.B., Bourland J.D., et al. Automatic external defibrillators for public access defibrillation: recommendations for specifying and reporting arrhythmia analysis algorithm performance, incorporating new waveforms, and enhancing safety: a statement for health professionals from the American Heart Association task force on automatic external defibrillation, subcommittee on AED safety and efficacy. Circulation 1997, 95:1677-1682.
-
(1997)
Circulation
, vol.95
, pp. 1677-1682
-
-
Kerber, R.E.1
Becker, L.B.2
Bourland, J.D.3
|