-
1
-
-
0034718964
-
Outcomes of rapid defibrillation by security officers after cardiac arrest in casinos
-
Valenzuela T.D., Roe D.J., Nichol G., Clark L.L., Spaite D.W., Hardman R.G. Outcomes of rapid defibrillation by security officers after cardiac arrest in casinos. N Engl J Med 2000, 343:1206-1209.
-
(2000)
N Engl J Med
, vol.343
, pp. 1206-1209
-
-
Valenzuela, T.D.1
Roe, D.J.2
Nichol, G.3
Clark, L.L.4
Spaite, D.W.5
Hardman, R.G.6
-
2
-
-
28544432407
-
European Resuscitation Council Guidelines for Resuscitation 2005-Section 2. Adult basic life support and use of automated external defibrillators
-
Handley A.J., Koster R., Monsieurs K., Perkins G.D., Davies S., Bossaert L. European Resuscitation Council Guidelines for Resuscitation 2005-Section 2. Adult basic life support and use of automated external defibrillators. Resuscitation 2005, 67:S7-23.
-
(2005)
Resuscitation
, vol.67
-
-
Handley, A.J.1
Koster, R.2
Monsieurs, K.3
Perkins, G.D.4
Davies, S.5
Bossaert, L.6
-
3
-
-
7244232552
-
Wide variation in cardiopulmonary resuscitation interruption intervals among commercially available automated external defibrillators may affect survival despite high defibrillation efficacy
-
Snyder D., Morgan C. Wide variation in cardiopulmonary resuscitation interruption intervals among commercially available automated external defibrillators may affect survival despite high defibrillation efficacy. Crit Care Med 2004, 32:S421-S424.
-
(2004)
Crit Care Med
, vol.32
-
-
Snyder, D.1
Morgan, C.2
-
4
-
-
0037076435
-
Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest
-
Eftestøl T., Sunde K., Steen P.A. Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest. Circulation 2002, 105:2270-2273.
-
(2002)
Circulation
, vol.105
, pp. 2270-2273
-
-
Eftestøl, T.1
Sunde, K.2
Steen, P.A.3
-
5
-
-
0037118665
-
Adverse outcomes of interrupted precordial compression during automated defibrillation
-
Yu T., Weil M.H., Tang W.C., et al. Adverse outcomes of interrupted precordial compression during automated defibrillation. Circulation 2002, 106:368-372.
-
(2002)
Circulation
, vol.106
, pp. 368-372
-
-
Yu, T.1
Weil, M.H.2
Tang, W.C.3
-
6
-
-
33750173272
-
Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest
-
Edelson D.P., Abella B.S., Kramer-Johansen J., et al. Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest. Resuscitation 2006, 71:137-145.
-
(2006)
Resuscitation
, vol.71
, pp. 137-145
-
-
Edelson, D.P.1
Abella, B.S.2
Kramer-Johansen, J.3
-
7
-
-
0030901085
-
Analysis of the ventricular fibrillation ECG signal amplitude and frequency parameters as predictors of countershock success in humans
-
Strohmenger H.U., Lindner K.H., Brown C.G. Analysis of the ventricular fibrillation ECG signal amplitude and frequency parameters as predictors of countershock success in humans. Chest 1997, 111:584-589.
-
(1997)
Chest
, vol.111
, pp. 584-589
-
-
Strohmenger, H.U.1
Lindner, K.H.2
Brown, C.G.3
-
8
-
-
0035082139
-
Reducing CPR artefacts in ventricular fibrillation in vitro
-
Langhelle A., Eftestøl T., Myklebust H., Eriksen M., Holten B.T., Steen P.A. Reducing CPR artefacts in ventricular fibrillation in vitro. Resuscitation 2001, 48:279-291.
-
(2001)
Resuscitation
, vol.48
, pp. 279-291
-
-
Langhelle, A.1
Eftestøl, T.2
Myklebust, H.3
Eriksen, M.4
Holten, B.T.5
Steen, P.A.6
-
9
-
-
33845389282
-
Detection of ventricular fibrillation in the presence of cardiopulmonary resuscitation artefacts
-
Aramendi E., de Gauna S.R., Irusta U., Ruiz J., Arcocha M.F., Ormaetxe J.M. Detection of ventricular fibrillation in the presence of cardiopulmonary resuscitation artefacts. Resuscitation 2007, 72:115-123.
-
(2007)
Resuscitation
, vol.72
, pp. 115-123
-
-
Aramendi, E.1
de Gauna, S.R.2
Irusta, U.3
Ruiz, J.4
Arcocha, M.F.5
Ormaetxe, J.M.6
-
10
-
-
0034329629
-
CPR artifact removal from human ECG using optimal multichannel filtering
-
Aase S.O., Eftestøl T., Husøy J.H., Sunde K., Steen P.A. CPR artifact removal from human ECG using optimal multichannel filtering. IEEE Trans Biomed Eng 2000, 47:1440-1449.
-
(2000)
IEEE Trans Biomed Eng
, vol.47
, pp. 1440-1449
-
-
Aase, S.O.1
Eftestøl, T.2
Husøy, J.H.3
Sunde, K.4
Steen, P.A.5
-
11
-
-
18144438347
-
Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithm
-
Husøy J.H., Eilevstjønn J., Eftestøl T., Aase S.O., Myklebust H., Steen P.A. Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithm. IEEE Trans Biomed Eng 2002, 49:1287-1298.
-
(2002)
IEEE Trans Biomed Eng
, vol.49
, pp. 1287-1298
-
-
Husøy, J.H.1
Eilevstjønn, J.2
Eftestøl, T.3
Aase, S.O.4
Myklebust, H.5
Steen, P.A.6
-
12
-
-
37349087241
-
Removal of CPR artifacts from the ventricular fibrillation ECG by adaptive regression on lagged reference signals
-
Rheinberger K., Steinberger T., Unterkofler K., Baubin M., Klotz A., Amann A. Removal of CPR artifacts from the ventricular fibrillation ECG by adaptive regression on lagged reference signals. IEEE Trans Biomed Eng 2008, 55:130-137.
-
(2008)
IEEE Trans Biomed Eng
, vol.55
, pp. 130-137
-
-
Rheinberger, K.1
Steinberger, T.2
Unterkofler, K.3
Baubin, M.4
Klotz, A.5
Amann, A.6
-
13
-
-
2342456424
-
Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG
-
Eilevstjønn J., Eftestøl T., Aase S.O., Myklebust H., Husøy J.H., Steen P.A. Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG. Resuscitation 2004, 61:131-141.
-
(2004)
Resuscitation
, vol.61
, pp. 131-141
-
-
Eilevstjønn, J.1
Eftestøl, T.2
Aase, S.O.3
Myklebust, H.4
Husøy, J.H.5
Steen, P.A.6
-
14
-
-
38049079385
-
A method to remove CPR artefacts from human ECG using only the recorded ECG
-
Ruiz de Gauna S., Ruiz J., Irusta U., Aramendi E., Eftestøl T., Kramer-Johansen J. A method to remove CPR artefacts from human ECG using only the recorded ECG. Resuscitation 2008, 76:271-278.
-
(2008)
Resuscitation
, vol.76
, pp. 271-278
-
-
Ruiz de Gauna, S.1
Ruiz, J.2
Irusta, U.3
Aramendi, E.4
Eftestøl, T.5
Kramer-Johansen, J.6
-
15
-
-
67249099926
-
A least mean square filter for the estimation of the cardiopulmonary resuscitation artifact based on the frequency of the compressions
-
Irusta U., Ruiz J., Ruiz de Gauna S., Aramendi E., Eftestøl T., Kramer-Johansen J. A least mean square filter for the estimation of the cardiopulmonary resuscitation artifact based on the frequency of the compressions. IEEE Trans Biomed Eng 2009, 56:1052-1062.
-
(2009)
IEEE Trans Biomed Eng
, vol.56
, pp. 1052-1062
-
-
Irusta, U.1
Ruiz, J.2
Ruiz de Gauna, S.3
Aramendi, E.4
Eftestøl, T.5
Kramer-Johansen, J.6
-
16
-
-
12244295495
-
Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest
-
Wik L., Kramer-Johansen J., Myklebust H., et al. Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest. JAMA 2005, 293:299-304.
-
(2005)
JAMA
, vol.293
, pp. 299-304
-
-
Wik, L.1
Kramer-Johansen, J.2
Myklebust, H.3
-
17
-
-
33751254313
-
Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study
-
Kramer-Johansen J., Myklebust H., Wik L., et al. Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: a prospective interventional study. Resuscitation 2006, 71:283-292.
-
(2006)
Resuscitation
, vol.71
, pp. 283-292
-
-
Kramer-Johansen, J.1
Myklebust, H.2
Wik, L.3
-
18
-
-
0032377357
-
Approximate is better than " exact" for interval estimation of binomial proportions
-
Agresti A., Coull B.A. Approximate is better than " exact" for interval estimation of binomial proportions. Am Statist 1998, 52:119-126.
-
(1998)
Am Statist
, vol.52
, pp. 119-126
-
-
Agresti, A.1
Coull, B.A.2
-
19
-
-
16944364417
-
Automatic external defibrillators for public access defibrillation: recommendations for specifying and reporting arrhythmia analysis algorithm performance, incorporating new waveforms and enhancing safety. A statement for health professionals from the American Heart Association Task Force on automatic external defibrillation subcommittee on AED safety and efficacy
-
Kerber R.E., Becker L.B., Bourland J.D., et al. Automatic external defibrillators for public access defibrillation: recommendations for specifying and reporting arrhythmia analysis algorithm performance, incorporating new waveforms and enhancing safety. A statement for health professionals from the American Heart Association Task Force on automatic external defibrillation subcommittee on AED safety and efficacy. Circulation 1997, 95:1677-1682.
-
(1997)
Circulation
, vol.95
, pp. 1677-1682
-
-
Kerber, R.E.1
Becker, L.B.2
Bourland, J.D.3
-
20
-
-
37549011383
-
Identifying potentially shockable rhythms without interrupting cardiopulmonary resuscitation
-
Li Y., Bisera J., Geheb F., Tang V., Weil M.H. Identifying potentially shockable rhythms without interrupting cardiopulmonary resuscitation. Crit Care Med 2008, 36:198-203.
-
(2008)
Crit Care Med
, vol.36
, pp. 198-203
-
-
Li, Y.1
Bisera, J.2
Geheb, F.3
Tang, V.4
Weil, M.H.5
-
21
-
-
56949103367
-
Improving countershock success prediction during cardiopulmonary resuscitation using ventricular fibrillation features from higher ECG frequency bands
-
Neurauter A., Eftestøl T., Kramer-Johansen J., et al. Improving countershock success prediction during cardiopulmonary resuscitation using ventricular fibrillation features from higher ECG frequency bands. Resuscitation 2008, 79:453-459.
-
(2008)
Resuscitation
, vol.79
, pp. 453-459
-
-
Neurauter, A.1
Eftestøl, T.2
Kramer-Johansen, J.3
-
22
-
-
0037132575
-
Changing incidence of out-of-hospital ventricular fibrillation 1980-2000
-
Cobb L.A., Fahrenbruch C.E., Olsufka M., Copass M.K. Changing incidence of out-of-hospital ventricular fibrillation 1980-2000. JAMA 2002, 288:3008-3013.
-
(2002)
JAMA
, vol.288
, pp. 3008-3013
-
-
Cobb, L.A.1
Fahrenbruch, C.E.2
Olsufka, M.3
Copass, M.K.4
|