메뉴 건너뛰기




Volumn 61, Issue 2, 2004, Pages 131-141

Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG

Author keywords

Arrhythmia; Arritmia; Automated external defibrillators (AED); Cardiac arrest; CPR artefact filtering; CPR extra hospitalar; Desfibrilhadores Autom ticos Externos (AED); Electrocardiography; Heart arrest; Out of hospital CPR; Paragem Card aca

Indexed keywords

ALGORITHM; ARTICLE; CONTROLLED STUDY; DEFIBRILLATION; DEFIBRILLATOR; ELECTROCARDIOGRAM; FEASIBILITY STUDY; FILTER; HEART ARREST; HEART RHYTHM; HUMAN; MAJOR CLINICAL STUDY; MATHEMATICAL COMPUTING; OUTPATIENT CARE; PRIORITY JOURNAL; RESUSCITATION; SENSITIVITY ANALYSIS; SHOCK WAVE;

EID: 2342456424     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2003.12.019     Document Type: Article
Times cited : (87)

References (17)
  • 1
  • 2
    • 0037118665 scopus 로고    scopus 로고
    • Adverse outcomes of interrupted precordial compression during automated defibrillation
    • Yu T., Weil M.H., Tang W., et al. Adverse outcomes of interrupted precordial compression during automated defibrillation. Circulation. 106(3):2002;368-372
    • (2002) Circulation , vol.106 , Issue.3 , pp. 368-372
    • Yu, T.1    Weil, M.H.2    Tang, W.3
  • 3
    • 0037076435 scopus 로고    scopus 로고
    • Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest
    • Eftestøl T., Sunde K., Steen P.A. Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest. Circulation. 105(19):2002;2270-2273
    • (2002) Circulation , vol.105 , Issue.19 , pp. 2270-2273
    • Eftestøl, T.1    Sunde, K.2    Steen, P.A.3
  • 4
    • 0030989271 scopus 로고    scopus 로고
    • Adverse effects of interrupting precordial compression during cardiopulmonary resuscitation
    • Sato Y., Weil M.H., Sun S., et al. Adverse effects of interrupting precordial compression during cardiopulmonary resuscitation. Crit. Care Med. 25:1997;733-736
    • (1997) Crit. Care Med. , vol.25 , pp. 733-736
    • Sato, Y.1    Weil, M.H.2    Sun, S.3
  • 5
    • 0036218406 scopus 로고    scopus 로고
    • Determination of the noise source in the electrocardiogram during cardiopulmonary resuscitation
    • Fitzgibbon E., Berger R., Tsitlik J., Halperin H.R. Determination of the noise source in the electrocardiogram during cardiopulmonary resuscitation. Crit. Care Med. 30(Suppl. 4):2002;S148-53
    • (2002) Crit. Care Med. , vol.30 , Issue.SUPPL. 4 , pp. 148-153
    • Fitzgibbon, E.1    Berger, R.2    Tsitlik, J.3    Halperin, H.R.4
  • 7
    • 0030448890 scopus 로고    scopus 로고
    • Spectral analysis of ventricular fibrillation and closed-chest cardiopulmonary resuscitation
    • Strohmenger H.-U., Lindner K.H., Keller A., Pfenninger E.G. Spectral analysis of ventricular fibrillation and closed-chest cardiopulmonary resuscitation. Resuscitation. 33:1996;155-161
    • (1996) Resuscitation , vol.33 , pp. 155-161
    • Strohmenger, H.-U.1    Lindner, K.H.2    Keller, A.3    Pfenninger, E.G.4
  • 8
    • 0032941906 scopus 로고    scopus 로고
    • Electrocardiographic prediction of the success of cardiac resuscitation
    • Noc M., Weil M.H., Tang W., Sun S.J., Pernat A., Bisera J. Electrocardiographic prediction of the success of cardiac resuscitation. Crit. Care Med. 27:1999;708-714
    • (1999) Crit. Care Med. , vol.27 , pp. 708-714
    • Noc, M.1    Weil, M.H.2    Tang, W.3    Sun, S.J.4    Pernat, A.5    Bisera, J.6
  • 9
    • 0030901085 scopus 로고    scopus 로고
    • Analysis of the ventricular fibrillation ECG signal amplitude and frequency parameters as predictors of countershock success in humans
    • Strohmenger H.-U., Aalen O., Brown C.G. Analysis of the ventricular fibrillation ECG signal amplitude and frequency parameters as predictors of countershock success in humans. Chest. 111:1997;584-589
    • (1997) Chest , vol.111 , pp. 584-589
    • Strohmenger, H.-U.1    Aalen, O.2    Brown, C.G.3
  • 11
    • 18144438347 scopus 로고    scopus 로고
    • Removal of cardiopulmonary resuscitation artefacts from human ECG using an efficient matching pursuit-like algorithm
    • Husøy J.H., Eilevstjønn J., Eftestøl T., Aase S.O., Myklebust H., Steen P.A. Removal of cardiopulmonary resuscitation artefacts from human ECG using an efficient matching pursuit-like algorithm. IEEE Trans. Biomed. Eng. 49(11):2002;1287-1298
    • (2002) IEEE Trans. Biomed. Eng. , vol.49 , Issue.11 , pp. 1287-1298
    • Husøy, J.H.1    Eilevstjønn, J.2    Eftestøl, T.3    Aase, S.O.4    Myklebust, H.5    Steen, P.A.6
  • 12
    • 0034702725 scopus 로고    scopus 로고
    • Guidelines 2000 for cardiopulmonary resuscitation and emergency cardiovascular care
    • Guidelines 2000 for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 2000;102:I-1-I-403.
    • (2000) Circulation , vol.102
  • 13
    • 0036172471 scopus 로고    scopus 로고
    • Compression depth estimation for CPR quality assessment using DSP on accelerometer signals
    • Aase S.O., Myklebust H. Compression depth estimation for CPR quality assessment using DSP on accelerometer signals. IEEE Trans. Biomed. Eng. 49(3):2002;263-268
    • (2002) IEEE Trans. Biomed. Eng. , vol.49 , Issue.3 , pp. 263-268
    • Aase, S.O.1    Myklebust, H.2
  • 15
    • 0029024306 scopus 로고
    • Assessment of the ventricular fibrillation detection algorithm in the semi-automatic cardio-aid defibrillator
    • Murray A., Clayton R.H., Campbell R.W. Assessment of the ventricular fibrillation detection algorithm in the semi-automatic cardio-aid defibrillator. Resuscitation. 29:1995;113-117
    • (1995) Resuscitation , vol.29 , pp. 113-117
    • Murray, A.1    Clayton, R.H.2    Campbell, R.W.3
  • 16
    • 0027433596 scopus 로고
    • Comparative assessment of the ventricular fibrillation detection algorithms in five semi-automatic or advisory defibrillators
    • Murray A., Clayton R.H., Campbell R.W. Comparative assessment of the ventricular fibrillation detection algorithms in five semi-automatic or advisory defibrillators. Resuscitation. 26:1993;163-172
    • (1993) Resuscitation , vol.26 , pp. 163-172
    • Murray, A.1    Clayton, R.H.2    Campbell, R.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.