메뉴 건너뛰기




Volumn 75, Issue 1, 2007, Pages 145-152

Rhythm discrimination during uninterrupted CPR using motion artifact reduction system

Author keywords

Arrhythmia; Defibrillation; Electrocardiography; Resuscitation

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; ASYSTOLE; CONTROLLED STUDY; DEFIBRILLATION; DEFIBRILLATOR; ELECTROCARDIOGRAPHY MONITORING; FEMALE; HEART RHYTHM; HEART VENTRICLE FIBRILLATION; MALE; METHODOLOGY; NONHUMAN; PRIORITY JOURNAL; RESUSCITATION; SWINE; WAVEFORM;

EID: 34548239764     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2007.03.007     Document Type: Article
Times cited : (43)

References (33)
  • 1
    • 0037118665 scopus 로고    scopus 로고
    • Adverse outcomes of interrupted precordial compression during automated defibrillation
    • Yu T., Weil M.H., Tang W., et al. Adverse outcomes of interrupted precordial compression during automated defibrillation. Circulation 106 (2002) 368-372
    • (2002) Circulation , vol.106 , pp. 368-372
    • Yu, T.1    Weil, M.H.2    Tang, W.3
  • 2
    • 0030989271 scopus 로고    scopus 로고
    • Adverse effects of interrupting precordial compression during cardiopulmonary resuscitation
    • Sato Y., Weil M.H., Sun S., et al. Adverse effects of interrupting precordial compression during cardiopulmonary resuscitation. Crit Care Med 25 (1997) 733-736
    • (1997) Crit Care Med , vol.25 , pp. 733-736
    • Sato, Y.1    Weil, M.H.2    Sun, S.3
  • 3
    • 22844451287 scopus 로고    scopus 로고
    • Automated external defibrillators: to what extent does the algorithm delay CPR?
    • Rea T.D., Shah S., Kudenchuk P.J., Copass M.K., and Cobb L.A. Automated external defibrillators: to what extent does the algorithm delay CPR?. Ann Emerg Med 46 (2005) 132-141
    • (2005) Ann Emerg Med , vol.46 , pp. 132-141
    • Rea, T.D.1    Shah, S.2    Kudenchuk, P.J.3    Copass, M.K.4    Cobb, L.A.5
  • 4
    • 7244232552 scopus 로고    scopus 로고
    • Wide variation in cardiopulmonary resuscitation interruption intervals among commercially available automated external defibrillators may affect survival despite high defibrillation efficacy
    • Snyder D., and Morgan C. Wide variation in cardiopulmonary resuscitation interruption intervals among commercially available automated external defibrillators may affect survival despite high defibrillation efficacy. Crit Care Med 32 (2004) S421-S424
    • (2004) Crit Care Med , vol.32
    • Snyder, D.1    Morgan, C.2
  • 5
    • 24644452986 scopus 로고    scopus 로고
    • Interruptions of chest compressions during emergency medical systems resuscitation
    • Valenzuela T.D., Kern K.B., Clark L.L., et al. Interruptions of chest compressions during emergency medical systems resuscitation. Circulation 112 (2005) 1259-1265
    • (2005) Circulation , vol.112 , pp. 1259-1265
    • Valenzuela, T.D.1    Kern, K.B.2    Clark, L.L.3
  • 6
    • 0041953548 scopus 로고    scopus 로고
    • Interruption of cardiopulmonary resuscitation with the use of the automated external defibrillator in out-of-hospital cardiac arrest
    • van Alem A.P., Sanou B.T., and Koster R.W. Interruption of cardiopulmonary resuscitation with the use of the automated external defibrillator in out-of-hospital cardiac arrest. Ann Emerg Med 42 (2003) 449-457
    • (2003) Ann Emerg Med , vol.42 , pp. 449-457
    • van Alem, A.P.1    Sanou, B.T.2    Koster, R.W.3
  • 7
    • 0015035795 scopus 로고
    • System identification-survey
    • Astrom K.J., and Eykhoff P. System identification-survey. Automatica 7 (1971) 123-162
    • (1971) Automatica , vol.7 , pp. 123-162
    • Astrom, K.J.1    Eykhoff, P.2
  • 8
    • 28444447937 scopus 로고    scopus 로고
    • 2005 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Part 4: Advanced life support. Resuscitation 2005;67:213-47.
  • 9
    • 0036218406 scopus 로고    scopus 로고
    • Determination of the noise source in the electrocardiogram during cardiopulmonary resuscitation
    • Fitzgibbon E., Berger R., Tsitlik J., and Halperin H.R. Determination of the noise source in the electrocardiogram during cardiopulmonary resuscitation. Crit Care Med 30 (2002) S148-S153
    • (2002) Crit Care Med , vol.30
    • Fitzgibbon, E.1    Berger, R.2    Tsitlik, J.3    Halperin, H.R.4
  • 10
    • 0030901085 scopus 로고    scopus 로고
    • Analysis of the ventricular fibrillation ECG signal amplitude and frequency parameters as predictors of countershock success in humans
    • Strohmenger H.U., Lindner K.H., and Brown C.G. Analysis of the ventricular fibrillation ECG signal amplitude and frequency parameters as predictors of countershock success in humans. Chest 111 (1997) 584-589
    • (1997) Chest , vol.111 , pp. 584-589
    • Strohmenger, H.U.1    Lindner, K.H.2    Brown, C.G.3
  • 11
    • 0030448890 scopus 로고    scopus 로고
    • Spectral analysis of ventricular fibrillation and closed-chest cardiopulmonary resuscitation
    • Strohmenger H.U., Lindner K.H., Keller A., Lindner I.M., and Pfenninger E.G. Spectral analysis of ventricular fibrillation and closed-chest cardiopulmonary resuscitation. Resuscitation 33 (1996) 155-161
    • (1996) Resuscitation , vol.33 , pp. 155-161
    • Strohmenger, H.U.1    Lindner, K.H.2    Keller, A.3    Lindner, I.M.4    Pfenninger, E.G.5
  • 12
    • 0035082139 scopus 로고    scopus 로고
    • CPR artefacts in ventricular fibrillation in vitro
    • Langhelle A., Eftestol T., Myklebust H., et al. CPR artefacts in ventricular fibrillation in vitro. Resuscitation 48 (2001) 279-291
    • (2001) Resuscitation , vol.48 , pp. 279-291
    • Langhelle, A.1    Eftestol, T.2    Myklebust, H.3
  • 13
    • 0026203883 scopus 로고
    • Applications of adaptive filtering to ECG analysis-noise cancellation and arrhythmia detection
    • Thakor N.V., and Zhu Y.S. Applications of adaptive filtering to ECG analysis-noise cancellation and arrhythmia detection. IEEE Trans Biomed Eng 38 (1991) 785-794
    • (1991) IEEE Trans Biomed Eng , vol.38 , pp. 785-794
    • Thakor, N.V.1    Zhu, Y.S.2
  • 14
    • 0016643045 scopus 로고
    • Adaptive noise cancelling-principles and applications
    • Widrow B., Glover J.R., Mccool J.M., et al. Adaptive noise cancelling-principles and applications. Proc IEEE 63 (1975) 1692-1716
    • (1975) Proc IEEE , vol.63 , pp. 1692-1716
    • Widrow, B.1    Glover, J.R.2    Mccool, J.M.3
  • 15
    • 0034329629 scopus 로고    scopus 로고
    • CPR artifact removal from human ECG using optimal multichannel filtering
    • Aase S.O., Eftestol T., Husoy J.H., Sunde K., and Steen P.A. CPR artifact removal from human ECG using optimal multichannel filtering. IEEE Trans Biomed Eng 47 (2000) 1440-1449
    • (2000) IEEE Trans Biomed Eng , vol.47 , pp. 1440-1449
    • Aase, S.O.1    Eftestol, T.2    Husoy, J.H.3    Sunde, K.4    Steen, P.A.5
  • 16
    • 18144438347 scopus 로고    scopus 로고
    • Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithm
    • Husoy J.H., Eilevstjonn J., Eftestol T., Aase S.O., Myklebust H., and Steen P.A. Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithm. IEEE Trans Biomed Eng 49 (2002) 1287-1298
    • (2002) IEEE Trans Biomed Eng , vol.49 , pp. 1287-1298
    • Husoy, J.H.1    Eilevstjonn, J.2    Eftestol, T.3    Aase, S.O.4    Myklebust, H.5    Steen, P.A.6
  • 17
    • 2342456424 scopus 로고    scopus 로고
    • Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG
    • Eilevstjonn J., Eftestol T., Aase S.O., Myklebust H., Husoy J.H., and Steen P.A. Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG. Resuscitation 61 (2004) 131-141
    • (2004) Resuscitation , vol.61 , pp. 131-141
    • Eilevstjonn, J.1    Eftestol, T.2    Aase, S.O.3    Myklebust, H.4    Husoy, J.H.5    Steen, P.A.6
  • 18
    • 0036172471 scopus 로고    scopus 로고
    • Compression depth estimation for CPR quality assessment using DSP on accelerometer signals
    • Aase S.O., and Myklebust H. Compression depth estimation for CPR quality assessment using DSP on accelerometer signals. IEEE Trans Biomed Eng 49 (2002) 263-268
    • (2002) IEEE Trans Biomed Eng , vol.49 , pp. 263-268
    • Aase, S.O.1    Myklebust, H.2
  • 20
    • 0028084488 scopus 로고
    • Outcome of out-of-hospital cardiac arrest in New York City. The Pre-Hospital Arrest Survival Evaluation (PHASE) Study
    • Lombardi G., Gallagher J., and Gennis P. Outcome of out-of-hospital cardiac arrest in New York City. The Pre-Hospital Arrest Survival Evaluation (PHASE) Study. JAMA 271 (1994) 678-683
    • (1994) JAMA , vol.271 , pp. 678-683
    • Lombardi, G.1    Gallagher, J.2    Gennis, P.3
  • 21
    • 0026081895 scopus 로고
    • Outcome of CPR in a large metropolitan area-where are the survivors?
    • Becker L.B., Ostrander M.P., Barrett J., and Kondos G.T. Outcome of CPR in a large metropolitan area-where are the survivors?. Ann Emerg Med 20 (1991) 355-361
    • (1991) Ann Emerg Med , vol.20 , pp. 355-361
    • Becker, L.B.1    Ostrander, M.P.2    Barrett, J.3    Kondos, G.T.4
  • 22
    • 0032845188 scopus 로고    scopus 로고
    • A cumulative meta-analysis of the effectiveness of defibrillator-capable emergency medical services for victims of out-of-hospital cardiac arrest
    • Nichol G., Stiell I.G., Laupacis A., Pham B., De Maio V.J., and Wells G.A. A cumulative meta-analysis of the effectiveness of defibrillator-capable emergency medical services for victims of out-of-hospital cardiac arrest. Ann Emerg Med 34 (1999) 517-525
    • (1999) Ann Emerg Med , vol.34 , pp. 517-525
    • Nichol, G.1    Stiell, I.G.2    Laupacis, A.3    Pham, B.4    De Maio, V.J.5    Wells, G.A.6
  • 23
    • 0042829280 scopus 로고    scopus 로고
    • Cardiopulmonary resuscitation of adults in the hospital: a report of 14720 cardiac arrests from the National Registry of Cardiopulmonary Resuscitation
    • Peberdy M.A., Kaye W., Ornato J.P., et al. Cardiopulmonary resuscitation of adults in the hospital: a report of 14720 cardiac arrests from the National Registry of Cardiopulmonary Resuscitation. Resuscitation 58 (2003) 297-308
    • (2003) Resuscitation , vol.58 , pp. 297-308
    • Peberdy, M.A.1    Kaye, W.2    Ornato, J.P.3
  • 24
    • 33748329996 scopus 로고    scopus 로고
    • Association between interval between call for ambulance and return of spontaneous circulation and survival in out-of-hospital cardiac arrest
    • Herlitz J., Svensson L., Engdahl J., Angquist K.A., Silfverstolpe J., and Holmberg S. Association between interval between call for ambulance and return of spontaneous circulation and survival in out-of-hospital cardiac arrest. Resuscitation 71 (2006) 40-46
    • (2006) Resuscitation , vol.71 , pp. 40-46
    • Herlitz, J.1    Svensson, L.2    Engdahl, J.3    Angquist, K.A.4    Silfverstolpe, J.5    Holmberg, S.6
  • 25
    • 12244295495 scopus 로고    scopus 로고
    • Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest
    • Wik L., Kramer-Johansen J., Myklebust H., et al. Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest. JAMA 293 (2005) 299-304
    • (2005) JAMA , vol.293 , pp. 299-304
    • Wik, L.1    Kramer-Johansen, J.2    Myklebust, H.3
  • 26
    • 0029589881 scopus 로고
    • Effectiveness of bystander cardiopulmonary resuscitation and survival following out-of-hospital cardiac arrest
    • Gallagher E.J., Lombardi G., and Gennis P. Effectiveness of bystander cardiopulmonary resuscitation and survival following out-of-hospital cardiac arrest. JAMA 274 (1995) 1922-1925
    • (1995) JAMA , vol.274 , pp. 1922-1925
    • Gallagher, E.J.1    Lombardi, G.2    Gennis, P.3
  • 27
    • 0027248415 scopus 로고
    • Quality and efficiency of bystander CPR. Belgian Cerebral Resuscitation Study Group
    • Van Hoeyweghen R.J., Bossaert L.L., Mullie A., et al. Quality and efficiency of bystander CPR. Belgian Cerebral Resuscitation Study Group. Resuscitation 26 (1993) 47-52
    • (1993) Resuscitation , vol.26 , pp. 47-52
    • Van Hoeyweghen, R.J.1    Bossaert, L.L.2    Mullie, A.3
  • 28
    • 0028577625 scopus 로고
    • Quality of bystander cardiopulmonary resuscitation influences outcome after prehospital cardiac arrest
    • Wik L., Steen P.A., and Bircher N.G. Quality of bystander cardiopulmonary resuscitation influences outcome after prehospital cardiac arrest. Resuscitation 28 (1994) 195-203
    • (1994) Resuscitation , vol.28 , pp. 195-203
    • Wik, L.1    Steen, P.A.2    Bircher, N.G.3
  • 29
    • 0035856551 scopus 로고    scopus 로고
    • Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest
    • Berg R.A., Sanders A.B., Kern K.B., et al. Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest. Circulation 104 (2001) 2465-2470
    • (2001) Circulation , vol.104 , pp. 2465-2470
    • Berg, R.A.1    Sanders, A.B.2    Kern, K.B.3
  • 30
    • 0037076435 scopus 로고    scopus 로고
    • Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest
    • Eftestol T., Sunde K., and Steen P.A. Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest. Circulation 105 (2002) 2270-2273
    • (2002) Circulation , vol.105 , pp. 2270-2273
    • Eftestol, T.1    Sunde, K.2    Steen, P.A.3
  • 31
    • 12244312757 scopus 로고    scopus 로고
    • The Public Access Defibrillation (PAD) trial: study design and rationale
    • Ornato J.P., McBurnie M.A., Nichol G., et al. The Public Access Defibrillation (PAD) trial: study design and rationale. Resuscitation 56 (2003) 135-147
    • (2003) Resuscitation , vol.56 , pp. 135-147
    • Ornato, J.P.1    McBurnie, M.A.2    Nichol, G.3
  • 32
    • 33745101183 scopus 로고    scopus 로고
    • Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest: a randomized trial
    • Hallstrom A., Rea T.D., Sayre M.R., et al. Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest: a randomized trial. JAMA 295 (2006) 2620-2628
    • (2006) JAMA , vol.295 , pp. 2620-2628
    • Hallstrom, A.1    Rea, T.D.2    Sayre, M.R.3
  • 33
    • 33745065872 scopus 로고    scopus 로고
    • Use of an automated, load-distributing band chest compression device for out-of-hospital cardiac arrest resuscitation
    • Ong M.E., Ornato J.P., Edwards D.P., et al. Use of an automated, load-distributing band chest compression device for out-of-hospital cardiac arrest resuscitation. JAMA 295 (2006) 2629-2637
    • (2006) JAMA , vol.295 , pp. 2629-2637
    • Ong, M.E.1    Ornato, J.P.2    Edwards, D.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.