메뉴 건너뛰기




Volumn 76, Issue 2, 2008, Pages 271-278

A method to remove CPR artefacts from human ECG using only the recorded ECG

Author keywords

Arrhythmia; Automated external defibrillator (AED); Cardiac arrest; CPR artefact suppression; Out of hospital CPR

Indexed keywords

ALGORITHM; ARTICLE; AUTOMATED EXTERNAL DEFIBRILLATOR; CLINICAL DECISION MAKING; ELECTROCARDIOGRAM; HEART ARREST; HUMAN; PRIORITY JOURNAL; RESUSCITATION; SENSITIVITY AND SPECIFICITY;

EID: 38049079385     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2007.08.002     Document Type: Article
Times cited : (48)

References (23)
  • 1
    • 0031771844 scopus 로고    scopus 로고
    • Out-of-hospital cardiac arrests in Amsterdam and its surrounding areas: results from the Amsterdam resuscitation study (ARREST) in Utstein style
    • Waalewijn R.A., de Vos R., and Koster R.W. Out-of-hospital cardiac arrests in Amsterdam and its surrounding areas: results from the Amsterdam resuscitation study (ARREST) in Utstein style. Resuscitation 38 (1998) 157-167
    • (1998) Resuscitation , vol.38 , pp. 157-167
    • Waalewijn, R.A.1    de Vos, R.2    Koster, R.W.3
  • 2
    • 4644313810 scopus 로고    scopus 로고
    • Incidence of EMS-treated out-of-hospital cardiac arrest in the United States
    • Rea T.D., Eisenberg M.S., Sinibaldi G., and White R.D. Incidence of EMS-treated out-of-hospital cardiac arrest in the United States. Resuscitation 63 (2004) 17-24
    • (2004) Resuscitation , vol.63 , pp. 17-24
    • Rea, T.D.1    Eisenberg, M.S.2    Sinibaldi, G.3    White, R.D.4
  • 3
    • 0034718964 scopus 로고    scopus 로고
    • Outcomes of rapid defibrillation by security officers after cardiac arrest in casinos
    • Valenzuela T.D., Roe D.J., Nichol G., Clark L.L., Spaite D.W., and Hardman R.G. Outcomes of rapid defibrillation by security officers after cardiac arrest in casinos. N Engl J Med 343 (2000) 1206-1209
    • (2000) N Engl J Med , vol.343 , pp. 1206-1209
    • Valenzuela, T.D.1    Roe, D.J.2    Nichol, G.3    Clark, L.L.4    Spaite, D.W.5    Hardman, R.G.6
  • 4
    • 28544432407 scopus 로고    scopus 로고
    • European Resuscitation Council Guidelines for Resuscitation 2005 - Section 2.Adult basic life support and use of automated external defibrillators
    • Handley A.J., Koster R., Monsieurs K., Perkins G.D., Davies S., and Bossaert L. European Resuscitation Council Guidelines for Resuscitation 2005 - Section 2.Adult basic life support and use of automated external defibrillators. Resuscitation 67 (2005) S7-S23
    • (2005) Resuscitation , vol.67
    • Handley, A.J.1    Koster, R.2    Monsieurs, K.3    Perkins, G.D.4    Davies, S.5    Bossaert, L.6
  • 5
    • 0030812532 scopus 로고    scopus 로고
    • Estimating effectiveness of cardiac arrest interventions - A logistic regression survival model
    • Valenzuela T.D., Roe D.J., Cretin S., Spaite D.W., and Larsen M.P. Estimating effectiveness of cardiac arrest interventions - A logistic regression survival model. Circulation 96 (1997) 3308-3313
    • (1997) Circulation , vol.96 , pp. 3308-3313
    • Valenzuela, T.D.1    Roe, D.J.2    Cretin, S.3    Spaite, D.W.4    Larsen, M.P.5
  • 6
    • 0035184981 scopus 로고    scopus 로고
    • Survival models for out-of-hospital cardiopulmonary resuscitation from the perspectives of the bystander, the first responder, and the paramedic
    • Waalewijn R.A., de Vos R., Tijssen J.G.P., and Koster R.W. Survival models for out-of-hospital cardiopulmonary resuscitation from the perspectives of the bystander, the first responder, and the paramedic. Resuscitation 51 (2001) 113-122
    • (2001) Resuscitation , vol.51 , pp. 113-122
    • Waalewijn, R.A.1    de Vos, R.2    Tijssen, J.G.P.3    Koster, R.W.4
  • 7
    • 7244232552 scopus 로고    scopus 로고
    • Wide variation in cardiopulmonary resuscitation interruption intervals among commercially available automated external defibrillators may affect survival despite high defibrillation efficacy
    • Snyder D., and Morgan C. Wide variation in cardiopulmonary resuscitation interruption intervals among commercially available automated external defibrillators may affect survival despite high defibrillation efficacy. Crit Care Med 32 (2004) S421-S424
    • (2004) Crit Care Med , vol.32
    • Snyder, D.1    Morgan, C.2
  • 8
    • 0037076435 scopus 로고    scopus 로고
    • Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest
    • Eftestol T., Sunde K., and Steen P.A. Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest. Circulation 105 (2002) 2270-2273
    • (2002) Circulation , vol.105 , pp. 2270-2273
    • Eftestol, T.1    Sunde, K.2    Steen, P.A.3
  • 9
    • 0037118665 scopus 로고    scopus 로고
    • Adverse outcomes of interrupted precordial compression during automated defibrillation
    • Yu T., Weil M.H., Tang W.C., et al. Adverse outcomes of interrupted precordial compression during automated defibrillation. Circulation 106 (2002) 368-372
    • (2002) Circulation , vol.106 , pp. 368-372
    • Yu, T.1    Weil, M.H.2    Tang, W.C.3
  • 10
    • 33750173272 scopus 로고    scopus 로고
    • Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest
    • Edelson D.P., Abella B.S., Kramer-Johansen J., et al. Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest. Resuscitation 71 (2006) 137-145
    • (2006) Resuscitation , vol.71 , pp. 137-145
    • Edelson, D.P.1    Abella, B.S.2    Kramer-Johansen, J.3
  • 11
    • 0030901085 scopus 로고    scopus 로고
    • Analysis of the ventricular fibrillation ECG signal amplitude and frequency parameters as predictors of countershock success in humans
    • Strohmenger H.U., Lindner K.H., and Brown C.G. Analysis of the ventricular fibrillation ECG signal amplitude and frequency parameters as predictors of countershock success in humans. Chest 111 (1997) 584-589
    • (1997) Chest , vol.111 , pp. 584-589
    • Strohmenger, H.U.1    Lindner, K.H.2    Brown, C.G.3
  • 13
    • 0034329629 scopus 로고    scopus 로고
    • CPR artifact removal from human ECG using optimal multichannel filtering
    • Aase S.O., Eftestol T., Husoy J.H., Sunde K., and Steen P.A. CPR artifact removal from human ECG using optimal multichannel filtering. IEEE Trans Biomed Eng 47 (2000) 1440-1449
    • (2000) IEEE Trans Biomed Eng , vol.47 , pp. 1440-1449
    • Aase, S.O.1    Eftestol, T.2    Husoy, J.H.3    Sunde, K.4    Steen, P.A.5
  • 14
    • 18144438347 scopus 로고    scopus 로고
    • Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithm
    • Husoy J.H., Eilevstjonn J., Eftestol T., Aase S.O., Myklebust H., and Steen P.A. Removal of cardiopulmonary resuscitation artifacts from human ECG using an efficient matching pursuit-like algorithm. IEEE Trans Biomed Eng 49 (2002) 1287-1298
    • (2002) IEEE Trans Biomed Eng , vol.49 , pp. 1287-1298
    • Husoy, J.H.1    Eilevstjonn, J.2    Eftestol, T.3    Aase, S.O.4    Myklebust, H.5    Steen, P.A.6
  • 15
    • 2342456424 scopus 로고    scopus 로고
    • Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG
    • Eilevstjonn J., Eftestol T., Aase S.O., Myklebust H., Husoy J.H., and Steen P.A. Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG. Resuscitation 61 (2004) 131-141
    • (2004) Resuscitation , vol.61 , pp. 131-141
    • Eilevstjonn, J.1    Eftestol, T.2    Aase, S.O.3    Myklebust, H.4    Husoy, J.H.5    Steen, P.A.6
  • 16
    • 33845389282 scopus 로고    scopus 로고
    • Detection of ventricular fibrillation in the presence of cardiopulmonary resuscitation artefacts
    • Aramendi E., de Gauna S.R., Irusta U., Ruiz J., Arcocha M.F., and Ormaetxe J.M. Detection of ventricular fibrillation in the presence of cardiopulmonary resuscitation artefacts. Resuscitation 72 (2007) 115-123
    • (2007) Resuscitation , vol.72 , pp. 115-123
    • Aramendi, E.1    de Gauna, S.R.2    Irusta, U.3    Ruiz, J.4    Arcocha, M.F.5    Ormaetxe, J.M.6
  • 17
    • 16944364417 scopus 로고    scopus 로고
    • Automatic external defibrillators for public access defibrillation: recommendations for specifying and reporting arrhythmia analysis algorithm performance, incorporating new waveforms, and enhancing safety - A statement for health professionals from the American heart association task force on automatic external defibrillation, subcommittee on AED safety and efficacy
    • Kerber R.E., Becker L.B., and Bourland J.D. Automatic external defibrillators for public access defibrillation: recommendations for specifying and reporting arrhythmia analysis algorithm performance, incorporating new waveforms, and enhancing safety - A statement for health professionals from the American heart association task force on automatic external defibrillation, subcommittee on AED safety and efficacy. Circulation 95 (1997) 1677-1681
    • (1997) Circulation , vol.95 , pp. 1677-1681
    • Kerber, R.E.1    Becker, L.B.2    Bourland, J.D.3
  • 18
    • 12244295495 scopus 로고    scopus 로고
    • Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest
    • Wik L., Kramer-Johansen J., and Myklebust H. Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest. JAMA 293 (2005) 299-304
    • (2005) JAMA , vol.293 , pp. 299-304
    • Wik, L.1    Kramer-Johansen, J.2    Myklebust, H.3
  • 19
    • 38049002076 scopus 로고    scopus 로고
    • Ruiz J, Aramendi E, Lazkano A, Leturiondo LA, Almaraz S, inventors; Método para la detección de ritmos cardíacos desfibrilables. Spain patent 2,232,228; January 2006.
  • 20
    • 0032377357 scopus 로고    scopus 로고
    • Approximate is better than "exact" for interval estimation of binomial proportions
    • Agresti A., and Coull B.A. Approximate is better than "exact" for interval estimation of binomial proportions. Am Stat 52 (1998) 119-126
    • (1998) Am Stat , vol.52 , pp. 119-126
    • Agresti, A.1    Coull, B.A.2
  • 21
    • 0034653364 scopus 로고    scopus 로고
    • Comparing diagnostic tests: a simple graphic using likelihood ratios
    • Biggerstaff B.J. Comparing diagnostic tests: a simple graphic using likelihood ratios. Stat Med 19 (2000) 649-663
    • (2000) Stat Med , vol.19 , pp. 649-663
    • Biggerstaff, B.J.1
  • 22
    • 0037132575 scopus 로고    scopus 로고
    • Changing incidence of out-of-hospital ventricular fibrillation 1980-2000
    • Cobb L.A., Fahrenbruch C.E., Olsufka M., and Copass M.K. Changing incidence of out-of-hospital ventricular fibrillation 1980-2000. JAMA 288 (2002) 3008-3013
    • (2002) JAMA , vol.288 , pp. 3008-3013
    • Cobb, L.A.1    Fahrenbruch, C.E.2    Olsufka, M.3    Copass, M.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.