메뉴 건너뛰기




Volumn 26, Issue 8, 2011, Pages 830-835

Biomechanical evaluation of different offset versions of a cementless hip prosthesis by 3-dimensional measurement of micromotions

Author keywords

3 dimensional; Cementless; Micromotions; Neck angle; Offset; Primary stability; Total hip replacement

Indexed keywords

3-DIMENSIONAL; CEMENTLESS; MICRO MOTION; NECK ANGLE; OFFSET; PRIMARY STABILITY; TOTAL HIP REPLACEMENTS;

EID: 84860412542     PISSN: 02680033     EISSN: 18791271     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2011.04.001     Document Type: Article
Times cited : (23)

References (31)
  • 2
    • 20444365875 scopus 로고    scopus 로고
    • Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty
    • DOI 10.1016/j.arth.2004.01.016, PII S0883540305000227
    • I. Asayama, S. Chamnongkich, K.J. Simpson, T.L. Kinsey, and O.M. Mahoney Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty J. Arthroplasty 20 4 2005 414 420 (Pubitemid 40804445)
    • (2005) Journal of Arthroplasty , vol.20 , Issue.4 , pp. 414-420
    • Asayama, I.1    Chamnongkich, S.2    Simpson, K.J.3    Kinsey, T.L.4    Mahoney, O.M.5
  • 3
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in two patients
    • DOI 10.1016/0021-9290(93)90058-M
    • G. Bergmann, F. Graichen, and A. Rohlmann Hip joint loading during walking and running, measured in two patients J. Biomech. 26 8 1993 969 990 (Pubitemid 23220211)
    • (1993) Journal of Biomechanics , vol.26 , Issue.8 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 5
    • 0031105676 scopus 로고    scopus 로고
    • Three-dimensional primary stability of cementless femoral stems
    • DOI 10.1016/S0268-0033(96)00059-9, PII S0268003396000599
    • D.W. Bühler, U. Berlemann, K. Lippuner, P. Jaeger, and L.P. Nolte Three-dimensional primary stability of cementless femoral stems Clin. Biomech. 12 2 1997 75 86 (Pubitemid 27217669)
    • (1997) Clinical Biomechanics , vol.12 , Issue.2 , pp. 75-86
    • Buhler, D.W.1    Berlemann, U.2    Lippuner, K.3    Jaeger, P.4    Nolte, L.P.5
  • 7
    • 33744979310 scopus 로고    scopus 로고
    • Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems
    • DOI 10.1016/j.clinbiomech.2005.12.011, PII S0268003305003104
    • R. Decking, W. Puhl, U. Simon, and L.E. Claes Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems Clin. Biomech. 21 5 2006 495 501 (Pubitemid 44389484)
    • (2006) Clinical Biomechanics , vol.21 , Issue.5 , pp. 495-501
    • Decking, R.1    Puhl, W.2    Simon, U.3    Claes, L.E.4
  • 8
    • 64949196585 scopus 로고    scopus 로고
    • Biomechanical evaluation of two types of short-stemmed hip prostheses compared to the trust plate prosthesis by three-dimensional measurement of micromotions
    • Jun
    • A. Fottner, M. Schmid, C. Birkenmaier, F. Mazoochian, W. Plitz, and V. Jansson Biomechanical evaluation of two types of short-stemmed hip prostheses compared to the trust plate prosthesis by three-dimensional measurement of micromotions Clin. Biomech. 24 5 2009 429 434 Jun
    • (2009) Clin. Biomech. , vol.24 , Issue.5 , pp. 429-434
    • Fottner, A.1    Schmid, M.2    Birkenmaier, C.3    Mazoochian, F.4    Plitz, W.5    Jansson, V.6
  • 9
    • 77952012233 scopus 로고    scopus 로고
    • Mechanical evaluation of large-size fourth-generation composite femur and tibia models
    • Mar
    • M.P. Gardner, A.C. Chong, A.G. Pollock, and P.H. Wooley Mechanical evaluation of large-size fourth-generation composite femur and tibia models Ann. Biomed. Eng. 38 3 2010 613 620 Mar
    • (2010) Ann. Biomed. Eng. , vol.38 , Issue.3 , pp. 613-620
    • Gardner, M.P.1    Chong, A.C.2    Pollock, A.G.3    Wooley, P.H.4
  • 10
    • 0347926241 scopus 로고    scopus 로고
    • Spatial micromovements of uncemented femoral components after torsional loads
    • DOI 10.1115/1.1517565
    • W. Görtz, U.V. Nägerl, H. Nägerl, and M. Thomsen Spatial micromovements of uncemented femoral components after torsional loads J. Biomech. Eng. 124 6 2002 706 713 (Pubitemid 36119878)
    • (2002) Journal of Biomechanical Engineering , vol.124 , Issue.6 , pp. 706-713
    • Gortz, W.1    Nagerl, U.V.2    Nagerl, H.3    Thomsen, M.4
  • 11
    • 77249158849 scopus 로고    scopus 로고
    • Modular titanium alloy neck adapter failures in hip replacement-failure mode analysis and influence of implant material
    • Jan 4
    • T.M. Grupp, T. Weik, W. Bloemer, and H.P. Knaebel Modular titanium alloy neck adapter failures in hip replacement-failure mode analysis and influence of implant material BMC Musculoskelet. Disord. 11 2010 3 Jan 4
    • (2010) BMC Musculoskelet. Disord. , vol.11 , pp. 3
    • Grupp, T.M.1    Weik, T.2    Bloemer, W.3    Knaebel, H.P.4
  • 12
    • 55549145079 scopus 로고    scopus 로고
    • Structural properties of fourth-generation composite femurs and tibias
    • A.D. Heiner Structural properties of fourth-generation composite femurs and tibias J. Biomech. 41 15 2008 3282 3284
    • (2008) J. Biomech. , vol.41 , Issue.15 , pp. 3282-3284
    • Heiner, A.D.1
  • 13
    • 33644842797 scopus 로고    scopus 로고
    • Cementless stem fixation and primary stability under physiological-like loads in vitro
    • M.O. Heller, J.P. Kassi, C. Perka, and G.N. Duda Cementless stem fixation and primary stability under physiological-like loads in vitro Biomed. Tech. 50 12 2005 394 399
    • (2005) Biomed. Tech. , vol.50 , Issue.12 , pp. 394-399
    • Heller, M.O.1    Kassi, J.P.2    Perka, C.3    Duda, G.N.4
  • 14
    • 0028034860 scopus 로고
    • Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses
    • J. Kärrholm, B. Borssen, G. Löwenhielm, and F. Snorrason Does early micromotion of femoral stem prosthesis matter? 4-7-year stereoradio-graphic follow-up of 84 cemented prostheses J. Bone Joint Surg. Br. 76 6 1994 912 917 (Pubitemid 24368446)
    • (1994) Journal of Bone and Joint Surgery - Series B , vol.76 , Issue.6 , pp. 912-917
    • Karrholm, J.1    Borssen, B.2    Lowenhielm, G.3    Snorrason, F.4
  • 17
    • 15944407626 scopus 로고    scopus 로고
    • Stair climbing is more critical than walking in pre-clinical assessment of primary stability in cementless THA in vitro
    • DOI 10.1016/j.jbiomech.2004.05.023, PII S0021929004002611
    • J.P. Kassi, M.O. Heller, U. Stoeckle, C. Perka, and G.N. Duda Stair climbing is more critical than walking in pre-clinical assessment of primary stability in cementless THA in vitro J. Biomech. 38 5 2005 1143 1154 (Pubitemid 40431454)
    • (2005) Journal of Biomechanics , vol.38 , Issue.5 , pp. 1143-1154
    • Kassi, J.-P.1    Heller, M.O.2    Stoeckle, U.3    Perka, C.4    Duda, G.N.5
  • 18
    • 0042388348 scopus 로고    scopus 로고
    • THA loading arising from increased femoral anterversion and offset may lead to critical cement stresses
    • DOI 10.1016/S0736-0266(03)00040-8
    • R.U. Kleemann, M.O. Heller, U. Stoeckle, W.R. Taylor, and G.N. Duda THA loading arising from increased femoral anteversion and offset may lead to critical cement stresses J. Orthop. Res. 21 5 2003 767 774 (Pubitemid 37045552)
    • (2003) Journal of Orthopaedic Research , vol.21 , Issue.5 , pp. 767-774
    • Kleemann, R.U.1    Heller, M.O.2    Stoeckle, U.3    Taylor, W.R.4    Duda, G.N.5
  • 19
    • 70349248399 scopus 로고    scopus 로고
    • Corrosion of a hip stem with a modular neck taper junction: A retrieval study of 16 cases
    • A.M. Kop, and E. Swarts Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases J. Arthroplasty 24 7 2009 1019 1023
    • (2009) J. Arthroplasty , vol.24 , Issue.7 , pp. 1019-1023
    • Kop, A.M.1    Swarts, E.2
  • 20
    • 67349236221 scopus 로고    scopus 로고
    • Femoral offset: Anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty
    • G. Lecerf, M.H. Fessy, R. Philippot, P. Massin, F. Giraud, and X. Flecher Femoral offset: anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty Orthop. Traumatol. Surg. Res. 95 3 2009 210 219
    • (2009) Orthop. Traumatol. Surg. Res. , vol.95 , Issue.3 , pp. 210-219
    • Lecerf, G.1    Fessy, M.H.2    Philippot, R.3    Massin, P.4    Giraud, F.5    Flecher, X.6
  • 21
    • 2942597628 scopus 로고    scopus 로고
    • Leg length discrepancy after total hip arthroplasty
    • DOI 10.1016/j.arth.2004.02.018, PII S0883540304001366
    • W.J. Maloney, and J.A. Keeney Leg length discrepancy after total hip arthroplasty J. Arthroplasty 19 4 Suppl. 1 2004 108 110 (Pubitemid 38746730)
    • (2004) Journal of Arthroplasty , vol.19 , Issue.4 SUPPL. 1 , pp. 108-110
    • Maloney, W.J.1    Keeney, J.A.2
  • 23
    • 77949569941 scopus 로고    scopus 로고
    • Primary stability of custom and anatomical uncemented femoral stems: A method for three-dimensional in vitro measurement of implant stability
    • May
    • P.O. Østbyhaug, J. Klaksvik, P. Romundstad, and A. Aamodt Primary stability of custom and anatomical uncemented femoral stems: a method for three-dimensional in vitro measurement of implant stability Clin. Biomech. 25 4 2010 318 324 May
    • (2010) Clin. Biomech. , vol.25 , Issue.4 , pp. 318-324
    • Østbyhaug, P.O.1    Klaksvik, J.2    Romundstad, P.3    Aamodt, A.4
  • 25
    • 0015678773 scopus 로고
    • Short survey of mechanical stress of bone and its importance for the functional adaptation
    • Oct
    • F. Pauwels Short survey of mechanical stress of bone and its importance for the functional adaptation Z. Orthop. Ihre Grenzgeb. 111 5 1973 681 705 Oct
    • (1973) Z. Orthop. Ihre Grenzgeb. , vol.111 , Issue.5 , pp. 681-705
    • Pauwels, F.1
  • 27
    • 26844578684 scopus 로고    scopus 로고
    • Accurate femur repositioning is critical during intraoperative total hip arthroplasty length and offset assessment
    • DOI 10.1016/j.arth.2004.07.001, PII S0883540304003675
    • V.K. Sarin, W.R. Pratt, and G.W. Bradley Accurate femur repositioning is critical during intraoperative total hip arthroplasty length and offset assessment J. Arthroplasty 20 7 2005 887 891 (Pubitemid 41463689)
    • (2005) Journal of Arthroplasty , vol.20 , Issue.7 , pp. 887-891
    • Sarin, V.K.1    Pratt, W.R.2    Bradley, G.W.3
  • 28
    • 60649097092 scopus 로고    scopus 로고
    • Effect of modular neck variation on bone and cement mantle mechanics around a total hip arthroplasty stem
    • D.J. Simpson, J.P. Little, H. Gray, D.W. Murray, and H.S. Gill Effect of modular neck variation on bone and cement mantle mechanics around a total hip arthroplasty stem Clin. Biomech. 24 3 2009 274 285
    • (2009) Clin. Biomech. , vol.24 , Issue.3 , pp. 274-285
    • Simpson, D.J.1    Little, J.P.2    Gray, H.3    Murray, D.W.4    Gill, H.S.5
  • 31
    • 21444448593 scopus 로고    scopus 로고
    • The impact of the CCD-angle on range of motion and cup positioning in total hip arthroplasty
    • DOI 10.1016/j.clinbiomech.2005.04.003, PII S0268003305000884
    • K.H. Widmer, and M. Majewski The impact of the CCD-angle on range of motion and cup positioning in total hip arthroplasty Clin. Biomech. 20 7 2005 723 728 (Pubitemid 40917242)
    • (2005) Clinical Biomechanics , vol.20 , Issue.7 , pp. 723-728
    • Widmer, K.-H.1    Majewski, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.