-
1
-
-
0014983592
-
Sintered fiber metal composites as a basis for attachment of implants to bone
-
1. Galante, J. O., Rostoker, W., Lueck, R. and Ray, R. D. Sintered fiber metal composites as a basis for attachment of implants to bone. J Bone Joint Surg, 1971, 53-A, 101-114.
-
(1971)
J Bone Joint Surg
, vol.53 A
, pp. 101-114
-
-
Galante, J.O.1
Rostoker, W.2
Lueck, R.3
Ray, R.D.4
-
2
-
-
0023551378
-
Biological fixation of porous coated implants
-
2. Haddad, R. J Jr., Cook, S. D. and Thomas, K. A. Biological fixation of porous coated implants. J Bone Joint Surg, 1987; 69-A, 1459-1466.
-
(1987)
J Bone Joint Surg
, vol.69 A
, pp. 1459-1466
-
-
Haddad R.J., Jr.1
Cook, S.D.2
Thomas, K.A.3
-
3
-
-
0028344842
-
Relative motion of hip stems under load. An in vitro study of symmetrical, asymmetrical, and custom asymmetrical designs
-
3. Hua, J. and Walker, P. S. Relative motion of hip stems under load. An in vitro study of symmetrical, asymmetrical, and custom asymmetrical designs. J Bone Joint Surg, 1994, 76-A, 95-103.
-
(1994)
J Bone Joint Surg
, vol.76 A
, pp. 95-103
-
-
Hua, J.1
Walker, P.S.2
-
4
-
-
0021241442
-
Joint forces in the human pelvis-leg skeleton during walking
-
4. Röhrle, H., Scholten, R. and Sigolotto, C. et al. Joint forces in the human pelvis-leg skeleton during walking. J Biomech, 1984, 17(6), 409-424.
-
(1984)
J Biomech
, vol.17
, Issue.6
, pp. 409-424
-
-
Röhrle, H.1
Scholten, R.2
Sigolotto, C.3
-
5
-
-
0026131363
-
Comparison of the stability of press-fit hip prosthesis femoral stems using a synthetic model femur
-
5. McKellop, H., Ebramzadeh, E., Niederer, P. G. and Sarmiento, A. Comparison of the stability of press-fit hip prosthesis femoral stems using a synthetic model femur. J Orthop Res, 1991, 9, 297-305.
-
(1991)
J Orthop Res
, vol.9
, pp. 297-305
-
-
McKellop, H.1
Ebramzadeh, E.2
Niederer, P.G.3
Sarmiento, A.4
-
6
-
-
0021718314
-
Instability of total hip prostheses at rotational stress. A roentgen stereophotogrammetric study
-
6. Mjöberg B., Hansson, L. I. and Selvik, G. Instability of total hip prostheses at rotational stress. A roentgen stereophotogrammetric study. Acta Orthop Scand, 1984, 55, 504-506.
-
(1984)
Acta Orthop Scand
, vol.55
, pp. 504-506
-
-
Mjöberg, B.1
Hansson, L.I.2
Selvik, G.3
-
7
-
-
0022351417
-
Definition of endoprosthetic loosening - Comparison of arthrography, scintigraphy and roentgen stereophotogrammetry in prosthetic hips
-
7. Mjöberg, B., Brismar, J. and Hansson, L. I. et al. Definition of endoprosthetic loosening - Comparison of arthrography, scintigraphy and roentgen stereophotogrammetry in prosthetic hips. Acta Orthop Scand, 1985, 56, 469-473.
-
(1985)
Acta Orthop Scand
, vol.56
, pp. 469-473
-
-
Mjöberg, B.1
Brismar, J.2
Hansson, L.I.3
-
8
-
-
0024763433
-
A comparative study of the initial stability of cementless hip prostheses
-
8. Schneider, E., Kinast, C. and Eulenberger, J. et al. A comparative study of the initial stability of cementless hip prostheses. Clin Orthop, 1989, 248, 200-209.
-
(1989)
Clin Orthop
, vol.248
, pp. 200-209
-
-
Schneider, E.1
Kinast, C.2
Eulenberger, J.3
-
9
-
-
0003095948
-
The elimination of slip between prosthesis and femur
-
9. Charnley, J. and Kettlewell, J. The elimination of slip between prosthesis and femur. J Bone Joint Surg, 1965, 47-B, 56-60.
-
(1965)
J Bone Joint Surg
, vol.47 B
, pp. 56-60
-
-
Charnley, J.1
Kettlewell, J.2
-
10
-
-
0024498830
-
The effect of collar and distal stem fixation on micromotion of the femoral stem in uncemented total hip arthroplasty
-
10. Whiteside, L. A. and Easley, J. C. The effect of collar and distal stem fixation on micromotion of the femoral stem in uncemented total hip arthroplasty. Clin Orthop, 1989, 239, 145-153.
-
(1989)
Clin Orthop
, vol.239
, pp. 145-153
-
-
Whiteside, L.A.1
Easley, J.C.2
-
11
-
-
0026457532
-
Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses
-
11. Engh, C. A., O'Connor, D. and Jasty, M. et al. Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clin Orthop, 1982, 285, 13-29.
-
(1982)
Clin Orthop
, vol.285
, pp. 13-29
-
-
Engh, C.A.1
O'Connor, D.2
Jasty, M.3
-
12
-
-
0023574085
-
Femoral component loosening in hip arthrosplasty
-
12. Manley, M. T., Lawrence, S. S., Kotzar, G. and Stulberg, N. Femoral component loosening in hip arthrosplasty. Acta Orthop Scand, 1987, 58, 485-490.
-
(1987)
Acta Orthop Scand
, vol.58
, pp. 485-490
-
-
Manley, M.T.1
Lawrence, S.S.2
Kotzar, G.3
Stulberg, N.4
-
13
-
-
0019126005
-
The effect of calcar contact on femoral component micromovement
-
13. Markolf, K. L., Amstutz, H. C. and Hirschowitz, D. L. The effect of calcar contact on femoral component micromovement. J Bone Joint Surg, 1980, 62-A, 1315-1323.
-
(1980)
J Bone Joint Surg
, vol.62 A
, pp. 1315-1323
-
-
Markolf, K.L.1
Amstutz, H.C.2
Hirschowitz, D.L.3
-
14
-
-
0024957650
-
Examination of rotational fixation of the femoral component in total hip arthroplasty
-
14. Sugiyama, H., Whiteside, L. A. and Kaiser, A. D. Examination of rotational fixation of the femoral component in total hip arthroplasty. Clin Orthop, 1989, 249, 122-128.
-
(1989)
Clin Orthop
, vol.249
, pp. 122-128
-
-
Sugiyama, H.1
Whiteside, L.A.2
Kaiser, A.D.3
-
15
-
-
0027530299
-
Mechanical evaluation of cadaver retrieval specimens of cementless bone-ingrown total hip arthroplasty femoral components
-
15. Whiteside, L. A., White, S. E., Engh, C. A. and Head, W. Mechanical evaluation of cadaver retrieval specimens of cementless bone-ingrown total hip arthroplasty femoral components. J Arthroplasty, 1993, 8, 147-155.
-
(1993)
J Arthroplasty
, vol.8
, pp. 147-155
-
-
Whiteside, L.A.1
White, S.E.2
Engh, C.A.3
Head, W.4
-
16
-
-
0024591258
-
Torsional stability of the femoral component of hip arthroplasty. Response to an anteriorly applied load
-
16. Nunn, D., Freeman, M. A. R., Tanner, K. E. and Bonfield, W. Torsional stability of the femoral component of hip arthroplasty. Response to an anteriorly applied load. J Bone Joint Surg, 1989, 71-B, 452-455.
-
(1989)
J Bone Joint Surg
, vol.71 B
, pp. 452-455
-
-
Nunn, D.1
Freeman, M.A.R.2
Tanner, K.E.3
Bonfield, W.4
-
17
-
-
0028937350
-
Single-stage, bilateral cementless total hip arthroplasty
-
17. Ritter, M. A, Vaughn, B. K. and Frederick, L. D. Single-stage, bilateral cementless total hip arthroplasty. J Arthroplasty, 1995, 10(2), 151-156.
-
(1995)
J Arthroplasty
, vol.10
, Issue.2
, pp. 151-156
-
-
Ritter, M.A.1
Vaughn, B.K.2
Frederick, L.D.3
-
18
-
-
0028220083
-
Hip arthroplasty using cementless CLS stems - A 2-4 year experience
-
18. Robinson, R. P., Lovell, T. P. and Green, T. M. Hip arthroplasty using cementless CLS stems - a 2-4 year experience. J Arthroplasty, 1994, 9(2), 177-192.
-
(1994)
J Arthroplasty
, vol.9
, Issue.2
, pp. 177-192
-
-
Robinson, R.P.1
Lovell, T.P.2
Green, T.M.3
-
19
-
-
0025916545
-
CLS press-fit total hip arthroplasty
-
19. Blaha, J. D., Spotorno, L. and Romagnoli, S. CLS press-fit total hip arthroplasty. Techniques Orthop, 1991, 6, 80-86.
-
(1991)
Techniques Orthop
, vol.6
, pp. 80-86
-
-
Blaha, J.D.1
Spotorno, L.2
Romagnoli, S.3
-
20
-
-
0007177183
-
The CLS system, theoretical concept and results
-
20. Spotorno, L., Romagnoli, S. and Ivaldo, N. et al. The CLS system, theoretical concept and results. Acta Orthop Belg, 1993, 59, 144-148.
-
(1993)
Acta Orthop Belg
, vol.59
, pp. 144-148
-
-
Spotorno, L.1
Romagnoli, S.2
Ivaldo, N.3
-
21
-
-
0029177302
-
The use of the Wagner revision prosthesis in complex (post) traumatic conditions of the hip
-
21. Stoffeten, D. V. and Broos, P. L. The use of the Wagner revision prosthesis in complex (post) traumatic conditions of the hip. Acta Orthop Belg, 1995, 61(2), 135-139.
-
(1995)
Acta Orthop Belg
, vol.61
, Issue.2
, pp. 135-139
-
-
Stoffeten, D.V.1
Broos, P.L.2
-
22
-
-
0343052959
-
Design and evaluation of a device for measuring three-dimensional-micromotions of press-fit femoral stem prostheses
-
in press
-
22. Bühler, D. W., Oxland, T. and Nolte, L. P. Design and evaluation of a device for measuring three-dimensional-micromotions of press-fit femoral stem prostheses. Med Eng Phys (in press).
-
Med Eng Phys
-
-
Bühler, D.W.1
Oxland, T.2
Nolte, L.P.3
-
23
-
-
0012119991
-
A novel approach to image guided spine surgery
-
23. Nolte, L. P., Zamorano, L. and Langlotz, F. et al. A novel approach to image guided spine surgery. SPIE Visualization in Biomedical Computing, 1994, 2359, 564-273.
-
(1994)
SPIE Visualization in Biomedical Computing
, vol.2359
, pp. 564-1273
-
-
Nolte, L.P.1
Zamorano, L.2
Langlotz, F.3
-
24
-
-
0028060362
-
The diagnosis of osteoporosis
-
24. Kanis, J. A., Melton, L. J. H. and Christiansen, C. et al. The diagnosis of osteoporosis. J Bone Miner Res, 1994, 9, 1137-1141.
-
(1994)
J Bone Miner Res
, vol.9
, pp. 1137-1141
-
-
Kanis, J.A.1
Melton, L.J.H.2
Christiansen, C.3
-
25
-
-
0026832935
-
Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
-
25. Soballe, K., Hansen, E. S. and Rasmussen, H. et al. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res, 1991, 10, 285-299.
-
(1991)
J Orthop Res
, vol.10
, pp. 285-299
-
-
Soballe, K.1
Hansen, E.S.2
Rasmussen, H.3
-
26
-
-
0023687068
-
Histologic analysis of retrieved human porous-coated total joint components
-
26. Cook, S. D., Thomas, K. A. and Haddad, R. J. Histologic analysis of retrieved human porous-coated total joint components. Clin Orthop, 1988, 234, 90-101.
-
(1988)
Clin Orthop
, vol.234
, pp. 90-101
-
-
Cook, S.D.1
Thomas, K.A.2
Haddad, R.J.3
-
27
-
-
0026013764
-
Micromotion of cemented and uncemented femoral components
-
27. Burke, D. W., O'Connor, D. O. and Zalenski, E. B. et al. Micromotion of cemented and uncemented femoral components. J Bone Joint Surg, 1991, 73-B, 33-37.
-
(1991)
J Bone Joint Surg
, vol.73 B
, pp. 33-37
-
-
Burke, D.W.1
O'Connor, D.O.2
Zalenski, E.B.3
-
28
-
-
0022465758
-
Observations on the effect of movement on bone ingrowth into porous-surfaced implants
-
28. Pilliar, R. M., Lee, J. M. and Maniatopoulos, C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop, 1986, 208, 108-113.
-
(1986)
Clin Orthop
, vol.208
, pp. 108-113
-
-
Pilliar, R.M.1
Lee, J.M.2
Maniatopoulos, C.3
-
29
-
-
0027256183
-
The contribution of the nonporous distal stem to the stability of proximally porous-coated canine femoral components
-
29. Jasty, M., Krushell, R. and Zalenski, E. et al. The contribution of the nonporous distal stem to the stability of proximally porous-coated canine femoral components. J Arthroplasty, 1993, 8, 33-41.
-
(1993)
J Arthroplasty
, vol.8
, pp. 33-41
-
-
Jasty, M.1
Krushell, R.2
Zalenski, E.3
-
30
-
-
0026034958
-
Loosening of cementless femoral stems: A biomechanical analysis of immediate fixation with loading vertical, femur horizontal
-
30. Phillips, T. W., Nguyen, L. T. and Munro, S. D. Loosening of cementless femoral stems: a biomechanical analysis of immediate fixation with loading vertical, femur horizontal. J Biomech, 1991, 24(1), 37-48.
-
(1991)
J Biomech
, vol.24
, Issue.1
, pp. 37-48
-
-
Phillips, T.W.1
Nguyen, L.T.2
Munro, S.D.3
-
31
-
-
0003683489
-
Ergebnisse der Berechnung von Grösse und Richtung der Hüftgelenksresultierenden im Einzelfall
-
31. Hamacher, P. and Roesler, H. Ergebnisse der Berechnung von Grösse und Richtung der Hüftgelenksresultierenden im Einzelfall. Arch Orthop Unfallchir, 1972, 72(1), 94-106.
-
(1972)
Arch Orthop Unfallchir
, vol.72
, Issue.1
, pp. 94-106
-
-
Hamacher, P.1
Roesler, H.2
-
32
-
-
0013873902
-
Forces acting on the femoral head-prosthesis. A study on strain gauge supplied prostheses in living persons
-
32. Rydell, N. W. Forces acting on the femoral head-prosthesis. A study on strain gauge supplied prostheses in living persons. Acta Orthop Scand, 1966, 37(Suppl 88), 1-132.
-
(1966)
Acta Orthop Scand
, vol.37
, Issue.SUPPL. 88
, pp. 1-132
-
-
Rydell, N.W.1
-
33
-
-
0011257604
-
A force analysis of the hip joint
-
33. Williams, J. F. and Svennson, N. L. A force analysis of the hip joint. Biomed Eng, 1968, 3, 365-370.
-
(1968)
Biomed Eng
, vol.3
, pp. 365-370
-
-
Williams, J.F.1
Svennson, N.L.2
-
34
-
-
0027641060
-
Hip joint loading during walking and running, measured in two patients
-
34. Bergmann, G., Graichen, F. and Rohlmann, A. Hip joint loading during walking and running, measured in two patients. J Biomech, 1993, 26, 969-990.
-
(1993)
J Biomech
, vol.26
, pp. 969-990
-
-
Bergmann, G.1
Graichen, F.2
Rohlmann, A.3
-
35
-
-
0018565979
-
Load actions transmitted by implants
-
35. Berme, N. and Paul, J. P. Load actions transmitted by implants. J Biomed Eng, 1979, 1(4), 268-272.
-
(1979)
J Biomed Eng
, vol.1
, Issue.4
, pp. 268-272
-
-
Berme, N.1
Paul, J.P.2
-
36
-
-
0023869835
-
Telemetric force measurements across the hip after total arthroplasty
-
36. Davy, D. T., Kotzar, G. M. and Brown, R. H. et al. Telemetric force measurements across the hip after total arthroplasty. J Bone Joint Surg, 1988, 70-A, 45-50.
-
(1988)
J Bone Joint Surg
, vol.70 A
, pp. 45-50
-
-
Davy, D.T.1
Kotzar, G.M.2
Brown, R.H.3
-
37
-
-
0027400758
-
Subsidence, tip and hump micromovements of non coated ribbed femoral prostheses
-
37. Karrholm, J. and Snorrason, F. Subsidence, tip and hump micromovements of non coated ribbed femoral prostheses. Clin Orthop, 1993, 287, 50-60.
-
(1993)
Clin Orthop
, vol.287
, pp. 50-60
-
-
Karrholm, J.1
Snorrason, F.2
-
38
-
-
0018706337
-
The mechanism of fracture of the femoral prosthesis in total hip replacement
-
38. Wroblewski, B. M. The mechanism of fracture of the femoral prosthesis in total hip replacement. Intern Orthop, 1979, 3, 137-139.
-
(1979)
Intern Orthop
, vol.3
, pp. 137-139
-
-
Wroblewski, B.M.1
-
39
-
-
7344253055
-
In vivo measurement of relative motion between an uncemented femoral total hip component and the femur by roentgen stereophotogrammetry
-
San Francisco
-
39. Nistor, L., Blaha, J. D., Kjellstrom, U. and Selvik, G. In vivo measurement of relative motion between an uncemented femoral total hip component and the femur by roentgen stereophotogrammetry. Proc Orthop Res Soc, 1987, San Francisco, 485.
-
(1987)
Proc Orthop Res Soc
, pp. 485
-
-
Nistor, L.1
Blaha, J.D.2
Kjellstrom, U.3
Selvik, G.4
-
40
-
-
0026346344
-
Intraoperative measurement of rotational stability of femoral components of total hip arthroplasty
-
40. Harris, W. H., Mulroy, R. D. Jr. and Maloney, W. J. et al. Intraoperative measurement of rotational stability of femoral components of total hip arthroplasty. Clin Orthop, 1991, 266, 119-126.
-
(1991)
Clin Orthop
, vol.266
, pp. 119-126
-
-
Harris, W.H.1
Mulroy R.D., Jr.2
Maloney, W.J.3
-
41
-
-
0026832923
-
Fixation stability of femoral components in a canine hip replacement model
-
41. Vanderby, R., Manley, P. A., Kohles, S. S. and McBeath, A. A. Fixation stability of femoral components in a canine hip replacement model. J. Orthop Res, 1992, 10, 300-309.
-
(1992)
J. Orthop Res
, vol.10
, pp. 300-309
-
-
Vanderby, R.1
Manley, P.A.2
Kohles, S.S.3
McBeath, A.A.4
-
42
-
-
0023161998
-
Strains and micromotions of press-fit femoral stem prosthesis
-
42. Walker, P. S., Schneeweis, D., Murphy, S. and Nelson, P. Strains and micromotions of press-fit femoral stem prosthesis. J Biomech, 1987, 20(7), 639-702.
-
(1987)
J Biomech
, vol.20
, Issue.7
, pp. 639-702
-
-
Walker, P.S.1
Schneeweis, D.2
Murphy, S.3
Nelson, P.4
-
43
-
-
0028874286
-
The effect of the medial collar in total hip arthroplasty with porous-coated components inserted without cement
-
43. Cheng, S. L., Davey, J. R. and Inman, R.D et al. The effect of the medial collar in total hip arthroplasty with porous-coated components inserted without cement. J Bone Joint Surg, 1995, 77-A, 118-123.
-
(1995)
J Bone Joint Surg
, vol.77 A
, pp. 118-123
-
-
Cheng, S.L.1
Davey, J.R.2
Inman, R.D.3
-
44
-
-
0027438724
-
Early migration of uncemented porous coated anatomic femoral component related to aseptic loosening
-
44. Kim, Y. H. and Kim, V. E. Early migration of uncemented porous coated anatomic femoral component related to aseptic loosening. Clin Orthop, 1993, 295, 146-155.
-
(1993)
Clin Orthop
, vol.295
, pp. 146-155
-
-
Kim, Y.H.1
Kim, V.E.2
-
45
-
-
0026030397
-
Total hip arthroplasty: A comparison between cemented and press-fit noncemented fixation
-
45. Wykman, A., Olsson, E., Axdorph, G. and Goldie, I. Total hip arthroplasty: a comparison between cemented and press-fit noncemented fixation. J Arthroplasty, 1991, 6, 19-9.
-
(1991)
J Arthroplasty
, vol.6
, pp. 19-19
-
-
Wykman, A.1
Olsson, E.2
Axdorph, G.3
Goldie, I.4
-
46
-
-
0028282143
-
Early migration and late aseptic failure of proximal femoral prosthesis
-
46. Freeman, M. A. R. and Plante-Bordeneuve, P. Early migration and late aseptic failure of proximal femoral prosthesis. J Bone Joint Surg, 1993, 76-B, 432-438.
-
(1993)
J Bone Joint Surg
, vol.76 B
, pp. 432-438
-
-
Freeman, M.A.R.1
Plante-Bordeneuve, P.2
-
47
-
-
0025270925
-
Clinical and radiographic evaluation of total hip replacement
-
47. Johnston, R. C., Fitzgerald, R. H. and Harris, W. H. et al. Clinical and radiographic evaluation of total hip replacement. J Bone Joint Surg, 1990, 72-A, 161-168.
-
(1990)
J Bone Joint Surg
, vol.72 A
, pp. 161-168
-
-
Johnston, R.C.1
Fitzgerald, R.H.2
Harris, W.H.3
|