메뉴 건너뛰기




Volumn , Issue , 2006, Pages 79-101

An Overview on Bioelectronic and Biosensoric Microstructures Supporting High-Content Screening in Cell Cultures

Author keywords

Bioelectronic microstructures; Biosensoric microstructures; Cell culture technology; Drug testing; High content screening in cell cultures; Microelectrode based techniques; Microfabrication techniques; Miniaturized chip components; Screening for cost effective drug testing and discovery; Screening for safety

Indexed keywords


EID: 84859960126     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/9783527609611.ch3     Document Type: Chapter
Times cited : (2)

References (60)
  • 1
    • 23944486374 scopus 로고    scopus 로고
    • Cells on a chip - the use of electric properties for highly sensitive monitoring of blood-derived factors involved in angiotensin II type 1 receptor signalling
    • Rothermel, A., Kurz, R., Ruffer, M., Weigel, W., Jahnke, H. G., Sedello, A., Stepan, H., Faber, R., Schulze-Forster, K., and Robitzki, A. Cells on a chip - the use of electric properties for highly sensitive monitoring of blood-derived factors involved in angiotensin II type 1 receptor signalling. Cell Physiol. Biochem. 2005, 16(1-3): 51-58.
    • (2005) Cell Physiol. Biochem. , vol.16 , Issue.1-3 , pp. 51-58
    • Rothermel, A.1    Kurz, R.2    Ruffer, M.3    Weigel, W.4    Jahnke, H.G.5    Sedello, A.6    Stepan, H.7    Faber, R.8    Schulze-Forster, K.9    Robitzki, A.10
  • 2
    • 0037086859 scopus 로고    scopus 로고
    • A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices
    • Heuschkel, M. O., Fejtl, M., Raggenbass, M., Bertrand, D., and Renaud, P. A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices. J. Neurosci. Methods 2002, 114(2): 135-148.
    • (2002) J. Neurosci. Methods , vol.114 , Issue.2 , pp. 135-148
    • Heuschkel, M.O.1    Fejtl, M.2    Raggenbass, M.3    Bertrand, D.4    Renaud, P.5
  • 3
    • 2342586678 scopus 로고    scopus 로고
    • Silicon chip with capacitors and transistors for interfacing organotypic brain slice of rat hippocampus
    • Hutzler, M. and Fromherz, P. Silicon chip with capacitors and transistors for interfacing organotypic brain slice of rat hippocampus. Eur. J. Neurosci. 2004, 19(8): 2231-2238.
    • (2004) Eur. J. Neurosci. , vol.19 , Issue.8 , pp. 2231-2238
    • Hutzler, M.1    Fromherz, P.2
  • 4
    • 4444267925 scopus 로고    scopus 로고
    • Beta-adrenergic and muscarinic modulation of human embryonic stem cell-derived cardiomyocytes
    • Reppel, M., Boettinger, C., and Hescheler, J. Beta-adrenergic and muscarinic modulation of human embryonic stem cell-derived cardiomyocytes. Cell Physiol. Biochem. 2004, 14(4-6): 187-196.
    • (2004) Cell Physiol. Biochem. , vol.14 , Issue.4-6 , pp. 187-196
    • Reppel, M.1    Boettinger, C.2    Hescheler, J.3
  • 5
    • 16544386790 scopus 로고    scopus 로고
    • Recording spikes from a large fraction of the ganglion cells in a retinal patch
    • Segev, R., Goodhouse, J., Puchalla J., and Berry, M. J. II. Recording spikes from a large fraction of the ganglion cells in a retinal patch. Nat. Neurosci. 2004, 7(10): 1154-1161.
    • (2004) Nat. Neurosci. , vol.7 , Issue.10 , pp. 1154-1161
    • Segev, R.1    Goodhouse, J.2    Puchalla, J.3    Berry II, M.J.4
  • 6
    • 0242353365 scopus 로고    scopus 로고
    • Estimation of action potential changes from field potential recordings in multicellular mouse cardiac myocyte cultures
    • Halbach, M., Egert, U., Hescheler, J., and Banach, K. Estimation of action potential changes from field potential recordings in multicellular mouse cardiac myocyte cultures. Cell Physiol. Biochem. 2003, 13(5): 271-284.
    • (2003) Cell Physiol. Biochem. , vol.13 , Issue.5 , pp. 271-284
    • Halbach, M.1    Egert, U.2    Hescheler, J.3    Banach, K.4
  • 7
    • 0642340796 scopus 로고    scopus 로고
    • Backside contacted field effect transistor array for extracellular signal recording
    • Ingebrandt, S., Yeung, C. K., Staab, W., Zetterer, T., and Offenhausser, A. Backside contacted field effect transistor array for extracellular signal recording. Biosens. Bioelectron. 2003, 18(4): 429-435.
    • (2003) Biosens. Bioelectron. , vol.18 , Issue.4 , pp. 429-435
    • Ingebrandt, S.1    Yeung, C.K.2    Staab, W.3    Zetterer, T.4    Offenhausser, A.5
  • 9
    • 0347598249 scopus 로고    scopus 로고
    • Biological application of microelectrode arrays in drug discovery and basic research
    • Stett, A., Egert, U., Guenther, E., Hofmann, F., Meyer, T., Nisch, W., and Haemmerle, H. Biological application of microelectrode arrays in drug discovery and basic research. Ann. Biomol. Chem. 2003, 377(3): 486-495.
    • (2003) Ann. Biomol. Chem. , vol.377 , Issue.3 , pp. 486-495
    • Stett, A.1    Egert, U.2    Guenther, E.3    Hofmann, F.4    Meyer, T.5    Nisch, W.6    Haemmerle, H.7
  • 10
    • 26944481910 scopus 로고    scopus 로고
    • A more aggressive breast cancer spheroid model coupled to an electronic capillary sensor system for a high-content screening of cytotoxic agents in cancer therapy: 3-dimensional in vitro tumor spheroids as a screening model
    • Bartholomä, P., Impidjati, Reininger-Mack, A., Zhang, Z., Thielecke, H., and Robitzki, A. A more aggressive breast cancer spheroid model coupled to an electronic capillary sensor system for a high-content screening of cytotoxic agents in cancer therapy: 3-dimensional in vitro tumor spheroids as a screening model. J. Biomol. Screen. 2005, 10(7): 705-714.
    • (2005) J. Biomol. Screen. , vol.10 , Issue.7 , pp. 705-714
    • Bartholomä, P.1    Impidjati, R.-M.A.2    Zhang, Z.3    Thielecke, H.4    Robitzki, A.5
  • 11
    • 8844262805 scopus 로고    scopus 로고
    • Cellular dielectric spectroscopy: a powerful new approach to label-free cellular analysis
    • Ciambrone, G. J., Liu, V. F., Lin, D. C., McGuinness, R. P., Leung, G. K., and Pitchford, S. Cellular dielectric spectroscopy: a powerful new approach to label-free cellular analysis. J. Biomol. Screen. 2004, 9(6): 467-480.
    • (2004) J. Biomol. Screen. , vol.9 , Issue.6 , pp. 467-480
    • Ciambrone, G.J.1    Liu, V.F.2    Lin, D.C.3    McGuinness, R.P.4    Leung, G.K.5    Pitchford, S.6
  • 12
    • 3142667502 scopus 로고    scopus 로고
    • Biophysical methods for monitoring cell-substrate interactions in drug discovery
    • Hug, T. S. Biophysical methods for monitoring cell-substrate interactions in drug discovery. Assays Drug Dev. Technol. 2003, 1(3): 479-488.
    • (2003) Assays Drug Dev. Technol. , vol.1 , Issue.3 , pp. 479-488
    • Hug, T.S.1
  • 13
    • 1542649843 scopus 로고    scopus 로고
    • Capillary chip-based characterisation of small tissue samples
    • Thielecke, H. Capillary chip-based characterisation of small tissue samples. Med. Device Technol. 2003, 14(9): 18-20.
    • (2003) Med. Device Technol. , vol.14 , Issue.9 , pp. 18-20
    • Thielecke, H.1
  • 14
  • 15
    • 20544464212 scopus 로고    scopus 로고
    • Application of silicon sensor technologies to tumor tissue in vitro: detection of metabolic correlates of chemosensitivity
    • Mestres-Ventura, P., Morguet, A., Schofer, A., Laue, M., and Schmidt, W. Application of silicon sensor technologies to tumor tissue in vitro: detection of metabolic correlates of chemosensitivity. Methods Mol. Med. 2005, 111: 109-125.
    • (2005) Methods Mol. Med. , vol.111 , pp. 109-125
    • Mestres-Ventura, P.1    Morguet, A.2    Schofer, A.3    Laue, M.4    Schmidt, W.5
  • 16
    • 11944258702 scopus 로고    scopus 로고
    • Analysis of drug action on tumor cell metabolism using electronic sensor chips
    • Otto, A. M., Brischwein, M., Motrescu, E., and Wolf, B. Analysis of drug action on tumor cell metabolism using electronic sensor chips. Arch. Pharm. 2004, 337(12): 682-686.
    • (2004) Arch. Pharm. , vol.337 , Issue.12 , pp. 682-686
    • Otto, A.M.1    Brischwein, M.2    Motrescu, E.3    Wolf, B.4
  • 17
    • 0031820881 scopus 로고    scopus 로고
    • A unified resistor-capacitor model for impedance, dielectrophoresis, electrorotation, and induced transmembrane potential
    • Gimsa, J., and Wachner, D. A unified resistor-capacitor model for impedance, dielectrophoresis, electrorotation, and induced transmembrane potential. Biophys. J. 1998, 75(2): 1107-1116.
    • (1998) Biophys. J. , vol.75 , Issue.2 , pp. 1107-1116
    • Gimsa, J.1    Wachner, D.2
  • 18
    • 0024572263 scopus 로고
    • Dielectric properties of tissues and bio logical materials: a critical review
    • Foster, K. R. and Schwan, H. P. Dielectric properties of tissues and bio logical materials: a critical review. Crit. Rev. Biomed. Eng. 1989, 17(1): 25-104.
    • (1989) Crit. Rev. Biomed. Eng. , vol.17 , Issue.1 , pp. 25-104
    • Foster, K.R.1    Schwan, H.P.2
  • 19
    • 54949152106 scopus 로고
    • Electrical properties of tissue and cell suspensions
    • Schwan, H. P. Electrical properties of tissue and cell suspensions. Adv. Biol. Med. Phys. 1957, 5: 147-209.
    • (1957) Adv. Biol. Med. Phys. , vol.5 , pp. 147-209
    • Schwan, H.P.1
  • 20
    • 2142846185 scopus 로고
    • Monitoring fibroblast behavior in tissue culture with an applied electric field
    • Giaever, I. and Keese, C. R. Monitoring fibroblast behavior in tissue culture with an applied electric field. Proc. Natl. Acad. Sci. USA 1984, 81(12): 3761-3764.
    • (1984) Proc. Natl. Acad. Sci. USA , vol.81 , Issue.12 , pp. 3761-3764
    • Giaever, I.1    Keese, C.R.2
  • 21
    • 0346996456 scopus 로고    scopus 로고
    • Bioelectrical impedance assay to monitor changes in cell shape during apoptosis
    • Arndt, S., Seebach, J., Psathaki, K., Galla, H. J., and Wegener, J. Bioelectrical impedance assay to monitor changes in cell shape during apoptosis. Biosens. Bioelectron. 2004, 19(6): 583-594.
    • (2004) Biosens. Bioelectron. , vol.19 , Issue.6 , pp. 583-594
    • Arndt, S.1    Seebach, J.2    Psathaki, K.3    Galla, H.J.4    Wegener, J.5
  • 22
    • 0035014916 scopus 로고    scopus 로고
    • A multicellular spheroid-based sensor for anti-cancer therapeutics
    • Thielecke, H., Mack, A., and Robitzki, A. A multicellular spheroid-based sensor for anti-cancer therapeutics. Biosens. Bioelectron. 2001, 16(4-5): 261-269.
    • (2001) Biosens. Bioelectron. , vol.16 , Issue.4-5 , pp. 261-269
    • Thielecke, H.1    Mack, A.2    Robitzki, A.3
  • 23
    • 0035094284 scopus 로고    scopus 로고
    • Biohybrid microarrays - impedimetric biosensors with 3D in vitro tissues for toxicological and biomedical screening
    • Thielecke, H., Mack, A., and Robitzki, A. Biohybrid microarrays - impedimetric biosensors with 3D in vitro tissues for toxicological and biomedical screening. Fresenius J. Anal. Chem. 2001, 369(1): 23-29.
    • (2001) Fresenius J. Anal. Chem. , vol.369 , Issue.1 , pp. 23-29
    • Thielecke, H.1    Mack, A.2    Robitzki, A.3
  • 25
    • 0030472464 scopus 로고    scopus 로고
    • Double-mode impedance analysis of epithelial cell monolayers cultured on shear wave resonators
    • Janshoff, A., Wegener, J., Sieber, M., and Galla, H. J. Double-mode impedance analysis of epithelial cell monolayers cultured on shear wave resonators. Eur. Biophys. J. 1996, 25(2): 93-103.
    • (1996) Eur. Biophys. J. , vol.25 , Issue.2 , pp. 93-103
    • Janshoff, A.1    Wegener, J.2    Sieber, M.3    Galla, H.J.4
  • 26
    • 0030578217 scopus 로고    scopus 로고
    • Impedance analysis of epithelial and endothelial cell monolayers cultured on gold surfaces
    • Wegener, J., Sieber, M., and Galla, H. J. Impedance analysis of epithelial and endothelial cell monolayers cultured on gold surfaces. J. Biochem. Biophys. Methods 1996, 32(3): 151-170.
    • (1996) J. Biochem. Biophys. Methods , vol.32 , Issue.3 , pp. 151-170
    • Wegener, J.1    Sieber, M.2    Galla, H.J.3
  • 27
    • 0031843634 scopus 로고    scopus 로고
    • Basement membrane proteins infliuence brain capillary endothelial barrier function in vitro
    • Tilling, T., Korte, D., Hoheisel, D., and Galla, H. J. Basement membrane proteins infliuence brain capillary endothelial barrier function in vitro. J. Neurochem. 1998, 71(3): 1151-1157.
    • (1998) J. Neurochem. , vol.71 , Issue.3 , pp. 1151-1157
    • Tilling, T.1    Korte, D.2    Hoheisel, D.3    Galla, H.J.4
  • 28
    • 6344282698 scopus 로고    scopus 로고
    • Automated multi-well device to measure transepithelial electrical resistances under physiological conditions
    • 594+596-597
    • Wegener, J., Abrams, D., Willenbrink, W., Galla, H. J., and Janshoff, A. Automated multi-well device to measure transepithelial electrical resistances under physiological conditions. Biotechniques 2004, 37(4): 590, 592-594, 596-597.
    • (2004) Biotechniques , vol.37 , Issue.4 , pp. 590-592
    • Wegener, J.1    Abrams, D.2    Willenbrink, W.3    Galla, H.J.4    Janshoff, A.5
  • 29
    • 0033366305 scopus 로고    scopus 로고
    • Membrane transistor with giant lipid vesicle touching a silicon chip
    • Fromherz, P., Kiessling, V., Kottig, K., and Zeck. G. Membrane transistor with giant lipid vesicle touching a silicon chip. Appl. Phys. 1999, A69, 571-576.
    • (1999) Appl. Phys. , vol.A69 , pp. 571-576
    • Fromherz, P.1    Kiessling, V.2    Kottig, K.3    Zeck, G.4
  • 30
    • 0019076155 scopus 로고
    • Transmission of chemical signal by sequen tial energy and electron transfer in pigment membrane on semiconductor
    • Fromherz, P. and Arden, W. Transmission of chemical signal by sequen tial energy and electron transfer in pigment membrane on semiconductor. Ber. Bunsenges Phys. Chem. 1980, 84, 1045-1050.
    • (1980) Ber. Bunsenges Phys. Chem. , vol.84 , pp. 1045-1050
    • Fromherz, P.1    Arden, W.2
  • 31
    • 0021947327 scopus 로고
    • Supported phospholipid bilayers
    • Tam, L. K. and McConnell, H. M. Supported phospholipid bilayers. Biophys. J. 1985, 47(1): 105-113.
    • (1985) Biophys. J. , vol.47 , Issue.1 , pp. 105-113
    • Tam, L.K.1    McConnell, H.M.2
  • 32
    • 0026512750 scopus 로고
    • Formation of supported planar bilayers by fusion of vesicles to supported phospholipid monolayers
    • Kalb, E., Frey, S., and Tamm, L. K. Formation of supported planar bilayers by fusion of vesicles to supported phospholipid monolayers. Biochim. Biophys. Acta 1992, 1103(2): 307-316.
    • (1992) Biochim. Biophys. Acta , vol.1103 , Issue.2 , pp. 307-316
    • Kalb, E.1    Frey, S.2    Tamm, L.K.3
  • 33
    • 0030569732 scopus 로고    scopus 로고
    • Supported membranes: scientific and practical applications
    • Sackmann, E. Supported membranes: scientific and practical applications. Science 1996, 271(5245): 43-48.
    • (1996) Science , vol.271 , Issue.5245 , pp. 43-48
    • Sackmann, E.1
  • 34
    • 0032070193 scopus 로고    scopus 로고
    • Impedance spectroscopy of porin and gramicidin pores reconstituted into supported lipid bilayers on indium-tin-oxide electrodes
    • Gritsch, S., Nollert, P., Jähnig, F., and Sackmann, E. Impedance spectroscopy of porin and gramicidin pores reconstituted into supported lipid bilayers on indium-tin-oxide electrodes. Langmuir 1998, 14(11): 3118-3125.
    • (1998) Langmuir , vol.14 , Issue.11 , pp. 3118-3125
    • Gritsch, S.1    Nollert, P.2    Jähnig, F.3    Sackmann, E.4
  • 35
    • 0032823307 scopus 로고    scopus 로고
    • Voltage-gated ion channels and hereditary disease
    • Lehmann-Horn, F. and Jurkat-Rott, K. Voltage-gated ion channels and hereditary disease. Physiol. Rev. 1999, 79(4): 1317-1372.
    • (1999) Physiol. Rev. , vol.79 , Issue.4 , pp. 1317-1372
    • Lehmann-Horn, F.1    Jurkat-Rott, K.2
  • 36
    • 0017258698 scopus 로고
    • Single-channel currents recorded from membrane of denervated frog muscle fibres
    • Neher, E. and Sakmann, B. Single-channel currents recorded from membrane of denervated frog muscle fibres. Nature 1976, 260(5554): 799-802.
    • (1976) Nature , vol.260 , Issue.5554 , pp. 799-802
    • Neher, E.1    Sakmann, B.2
  • 37
    • 0037234427 scopus 로고    scopus 로고
    • Flip the tip: an automated, high quality, cost-effective patch clamp screen
    • Lepple-Wienhues, A., Ferlinz, K., Seeger, A., and Schafer, A. Flip the tip: an automated, high quality, cost-effective patch clamp screen. Receptors Channels 2003, 9(1): 13-17.
    • (2003) Receptors Channels , vol.9 , Issue.1 , pp. 13-17
    • Lepple-Wienhues, A.1    Ferlinz, K.2    Seeger, A.3    Schafer, A.4
  • 41
    • 2942567934 scopus 로고    scopus 로고
    • Automated high-throughput patch-clamp techniques
    • Shieh, C. C. Automated high-throughput patch-clamp techniques. Drug Discov. Today 2004, 9(13): 551-552.
    • (2004) Drug Discov. Today , vol.9 , Issue.13 , pp. 551-552
    • Shieh, C.C.1
  • 42
    • 10244264821 scopus 로고    scopus 로고
    • High throughput assay technologies for ion channel drug discovery
    • Zheng, W., Spencer, R. H., and Kiss, L. High throughput assay technologies for ion channel drug discovery. Assay Drug Dev. Technol. 2004, 2(5): 543-552.
    • (2004) Assay Drug Dev. Technol. , vol.2 , Issue.5 , pp. 543-552
    • Zheng, W.1    Spencer, R.H.2    Kiss, L.3
  • 43
    • 22444443481 scopus 로고    scopus 로고
    • Automated electrophysiology in the preclinical evaluation of drugs for potential QT prolongation
    • Guo, L. and Guthrie, H. Automated electrophysiology in the preclinical evaluation of drugs for potential QT prolongation. J. Pharmacol. Toxicol. Methods 2005, 52(1): 123-135.
    • (2005) J. Pharmacol. Toxicol. Methods , vol.52 , Issue.1 , pp. 123-135
    • Guo, L.1    Guthrie, H.2
  • 45
    • 0015396686 scopus 로고
    • A miniature microelectrode array to monitor the bioelectric activity of cultured cells
    • Thomas, C. A. Jr, Springer, P. A., Loeb, G. E., Berwald-Netter, Y., and Okun, L. M. A miniature microelectrode array to monitor the bioelectric activity of cultured cells. Exp. Cell Res. 1972, 74(1): 61-66.
    • (1972) Exp. Cell Res. , vol.74 , Issue.1 , pp. 61-66
    • Thomas Jr., C.A.1    Springer, P.A.2    Loeb, G.E.3    Berwald-Netter, Y.4    Okun, L.M.5
  • 46
    • 0017759085 scopus 로고
    • A new fixedarray multi-microelectrode system designed for long-term monitoring of extracellular single unit neuronal activity in vitro
    • Gross, G. W., Rieske, E., Kreutzberg, G. W. and Meyer, A. A new fixedarray multi-microelectrode system designed for long-term monitoring of extracellular single unit neuronal activity in vitro. Neurosci. Lett. 1977, 6(2-3): 101-105.
    • (1977) Neurosci. Lett. , vol.6 , Issue.2-3 , pp. 101-105
    • Gross, G.W.1    Rieske, E.2    Kreutzberg, G.W.3    Meyer, A.4
  • 47
    • 0035253614 scopus 로고    scopus 로고
    • Cell-transistor hybrid systems and their potential applications
    • Offenhausser, A. and Knoll, W. Cell-transistor hybrid systems and their potential applications. Trends Biotechnol. 2001, 19(2): 62-66.
    • (2001) Trends Biotechnol. , vol.19 , Issue.2 , pp. 62-66
    • Offenhausser, A.1    Knoll, W.2
  • 48
    • 0025138578 scopus 로고
    • An extracellular microelectrode array for monitoring electrogenic cells in culture
    • Connolly, P., Clark, P., Curtis, A. S., Dow, J. A., and Wilkinson, C. D. An extracellular microelectrode array for monitoring electrogenic cells in culture. Biosens. Bioelectron. 1990, 5(3): 223-234.
    • (1990) Biosens. Bioelectron. , vol.5 , Issue.3 , pp. 223-234
    • Connolly, P.1    Clark, P.2    Curtis, A.S.3    Dow, J.A.4    Wilkinson, C.D.5
  • 49
    • 1442355645 scopus 로고    scopus 로고
    • Neuron-semiconductor chip with chemical synapse between identified neurons
    • Kaul, R. A., Syed, N. I., and Fromherz, P. Neuron-semiconductor chip with chemical synapse between identified neurons. Phys. Rev. Lett. 2004, 92(3): 038102.
    • (2004) Phys. Rev. Lett. , vol.92 , Issue.3 , pp. 038102
    • Kaul, R.A.1    Syed, N.I.2    Fromherz, P.3
  • 51
    • 0026434555 scopus 로고
    • A neuron-silicon junction: a Retzius cell of the leech on an insulated-gate
    • Fromherz, P., Offenhausser, A., Vetter, T., and Weis, J. A neuron-silicon junction: a Retzius cell of the leech on an insulated-gate. Science 1991, 252(5010): 1290-1293.
    • (1991) Science , vol.252 , Issue.5010 , pp. 1290-1293
    • Fromherz, P.1    Offenhausser, A.2    Vetter, T.3    Weis, J.4
  • 54
    • 0018899387 scopus 로고
    • Recording action potentials from cultured neurons with extracellular microcircuit electrodes
    • Pine, J. Recording action potentials from cultured neurons with extracellular microcircuit electrodes. J. Neurosci. Methods 1980, 2(1): 19-31.
    • (1980) J. Neurosci. Methods , vol.2 , Issue.1 , pp. 19-31
    • Pine, J.1
  • 55
    • 0034663459 scopus 로고    scopus 로고
    • Multi-electrode stimulation and recording in the isolated retina
    • Grumet, A. E., Wyatt, J. L. Jr, and Rizzo, J. F. Multi-electrode stimulation and recording in the isolated retina. J. Neurosci. Methods 2000, 101(1): 31-42.
    • (2000) J. Neurosci. Methods , vol.101 , Issue.1 , pp. 31-42
    • Grumet, A.E.1    Wyatt Jr., J.L.2    Rizzo, J.F.3
  • 56
    • 84889323065 scopus 로고    scopus 로고
    • A functional cardiomyocyte based biosensor for prediagnostic monitoring: an angiotensin II study
    • Proceedings, IFMBE, Medical & Biological Engineering & Computing
    • Kurz, R., Rothermel, A., Rüffer, M., Urban, C., Jahnke, H.-G., Weigel, W., and Robitzki, A. A functional cardiomyocyte based biosensor for prediagnostic monitoring: an angiotensin II study. Proceedings, IFMBE, Medical & Biological Engineering & Computing, 2004, pp. 1727-1983.
    • (2004) , pp. 1727-1983
    • Kurz, R.1    Rothermel, A.2    Rüffer, M.3    Urban, C.4    Jahnke, H.-G.5    Weigel, W.6    Robitzki, A.7
  • 57
    • 10244235353 scopus 로고    scopus 로고
    • QT-screen: highthroughput cardiac safety pharmacology by extracellular electrophysiology on primary cardiac myocytes
    • Meyer, T., Leisgen, C., Gonser, B., and Gunther, E. QT-screen: highthroughput cardiac safety pharmacology by extracellular electrophysiology on primary cardiac myocytes. Assay Drug Dev. Technol. 2004, 2(5): 507-514.
    • (2004) Assay Drug Dev. Technol. , vol.2 , Issue.5 , pp. 507-514
    • Meyer, T.1    Leisgen, C.2    Gonser, B.3    Gunther, E.4
  • 58
    • 4544254897 scopus 로고    scopus 로고
    • Micro-electrode arrays in cardiac safety pharmacology: a novel tool to study QT interval prolon gation
    • Meyer, T., Boven, K. H., Gunther, E., and Fejtl, M. Micro-electrode arrays in cardiac safety pharmacology: a novel tool to study QT interval prolon gation. Drug Safety 2004, 27(11): 763-772.
    • (2004) Drug Safety , vol.27 , Issue.11 , pp. 763-772
    • Meyer, T.1    Boven, K.H.2    Gunther, E.3    Fejtl, M.4
  • 59
    • 0033929222 scopus 로고    scopus 로고
    • Quantification of acute neurotoxic effects of trimethyltin using neuronal networks cultured on microelectrode arrays
    • Gramowski, A., Schiffmann, D., and Gross, G. W. Quantification of acute neurotoxic effects of trimethyltin using neuronal networks cultured on microelectrode arrays. Neurotoxicology 2000, 21(3): 331-342.
    • (2000) Neurotoxicology , vol.21 , Issue.3 , pp. 331-342
    • Gramowski, A.1    Schiffmann, D.2    Gross, G.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.