메뉴 건너뛰기




Volumn 164, Issue 1, 2012, Pages 7-14

Geometrical considerations for the design of liquid-phase biochemical sensors using a cantilever's fundamental in-plane mode

Author keywords

Bio chemical sensors; Cantilevers; Liquid phase

Indexed keywords

BEAM GEOMETRY; BIO-CHEMICAL SENSOR; CANTILEVERS; DESIGN GUIDELINES; EXPERIMENTAL DATA; FLEXURAL MODES; GEOMETRICAL CONSIDERATIONS; LIMIT OF DETECTION; LIQUID PHASE; MASS LOADINGS; OUT-OF-PLANE; Q-FACTORS; QUALITY FACTORS; RESONANCE FREQUENCIES; SILICON CANTILEVER BEAM; SILICON LAYER;

EID: 84858080225     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.01.035     Document Type: Article
Times cited : (27)

References (28)
  • 1
    • 33847028640 scopus 로고    scopus 로고
    • Microsensor integration intro systems-on-chip
    • O. Brand Microsensor integration intro systems-on-chip Proceedings of IEEE 94 6 2006 1160 1176
    • (2006) Proceedings of IEEE , vol.94 , Issue.6 , pp. 1160-1176
    • Brand, O.1
  • 2
    • 33847214929 scopus 로고    scopus 로고
    • Liquid-phase chemical and biological detection using fully integrated magnetically actuated complementary metal oxide semiconductor resonant cantilever sensor systems
    • C. Vancura Liquid-phase chemical and biological detection using fully integrated magnetically actuated complementary metal oxide semiconductor resonant cantilever sensor systems Analytical Chemistry 79 4 2007 1646 1654
    • (2007) Analytical Chemistry , vol.79 , Issue.4 , pp. 1646-1654
    • Vancura, C.1
  • 4
    • 67649763918 scopus 로고    scopus 로고
    • Dimensional considerations in achieving large quality factors for resonant silicon cantilevers in air
    • K. Naeli, and O. Brand Dimensional considerations in achieving large quality factors for resonant silicon cantilevers in air Journal of Applied Physics 105 1 2009 014908
    • (2009) Journal of Applied Physics , vol.105 , Issue.1 , pp. 014908
    • Naeli, K.1    Brand, O.2
  • 5
    • 41149179264 scopus 로고    scopus 로고
    • Mechanical quality factor of cantilevers for mass sensing applications
    • 68001Y-1-668001Y07
    • J. Lu, et al., Mechanical quality factor of cantilevers for mass sensing applications, Proceedings of SPIE 6800 (2007) 68001Y-1-668001Y07.
    • (2007) Proceedings of SPIE 6800
    • Lu, J.1
  • 6
    • 61449208025 scopus 로고    scopus 로고
    • Multimode thermoelastic dissipation
    • S.A. Chandorkar Multimode thermoelastic dissipation Journal of Applied Physics 105 4 2009 043505
    • (2009) Journal of Applied Physics , vol.105 , Issue.4 , pp. 043505
    • Chandorkar, S.A.1
  • 7
    • 49549096471 scopus 로고    scopus 로고
    • Generalized model of resonant polymer-coated microcantilevers in viscous liquid medium
    • R. Cox Generalized model of resonant polymer-coated microcantilevers in viscous liquid medium Analytical Chemistry 80 15 2008 5760 5767
    • (2008) Analytical Chemistry , vol.80 , Issue.15 , pp. 5760-5767
    • Cox, R.1
  • 8
    • 33747828666 scopus 로고    scopus 로고
    • A microcantilever chemical sensors optimization by taking into account losses
    • DOI 10.1016/j.snb.2006.04.034, PII S0925400506003054
    • F. Lochon, I. Dufour, and D. Rebiere A microcantilever chemical sensors optimization by taking into account losses Sensors and Actuators B: Chemical 118 2006 292 296 (Pubitemid 44287416)
    • (2006) Sensors and Actuators, B: Chemical , vol.118 , Issue.1-2 , pp. 292-296
    • Lochon, F.1    Dufour, I.2    Rebiere, D.3
  • 9
    • 68349108114 scopus 로고    scopus 로고
    • Integrated MEMS/NEMS resonant cantilevers for ultrasensitive biological detection
    • X. Li Integrated MEMS/NEMS resonant cantilevers for ultrasensitive biological detection Journal of Sensors 2009
    • (2009) Journal of Sensors
    • Li, X.1
  • 10
    • 59949096897 scopus 로고    scopus 로고
    • Nanogram per milliliter-level immunologic detection of alpha-fetoprotein with integrated rotating-resonance microcantielvers for early-stage diagnosis of hepatocellular carcinoma
    • Y. Liu Nanogram per milliliter-level immunologic detection of alpha-fetoprotein with integrated rotating-resonance microcantielvers for early-stage diagnosis of hepatocellular carcinoma Biomedical Microdevices 11 2009 183 191
    • (2009) Biomedical Microdevices , vol.11 , pp. 183-191
    • Liu, Y.1
  • 11
    • 78649768792 scopus 로고    scopus 로고
    • Integration of microfluidic and cantilever technology for biosensing applications in liquid environment
    • C. Ricciardi Integration of microfluidic and cantilever technology for biosensing applications in liquid environment Biosensors & Bioelectronics 26 2010 1565 1570
    • (2010) Biosensors & Bioelectronics , vol.26 , pp. 1565-1570
    • Ricciardi, C.1
  • 12
    • 79953797757 scopus 로고    scopus 로고
    • MEMS biosensor for parallel and highly sensitive and specific detection of hepatitis
    • Cancun, Mexico
    • H. Urey MEMS biosensor for parallel and highly sensitive and specific detection of hepatitis 24th IEEE MEMS Conference Cancun, Mexico 2011 920 923
    • (2011) 24th IEEE MEMS Conference , pp. 920-923
    • Urey, H.1
  • 13
    • 47749083999 scopus 로고    scopus 로고
    • High Q-factor in-plane mode resonant microsensor platform for gaseous/liquid environment
    • J.H. Seo, and O. Brand High Q-factor in-plane mode resonant microsensor platform for gaseous/liquid environment Journal of Microelectromechanical Systems 17 2 2008 483 493
    • (2008) Journal of Microelectromechanical Systems , vol.17 , Issue.2 , pp. 483-493
    • Seo, J.H.1    Brand, O.2
  • 14
    • 79959667845 scopus 로고    scopus 로고
    • Resonant cantilever sensors operated in a high-Q in-plane mode for real-time bio/chemical detection in liquids
    • Y. Toa Resonant cantilever sensors operated in a high-Q in-plane mode for real-time bio/chemical detection in liquids Sensors and Actuators B: Chemical 157 2011 606 614
    • (2011) Sensors and Actuators B: Chemical , vol.157 , pp. 606-614
    • Toa, Y.1
  • 15
    • 63249094174 scopus 로고    scopus 로고
    • Resonant MEMS sensors for detection of aqueous heavy metal ions with sub-ppm resolution
    • Inst. of Elec. and Elec. Eng. Computer Society Hong Kong, China
    • A. Rahafrooz, and S. Pourkamali Resonant MEMS sensors for detection of aqueous heavy metal ions with sub-ppm resolution 2008 IEEE International Conference on Electron Devices and Solid-State Circuits 2008 Inst. of Elec. and Elec. Eng. Computer Society Hong Kong, China 1 4
    • (2008) 2008 IEEE International Conference on Electron Devices and Solid-State Circuits , pp. 1-4
    • Rahafrooz, A.1    Pourkamali, S.2
  • 16
    • 79951919006 scopus 로고    scopus 로고
    • Rotational mode disk resonators for high-Q operation in liquid
    • Waikoloa, Hawaii
    • A. Rahafrooz, and S. Pourkamali Rotational mode disk resonators for high-Q operation in liquid IEEE Sensors Conference Waikoloa, Hawaii 2010 1071 1074
    • (2010) IEEE Sensors Conference , pp. 1071-1074
    • Rahafrooz, A.1    Pourkamali, S.2
  • 17
    • 33749347435 scopus 로고    scopus 로고
    • Ethanol vapor detection in saline solution using piezoresistive microcantilevers
    • C.P. Cheney Ethanol vapor detection in saline solution using piezoresistive microcantilevers Review of Scientific Instruments 77 9 2006 95101 95111
    • (2006) Review of Scientific Instruments , vol.77 , Issue.9 , pp. 95101-95111
    • Cheney, C.P.1
  • 18
    • 34247612361 scopus 로고    scopus 로고
    • Weighing of biomolecules, single cells and nanoparticles in fluid
    • T.P. Burg Weighing of biomolecules, single cells and nanoparticles in fluid Nature 446 7139 2007 11066 11069
    • (2007) Nature , vol.446 , Issue.7139 , pp. 11066-11069
    • Burg, T.P.1
  • 19
    • 79551651135 scopus 로고    scopus 로고
    • Suspended microchannel resonators with piezoresistive sensors
    • J. Lee Suspended microchannel resonators with piezoresistive sensors Lab on a Chip 11 2011 645 651
    • (2011) Lab on A Chip , vol.11 , pp. 645-651
    • Lee, J.1
  • 20
    • 79953784071 scopus 로고    scopus 로고
    • Suspended nanochannel in MEMS plate resonator for mass sensing in liquid
    • Cancun, Mexico
    • V. Agache Suspended nanochannel in MEMS plate resonator for mass sensing in liquid 24th IEEE MEMS Conference Cancun, Mexico 2011 157 160
    • (2011) 24th IEEE MEMS Conference , pp. 157-160
    • Agache, V.1
  • 21
    • 79953789760 scopus 로고    scopus 로고
    • Novel type of microcantilever biosensor resonating at the interface between liquid and air
    • Cancun, Mexico
    • J. Park Novel type of microcantilever biosensor resonating at the interface between liquid and air 24th IEEE MEMS Conference Cancun, Mexico 2011 948 951
    • (2011) 24th IEEE MEMS Conference , pp. 948-951
    • Park, J.1
  • 22
    • 0036646553 scopus 로고    scopus 로고
    • Complementary metal oxide semiconductor cantilever arrays on a single chip: Mass-sensitive detection of volatile organic compounds
    • DOI 10.1021/ac011269j
    • D. Lange Complementary metal oxide semiconductor cantilever arrays on a single chip: mass-sensitive detection of volatile organic compounds Analytical Chemistry 74 13 2002 3084 3095 (Pubitemid 34755221)
    • (2002) Analytical Chemistry , vol.74 , Issue.13 , pp. 3084-3095
    • Lange, D.1    Hagleitner, C.2    Hierlemann, A.3    Brand, O.4    Baltes, H.5
  • 23
    • 77955425361 scopus 로고    scopus 로고
    • Thermal excitation and piezoresistive detection of cantilever in-plane resonance modes for sensing applications
    • L.A. Beardslee Thermal excitation and piezoresistive detection of cantilever in-plane resonance modes for sensing applications Journal of Microelectromechanical Systems 19 4 2010 1015 1017
    • (2010) Journal of Microelectromechanical Systems , vol.19 , Issue.4 , pp. 1015-1017
    • Beardslee, L.A.1
  • 25
    • 79951920868 scopus 로고    scopus 로고
    • An analytical model of a thermally excited microcantilever vibrating laterally in a viscous fluid
    • Waikoloa, Hawaii
    • S.M. Heinrich An analytical model of a thermally excited microcantilever vibrating laterally in a viscous fluid Proceedings of the IEEE Sensors Conference Waikoloa, Hawaii 2010
    • (2010) Proceedings of the IEEE Sensors Conference
    • Heinrich, S.M.1
  • 26
    • 79951906984 scopus 로고    scopus 로고
    • An analytical model for in-plane flexural vibrations of thin cantilever-based sensors in viscous fluids: Applications to chemical sensing in liquids
    • Banff, Canada
    • S.M. Heinrich An analytical model for in-plane flexural vibrations of thin cantilever-based sensors in viscous fluids: applications to chemical sensing in liquids International Workshop on Nanomechanical Cantilever Sensors Banff, Canada 2010 2 pp.
    • (2010) International Workshop on Nanomechanical Cantilever Sensors , pp. 2
    • Heinrich, S.M.1
  • 27
    • 80052130752 scopus 로고    scopus 로고
    • On the relative sensitivity of mass-sensitive chemical microsensors
    • Beijing, China
    • L.A. Beardslee, et al., On the relative sensitivity of mass-sensitive chemical microsensors, in: Transducers 2011, Beijing, China, pp. 1112-1115.
    • (2011) Transducers , pp. 1112-1115
    • Beardslee, L.A.1
  • 28
    • 0001987653 scopus 로고
    • A modified allan variance with increased oscillator characterization ability
    • Philadelphia
    • D.W. Allan, and J.A. Barnes A modified allan variance with increased oscillator characterization ability 35th Annual Frequency Control Symposium Philadelphia 1981 470 475
    • (1981) 35th Annual Frequency Control Symposium , pp. 470-475
    • Allan, D.W.1    Barnes, J.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.