Volumn 39, Issue 3, 2012, Pages 1289-1297

Breast composition measurement with a cadmium-zinc-telluride based spectral computed tomography system

Author keywords

breast imaging; CT; material decomposition; photon counting detector

Indexed keywords

ACETAL RESINS; CADMIUM COMPOUNDS; CADMIUM TELLURIDE; CHEMICAL ANALYSIS; II-VI SEMICONDUCTORS; MAMMALS; MEDICAL IMAGING; PHOTONS; PROTEINS; SIGNAL TO NOISE RATIO; TISSUE; Z TRANSFORMS; ZINC COMPOUNDS;

EID: 84857883071     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3681273     Document Type: Article
Times cited : (31)

References (55)
  • 1
    • 77749292346 scopus 로고    scopus 로고
    • Radiation dose reduction using a CdZnTe-based computed tomography system: Comparison to flat-panel detectors
    • 10.1118/1.3312435
    • H. Q. Le, J. L. Ducote, and S. Molloi, Radiation dose reduction using a CdZnTe-based computed tomography system: Comparison to flat-panel detectors., Med. Phys. 37, 1225-1236 (2010). 10.1118/1.3312435
    • (2010) Med. Phys. , vol.37 , pp. 1225-1236
    • Le, H.Q.1    Ducote, J.L.2    Molloi, S.3
  • 2
    • 42649114425 scopus 로고    scopus 로고
    • Computed tomography with energy-resolved detection: A feasibility study
    • 10.1088/0031-9155/53/5/020
    • P. M. Shikhaliev, Computed tomography with energy-resolved detection: A feasibility study., Phys. Med. Biol. 53, 1475-1495 (2008). 10.1088/0031-9155/53/ 5/020
    • (2008) Phys. Med. Biol. , vol.53 , pp. 1475-1495
    • Shikhaliev, P.M.1
  • 3
    • 33747603940 scopus 로고    scopus 로고
    • Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging
    • 10.1088/0031-9155/51/17/010
    • P. M. Shikhaliev, Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging., Phys. Med. Biol. 51, 4267-4287 (2006). 10.1088/0031-9155/51/17/010
    • (2006) Phys. Med. Biol. , vol.51 , pp. 4267-4287
    • Shikhaliev, P.M.1
  • 4
    • 0033461146 scopus 로고    scopus 로고
    • Detective quantum efficiency dependence on x-ray energy weighting in mammography
    • 10.1118/1.598807
    • R. N. Cahn, B. Cederstrom, M. Danielsson, A. Hall, M. Lundqvist, and D. Nygren, Detective quantum efficiency dependence on x-ray energy weighting in mammography., Med. Phys. 26, 2680-2683 (1999). 10.1118/1.598807
    • (1999) Med. Phys. , vol.26 , pp. 2680-2683
    • Cahn, R.N.1    Cederstrom, B.2    Danielsson, M.3    Hall, A.4    Lundqvist, M.5    Nygren, D.6
  • 5
    • 4544325396 scopus 로고    scopus 로고
    • The influence of energy weighting on x-ray imaging quality
    • 10.1016/j.nima.2004.05.076
    • J. Giersch, D. Niederlohner, and G. Anton, The influence of energy weighting on x-ray imaging quality., Nucl. Instrum. Methods Phys. Res. A 531, 68-74 (2004). 10.1016/j.nima.2004.05.076
    • (2004) Nucl. Instrum. Methods Phys. Res. A , vol.531 , pp. 68-74
    • Giersch, J.1    Niederlohner, D.2    Anton, G.3
  • 6
    • 20444492877 scopus 로고    scopus 로고
    • The energy weighting technique: Measurements and simulations
    • 10.1016/j.nima.2005.03.037
    • D. Niederlohner, J. Karg, J. Giersch, and G. Anton, The energy weighting technique: Measurements and simulations., Nucl. Instrum. Methods Phys. Res. A 546, 37-41 (2005). 10.1016/j.nima.2005.03.037
    • (2005) Nucl. Instrum. Methods Phys. Res. A , vol.546 , pp. 37-41
    • Niederlohner, D.1    Karg, J.2    Giersch, J.3    Anton, G.4
  • 8
    • 0021812629 scopus 로고
    • SNR and DQE analysis of broad-spectrum x-ray-imaging
    • 10.1088/0031-9155/30/6/002
    • M. J. Tapiovaara and R. F. Wagner, SNR and DQE analysis of broad-spectrum x-ray-imaging., Phys. Med. Biol. 30, 519-529 (1985). 10.1088/0031-9155/30/6/002
    • (1985) Phys. Med. Biol. , vol.30 , pp. 519-529
    • Tapiovaara, M.J.1    Wagner, R.F.2
  • 10
    • 67650101681 scopus 로고    scopus 로고
    • Comparison of single-photon counting and charge-integrating detectors for x-ray high-resolution imaging of small biological objects
    • 10.1016/j.nima.2009.03.158
    • P. M. Frallicciardi, J. Jakubek, D. Vavrik, and J. Dammer, Comparison of single-photon counting and charge-integrating detectors for x-ray high-resolution imaging of small biological objects., Nucl. Instrum. Methods Phys. Res. A 607, 221-222 (2009). 10.1016/j.nima.2009.03.158
    • (2009) Nucl. Instrum. Methods Phys. Res. A , vol.607 , pp. 221-222
    • Frallicciardi, P.M.1    Jakubek, J.2    Vavrik, D.3    Dammer, J.4
  • 12
    • 0037679314 scopus 로고    scopus 로고
    • Planar image quality comparison between a CdZnTe prototype and a standard NaI(T1) gamma camera
    • 10.1016/S0168-9002(03)01153-7
    • D. J. Wagenaar, S. Chowdhury, J. C. Engdahl, and D. D. Burckhardt, Planar image quality comparison between a CdZnTe prototype and a standard NaI(T1) gamma camera., Nucl. Instrum. Methods Phys. Res. A 505, 586-589 (2003). 10.1016/S0168-9002(03)01153-7
    • (2003) Nucl. Instrum. Methods Phys. Res. A , vol.505 , pp. 586-589
    • Wagenaar, D.J.1    Chowdhury, S.2    Engdahl, J.C.3    Burckhardt, D.D.4
  • 13
    • 79952172950 scopus 로고    scopus 로고
    • Material separation in x-ray CT with energy resolved photon-counting detectors
    • 10.1118/1.3553401
    • X. L. Wang, D. Meier, K. Taguchi, D. J. Wagenaar, B. E. Patt, and E. C. Frey, Material separation in x-ray CT with energy resolved photon-counting detectors., Med. Phys. 38, 1534-1546 (2011). 10.1118/1.3553401
    • (2011) Med. Phys. , vol.38 , pp. 1534-1546
    • Wang, X.L.1    Meier, D.2    Taguchi, K.3    Wagenaar, D.J.4    Patt, B.E.5    Frey, E.C.6
  • 15
    • 79959375109 scopus 로고    scopus 로고
    • Fast photon counting CdTe detectors for diagnostic clinical CT: Dynamic range, stability, and temporal response
    • E. 10.1117/12.844669
    • W. C. Barber, E. Nygard, J. C. Wessel, N. Malakhov, G. Wawrzyniak, N. E. Hartsough, T. Gandhi, and J. S. Iwanczyk, Fast photon counting CdTe detectors for diagnostic clinical CT: Dynamic range, stability, and temporal response., Proc. SPIE 7622, 76221 E (2010). 10.1117/12.844669
    • (2010) Proc. SPIE , vol.7622 , pp. 76221
    • Barber, W.C.1    Nygard, E.2    Wessel, J.C.3    Malakhov, N.4    Wawrzyniak, G.5    Hartsough, N.E.6    Gandhi, T.7    Iwanczyk, J.S.8
  • 19
    • 34547137886 scopus 로고    scopus 로고
    • K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
    • 10.1088/0031-9155/52/15/020
    • E. Roessl and R. Proksa, K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors., Phys. Med. Biol. 52, 4679-4696 (2007). 10.1088/0031-9155/52/15/020
    • (2007) Phys. Med. Biol. , vol.52 , pp. 4679-4696
    • Roessl, E.1    Proksa, R.2
  • 22
    • 0035428563 scopus 로고    scopus 로고
    • Recent progress in CdTe and CdZnTe detectors
    • 10.1109/23.958705
    • T. Takahashi and S. Watanabe, Recent progress in CdTe and CdZnTe detectors., IEEE Trans. Nucl. Sci. 48, 950-959 (2001). 10.1109/23.958705
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 950-959
    • Takahashi, T.1    Watanabe, S.2
  • 23
    • 79953012389 scopus 로고    scopus 로고
    • Photon counting spectral CT versus conventional CT: Comparative evaluation for breast imaging application
    • 10.1088/0031-9155/56/7/001
    • P. M. Shikhaliev and S. G. Fritz, Photon counting spectral CT versus conventional CT: Comparative evaluation for breast imaging application., Phys. Med. Biol. 56, 1905-1930 (2011). 10.1088/0031-9155/56/7/001
    • (2011) Phys. Med. Biol. , vol.56 , pp. 1905-1930
    • Shikhaliev, P.M.1    Fritz, S.G.2
  • 24
    • 58149231346 scopus 로고    scopus 로고
    • Energy-resolved computed tomography: First experimental results
    • 10.1088/0031-9155/53/20/002
    • P. M. Shikhaliev, Energy-resolved computed tomography: First experimental results., Phys. Med. Biol. 53, 5595-5613 (2008). 10.1088/0031-9155/53/20/002
    • (2008) Phys. Med. Biol. , vol.53 , pp. 5595-5613
    • Shikhaliev, P.M.1
  • 25
    • 84857872679 scopus 로고    scopus 로고
    • Breast CT with energy resolved detection
    • 10.1118/1.2761582
    • P. M. Shikhaliev, Breast CT with energy resolved detection., Med. Phys. 34, 2607-2607 (2007). 10.1118/1.2761582
    • (2007) Med. Phys. , vol.34 , pp. 2607-2607
    • Shikhaliev, P.M.1
  • 26
    • 78650913156 scopus 로고    scopus 로고
    • Segmentation and quantification of materials with energy discriminating computed tomography: A phantom study
    • 10.1118/1.3525835
    • H. Q. Le and S. Molloi, Segmentation and quantification of materials with energy discriminating computed tomography: A phantom study., Med. Phys. 38, 228-237 (2011). 10.1118/1.3525835
    • (2011) Med. Phys. , vol.38 , pp. 228-237
    • Le, H.Q.1    Molloi, S.2
  • 27
    • 78650895895 scopus 로고    scopus 로고
    • Least squares parameter estimation methods for material decomposition with energy discriminating detectors
    • 10.1118/1.3525840
    • H. Q. Le and S. Molloi, Least squares parameter estimation methods for material decomposition with energy discriminating detectors., Med. Phys. 38, 245-255 (2011). 10.1118/1.3525840
    • (2011) Med. Phys. , vol.38 , pp. 245-255
    • Le, H.Q.1    Molloi, S.2
  • 28
    • 34447303835 scopus 로고    scopus 로고
    • Physical characterization of a scanning photon counting digital mammography system based on Si-strip detectors
    • 10.1118/1.2731032
    • M. Aslund, B. Cederstrom, M. Lundqvist, and M. Danielsson, Physical characterization of a scanning photon counting digital mammography system based on Si-strip detectors., Med. Phys. 34, 1918-1925 (2007). 10.1118/1.2731032
    • (2007) Med. Phys. , vol.34 , pp. 1918-1925
    • Aslund, M.1    Cederstrom, B.2    Lundqvist, M.3    Danielsson, M.4
  • 29
    • 33847645786 scopus 로고    scopus 로고
    • A comparison of the performance of digital mammography systems
    • 10.1118/1.2432072
    • P. Monnin, D. Gutierrez, S. Bulling, D. Guntern, and F. R. Verdun, A comparison of the performance of digital mammography systems., Med. Phys. 34, 906-914 (2007). 10.1118/1.2432072
    • (2007) Med. Phys. , vol.34 , pp. 906-914
    • Monnin, P.1    Gutierrez, D.2    Bulling, S.3    Guntern, D.4    Verdun, F.R.5
  • 30
    • 77949704874 scopus 로고    scopus 로고
    • Photon-counting spectral computed tomography using silicon strip detectors: A feasibility study
    • 10.1088/0031-9155/55/7/014
    • H. Bornefalk and M. Danielsson, Photon-counting spectral computed tomography using silicon strip detectors: A feasibility study., Phys. Med. Biol. 55, 1999-2022 (2010). 10.1088/0031-9155/55/7/014
    • (2010) Phys. Med. Biol. , vol.55 , pp. 1999-2022
    • Bornefalk, H.1    Danielsson, M.2
  • 31
    • 67649610804 scopus 로고    scopus 로고
    • Optimal image-based' weighting for energy-resolved CT
    • 10.1118/1.3148535
    • T. G. Schmidt, Optimal image-based' weighting for energy-resolved CT., Med. Phys. 36, 3018-3027 (2009). 10.1118/1.3148535
    • (2009) Med. Phys. , vol.36 , pp. 3018-3027
    • Schmidt, T.G.1
  • 32
    • 78650045358 scopus 로고    scopus 로고
    • Performance simulation of an x-ray detector for spectral CT with combined Si and CdZnTe detection layers
    • 10.1088/0031-9155/55/24/020
    • C. Herrmann, K. J. Engel, and J. Wiegert, Performance simulation of an x-ray detector for spectral CT with combined Si and CdZnTe detection layers., Phys. Med. Biol. 55, 7697-7713 (2010). 10.1088/0031-9155/55/24/020
    • (2010) Phys. Med. Biol. , vol.55 , pp. 7697-7713
    • Herrmann, C.1    Engel, K.J.2    Wiegert, J.3
  • 33
    • 78149475974 scopus 로고    scopus 로고
    • An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors
    • 10.1118/1.3429056
    • K. Taguchi, E. C. Frey, X. L. Wang, J. S. Iwanczyk, and W. C. Barber, An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors., Med. Phys. 37, 3957-3969 (2010). 10.1118/1.3429056
    • (2010) Med. Phys. , vol.37 , pp. 3957-3969
    • Taguchi, K.1    Frey, E.C.2    Wang, X.L.3    Iwanczyk, J.S.4    Barber, W.C.5
  • 36
    • 73649133981 scopus 로고    scopus 로고
    • Compositional breast imaging using a dual-energy mammography protocol
    • 10.1118/1.3259715
    • A. D. Laidevant, S. Malkov, C. I. Flowers, K. Kerlikowske, and J. A. Shepherd, Compositional breast imaging using a dual-energy mammography protocol., Med. Phys. 37, 164-174 (2010). 10.1118/1.3259715
    • (2010) Med. Phys. , vol.37 , pp. 164-174
    • Laidevant, A.D.1    Malkov, S.2    Flowers, C.I.3    Kerlikowske, K.4    Shepherd, J.A.5
  • 37
    • 79952354871 scopus 로고    scopus 로고
    • The mammographic density of a mass is a significant predictor of breast cancer
    • 10.1148/radiol.10100328
    • E. S. Burnside, R. W. Woods, G. S. Sisney, L. R. Salkowski, K. Shinki, and Y. Z. Lin, The mammographic density of a mass is a significant predictor of breast cancer., Radiology 258, 417-425 (2011). 10.1148/radiol.10100328
    • (2011) Radiology , vol.258 , pp. 417-425
    • Burnside, E.S.1    Woods, R.W.2    Sisney, G.S.3    Salkowski, L.R.4    Shinki, K.5    Lin, Y.Z.6
  • 38
    • 29244439606 scopus 로고    scopus 로고
    • Imaging in breast cancer-Diffuse optics in breast cancer: Detecting tumors in pre-menopausal women and monitoring neoadjuvant chemotherapy
    • 10.1186/bcr1358
    • B. J. Tromberg, A. Cerussi, N. Shah, M. Compton, A. Durkin, D. Hsiang, J. Butler, and R. Mehta, Imaging in breast cancer-Diffuse optics in breast cancer: Detecting tumors in pre-menopausal women and monitoring neoadjuvant chemotherapy., Breast Cancer Res. 7, 279-285 (2005). 10.1186/bcr1358
    • (2005) Breast Cancer Res. , vol.7 , pp. 279-285
    • Tromberg, B.J.1    Cerussi, A.2    Shah, N.3    Compton, M.4    Durkin, A.5    Hsiang, D.6    Butler, J.7    Mehta, R.8
  • 40
    • 33751312072 scopus 로고    scopus 로고
    • In vivo absorption, scattering, and physiologic properties of 58 malignant breast tumors determined by broadband diffuse optical spectroscopy
    • 10.1117/1.2337546
    • A. Cerussi, N. Shah, D. Hsiang, A. Durkin, J. Butler, and B. J. Tromberg, In vivo absorption, scattering, and physiologic properties of 58 malignant breast tumors determined by broadband diffuse optical spectroscopy., J. Biomed. Opt. 11, 004405 (2006). 10.1117/1.2337546
    • (2006) J. Biomed. Opt. , vol.11 , pp. 004405
    • Cerussi, A.1    Shah, N.2    Hsiang, D.3    Durkin, A.4    Butler, J.5    Tromberg, B.J.6
  • 41
    • 33750684658 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging and its application to cancer
    • Edwards and, 10.1102/1470-7330.2006.0021
    • E. M. Charles -Edwards and N. M. deSouza, Diffusion-weighted magnetic resonance imaging and its application to cancer., Cancer Imaging 6, 135-143 (2006). 10.1102/1470-7330.2006.0021
    • (2006) Cancer Imaging , vol.6 , pp. 135-143
    • Charles, E.M.1    Desouza, N.M.2
  • 42
    • 0036703710 scopus 로고    scopus 로고
    • A dual-energy subtraction technique for microcalcification imaging in digital mammography-A signal-to-noise analysis
    • 10.1118/1.1494832
    • M. R. Lemacks, S. C. Kappadath, C. C. Shaw, X. M. Liu, and G. J. Whitman, A dual-energy subtraction technique for microcalcification imaging in digital mammography-A signal-to-noise analysis., Med. Phys. 29, 1739-1751 (2002). 10.1118/1.1494832
    • (2002) Med. Phys. , vol.29 , pp. 1739-1751
    • Lemacks, M.R.1    Kappadath, S.C.2    Shaw, C.C.3    Liu, X.M.4    Whitman, G.J.5
  • 43
    • 56749163915 scopus 로고    scopus 로고
    • Quantification of breast density with dual energy mammography: A simulation study
    • 10.1118/1.3002308
    • J. L. Ducote and S. Molloi, Quantification of breast density with dual energy mammography: A simulation study., Med. Phys. 35, 5411-5418 (2008). 10.1118/1.3002308
    • (2008) Med. Phys. , vol.35 , pp. 5411-5418
    • Ducote, J.L.1    Molloi, S.2
  • 44
    • 79952954576 scopus 로고    scopus 로고
    • Imaging of nanoparticles with dual-energy computed tomography
    • 10.1088/0031-9155/56/7/008
    • J. L. Ducote, Y. Alivov, and S. Molloi, Imaging of nanoparticles with dual-energy computed tomography., Phys. Med. Biol. 56, 2031-2044 (2011). 10.1088/0031-9155/56/7/008
    • (2011) Phys. Med. Biol. , vol.56 , pp. 2031-2044
    • Ducote, J.L.1    Alivov, Y.2    Molloi, S.3
  • 45
    • 0030657556 scopus 로고    scopus 로고
    • Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV
    • 10.1118/1.597953
    • J. M. Boone and J. A. Seibert, Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV., Med. Phys. 24, 1661-1670 (1997). 10.1118/1.597953
    • (1997) Med. Phys. , vol.24 , pp. 1661-1670
    • Boone, J.M.1    Seibert, J.A.2
  • 46
    • 33645000127 scopus 로고    scopus 로고
    • Technique factors and their relationship to radiation dose in pendant geometry breast CT
    • 10.1118/1.2128126
    • J. M. Boone, A. L. C. Kwan, J. A. Seibert, N. Shah, K. K. Lindfors, and T. R. Nelson, Technique factors and their relationship to radiation dose in pendant geometry breast CT., Med. Phys. 32, 3767-3776 (2005). 10.1118/1.2128126
    • (2005) Med. Phys. , vol.32 , pp. 3767-3776
    • Boone, J.M.1    Kwan, A.L.C.2    Seibert, J.A.3    Shah, N.4    Lindfors, K.K.5    Nelson, T.R.6
  • 47
    • 0022912646 scopus 로고
    • The composition of body-tissues
    • 10.1259/0007-1285-59-708-1209
    • H. Q. Woodard and D. R. White, The composition of body-tissues., Br. J. Radiol. 59, 1209-1219 (1986). 10.1259/0007-1285-59-708-1209
    • (1986) Br. J. Radiol. , vol.59 , pp. 1209-1219
    • Woodard, H.Q.1    White, D.R.2
  • 48
    • 0035999415 scopus 로고    scopus 로고
    • Normalized glandular dose (DgN) coefficients for arbitrary x-ray spectra in mammography: Computer-fit values of Monte Carlo derived data
    • 10.1118/1.1472499
    • J. M. Boone, Normalized glandular dose (DgN) coefficients for arbitrary x-ray spectra in mammography: Computer-fit values of Monte Carlo derived data., Med. Phys. 29, 869-875 (2002). 10.1118/1.1472499
    • (2002) Med. Phys. , vol.29 , pp. 869-875
    • Boone, J.M.1
  • 49
    • 75749097390 scopus 로고    scopus 로고
    • ImageJ, a useful tool for biological image processing and analysis
    • 10.1017/S1431927607076611
    • J. B. Sheffield, ImageJ, a useful tool for biological image processing and analysis., Microsc. Microanal. 13, 200-201 (2007). 10.1017/S1431927607076611
    • (2007) Microsc. Microanal. , vol.13 , pp. 200-201
    • Sheffield, J.B.1
  • 50
    • 84857869010 scopus 로고    scopus 로고
    • edited by U. S. D. o. Agriculture (Food Safety and Inspection Service, Office of Public Health Science, Washington,DC)
    • Determination of Fat CLG-FAT, edited by U. S. D. o. Agriculture (Food Safety and Inspection Service, Office of Public Health Science, Washington,DC, 2009), Vol. 03, pp. 1-8.
    • (2009) Determination of Fat CLG-FAT , vol.3 , pp. 1-8
  • 51
    • 79952354871 scopus 로고    scopus 로고
    • The mammographic density of a mass is a significant predictor of breast cancer
    • 10.1148/radiol.10100328
    • R. W. Woods, G. S. Sisney, L. R. Salkowski, K. Shinki, Y. Lin, and E. S. Burnside, The mammographic density of a mass is a significant predictor of breast cancer., Radiology 258, 417-425 (2011). 10.1148/radiol.10100328
    • (2011) Radiology , vol.258 , pp. 417-425
    • Woods, R.W.1    Sisney, G.S.2    Salkowski, L.R.3    Shinki, K.4    Lin, Y.5    Burnside, E.S.6
  • 52
    • 79961062129 scopus 로고    scopus 로고
    • Volumetric lean percentage measurement using dual energy mammography
    • 10.1118/1.3605632
    • J. L. Ducote, M. J. Klopfer, and S. Molloi, Volumetric lean percentage measurement using dual energy mammography., Med. Phys. 38, 4498-4504 (2011). 10.1118/1.3605632
    • (2011) Med. Phys. , vol.38 , pp. 4498-4504
    • Ducote, J.L.1    Klopfer, M.J.2    Molloi, S.3
  • 53
    • 70350725909 scopus 로고    scopus 로고
    • Photon counting multienergy x-ray imaging: Effect of the characteristic x rays on detector performance
    • 10.1118/1.3245875
    • P. M. Shikhaliev, S. G. Fritz, and J. W. Chapman, Photon counting multienergy x-ray imaging: Effect of the characteristic x rays on detector performance., Med. Phys. 36, 5107-5119 (2009). 10.1118/1.3245875
    • (2009) Med. Phys. , vol.36 , pp. 5107-5119
    • Shikhaliev, P.M.1    Fritz, S.G.2    Chapman, J.W.3
  • 55
    • 1242316319 scopus 로고    scopus 로고
    • A comprehensive analysis of DgN(CT) coefficients for pendant-geometry cone-beam breast computed tomography
    • 10.1118/1.1636571
    • J. M. Boone, N. Shah, and T. R. Nelson, A comprehensive analysis of DgN(CT) coefficients for pendant-geometry cone-beam breast computed tomography., Med. Phys. 31, 226-235 (2004). 10.1118/1.1636571
    • (2004) Med. Phys. , vol.31 , pp. 226-235
    • Boone, J.M.1    Shah, N.2    Nelson, T.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.