메뉴 건너뛰기




Volumn 7622, Issue PART 1, 2010, Pages

Fast photon counting CdTe detectors for diagnostic clinical CT: Dynamic range, stability, and temporal response

Author keywords

ASIC; CdTe; CT; Photon counting

Indexed keywords

CDTE; CDTE DETECTOR; CLINICAL CT; COUNTING STATISTICS; CT; DETECTOR PARAMETERS; DIAGNOSTIC CT; DIRECT CONVERSION; DYNAMIC RANGE; ENERGY RESOLUTIONS; INPUT FLUX; LONG EXPOSURES; LOW FLUX; LOW-DOSE CT; MAXIMUM OUTPUT; MULTISLICE CT; NOISE FLOOR; PHOTON COUNTING; RAPID CYCLING; SCAN TIME; SECOND GENERATION; TEMPORAL RESPONSE; TIME INTERVAL; UNIFORM FLUX; WHOLE-BODY; X-RAY DETECTOR;

EID: 79959375109     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.844669     Document Type: Conference Paper
Times cited : (17)

References (19)
  • 1
    • 85037530711 scopus 로고    scopus 로고
    • Photon-counting detectors for digital radiography and x-ray computed tomography
    • P.C. Johns, J. Dubeau, D.G. Gobbi, M.Li, and S. Dixit, Photon-Counting Detectors for Digital Radiography and X-Ray Computed Tomography, SPIE, TD01, 367-369, (2002).
    • (2002) SPIE, TD01 , pp. 367-369
    • Johns, P.C.1    Dubeau, J.2    Gobbi, D.G.3    Li, M.4    Dixit, S.5
  • 2
    • 14644437677 scopus 로고    scopus 로고
    • Photon computed tomography: Concept and initial results
    • P.M. Shikhaliev, X. Tong, S. Molloi, Photon computed tomography: Concept and initial results, Med. Phys., 32(2), 427-436, (2005).
    • (2005) Med. Phys. , vol.32 , Issue.2 , pp. 427-436
    • Shikhaliev, P.M.1    Tong, X.2    Molloi, S.3
  • 4
    • 0021812629 scopus 로고
    • SNR and DQE analysis of broad spectrum X-ray imaging
    • Tapiovaara MJ, Wagner R., SNR and DQE analysis of broad spectrum X-ray imaging. Physics in Medicine and Biology. 30(6):519-29, (1985).
    • (1985) Physics in Medicine and Biology , vol.30 , Issue.6 , pp. 519-529
    • Tapiovaara, M.J.1    Wagner, R.2
  • 5
    • 29144515780 scopus 로고    scopus 로고
    • Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: A simulation study
    • Shikhaliev PM., Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation study., Physics in Medicine and Biology. 50(24):5813-27, (2005).
    • (2005) Physics in Medicine and Biology. , vol.50 , Issue.24 , pp. 5813-5827
    • Shikhaliev, P.M.1
  • 6
    • 0030265054 scopus 로고    scopus 로고
    • New gamma-ray detector structures for electron only charge carrier collection utilizing high-Z compound semiconductors
    • B.E. Patt, J.S. Iwanczyk, G. Vilkelis, Y.J. Wang, New Gamma-ray Detector Structures for Electron Only Charge Carrier Collection Utilizing High-Z Compound Semiconductors, Nucl. Instr. & Meth. in Phys. Res,. A380, 276-281 (1996).
    • (1996) Nucl. Instr. & Meth. in Phys. Res,. , vol.A380 , pp. 276-281
    • Patt, B.E.1    Iwanczyk, J.S.2    Vilkelis, G.3    Wang, Y.J.4
  • 8
    • 0033461146 scopus 로고    scopus 로고
    • Detective quantum efficiency dependence on x-ray energy weighting in mammography
    • R. N. Cahn, B. Cederstrom, M. Danielsson, A. Hall, M. Lundqvist, and D. Nygren, Detective quantum efficiency dependence on x-ray energy weighting in mammography, Med. Phys., 26, 2680-2683, (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2680-2683
    • Cahn, R.N.1    Cederstrom, B.2    Danielsson, M.3    Hall, A.4    Lundqvist, M.5    Nygren, D.6
  • 9
    • 84905114239 scopus 로고    scopus 로고
    • First experimental tests with a CdTe photon counting pixel detector hybridized with a medipixl readout chip
    • M. Chmcissani, C. Frojdh, First Experimental Tests with a CdTe Photon Counting Pixel Detector Hybridized with a Medipixl Readout Chip, IEEE Trans. Nucl. Sci., 51(5), 2379-2385, (2004).
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.5 , pp. 2379-2385
    • Chmcissani, M.1    Frojdh, C.2
  • 10
    • 18644378201 scopus 로고    scopus 로고
    • A digital system based on a bi-chromatic X ray source and a single photon counting device: A single exposure dual energy mammography approach
    • M. Bisogni, M. Gambaccini, A digital system based on a bi-chromatic X ray source and a single photon counting device: a single exposure dual energy mammography approach, Proc. SPIE, 4682, 620-632, (2002).
    • (2002) Proc. SPIE , vol.4682 , pp. 620-632
    • Bisogni, M.1    Gambaccini, M.2
  • 11
    • 0042889399 scopus 로고    scopus 로고
    • X-ray imaging using single photon processing with semiconductor pixel detectors
    • B. Mikulec, M. Campbell, E. Heijne, X. Llopart, and L. Tlustos, X-ray Imaging Using Single Photon Processing with Semiconductor Pixel Detectors. NIM, A 511, 282-286, (2003).
    • (2003) NIM, A , vol.511 , pp. 282-286
    • Mikulec, B.1    Campbell, M.2    Heijne, E.3    Llopart, X.4    Tlustos, L.5
  • 16
    • 44649194989 scopus 로고    scopus 로고
    • CERN DxCTA counting mode chip
    • D. Moraes, J. Kaplon, E. Nygard, CERN DxCTA counting mode chip. NIM A 591, 167-170, (2008).
    • (2008) NIM A , vol.591 , pp. 167-170
    • Moraes, D.1    Kaplon, J.2    Nygard, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.