메뉴 건너뛰기




Volumn 38, Issue 3, 2011, Pages 1534-1546

Material separation in x-ray CT with energy resolved photon-counting detectors

Author keywords

CT; K edge; material separation; photon counting detectors; spectral CT

Indexed keywords

COMPUTERIZED TOMOGRAPHY; MERGERS AND ACQUISITIONS; PHANTOMS; PHOTONS; SEPARATION; TISSUE; VECTOR SPACES; X RAYS;

EID: 79952172950     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3553401     Document Type: Article
Times cited : (191)

References (36)
  • 1
    • 0022528983 scopus 로고
    • Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies
    • DOI 10.1118/1.595958
    • W. A. Kalender, W. H. Perman, J. R. Vetter, and E. Klotz, " Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies.," Med. Phys. 0094-2405 13, 334-339 (1986). 10.1118/1.595958 (Pubitemid 16062265)
    • (1986) Medical Physics , vol.13 , Issue.3 , pp. 334-339
    • Kalender, W.A.1    Perman, W.H.2    Vetter, J.R.3    Klotz, E.4
  • 2
    • 0021248688 scopus 로고
    • An implementation of dual energy CT scanning
    • W. Marshall, E. Hall, A. Doost-Hoseini, R. Alvarez, A. Macovski, and D. Cassel, " An implementation of dual energy CT scanning.," J. Comput. Assist. Tomogr. 0363-8715 8, 745-749 (1984). 10.1097/00004728-198408000-00029 (Pubitemid 14097070)
    • (1984) Journal of Computer Assisted Tomography , vol.8 , Issue.4 , pp. 745-749
    • Marshall, W.1    Hall, E.2    Doost-Hoseini, A.3
  • 3
    • 0019408837 scopus 로고
    • Initial results with prereconstruction dual-energy computed tomography (PREDECT)
    • W. H. Marshall, Jr., R. E. Alvarez, and A. Macovski, " Initial results with prereconstruction dual-energy computed tomography (PREDECT).," Radiology 0033-8419 140, 421-430 (1981). (Pubitemid 11039972)
    • (1981) Radiology , vol.140 , Issue.2 , pp. 421-430
    • Marshall Jr., W.H.1    Alvarez, R.E.2    Macovski, A.3
  • 6
    • 1642380221 scopus 로고    scopus 로고
    • Comparison of dual energy detector system performance
    • DOI 10.1118/1.1645679
    • R. E. Alvarez, J. A. Seibert, and S. K. Thompson, " Comparison of dual energy detector system performance.," Med. Phys. 0094-2405 31, 556-565 (2004). 10.1118/1.1645679 (Pubitemid 38381018)
    • (2004) Medical Physics , vol.31 , Issue.3 , pp. 556-565
    • Alvarez, R.E.1    Seibert, J.A.2    Thompson, S.K.3
  • 7
    • 0017811386 scopus 로고
    • Split detector computed tomography: a preliminary report
    • R. A. Brooks and G. Di Chiro, " Split-detector computed tomography: A preliminary report.," Radiology 0033-8419 126, 255-257 (1978). (Pubitemid 8267058)
    • (1978) Radiology , vol.126 , Issue.1 , pp. 255-257
    • Brooks, R.A.1    Di Chiro, G.2
  • 8
    • 0018844603 scopus 로고
    • Experimental dual xenon detectors for quantitative CT and spectral artifact correction
    • DOI 10.1118/1.594672
    • D. J. Drost and A. Fenster, " Experimental dual xenon detectors for quantitative CT and spectral artifact correction.," Med. Phys. 0094-2405 7, 101-107 (1980). 10.1118/1.594672 (Pubitemid 10147248)
    • (1980) Medical Physics , vol.7 , Issue.2 , pp. 101-107
    • Drost, D.J.1    Fenster, A.2
  • 9
    • 0034036231 scopus 로고    scopus 로고
    • Depth-segmented detector for x-ray absorptiometry
    • DOI 10.1118/1.598982
    • G. M. Stevens and N. J. Pelc, " Depth-segmented detector for x-ray absorptiometry.," Med. Phys. 0094-2405 27, 1174-1184 (2000). 10.1118/1.598982 (Pubitemid 30350031)
    • (2000) Medical Physics , vol.27 , Issue.5 , pp. 1174-1184
    • Stevens, G.M.1    Pelc, N.J.2
  • 10
    • 65549150272 scopus 로고    scopus 로고
    • Spectral rhoZ-projection method for characterization of body fluids in computed tomography: Ex vivo experiments
    • 1076-6332, 10.1016/j.acra.2009.01.002
    • A. H. Mahnken, S. Stanzel, and B. Heismann, " Spectral rhoZ-projection method for characterization of body fluids in computed tomography: Ex vivo experiments.," Acad. Radiol. 1076-6332 16, 763-769 (2009). 10.1016/j.acra.2009.01.002
    • (2009) Acad. Radiol. , vol.16 , pp. 763-769
    • Mahnken, A.H.1    Stanzel, S.2    Heismann, B.3
  • 11
    • 63849101176 scopus 로고    scopus 로고
    • Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration
    • 0094-2405, 10.1118/1.3083567
    • A. N. Primak, J. C. Ramirez Giraldo, X. Liu, L. Yu, and C. H. McCollough, " Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration.," Med. Phys. 0094-2405 36, 1359-1369 (2009). 10.1118/1.3083567
    • (2009) Med. Phys. , vol.36 , pp. 1359-1369
    • Primak, A.N.1    Ramirez Giraldo, J.C.2    Liu, X.3    Yu, L.4    McCollough, C.H.5
  • 12
    • 68149162621 scopus 로고    scopus 로고
    • Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method
    • 0094-2405, 10.1118/1.3157098
    • M. Saito, " Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method.," Med. Phys. 0094-2405 36, 3631-3642 (2009). 10.1118/1.3157098
    • (2009) Med. Phys. , vol.36 , pp. 3631-3642
    • Saito, M.1
  • 14
    • 33747603940 scopus 로고    scopus 로고
    • Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging
    • DOI 10.1088/0031-9155/51/17/010, PII S0031915506213976, 010
    • P. M. Shikhaliev, " Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging.," Phys. Med. Biol. 0031-9155 51, 4267-4287 (2006). 10.1088/0031-9155/51/17/010 (Pubitemid 44261844)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.17 , pp. 4267-4287
    • Shikhaliev, P.M.1
  • 16
    • 0032308575 scopus 로고    scopus 로고
    • High resolution x-ray imaging using a silicon strip detector
    • E. Beuville, R. Cahn, B. Cederstrom, M. Danielsson, A. L. Hall, B. Hasegawa, L. Luo, M. Lundqvist, D. Nygren, E. Oltman, and J. Walton, " High resolution x-ray imaging using a silicon strip detector.," IEEE Trans. Nucl. Sci. 0018-9499 45, 3059-3063 (1998). 10.1109/23.737664 (Pubitemid 128741100)
    • (1998) IEEE Transactions on Nuclear Science , vol.45 , Issue.PART 2 , pp. 3059-3063
    • Beuville, E.1    Cahn, R.2    Cederstrom, B.3    Danielsson, M.4
  • 18
    • 0019520280 scopus 로고
    • Dual energy film subtraction technique for detecting calcification in solitary pulmonary nodules
    • R. A. Kruger, J. D. Armstrong, J. A. Sorenson, and L. T. Niklason, " Dual energy film subtraction technique for detecting calcification in solitary pulmonary nodules.," Radiology 0033-8419 140, 213-219 (1981). (Pubitemid 11067746)
    • (1981) Radiology , vol.140 , Issue.1 , pp. 213-219
    • Kruger, R.A.1    Armstrong, J.D.2    Sorenson, J.A.3    Niklason, L.T.4
  • 19
    • 0023156134 scopus 로고
    • Two postprocessing CT techniques for determining the composition of trabecular bone
    • DOI 10.1097/00004424-198703000-00005
    • M. M. Goodsitt, D. I. Rosenthal, W. R. Reinus, and J. Coumas, " Two postprocessing CT techniques for determining the composition of trabecular bone.," Invest. Radiol. 0020-9996 22, 209-215 (1987). 10.1097/00004424- 198703000-00005 (Pubitemid 17035212)
    • (1987) Investigative Radiology , vol.22 , Issue.3 , pp. 209-215
    • Goodsitt, M.M.1    Rosenthal, D.I.2    Reinus, W.R.3    Coumas, J.4
  • 20
    • 65449156824 scopus 로고    scopus 로고
    • Quantitative imaging of element composition and mass fraction using dual-energy CT: Three-material decomposition
    • 0094-2405, 10.1118/1.3097632
    • X. Liu, L. Yu, A. N. Primak, and C. H. McCollough, " Quantitative imaging of element composition and mass fraction using dual-energy CT: Three-material decomposition.," Med. Phys. 0094-2405 36, 1602-1609 (2009). 10.1118/1.3097632
    • (2009) Med. Phys. , vol.36 , pp. 1602-1609
    • Liu, X.1    Yu, L.2    Primak, A.N.3    McCollough, C.H.4
  • 22
    • 34547137886 scopus 로고    scopus 로고
    • K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
    • DOI 10.1088/0031-9155/52/15/020, PII S0031915507383851, 020
    • E. Roessl and R. Proksa, " K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors.," Phys. Med. Biol. 0031-9155 52, 4679-4696 (2007). 10.1088/0031-9155/52/15/020 (Pubitemid 47103149)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.15 , pp. 4679-4696
    • Roessl, E.1    Proksa, R.2
  • 24
    • 0017108614 scopus 로고
    • Energy-selective reconstructions in x-ray computerized tomography
    • 0031-9155, 10.1088/0031-9155/21/5/002
    • R. E. Alvarez and A. Macovski, " Energy-selective reconstructions in x-ray computerized tomography.," Phys. Med. Biol. 0031-9155 21, 733-744 (1976). 10.1088/0031-9155/21/5/002
    • (1976) Phys. Med. Biol. , vol.21 , pp. 733-744
    • Alvarez, R.E.1    MacOvski, A.2
  • 25
    • 36849117674 scopus 로고
    • The absorption of incident quanta by atoms as defined by the mass photoelectric absorption coefficient and the mass scattering coefficient
    • 0021-8979, 10.1063/1.1698220
    • J. A. Victoreen, " The absorption of incident quanta by atoms as defined by the mass photoelectric absorption coefficient and the mass scattering coefficient.," J. Appl. Phys. 0021-8979 19, 855-860 (1948). 10.1063/1.1698220
    • (1948) J. Appl. Phys. , vol.19 , pp. 855-860
    • Victoreen, J.A.1
  • 27
    • 0019389495 scopus 로고
    • Generalized image combinations in dual KVP digital radiography
    • DOI 10.1118/1.595025
    • L. A. Lehmann, R. E. Alvarez, A. Macovski, W. R. Brody, N. J. Pelc, S. J. Riederer, and A. L. Hall, " Generalized image combinations in dual KVP digital radiography.," Med. Phys. 0094-2405 8, 659-667 (1981). 10.1118/1.595025 (Pubitemid 11004040)
    • (1981) Medical Physics , vol.8 , Issue.5 , pp. 659-667
    • Lehmann, L.A.1    Alvarez, R.E.2    Macovski, A.3
  • 30
    • 48349124497 scopus 로고    scopus 로고
    • Realistic CT simulation using the 4D XCAT phantom
    • 0094-2405, 10.1118/1.2955743
    • W. P. Segars, M. Mahesh, T. J. Beck, E. C. Frey, and B. M. Tsui, " Realistic CT simulation using the 4D XCAT phantom.," Med. Phys. 0094-2405 35, 3800-3808 (2008). 10.1118/1.2955743
    • (2008) Med. Phys. , vol.35 , pp. 3800-3808
    • Segars, W.P.1    Mahesh, M.2    Beck, T.J.3    Frey, E.C.4    Tsui, B.M.5
  • 34
    • 35148835355 scopus 로고    scopus 로고
    • Investigation of the use of photon counting X-ray detectors with energy discrimination capability for material decomposition in micro-computed tomography
    • DOI 10.1117/12.711711, Medical Imaging 2007: Physics of Medical Imaging
    • E. C. Frey, X. Wang, Y. Du, K. Taguchi, J. Xu, and B. M. W. Tsui, " Investigation of the use of photon counting x-ray detectors with energy discrimination capability for material decomposition in micro-computed tomography.," Proc. SPIE 0277-786X 6510, 65100A (2007). 10.1117/12.711711 (Pubitemid 47550105)
    • (2007) Progress in Biomedical Optics and Imaging - Proceedings of SPIE , vol.6510 , Issue.PART 1
    • Frey, E.C.1    Wang, X.2    Du, Y.3    Taguchi, K.4    Xu, J.5    Tsui, B.M.W.6
  • 35
    • 29144515780 scopus 로고    scopus 로고
    • Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: A simulation study
    • DOI 10.1088/0031-9155/50/24/004, PII S0031915505063220
    • P. M. Shikhaliev, " Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: A simulation study.," Phys. Med. Biol. 0031-9155 50, 5813-5827 (2005). 10.1088/0031-9155/50/24/004 (Pubitemid 41795835)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.24 , pp. 5813-5827
    • Shikhaliev, P.M.1
  • 36
    • 78149475974 scopus 로고    scopus 로고
    • An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors
    • 0094-2405, 10.1118/1.3429056
    • K. Taguchi, E. C. Frey, X. Wang, J. S. Iwanczyk, and W. C. Barber, " An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors.," Med. Phys. 0094-2405 37, 3957-3969 (2010). 10.1118/1.3429056
    • (2010) Med. Phys. , vol.37 , pp. 3957-3969
    • Taguchi, K.1    Frey, E.C.2    Wang, X.3    Iwanczyk, J.S.4    Barber, W.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.