메뉴 건너뛰기




Volumn 7258, Issue , 2009, Pages

Characterization of a novel photon counting detector for clinical CT: Count rate, energy resolution, and noise performance

Author keywords

ASIC; CdTe; CT; Photon counting

Indexed keywords

ASIC; CADMIUM TELLURIDE DETECTORS; CDTE; CDTE DETECTOR; CHARACTERIZATION STUDIES; COUNT RATES; CT; CT SYSTEM; DATA READOUT; DEAD TIME; DETECTOR MODELS; DETECTOR NOISE; DETECTOR PARAMETERS; DIRECT CONVERSION; ENERGY RESOLUTIONS; INPUT RATE; LOW-DOSE CT; MAXIMUM OUTPUT; MULTISLICE CT; NOISE PERFORMANCE; NON-PARALYZABLE; PERFORMANCE IMPROVEMENTS; PHOTON COUNTING; PHOTON COUNTING DETECTORS; TWO-DIMENSION; X-RAY COMPUTED TOMOGRAPHY; X-RAY DETECTOR;

EID: 66849122104     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.813915     Document Type: Conference Paper
Times cited : (98)

References (23)
  • 2
    • 14644437677 scopus 로고    scopus 로고
    • Photon computed tomography: Concept and initial results
    • P.M. Shikhaliev, X. Tong, S. Molloi, Photon computed tomography: Concept and initial results, Med. Phys., 32(2), 427-436, (2005).
    • (2005) Med. Phys. , vol.32 , Issue.2 , pp. 427-436
    • Shikhaliev, P.M.1    Tong, X.2    Molloi, S.3
  • 5
    • 84905114239 scopus 로고    scopus 로고
    • First experimental tests with a CdTe photon counting pixel detector hybridized with a medipix2 readout chip
    • M. Chmeissani, C. Frojdh, First Experimental Tests with a CdTe Photon Counting Pixel Detector Hybridized with a Medipix2 Readout Chip, IEEE Trans. Nucl. Sci., 51(5), 2379-2385 (2004).
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.5 , pp. 2379-2385
    • Chmeissani, M.1    Frojdh, C.2
  • 6
    • 66849120846 scopus 로고    scopus 로고
    • Dose-efficient system or digiltal mammography
    • M. Danielsson, and H. Bornefalk, Dose-efficient system or digiltal mammography, IEEE Trans. Nucl. Sci., 48(4), 1530-1536, (2001).
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , Issue.4 , pp. 1530-1536
    • Danielsson, M.1    Bornefalk, H.2
  • 8
    • 0021812629 scopus 로고
    • SNR and DQE analysis of broad spectrum X-ray imaging
    • Tapiovaara MJ, Wagner R., SNR and DQE analysis of broad spectrum X-ray imaging. Physics in Medicine and Biology. 30(6):519-529, (1985).
    • (1985) Physics in Medicine and Biology , vol.30 , Issue.6 , pp. 519-529
    • Tapiovaara, M.J.1    Wagner, R.2
  • 10
    • 0030265054 scopus 로고    scopus 로고
    • New gamma-ray detector structures for electron only charge carrier collection utilizing high-z compound semiconductors
    • B.E. Patt, J.S. Iwanczyk, G. Vilkelis, Y.J. Wang, New Gamma-ray Detector Structures for Electron Only Charge Carrier Collection Utilizing High-Z Compound Semiconductors, Nucl. Instr. & Meth. in Phys. Res,. A380, 276-281 (1996).
    • (1996) Nucl. Instr. & Meth. in Phys. Res , vol.A380 , pp. 276-281
    • Patt, B.E.1    Iwanczyk, J.S.2    Vilkelis, G.3    Wang, Y.J.4
  • 12
    • 0033461146 scopus 로고    scopus 로고
    • Detective quantum efficiency dependence on x-ray energy weighting in mammography
    • R. N. Cahn, B. Cederstrom, M. Danielsson, A. Hall, M. Lundqvist, and D. Nygren, Detective quantum efficiency dependence on x-ray energy weighting in mammography, Med. Phys., 26, 2680-2683, (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2680-2683
    • Cahn, R.N.1    Cederstrom, B.2    Danielsson, M.3    Hall, A.4    Lundqvist, M.5    Nygren, D.6
  • 13
    • 84905114239 scopus 로고    scopus 로고
    • First experimental tests with a CdTe photon counting pixel detector hybridized with a medipix2 readout chip
    • M. Chmeissani, C. Frojdh, First Experimental Tests with a CdTe Photon Counting Pixel Detector Hybridized with a Medipix2 Readout Chip, IEEE Trans. Nucl. Sci., 51(5), 2379-2385, (2004).
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.5 , pp. 2379-2385
    • Chmeissani, M.1    Frojdh, C.2
  • 14
    • 18644378201 scopus 로고    scopus 로고
    • A digital system based on a bi-chromatic x ray source and a single photon counting device: A single exposure dual energy mammography approach
    • M. Bisogni, M. Gambaccini, A digital system based on a bi-chromatic X ray source and a single photon counting device: a single exposure dual energy mammography approach, Proc. SPIE, 4682, 620-632, (2002).
    • (2002) Proc. SPIE , vol.4682 , pp. 620-632
    • Bisogni, M.1    Gambaccini, M.2
  • 15
    • 0042889399 scopus 로고    scopus 로고
    • X-ray Imaging Using Single Photon Processing with Semiconductor Pixel Detectors
    • B. Mikulec, M. Campbell, E. Heijne, X. Llopart, and L. Tlustos, X-ray Imaging Using Single Photon Processing with Semiconductor Pixel Detectors. NIM, A 511, 282-286, (2003).
    • (2003) NIM , vol.A 511 , pp. 282-286
    • Mikulec, B.1    Campbell, M.2    Heijne, E.3    Llopart, X.4    Tlustos, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.