메뉴 건너뛰기




Volumn 26, Issue 5, 2011, Pages 961-969

Three-dimensional finite element analysis of titanium and yttrium-stabilized zirconium dioxide abutments and implants

Author keywords

Dental implants; Finite element analysis; Implant abutments; Stress strain; Titanium; Zirc

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; TITANIUM; YTTRIA STABILIZED TETRAGONAL ZIRCONIA; YTTRIUM; ZIRCONIUM;

EID: 84857384011     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (67)

References (41)
  • 1
    • 0025583364 scopus 로고
    • A long term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws
    • Adell R, Eriksson B, Lekholm U, Brånemark PI, Jemt T. A long term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990;5:347-359.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 347-359
    • Adell, R.1    Eriksson, B.2    Lekholm, U.3    Brånemark, P.I.4    Jemt, T.5
  • 2
    • 0030184468 scopus 로고    scopus 로고
    • Osseointegrated implants for single-tooth replacement: A prospective 5-year multicenter study
    • Henry PJ, Laney WR, Jemt T, et al. Osseointegrated implants for single-tooth replacement: A prospective 5-year multicenter study. Int J Oral Maxillofac Implants 1996;11:450-455.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 450-455
    • Henry, P.J.1    Laney, W.R.2    Jemt, T.3
  • 4
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.I.4
  • 5
    • 23944474517 scopus 로고    scopus 로고
    • Prosthodontic considerations for predictable single-implant esthetics in the anterior maxilla
    • Holst S, Blatz MB, Hegenbarth E, Wichmann M, Eitner S. Prosthodontic considerations for predictable single-implant esthetics in the anterior maxilla. J Oral Maxillofac Surg 2005;63:89-96.
    • (2005) J Oral Maxillofac Surg , vol.63 , pp. 89-96
    • Holst, S.1    Blatz, M.B.2    Hegenbarth, E.3    Wichmann, M.4    Eitner, S.5
  • 6
    • 0031134420 scopus 로고    scopus 로고
    • A procedure for a modified cylindric titanium abutment
    • Marchack CB, Yamashita T. A procedure for a modified cylindric titanium abutment. J Prosthet Dent 1997;77:546-549.
    • (1997) J Prosthet Dent , vol.77 , pp. 546-549
    • Marchack, C.B.1    Yamashita, T.2
  • 7
    • 78651262006 scopus 로고    scopus 로고
    • Clinical trials in zirconia: A systematic review
    • Al-Amleh B, Lyons K, Swain M. Clinical trials in zirconia: A systematic review. J Oral Rehabil 2010;37:641-657.
    • (2010) J Oral Rehabil , vol.37 , pp. 641-657
    • Al-Amleh, B.1    Lyons, K.2    Swain, M.3
  • 8
    • 0032144008 scopus 로고    scopus 로고
    • Y-TZP ceramics for artificial joint replacements
    • Piconi C, Burger W, Richter HG, et al. Y-TZP ceramics for artificial joint replacements. Biomaterials 1998;19:1489-1494.
    • (1998) Biomaterials , vol.19 , pp. 1489-1494
    • Piconi, C.1    Burger, W.2    Richter, H.G.3
  • 10
    • 29244448325 scopus 로고    scopus 로고
    • Zirconium implant abutments: Fracture strength and influence of cyclic loading on retaining-screw loosening
    • Gehrke P, Dhom G, Brunner J, Wolf D, Degidi M, Piatelli A. Zirconium implant abutments: Fracture strength and influence of cyclic loading on retaining-screw loosening. Quintessence Int 2006;37:19-26.
    • (2006) Quintessence Int , vol.37 , pp. 19-26
    • Gehrke, P.1    Dhom, G.2    Brunner, J.3    Wolf, D.4    Degidi, M.5    Piatelli, A.6
  • 11
    • 0033080913 scopus 로고    scopus 로고
    • In vitro evaluation of the mutagenic and carcinogenic power of high purity zirconia ceramic
    • Covacci V, Bruzzese N, Maccauro G, et al. In vitro evaluation of the mutagenic and carcinogenic power of high purity zirconia ceramic. Biomaterials 1999;20:371-376.
    • (1999) Biomaterials , vol.20 , pp. 371-376
    • Covacci, V.1    Bruzzese, N.2    Maccauro, G.3
  • 12
    • 0032199149 scopus 로고    scopus 로고
    • Comparison between freestanding and tooth-connected partially stabilized zirconia implants after two years function in monkeys: A clinical and histologic study
    • Akagawa Y, Hosokawa R, Sato Y, Kamayama K. Comparison between freestanding and tooth-connected partially stabilized zirconia implants after two years function in monkeys: A clinical and histologic study. J Prosthet Dent 1998;80:551-558.
    • (1998) J Prosthet Dent , vol.80 , pp. 551-558
    • Akagawa, Y.1    Hosokawa, R.2    Sato, Y.3    Kamayama, K.4
  • 13
    • 20744457194 scopus 로고    scopus 로고
    • Bone tissue responses to surface modified zirconia implants: A histomorphometric and removal torque study in the rabbit
    • Sennerby L, Dasmah A, Larsson B, Iverhed M. Bone tissue responses to surface modified zirconia implants: A histomorphometric and removal torque study in the rabbit. Clin Implant Dent Relat Res 2005;7:13-20.
    • (2005) Clin Implant Dent Relat Res , vol.7 , pp. 13-20
    • Sennerby, L.1    Dasmah, A.2    Larsson, B.3    Iverhed, M.4
  • 14
    • 0036516450 scopus 로고    scopus 로고
    • Three-dimentional computerized stress analysis of commercially pure titanium and yttrium-partially stabilized zirconia implants
    • Kohal RJ, Papavasiliou G, Kamposiora P, Tripodakis A, Strub JR. Three-dimentional computerized stress analysis of commercially pure titanium and yttrium-partially stabilized zirconia implants. Int J Prosthodont 2002;15:189-194.
    • (2002) Int J Prosthodont , vol.15 , pp. 189-194
    • Kohal, R.J.1    Papavasiliou, G.2    Kamposiora, P.3    Tripodakis, A.4    Strub, J.R.5
  • 15
    • 2542639442 scopus 로고    scopus 로고
    • Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study
    • Glauser R, Sailer I, Wohlend A, Studer S, Schibli M, Scharer P. Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study. Int J Prosthodont 2004;17:285-290.
    • (2004) Int J Prosthodont , vol.17 , pp. 285-290
    • Glauser, R.1    Sailer, I.2    Wohlend, A.3    Studer, S.4    Schibli, M.5    Scharer, P.6
  • 16
    • 34948858085 scopus 로고    scopus 로고
    • Clinical outcome of customized zirconia abutments for single-implant restorations
    • Canullo L. Clinical outcome of customized zirconia abutments for single-implant restorations. Int J Prosthodont 2007;20:489-493.
    • (2007) Int J Prosthodont , vol.20 , pp. 489-493
    • Canullo, L.1
  • 17
    • 0032160238 scopus 로고    scopus 로고
    • The mucosal attachment at different abutments. An experimental study in dogs
    • Abrahamsson I, Berglundh T, Glantz P-O, Lindhe J. The mucosal attachment at different abutments. An experimental study in dogs. J Clin Periodontol 1998;25:721-727.
    • (1998) J Clin Periodontol , vol.25 , pp. 721-727
    • Abrahamsson, I.1    Berglundh, T.2    Glantz, P.-O.3    Lindhe, J.4
  • 18
    • 47249107322 scopus 로고    scopus 로고
    • Influence of abutment material on stability of peri-implant tissues: A systematic review
    • Linkevicius T, Apse P. Influence of abutment material on stability of peri-implant tissues: A systematic review. J Oral Maxillofac Implants 2008;23:449-456.
    • (2008) J Oral Maxillofac Implants , vol.23 , pp. 449-456
    • Linkevicius, T.1    Apse, P.2
  • 19
    • 34648820257 scopus 로고    scopus 로고
    • Three-dimensional finite element stress analysis of different core materials in maxillary implant-supported fixed partial dentures
    • Ozen J, Caglar A, Beydemir B, Aydin C, Dalkiz M. Three-dimensional finite element stress analysis of different core materials in maxillary implant-supported fixed partial dentures. Quintessence Int 2007; 38:e355-363.
    • (2007) Quintessence Int , vol.38 , pp. e355-363
    • Ozen, J.1    Caglar, A.2    Beydemir, B.3    Aydin, C.4    Dalkiz, M.5
  • 20
    • 0032038092 scopus 로고    scopus 로고
    • A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics
    • Teixeira ER, Sato Y, Akagawa Y, Shindoi N. A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics. J Oral Rehabil 1998;25:299-303.
    • (1998) J Oral Rehabil , vol.25 , pp. 299-303
    • Teixeira, E.R.1    Sato, Y.2    Akagawa, Y.3    Shindoi, N.4
  • 21
    • 77951936997 scopus 로고    scopus 로고
    • Evaluation of stresses occurring on three different zirconia dental implants: Three-dimensional finite element analysis
    • Caglar A, Bal BT, Aydin C, Yilmaz H, Ozkan S. Evaluation of stresses occurring on three different zirconia dental implants: Three-dimensional finite element analysis. Int J Oral Maxillofac Implants 2010;25:95-103.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 95-103
    • Caglar, A.1    Bal, B.T.2    Aydin, C.3    Yilmaz, H.4    Ozkan, S.5
  • 23
    • 0031309247 scopus 로고    scopus 로고
    • Influence of bone quality on stress distribution for endosseous implants
    • Holmes DC, Loftus JT. Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol 1997;23:104-111.
    • (1997) J Oral Implantol , vol.23 , pp. 104-111
    • Holmes, D.C.1    Loftus, J.T.2
  • 24
    • 0023882786 scopus 로고
    • A three-dimensional mathematical model of the human masticatory system predicting maximum possible bite forces
    • Koolstra JH, van Eijden TM, Weijs WA, Naeije M. A three-dimensional mathematical model of the human masticatory system predicting maximum possible bite forces. J Biomech 1988;21:563-576.
    • (1988) J Biomech , vol.21 , pp. 563-576
    • Koolstra, J.H.1    Van Eijden, T.M.2    Weijs, W.A.3    Naeije, M.4
  • 25
    • 33644797066 scopus 로고    scopus 로고
    • Effects of mesiodistal inclination of implants on stress distribution in implant-supported fixed prostheses
    • Caglar A, Aydin C, Ozen J, Yilmaz C, Korkmaz T. Effects of mesiodistal inclination of implants on stress distribution in implant-supported fixed prostheses. Int J Oral Maxillofac Implants 2006;21:36-44.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 36-44
    • Caglar, A.1    Aydin, C.2    Ozen, J.3    Yilmaz, C.4    Korkmaz, T.5
  • 26
    • 0038350018 scopus 로고    scopus 로고
    • Influence of functional forces on the biomechanics of implant-supported prostheses: A review
    • Sahin S, Cehreli MC, Yalcin E. Influence of functional forces on the biomechanics of implant-supported prostheses: A review. J Dent 2002;30:271-282.
    • (2002) J Dent , vol.30 , pp. 271-282
    • Sahin, S.1    Cehreli, M.C.2    Yalcin, E.3
  • 27
    • 0020776467 scopus 로고
    • Biomechanical considerations in osseointegrated prostheses
    • Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent 1983;49:843-848.
    • (1983) J Prosthet Dent , vol.49 , pp. 843-848
    • Skalak, R.1
  • 28
    • 84995804550 scopus 로고
    • Mechanical loading of Bränemark implants affects interfacial bone modeling and remodeling
    • Hoshaw SJ, Brunski JB, Cochran GVB. Mechanical loading of Bränemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 1994;9:345-360.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 345-360
    • Hoshaw, S.J.1    Brunski, J.B.2    Cochran, G.V.B.3
  • 29
    • 0031061799 scopus 로고    scopus 로고
    • Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation
    • Isidor F. Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation. Clin Oral Implants Res 1997;8:1-9.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 1-9
    • Isidor, F.1
  • 30
    • 0026488291 scopus 로고
    • Perspectives: Bone’s mechanical usage windows
    • Frost HM. Perspectives: Bone’s mechanical usage windows. Bone Miner 1992;10:257-271.
    • (1992) Bone Miner , vol.10 , pp. 257-271
    • Frost, H.M.1
  • 31
    • 18044403181 scopus 로고    scopus 로고
    • The influence of static and dynamic loading on marjinal bone reactions around osseointegrated an animal experimental study
    • Duyck J, Ronold HJ, Van Oosterwyck H, Naert I, Vander Stolen J, Ellingsen JE. The influence of static and dynamic loading on marjinal bone reactions around osseointegrated an animal experimental study. Clin Oral İmplant Res 2001;12:207-218.
    • (2001) Clin Oral İmplant Res , vol.12 , pp. 207-218
    • Duyck, J.1    Ronold, H.J.2    Van Oosterwyck, H.3    Naert, I.4    Vander Stolen, J.5    Ellingsen, J.E.6
  • 32
    • 0035377329 scopus 로고    scopus 로고
    • Application of finite element analysis in implant dentistry: A review of the literature
    • Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: A review of the literature. J Prosthet Dent 2001; 85:585-598.
    • (2001) J Prosthet Dent , vol.85 , pp. 585-598
    • Geng, J.P.1    Tan, K.B.2    Liu, G.R.3
  • 34
    • 0035751438 scopus 로고    scopus 로고
    • Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysis
    • Akça K, Iplikçioglu H. Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysis. Implant Dent 2001;10:238-245.
    • (2001) Implant Dent , vol.10 , pp. 238-245
    • Akça, K.1    Iplikçioglu, H.2
  • 36
    • 0033212422 scopus 로고    scopus 로고
    • The implant neck: Smooth or provided with retention elements
    • Hansson S. The implant neck: Smooth or provided with retention elements. Clin Oral Implants Res 1999;10:394-405.
    • (1999) Clin Oral Implants Res , vol.10 , pp. 394-405
    • Hansson, S.1
  • 37
    • 0026266914 scopus 로고
    • Three-dimensional finite element stress analysis in and around the Screw-Vent implant
    • Clelland NL, Ismail YH, Zaki HS, Pipko D. Three-dimensional finite element stress analysis in and around the Screw-Vent implant. Int J Oral Maxillofac Implants 1991;6:391-398.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 391-398
    • Clelland, N.L.1    Ismail, Y.H.2    Zaki, H.S.3    Pipko, D.4
  • 38
    • 0032917811 scopus 로고    scopus 로고
    • Zirconia as a ceramic biomaterial
    • Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 1999;20:1-25.
    • (1999) Biomaterials , vol.20 , pp. 1-25
    • Piconi, C.1    Maccauro, G.2
  • 39
    • 22644448001 scopus 로고    scopus 로고
    • Flexural strength of a layered zirconia and porcelain dental all-ceramic system
    • White SN, Miklus VG, McLaren EA, Lang LA, Caputo AA. Flexural strength of a layered zirconia and porcelain dental all-ceramic system. J Prosthet Dent 2005;94:125-131.
    • (2005) J Prosthet Dent , vol.94 , pp. 125-131
    • White, S.N.1    Miklus, V.G.2    McLaren, E.A.3    Lang, L.A.4    Caputo, A.A.5
  • 40
    • 0035348103 scopus 로고    scopus 로고
    • Flextural strength of Cerec 2 machined and jointed InCeram Alumina and InCeram Zirconia bars
    • Apholt W, Bindl A, Luty H, Mormann WH. Flextural strength of Cerec 2 machined and jointed InCeram Alumina and InCeram Zirconia bars. Dent Mater 2001;17:260-267.
    • (2001) Dent Mater , vol.17 , pp. 260-267
    • Apholt, W.1    Bindl, A.2    Luty, H.3    Mormann, W.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.