메뉴 건너뛰기




Volumn 10, Issue 4, 2001, Pages 238-245

Evaluation of the Effect of the Residual Bone Angulation on Implant-Supported Fixed Prosthesis in Mandibular Posterior Edentulism Part II: 3-D Finite Element Stress Analysis

Author keywords

Bucco lingual angulation; Finite element stress analyses; Mandibular posterior edentulism

Indexed keywords

ARTICLE; BIOLOGICAL MODEL; COMPUTER SIMULATION; DENTAL SURGERY; DENTURE; EDENTULOUSNESS; FINITE ELEMENT ANALYSIS; HUMAN; MANDIBLE; MASTICATION; MECHANICAL STRESS; MOLAR TOOTH; PATHOLOGY; PATHOPHYSIOLOGY; PREMOLAR TOOTH; SURFACE PROPERTY; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 0035751438     PISSN: 10566163     EISSN: None     Source Type: Journal    
DOI: 10.1097/00008505-200110000-00006     Document Type: Article
Times cited : (28)

References (46)
  • 1
    • 0030144715 scopus 로고    scopus 로고
    • A 5-year prospective multicenter follow-up report on overdentures supported by osseointegrated implants
    • Jemt T, Chai J, Harnett J, et al. A 5-year prospective multicenter follow-up report on overdentures supported by osseointegrated implants. Int J Oral Maxillofac Implants. 1996;11:291-298.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 291-298
    • Jemt, T.1    Chai, J.2    Harnett, J.3
  • 2
    • 0027793057 scopus 로고
    • Oral implant treatment in posterior partially edentulous jaws: A 5-year follow-up report
    • Jemt T, Lekholm U. Oral implant treatment in posterior partially edentulous jaws: A 5-year follow-up report. Int J Oral Maxillofac Implants. 1993;8:635-640.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 635-640
    • Jemt, T.1    Lekholm, U.2
  • 3
    • 0031088298 scopus 로고    scopus 로고
    • A multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Preliminary results at 6 or more months of loading
    • Robert AL, Donald SC, Thomas GW, et al. A multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Preliminary results at 6 or more months of loading. Int J Oral Maxillofac Implants. 1997;12:237-242.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 237-242
    • Robert, A.L.1    Donald, S.C.2    Thomas, G.W.3
  • 4
    • 0032016827 scopus 로고    scopus 로고
    • Treatment outcomes of patients with implant-supported fixed partial prostheses
    • Wyatt CCL, Zarb GA. Treatment outcomes of patients with implant-supported fixed partial prostheses. Int J Oral Maxillofac Implants. 1998;13:204-211.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 204-211
    • Wyatt, C.C.L.1    Zarb, G.A.2
  • 5
    • 0024724096 scopus 로고
    • Osseointegrated implants in the treatment of partially edentulous patients: A preliminary study on 876 consecutively placed fixtures
    • Jemt T, Leckholm U, Adell R. Osseointegrated implants in the treatment of partially edentulous patients: A preliminary study on 876 consecutively placed fixtures. Int J Oral Maxillofac Implants. 1989;4:211-217.
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 211-217
    • Jemt, T.1    Leckholm, U.2    Adell, R.3
  • 6
    • 0026874095 scopus 로고
    • A retrospective evaluation of endosseous titanium implants in the partially edentulous patient
    • Pylant T, Triplett RG, Key MC, et al. A retrospective evaluation of endosseous titanium implants in the partially edentulous patient. Int J Oral Maxillofac Implants. 1992;7:195-202.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 195-202
    • Pylant, T.1    Triplett, R.G.2    Key, M.C.3
  • 7
    • 0026168264 scopus 로고
    • Tissue integrated prostheses on malaligned implants in a partially edentulous patient. A clinical report
    • Koumjian HK, Smith RA. Tissue integrated prostheses on malaligned implants in a partially edentulous patient. A clinical report. Int J Oral Maxillofac Implants. 1991;6:211-214.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 211-214
    • Koumjian, H.K.1    Smith, R.A.2
  • 8
    • 0029303274 scopus 로고
    • Bending overload and implant fracture. A retrospective clinical analysis
    • Rangert B, Krogh PHJ, Langer B, et al. Bending overload and implant fracture. A retrospective clinical analysis. Int J Oral Maxillofac Implants. 1995;10:326-334.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 326-334
    • Rangert, B.1    Krogh, P.H.J.2    Langer, B.3
  • 9
    • 0032020453 scopus 로고    scopus 로고
    • In vivo horizontal bending moment on implants
    • Richter EJ. In vivo horizontal bending moment on implants. Int J Oral Maxillofac Implants. 1998;13:232-244.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 232-244
    • Richter, E.J.1
  • 10
    • 0026832538 scopus 로고
    • Failures and complications in 127 consecutively placed fixed partial prostheses supported by Branemark implants: From prosthetic treatment to first annual checkup
    • Jemt T, Linden B, Lekholm U. Failures and complications in 127 consecutively placed fixed partial prostheses supported by Branemark implants: From prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants. 1992;7:40-44.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 40-44
    • Jemt, T.1    Linden, B.2    Lekholm, U.3
  • 11
    • 84995802281 scopus 로고
    • Free standing versus implant tooth interconnected restorations: Understanding the prosthodontic perspective
    • Kay HB. Free standing versus implant tooth interconnected restorations: Understanding the prosthodontic perspective. Int J Periodont Rest Dent. 1993; 13:47-69.
    • (1993) Int J Periodont Rest Dent , vol.13 , pp. 47-69
    • Kay, H.B.1
  • 12
    • 0029320011 scopus 로고
    • Bridges supported by free standing implants versus bridges supported by tooth and implant
    • Olsson M, Gunne J, Astrand P, et al. Bridges supported by free standing implants versus bridges supported by tooth and implant. Clin Oral Implants Res. 1995;6:114-121.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 114-121
    • Olsson, M.1    Gunne, J.2    Astrand, P.3
  • 14
    • 0024661223 scopus 로고
    • Basic biomechanics of dental implants in prosthetic dentistry
    • Richter EJ. Basic biomechanics of dental implants in prosthetic dentistry. J Prosthet Dent. 1989;61:602-609.
    • (1989) J Prosthet Dent , vol.61 , pp. 602-609
    • Richter, E.J.1
  • 15
    • 0027349832 scopus 로고
    • Biomechanical considerations of prosthodontic therapy: The urgency of research into alveolar bone responses
    • Lavelle CLB. Biomechanical considerations of prosthodontic therapy: The urgency of research into alveolar bone responses. Int J Oral Maxillofac Implants. 1993;8:179-185.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 179-185
    • Lavelle, C.L.B.1
  • 16
    • 0027357731 scopus 로고
    • The biomechanics of force distribution in implant-supported prostheses
    • Weinberg LA. The biomechanics of force distribution in implant-supported prostheses. Int J Oral Maxillofac Implants. 1993;8:19-31.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 19-31
    • Weinberg, L.A.1
  • 17
    • 0032018672 scopus 로고    scopus 로고
    • Clinical and histologic features of a non-axial load on the osseointegrated of a posterior mandibular implant: Report of a case
    • Piatelli A, Scarano A, Paolantonio M. Clinical and histologic features of a non-axial load on the osseointegrated of a posterior mandibular implant: Report of a case. Int J Oral Maxillofac Implants. 1998;13:273-275.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 273-275
    • Piatelli, A.1    Scarano, A.2    Paolantonio, M.3
  • 18
    • 0033129618 scopus 로고    scopus 로고
    • Osseointegration of rough acid-etched titanium implants: 5-year follow-up of 100 Minimatic implants
    • Leonardis DD, Garg KA, Pecora EG. Osseointegration of rough acid-etched titanium implants: 5-year follow-up of 100 Minimatic implants. Int J Oral Maxillofac Implants. 1999;14:384-391.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 384-391
    • Leonardis, D.D.1    Garg, K.A.2    Pecora, E.G.3
  • 19
    • 0031602263 scopus 로고    scopus 로고
    • Generalizations regarding the process and phenomenon of osseointegration. Part I. In-vivo studies
    • Masuda T, Yliheikkila PK, Felton DA, et al. Generalizations regarding the process and phenomenon of osseointegration. Part I. In-vivo studies. Int J Oral Maxillofac Implants. 1998;13:17-29.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 17-29
    • Masuda, T.1    Yliheikkila, P.K.2    Felton, D.A.3
  • 20
    • 0032021129 scopus 로고    scopus 로고
    • Generalizations regarding the process and phenomenon of osseointegration. Part II. In-vitro studies
    • Cooper LF, Masuda T, Yliheikkila PK, et al. Generalizations regarding the process and phenomenon of osseointegration. Part II. In-vitro studies. Int J Oral Maxillofac Implants. 1998;13:163-174.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 163-174
    • Cooper, L.F.1    Masuda, T.2    Yliheikkila, P.K.3
  • 21
    • 85016033318 scopus 로고
    • Mechanical loading of Branemark implants affects interfacial bone modeling and remodeling
    • Hoshaw SJ, Brunski JB, Cochran GVB. Mechanical loading of Branemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants. 1994;9:345-360.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 345-360
    • Hoshaw, S.J.1    Brunski, J.B.2    Cochran, G.V.B.3
  • 22
    • 0026921680 scopus 로고
    • Fixture design and overload influence marginal bone loss and implant success in the Branemark system
    • Quirynen M, Naert I, Steenberghe D. Fixture design and overload influence marginal bone loss and implant success in the Branemark system. Clin Oral Implants Res. 1992;3:104-111.
    • (1992) Clin Oral Implants Res , vol.3 , pp. 104-111
    • Quirynen, M.1    Naert, I.2    Steenberghe, D.3
  • 23
    • 0032038092 scopus 로고    scopus 로고
    • A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics
    • Teixeira ER, Sato Y, Akagawa Y, et al. A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics. J Oral Rehabil. 1998;25:299-303.
    • (1998) J Oral Rehabil , vol.25 , pp. 299-303
    • Teixeira, E.R.1    Sato, Y.2    Akagawa, Y.3
  • 24
    • 84989001629 scopus 로고
    • Photoelastic analysis of stress distribution transmitted from a fixed prosthesis attached to osseointegrated implants
    • Waskewicz GA, Ostrowski JS, Parks VJ. Photoelastic analysis of stress distribution transmitted from a fixed prosthesis attached to osseointegrated implants. Int J Oral Maxillofac Implants. 1994;9:405-411.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 405-411
    • Waskewicz, G.A.1    Ostrowski, J.S.2    Parks, V.J.3
  • 25
    • 0027767982 scopus 로고
    • A photoelastic and strain gauge analysis of angled abutments for an implant system
    • Clelland NL, Gilat A, McGlumphy EA, et al. A photoelastic and strain gauge analysis of angled abutments for an implant system. Int J Oral Maxillofac Implants. 1993;8:541-548.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 541-548
    • Clelland, N.L.1    Gilat, A.2    McGlumphy, E.A.3
  • 27
    • 0020776467 scopus 로고
    • Biomechanical considerations in osseointegrated prostheses
    • Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent. 1983;49:843-848.
    • (1983) J Prosthet Dent , vol.49 , pp. 843-848
    • Skalak, R.1
  • 28
    • 0027792619 scopus 로고
    • A method of selecting the best implant prosthesis design option using three-dimensional finite element analysis
    • Kregzde M. A method of selecting the best implant prosthesis design option using three-dimensional finite element analysis. Int J Oral Maxillofac Implants. 1993;8:662-673.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 662-673
    • Kregzde, M.1
  • 29
    • 0027620595 scopus 로고
    • A three-dimensional finite element analysis of bone around dental implants in an edentulous human mandible
    • Meijer HJA, Starmans FJM, Steen WHA, et al. A three-dimensional finite element analysis of bone around dental implants in an edentulous human mandible. Arch Oral Biol. 1993;38:491-496.
    • (1993) Arch Oral Biol , vol.38 , pp. 491-496
    • Meijer, H.J.A.1    Starmans, F.J.M.2    Steen, W.H.A.3
  • 30
    • 0032060144 scopus 로고    scopus 로고
    • Mandibular implant retained overdenture: Finite element analysis of two anchorage systems
    • Meniccuci G, Lorenzetti M, Pera P, et al. Mandibular implant retained overdenture: Finite element analysis of two anchorage systems. Int J Oral Maxillofac Implants. 1998;13:369-376.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 369-376
    • Meniccuci, G.1    Lorenzetti, M.2    Pera, P.3
  • 31
    • 0029175465 scopus 로고
    • Three-dimensional finite element model of a human mandible incorporating six osseointegrated implants for stress analysis of mandibular cantilever prostheses
    • Zyl PP, Grundling NL, Jooste CH, et al. Three-dimensional finite element model of a human mandible incorporating six osseointegrated implants for stress analysis of mandibular cantilever prostheses. Int J Oral Maxillofac Implants. 1995; 10:51-57.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 51-57
    • Zyl, P.P.1    Grundling, N.L.2    Jooste, C.H.3
  • 32
    • 0024782190 scopus 로고
    • Numerical investigations of the influence of implant shape on stress distribution in the jaw bone
    • Siegele D, Soltesz U. Numerical investigations of the influence of implant shape on stress distribution in the jaw bone. Int J Oral Maxillofac Implants. 1989;4:333-340.
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 333-340
    • Siegele, D.1    Soltesz, U.2
  • 33
    • 0027031544 scopus 로고
    • Comparison of stress transmissions in the IMZ implant system with polyoxymethylene or titanium intramobile element: A finite element stress analysis
    • Homes DC, Grisgsby WR, Goel VK, et al. Comparison of stress transmissions in the IMZ implant system with polyoxymethylene or titanium intramobile element: A finite element stress analysis. Int J Oral Maxillofac Implants. 1992;7: 450-458.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 450-458
    • Homes, D.C.1    Grisgsby, W.R.2    Goel, V.K.3
  • 34
    • 0020712495 scopus 로고
    • Stress analysis of a human tooth using a three-dimensional finite element model
    • Rubin C, Krishnamurthy N, Capilouto E, et al. Stress analysis of a human tooth using a three-dimensional finite element model. J Dent Res. 1983;62:82-86.
    • (1983) J Dent Res , vol.62 , pp. 82-86
    • Rubin, C.1    Krishnamurthy, N.2    Capilouto, E.3
  • 35
    • 0026266914 scopus 로고
    • Three-dimensional finite element stress analysis in and around the screw-vent implant
    • Clelland NL, Ismail YH, Zaki HS, et al. Three-dimensional finite element stress analysis in and around the screw-vent implant. Int J Oral Maxillofac Implants. 1991;6:391-398.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 391-398
    • Clelland, N.L.1    Ismail, Y.H.2    Zaki, H.S.3
  • 36
    • 0030208125 scopus 로고    scopus 로고
    • Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis
    • Sertgöz A, Güvener S. Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis. J Prosthet Dent. 1996;76:165-169.
    • (1996) J Prosthet Dent , vol.76 , pp. 165-169
    • Sertgöz, A.1    Güvener, S.2
  • 37
    • 0031267997 scopus 로고    scopus 로고
    • 3D-FEA of osseointegration percentages and patterns on implant bone interfacial stresses
    • Papavasiliou G, Kamposiora P, Bayne SC, et al. 3D-FEA of osseointegration percentages and patterns on implant bone interfacial stresses. J Dent. 1997; 25:485-491.
    • (1997) J Dent , vol.25 , pp. 485-491
    • Papavasiliou, G.1    Kamposiora, P.2    Bayne, S.C.3
  • 38
    • 0027829234 scopus 로고
    • Non-linear finite element contact analysis of dental implant components
    • Sakaguchi RL, Borgersen SE. Non-linear finite element contact analysis of dental implant components. Int J Oral Maxillofac Implants. 1993;8:655-661.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 655-661
    • Sakaguchi, R.L.1    Borgersen, S.E.2
  • 39
    • 0027571102 scopus 로고
    • A comparison of three finite element models of an edentulous mandible provided with implants
    • Meijer HJA, Starmans FJM, Bosman F, et al. A comparison of three finite element models of an edentulous mandible provided with implants. Arch Oral Biol. 1993;20:147-157.
    • (1993) Arch Oral Biol , vol.20 , pp. 147-157
    • Meijer, H.J.A.1    Starmans, F.J.M.2    Bosman, F.3
  • 40
    • 0030338099 scopus 로고    scopus 로고
    • Three-dimensional finite element analysis of stress distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function
    • Papavasiliou G, Kamposiora P, Bayne SC, et al. Three-dimensional finite element analysis of stress distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function. J Prosthet Dent. 1996;76:633-640.
    • (1996) J Prosthet Dent , vol.76 , pp. 633-640
    • Papavasiliou, G.1    Kamposiora, P.2    Bayne, S.C.3
  • 41
    • 0025463278 scopus 로고
    • Finite element analysis of fixed prostheses attached to osseointegrated implants
    • Williams KR, Watson CJ, Murphy WM, et al. Finite element analysis of fixed prostheses attached to osseointegrated implants. Quintessence Int. 1990;21:563-570.
    • (1990) Quintessence Int , vol.21 , pp. 563-570
    • Williams, K.R.1    Watson, C.J.2    Murphy, W.M.3
  • 42
    • 0022726533 scopus 로고
    • Prosthetic considerations for the utilization of osseointegrated fixtures in the partially edentulous arch
    • Sullivan DY. Prosthetic considerations for the utilization of osseointegrated fixtures in the partially edentulous arch. Int J Oral Maxillofac Implants. 1986; 1:39-45.
    • (1986) Int J Oral Maxillofac Implants , vol.1 , pp. 39-45
    • Sullivan, D.Y.1
  • 43
    • 0031612903 scopus 로고    scopus 로고
    • Influence of restoration type on stress distribution in bone around implants: A three-dimensional finite element analysis
    • Stegaroiu R, Sato T, Kusakari H, et al. Influence of restoration type on stress distribution in bone around implants: A three-dimensional finite element analysis. Int J Oral Maxillofac Implants. 1998;13:82-90.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 82-90
    • Stegaroiu, R.1    Sato, T.2    Kusakari, H.3
  • 44
    • 0010485406 scopus 로고
    • Functional response
    • Brånemark P-I, Zarb GA, Albrektsson T, eds. Chicago: Quintessence;
    • Carlsson GE, Haraldson T. Functional response. In: Brånemark P-I, Zarb GA, Albrektsson T, eds. Tissue-Integrated Prostheses. Chicago: Quintessence; 1985:155-163.
    • (1985) Tissue-Integrated Prostheses , pp. 155-163
    • Carlsson, G.E.1    Haraldson, T.2
  • 45
    • 0029303075 scopus 로고
    • Occlusal force and oral sensibility measured in partially edentulous patients with ITI implants
    • Mericske-Stern R, Assal P, Mericske E, et al. Occlusal force and oral sensibility measured in partially edentulous patients with ITI implants. Int J Oral Maxillofac Implants. 1995;10: 345-354.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 345-354
    • Mericske-Stern, R.1    Assal, P.2    Mericske, E.3
  • 46
    • 0035226275 scopus 로고    scopus 로고
    • Evaluation of the effect of the residual bone angulation on implant-supported fixed prostheses in mandibular posterior edentulism. Part I: Spiral computed tomography study
    • Akça K, Iplikc̊ioǧlu H. Evaluation of the effect of the residual bone angulation on implant-supported fixed prostheses in mandibular posterior edentulism. Part I: Spiral computed tomography study. Implant Dent. 2001; 3:216-222.
    • (2001) Implant Dent , vol.3 , pp. 216-222
    • Akça, K.1    Iplikc̊ioǧlu, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.