메뉴 건너뛰기




Volumn 9, Issue 1, 2012, Pages

A regenerative microchannel neural interface for recording from and stimulating peripheral axons in vivo

Author keywords

[No Author keywords available]

Indexed keywords

ASSISTIVE TECHNOLOGY; CURRENT FLOWS; ELECTROMYOGRAM; ELECTRONIC CIRCUITRY; EXTRACELLULAR POTENTIAL; IMPLANTED DEVICE; IN-VIVO; MICROCHANNEL ARRAY; MOTOR AXONS; MOTOR UNIT; MUSCLE ATROPHY; NERVE INJURIES; NEURAL INTERFACES; NOVEL DESIGN; PERIPHERAL NERVES; POTENTIAL SOLUTIONS; PROSTHETIC LIMB CONTROL; RAT SCIATIC NERVE; SMALL SIZE;

EID: 84856995666     PISSN: 17412560     EISSN: 17412552     Source Type: Journal    
DOI: 10.1088/1741-2560/9/1/016010     Document Type: Article
Times cited : (59)

References (61)
  • 2
    • 0024000488 scopus 로고
    • Inflammatory response to implants
    • Anderson J M 1988 Inflammatory response to implants ASAIO Trans. 34 101-7
    • (1988) ASAIO Trans. , vol.34 , pp. 101-107
    • Anderson, J.M.1
  • 4
    • 0030910808 scopus 로고    scopus 로고
    • Long term chronic recordings from peripheral sensory fibers using a sieve electrode array
    • DOI 10.1016/S0165-0270(97)02225-5, PII S0165027097022255
    • Bradley R M, Cao X, Akin T and Najafi K 1997 Long term chronic recordings from peripheral sensory fibers using a sieve electrode array J. Neurosci. Methods 73 177-86 (Pubitemid 27244814)
    • (1997) Journal of Neuroscience Methods , vol.73 , Issue.2 , pp. 177-186
    • Bradley, R.M.1    Cao, X.2    Akin, T.3    Najafi, K.4
  • 5
    • 0026471648 scopus 로고
    • Functional regeneration of glossopharyngeal nerve through micromachined sieve electrode arrays
    • Bradley R M, Smoke R H, Akin T and Najafi K 1992 Functional regeneration of glossopharyngeal nerve through micromachined sieve electrode arrays Brain Res. 594 84-90
    • (1992) Brain Res. , vol.594 , pp. 84-90
    • Bradley, R.M.1    Smoke, R.H.2    Akin, T.3    Najafi, K.4
  • 6
    • 0034001259 scopus 로고    scopus 로고
    • A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
    • DOI 10.1016/S0361-9230(99)00231-2, PII S0361923099002312
    • Branner A and Normann R A 2000 A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats Brain Res. Bull. 51 293-306 (Pubitemid 30126020)
    • (2000) Brain Research Bulletin , vol.51 , Issue.4 , pp. 293-306
    • Branner, A.1    Normann, R.A.2
  • 7
    • 0035068673 scopus 로고    scopus 로고
    • Selective stimulation of cat sciatic nerve using an array of varying-length microelectrodes
    • Branner A, Stein R B and Normann R A 2001 Selective stimulation of cat sciatic nerve using an array of varying-length microelectrodes J. Neurophysiol. 85 1585-94 PMID: 11287482 (Pubitemid 32280599)
    • (2001) Journal of Neurophysiology , vol.85 , Issue.4 , pp. 1585-1594
    • Branner, A.1    Stein, R.B.2    Normann, R.A.3
  • 8
    • 3142743126 scopus 로고    scopus 로고
    • Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs
    • discussion 16-8
    • Dhillon G S, Lawrence S M, Hutchinson D T and Horch K W 2004 Residual function in peripheral nerve stumps of amputees: implications for neural control of artificial limbs J. Hand Surg. 29 605-15 discussion 16-8
    • (2004) J. Hand Surg. , vol.29 , pp. 605-615
    • Dhillon, G.S.1    Lawrence, S.M.2    Hutchinson, D.T.3    Horch, K.W.4
  • 9
    • 58649114243 scopus 로고    scopus 로고
    • Novel MEA platform with PDMS microtunnels enables the detection of action potential propagation from isolated axons in culture
    • Dworak B J and Wheeler B C 2009 Novel MEA platform with PDMS microtunnels enables the detection of action potential propagation from isolated axons in culture Lab Chip 9 404-10
    • (2009) Lab Chip , vol.9 , pp. 404-410
    • Dworak, B.J.1    Wheeler, B.C.2
  • 10
    • 0022559394 scopus 로고
    • A peripheral nerve information transducer for amputees: Long-term multichannel recordings from rabbit peripheral nerves
    • Edell D J 1986 A peripheral nerve information transducer for amputees: long-term multichannel recordings from rabbit peripheral nerves IEEE Trans. Biomed. Eng. 33 203-14 (Pubitemid 16154070)
    • (1986) IEEE Transactions on Biomedical Engineering , vol.33 , Issue.2 , pp. 203-214
    • Edell, D.J.1
  • 14
    • 0030176010 scopus 로고    scopus 로고
    • Quantification of recruitment properties of multiple contact cuff electrodes
    • DOI 10.1109/86.506402
    • Grill W M Jr and Mortimer J T 1996 Quantification of recruitment properties of multiple contact cuff electrodes IEEE Trans. Rehabil. Eng. 4 49-62 (Pubitemid 26201282)
    • (1996) IEEE Transactions on Rehabilitation Engineering , vol.4 , Issue.2 , pp. 49-62
    • Grill Jr., W.M.1    Mortimer, J.T.2
  • 15
    • 0036230180 scopus 로고    scopus 로고
    • A stimulator for functional activation of denervated muscles
    • DOI 10.1046/j.1525-1594.2002.06951.x
    • Hofer C, Mayr W, Stohr H, Unger E and Kern H 2002 A stimulator for functional activation of denervated muscles Artif. Organs 26 276-9 (Pubitemid 34304605)
    • (2002) Artificial Organs , vol.26 , Issue.3 , pp. 276-279
    • Hofer, C.1    Mayr, W.2    Stohr, H.3    Unger, E.4    Kern, H.5
  • 16
    • 0001049979 scopus 로고
    • Nerve fiber activity during normal movements Soc
    • Hoffer J A, Marks W B and Rymer W Z 1974 Nerve fiber activity during normal movements Soc. Neurosci. Abstr 4 300
    • (1974) Neurosci. Abstr , vol.4 , pp. 300
    • Hoffer, J.A.1    Marks, W.B.2    Rymer, W.Z.3
  • 17
    • 0001489697 scopus 로고
    • Conduction velocity and the diameter of nerve fibres
    • Hursh J B 1939 Conduction velocity and the diameter of nerve fibres Am. J. Physiol. 127 131-9
    • (1939) Am. J. Physiol. , vol.127 , pp. 131-139
    • Hursh, J.B.1
  • 20
    • 0026926772 scopus 로고
    • Regeneration microelectrode array for peripheral nerve recording and stimulation
    • DOI 10.1109/10.256422
    • Kovacs G T, Storment C W and Rosen J M 1992 Regeneration microelectrode array for peripheral nerve recording and stimulation IEEE Trans. Biomed. Eng. 39 893-902 (Pubitemid 23121820)
    • (1992) IEEE Transactions on Biomedical Engineering , vol.39 , Issue.9 , pp. 893-902
    • Kovacs, G.T.A.1    Storment, C.W.2    Rosen, J.M.3
  • 23
    • 9644252908 scopus 로고    scopus 로고
    • Long term assessment of axonal regeneration through polyimide regenerative electrodes to interface the peripheral nerve
    • DOI 10.1016/j.biomaterials.2004.06.025, PII S0142961204005642
    • Lago N, Ceballos D, Rodriguez F J, Stieglitz T and Navarro X 2005 Long term assessment of axonal regeneration through polyimide regenerative electrodes to interface the peripheral nerve Biomaterials 26 2021-31 (Pubitemid 39575344)
    • (2005) Biomaterials , vol.26 , Issue.14 , pp. 2021-2031
    • Lago, N.1    Ceballos, D.2    J, R.F.3    Stieglitz, T.4    Navarro, X.5
  • 24
    • 34249296314 scopus 로고    scopus 로고
    • Neurobiological assessment of regenerative electrodes for bidirectional interfacing injured peripheral nerves
    • DOI 10.1109/TBME.2007.891168
    • Lago N, Udina E, Ramachandran A and Navarro X 2007a Neurobiological assessment of regenerative electrodes for bidirectional interfacing injured peripheral nerves IEEE Trans. Biomed. Eng. 54 1129-37 (Pubitemid 46815116)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.6 , pp. 1129-1137
    • Lago, N.1    Udina, E.2    Ramachandran, A.3    Navarro, X.4
  • 25
    • 33846678092 scopus 로고    scopus 로고
    • Assessment of biocompatibility of chronically implanted polyimide and platinum intrafascicular electrodes
    • DOI 10.1109/TBME.2006.886617, 12
    • Lago N, Yoshida K, Koch K P and Navarro X 2007b Assessment of biocompatibility of chronically implanted polyimide and platinum intrafascicular electrodes IEEE Trans. Biomed. Eng. 54 281-90 (Pubitemid 46188171)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.2 , pp. 281-290
    • Lago, N.1    Yoshida, K.2    Koch, K.P.3    Navarro, X.4
  • 26
    • 0017462744 scopus 로고
    • Analysis and microelectronic design of tubular electrode arrays intended for chronic, multiple single unit recording from captured nerve fibres
    • Loeb G E, Marks W B and Beatty P G 1977 Analysis and microelectronic design of tubular electrode arrays intended for chronic, multiple single-unit recording from captured nerve fibres Med. Biol. Eng. Comput. 15 195-201 (Pubitemid 8082494)
    • (1977) MED.BIOL.ENG.COMPUT. , vol.15 , Issue.2 , pp. 195-201
    • Loeb, G.E.1    Marks, W.B.2    Beatty, P.G.3
  • 27
    • 0024320175 scopus 로고
    • An intrafascicular electrode for recording of action potentials in peripheral nerves
    • Malagodi M S, Horch K W and Schoenberg A A 1989 An intrafascicular electrode for recording of action potentials in peripheral nerves Ann. Biomed. Eng. 17 397-410 (Pubitemid 19188602)
    • (1989) Annals of Biomedical Engineering , vol.17 , Issue.4 , pp. 397-410
    • Malagodi, M.S.1    Horch, K.W.2    Schoenberg, A.A.3
  • 28
    • 0032171705 scopus 로고    scopus 로고
    • Extracellular potentials from active myelinated fibers inside insulated and noninsulated peripheral nerve
    • Meier J H, Rutten W L and Boom H B 1998 Extracellular potentials from active myelinated fibers inside insulated and noninsulated peripheral nerve IEEE Trans. Biomed. Eng. 45 1146-53
    • (1998) IEEE Trans. Biomed. Eng. , vol.45 , pp. 1146-1153
    • Meier, J.H.1    Rutten, W.L.2    Boom, H.B.3
  • 30
    • 20644450105 scopus 로고    scopus 로고
    • Electrical stimulation of denervated muscles: First results of a clinical study
    • DOI 10.1111/j.1525-1594.2005.29035.x
    • Modlin M, Forstner C, Hofer C, Mayr W, Richter W, Carraro U, Protasi F and Kern H 2005 Electrical stimulation of denervated muscles: first results of a clinical study Artif. Organs 29 203-6 (Pubitemid 41648017)
    • (2005) Artificial Organs , vol.29 , Issue.3 , pp. 203-206
    • Modlin, M.1    Forstner, C.2    Hofer, C.3    Mayr, W.4    Richter, W.5    Carraro, U.6    Protasi, F.7    Kern, H.8
  • 32
    • 27644591279 scopus 로고    scopus 로고
    • A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems
    • Navarro X, Krueger T B, Lago N, Micera S, Stieglitz T and Dario P 2005 A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems J. Peripher. Nerv. Syst. 10 229-58
    • (2005) J. Peripher. Nerv. Syst. , vol.10 , pp. 229-258
    • Navarro, X.1    Krueger, T.B.2    Lago, N.3    Micera, S.4    Stieglitz, T.5    Dario, P.6
  • 33
    • 0034835683 scopus 로고    scopus 로고
    • Selective fascicular stimulation of the rat sciatic nerve with multipolar polyimide cuff electrodes
    • Navarro X, Valderrama E, Stieglitz T and Schuttler M 2001 Selective fascicular stimulation of the rat sciatic nerve with multipolar polyimide cuff electrodes Restorative Neurol. Neurosci. 18 9-21 (Pubitemid 32881790)
    • (2001) Restorative Neurology and Neuroscience , vol.18 , Issue.1 , pp. 9-21
    • Navarro, X.1    Valderrama, E.2    Stieglitz, T.3    Schuttler, M.4
  • 35
    • 0018574732 scopus 로고
    • A review of printed circuit microelectrodes and their production
    • DOI 10.1016/0165-0270(79)90019-0
    • Pickard R S 1979 A review of printed circuit microelectrodes and their production J. Neurosci. Methods 1 301-18 (Pubitemid 10163102)
    • (1979) Journal of Neuroscience Methods , vol.1 , Issue.4 , pp. 301-318
    • Pickard, R.S.1
  • 36
    • 0034283149 scopus 로고    scopus 로고
    • An improved configuration for the reduction of EMG in electrode cuff recordings: A theoretical approach
    • Rahal M, Winter J, Taylor J and Donaldson N 2000 An improved configuration for the reduction of EMG in electrode cuff recordings: a theoretical approach IEEE Trans. Biomed. Eng. 47 1281-4
    • (2000) IEEE Trans. Biomed. Eng. , vol.47 , pp. 1281-1284
    • Rahal, M.1    Winter, J.2    Taylor, J.3    Donaldson, N.4
  • 38
    • 0034542764 scopus 로고    scopus 로고
    • Selective recording of electroneurograms from the sciatic nerve of a dog with multi-electrode spiral cuffs
    • DOI 10.2170/jjphysiol.50.509
    • Rozman J, Zorko B and Bunc M 2000 Selective recording of electroneurograms from the sciatic nerve of a dog with multi-electrode spiral cuffs Japan. J. Physiol. 50 509-14 (Pubitemid 32010151)
    • (2000) Japanese Journal of Physiology , vol.50 , Issue.5 , pp. 509-514
    • Rozman, J.1    Zorko, B.2    Bunc, M.3
  • 39
    • 0036403701 scopus 로고    scopus 로고
    • Selective electrical interfaces with the nervous system
    • DOI 10.1146/annurev.bioeng.4.020702.153427
    • Rutten W L C 2002 Selective electrical interfaces with the nervous system Annu. Rev. Biomed. Eng. 4 407-52 (Pubitemid 35217427)
    • (2002) Annual Review of Biomedical Engineering , vol.4 , pp. 407-452
    • Rutten, W.L.C.1
  • 40
    • 0028945303 scopus 로고
    • 3D neuroelectronic interface devices for neuromuscular control: Design studies and realisation steps
    • Rutten W L C, Smit J P A, Rozijn T H and Meier J H 1995 3D neuroelectronic interface devices for neuromuscular control: design studies and realisation steps Biosens. Bioelectron. 10 141-53
    • (1995) Biosens. Bioelectron. , vol.10 , pp. 141-153
    • Rutten, W.L.C.1    Smit, J.P.A.2    Rozijn, T.H.3    Meier, J.H.4
  • 41
    • 0026106143 scopus 로고
    • Sensitivity and selectivity of intraneural stimulation using a silicon electrode array
    • Rutten W L C, Van Wier H and Put J M H 1991 Sensitivity and selectivity of intraneural stimulation using a silicon electrode array IEEE Trans. Biomed. Eng. 38 192-8
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , pp. 192-198
    • Rutten, W.L.C.1    Van Wier, H.2    Put, J.M.H.3
  • 42
    • 0030312294 scopus 로고    scopus 로고
    • Selective recording with a multi-contact nerve cuff electrode
    • Sahin M and Durand D M 1996 Selective recording with a multi-contact nerve cuff electrode Proc. IEEE Eng. Med. Biol. Soc. pp 369-70
    • (1996) Proc. IEEE Eng. Med. Biol. Soc. , pp. 369-370
    • Sahin, M.1    Durand, D.M.2
  • 43
    • 0022442863 scopus 로고
    • Fiber composition of the rat sciatic nerve
    • Schmalbruch H 1986 Fiber composition of the rat sciatic nerve Anat. Rec. 215 71-81 (Pubitemid 16051562)
    • (1986) Anatomical Record , vol.215 , Issue.1 , pp. 71-81
    • Schmalbruch, H.1
  • 47
    • 0025072993 scopus 로고
    • Aberrant reinnervation
    • Sumner A J 1990 Aberrant reinnervation Muscle Nerve 13 801-3
    • (1990) Muscle Nerve , vol.13 , pp. 801-803
    • Sumner, A.J.1
  • 49
    • 0036994474 scopus 로고    scopus 로고
    • Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
    • DOI 10.1109/TNSRE.2002.806840
    • Tyler D J and Durand D M 2002 Functionally selective peripheral nerve stimulation with a flat interface nerve electrode IEEE Trans. Neural. Syst. Rehabil. Eng. 10 294-303 (Pubitemid 36210939)
    • (2002) IEEE Transactions on Neural Systems and Rehabilitation Engineering , vol.10 , Issue.4 , pp. 294-303
    • Tyler, D.J.1    Durand, D.M.2
  • 50
    • 0036089743 scopus 로고    scopus 로고
    • Changes in crossed spinal reflexes after peripheral nerve injury and repair
    • Valero-Cabre A and Navarro X 2002a Changes in crossed spinal reflexes after peripheral nerve injury and repair J. Neurophysiol. 87 1763-71 (Pubitemid 34670742)
    • (2002) Journal of Neurophysiology , vol.87 , Issue.4 , pp. 1763-1771
    • Valero-Cabre, A.1    Navarro, X.2
  • 51
    • 0036859646 scopus 로고    scopus 로고
    • Functional impact of axonal misdirection after peripheral nerve injuries followed by graft or tube repair
    • Valero-Cabre A and Navarro X 2002b Functional impact of axonal misdirection after peripheral nerve injuries followed by graft or tube repair J. Neurotrauma 19 1475-85 (Pubitemid 35403676)
    • (2002) Journal of Neurotrauma , vol.19 , Issue.11 , pp. 1475-1485
    • Valero-Cabre, A.1    Navarro, X.2
  • 52
    • 0027717896 scopus 로고
    • Selective control of muscle activation with a multipolar nerve cuff electrode
    • DOI 10.1109/10.237694
    • Veraart C, Grill W M and Mortimer J T 1993 Selective control of muscle activation with a multipolar nerve cuff electrode IEEE Trans. Biomed. Eng. 40 640-53 (Pubitemid 24065539)
    • (1993) IEEE Transactions on Biomedical Engineering , vol.40 , Issue.7 , pp. 640-653
    • Veraart, C.1    Grill, W.M.2    Mortimer, J.T.3
  • 56
    • 0027070530 scopus 로고
    • The influence of bacterial collagenase on regeneration of severed rat sciatic nerves
    • DOI 10.1007/BF01541795
    • Wehling P, Pak M, Cleveland S and Nieper R 1992 The influence of bacterial collagenase on regeneration of severed rat sciatic nerves Acta Neurochir. (Wien) 119 121-7 (Pubitemid 23022781)
    • (1992) Acta Neurochirurgica , vol.119 , Issue.1-4 , pp. 121-127
    • Wehling, P.1    Pak, M.2    Cleveland, S.3    Nieper, R.4
  • 57
    • 77949424991 scopus 로고    scopus 로고
    • In vitro verification of a 3-D regenerative neural interface design: Examination of neurite growth and electrical properties within a bifurcating microchannel structure
    • Wieringa P A, Wiertz R W F, De Weerd E L and Rutten W L C 2010 In vitro verification of a 3-D regenerative neural interface design: examination of neurite growth and electrical properties within a bifurcating microchannel structure Proc. IEEE 98 389-97
    • (2010) Proc. IEEE , vol.98 , pp. 389-397
    • Wieringa, P.A.1    Wiertz, R.W.F.2    De Weerd, E.L.3    Rutten, W.L.C.4
  • 58
    • 0034001248 scopus 로고    scopus 로고
    • Intrafascicular electrodes for stimulation and recording from mudpuppy spinal roots
    • DOI 10.1016/S0165-0270(99)00176-4, PII S0165027099001764
    • Yoshida K, Jovanovic K and Stein R B 2000 Intrafascicular electrodes for stimulation and recording from mudpuppy spinal roots J. Neurosci. Methods 96 47-55 (Pubitemid 30125863)
    • (2000) Journal of Neuroscience Methods , vol.96 , Issue.1 , pp. 47-55
    • Yoshida, K.1    Jovanovic, K.2    Stein, R.B.3
  • 61
    • 41449089784 scopus 로고    scopus 로고
    • Recording and stimulating properties of chronically implanted longitudinal intrafascicular electrodes in peripheral fascicles in an animal model
    • DOI 10.1002/micr.20465
    • Zheng X, Zhang J, Chen T and Chen Z 2008 Recording and stimulating properties of chronically implanted longitudinal intrafascicular electrodes in peripheral fascicles in an animal model Microsurgery 28 203-9 (Pubitemid 351458271)
    • (2008) Microsurgery , vol.28 , Issue.3 , pp. 203-209
    • Zheng, X.1    Zhang, J.2    Chen, T.3    Chen, Z.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.