메뉴 건너뛰기




Volumn 45, Issue 4, 2012, Pages 719-723

The influence of acetabular cup material on pelvis cortex surface strains, measured using digital image correlation

Author keywords

Bone strain measurement; Hip replacement; Implant biomaterials; Stress shielding

Indexed keywords

ACETABULAR CUP; ADVANCED POLYMER COMPOSITE MATERIALS; BONE ADAPTATION; BONE MINERAL DENSITY; BONE QUALITY; BONE RESORPTION; BONE RESPONSE; CANCELLOUS BONE; CLINICAL OBSERVATION; COMPUTATIONAL STUDIES; CORTICAL BONE; DIGITAL IMAGE CORRELATIONS; EXPERIMENTAL EVIDENCE; HIP REPLACEMENT; IMPLANT DESIGN; LOAD PATHS; MATERIALS SELECTION; PRINCIPAL STRAIN; STRESS SHIELDING; SURFACE STRAINS; TOTAL HIP REPLACEMENTS;

EID: 84856738607     PISSN: 00219290     EISSN: 18732380     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2011.11.042     Document Type: Article
Times cited : (49)

References (28)
  • 1
    • 84856708691 scopus 로고    scopus 로고
    • Australian Orthopaedic Association National Joint Replacement Registry Annual Report. AOA: Adelaide.
    • Australian Orthopaedic Association National Joint Replacement Registry Annual Report. 2009, AOA: Adelaide.
    • (2009)
  • 4
    • 79951738960 scopus 로고    scopus 로고
    • Experimental validation of a finite element analysis model of the proximal femur using digital image correlation and a composite bone model
    • Dickinson A.S., Taylor A.C., Ozturk H., Browne M. Experimental validation of a finite element analysis model of the proximal femur using digital image correlation and a composite bone model. Journal of Biomechanical Engineering 2011, 133.
    • (2011) Journal of Biomechanical Engineering , pp. 133
    • Dickinson, A.S.1    Taylor, A.C.2    Ozturk, H.3    Browne, M.4
  • 5
    • 0026604141 scopus 로고
    • The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
    • Huiskes R., Weinans M.S., van Rietbergen M.S. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clinical Orthopaedics and Related Research 1992, 274:124-134.
    • (1992) Clinical Orthopaedics and Related Research , vol.274 , pp. 124-134
    • Huiskes, R.1    Weinans, M.S.2    van Rietbergen, M.S.3
  • 6
    • 34248351925 scopus 로고    scopus 로고
    • Bone remodelling around HA-coated acetabular cups: a DEXA study with a 3-year follow-up in a randomised trial
    • Laursen M.B., Nielsel P.T., Søballe K. Bone remodelling around HA-coated acetabular cups: a DEXA study with a 3-year follow-up in a randomised trial. International Orthopaedics 2007, 31:199-204.
    • (2007) International Orthopaedics , vol.31 , pp. 199-204
    • Laursen, M.B.1    Nielsel, P.T.2    Søballe, K.3
  • 7
    • 0021359644 scopus 로고
    • The influence of prosthetic stem stiffness and of a calcar collar on stresses in the proximal end of the femur with a cemented femoral component
    • Lewis J.L., Askew M.J., Wixson R.L., Kramer G.M., Tarr R.R. The influence of prosthetic stem stiffness and of a calcar collar on stresses in the proximal end of the femur with a cemented femoral component. Journal of Bone and Joint Surgery 1984, 66-A:280-286.
    • (1984) Journal of Bone and Joint Surgery , pp. 280-286
    • Lewis, J.L.1    Askew, M.J.2    Wixson, R.L.3    Kramer, G.M.4    Tarr, R.R.5
  • 8
    • 59449101105 scopus 로고    scopus 로고
    • Modes of periacetabular load transfer to cortical and cancellous bone after cemented versus uncemented total hip arthroplasty: a prospective study using computed tomography-assisted osteodensitometry
    • Mueller L.A., Schmidt R., Ehrmann C., Eckhard Nowak T., Kress A., Forst R., Pfander D. Modes of periacetabular load transfer to cortical and cancellous bone after cemented versus uncemented total hip arthroplasty: a prospective study using computed tomography-assisted osteodensitometry. Journal of Orthopaedic Research 2009, 27:176-182.
    • (2009) Journal of Orthopaedic Research , vol.27 , pp. 176-182
    • Mueller, L.A.1    Schmidt, R.2    Ehrmann, C.3    Eckhard Nowak, T.4    Kress, A.5    Forst, R.6    Pfander, D.7
  • 11
    • 84856724841 scopus 로고    scopus 로고
    • MatWeb Website,. Material property data. [October].
    • MatWeb Website,. Material property data. [October 2011]. http://www.matweb.com.
    • (2011)
  • 12
    • 84856724836 scopus 로고    scopus 로고
    • National Joint Registry for England and Wales 5th Annual Report. : Hemel Hempstead.
    • National Joint Registry for England and Wales 5th Annual Report. 2008: Hemel Hempstead.
    • (2008)
  • 15
    • 0022465758 scopus 로고
    • Observations on the effect of movement on bone ingrowth into porous-surfaced implants
    • Pilliar R.M., Lee J.M., Maniatopoulos C.D.D.S. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clinical Orthopaedics 1986, 208:108-113.
    • (1986) Clinical Orthopaedics , vol.208 , pp. 108-113
    • Pilliar, R.M.1    Lee, J.M.2    Maniatopoulos, C.D.D.S.3
  • 16
    • 0031951253 scopus 로고    scopus 로고
    • Periprosthetic mineralization around cementless total hip endoprosthesis: longitudinal study and cross-sectional study on titanium threaded acetabular cup and cementless spotorno stem with DEXA
    • Sabo D., Reiter A., Simank H.G., Thomsen M., Lukoschek M., Ewerbeck V. Periprosthetic mineralization around cementless total hip endoprosthesis: longitudinal study and cross-sectional study on titanium threaded acetabular cup and cementless spotorno stem with DEXA. Calcified Tissue International 1998, 62:177-182.
    • (1998) Calcified Tissue International , vol.62 , pp. 177-182
    • Sabo, D.1    Reiter, A.2    Simank, H.G.3    Thomsen, M.4    Lukoschek, M.5    Ewerbeck, V.6
  • 17
    • 84856760989 scopus 로고    scopus 로고
    • Is early bone resorption around non-cemented THA cups related to stress shielding?
    • in: 50th Annual Meeting of the Orthopaedic Research Society. San Francisco.
    • Stolk, J., Dormans, K.W., Sluimer, J., van Rietbergen, B., Geesink, R.G., Huiskes, R. Is early bone resorption around non-cemented THA cups related to stress shielding? in: 50th Annual Meeting of the Orthopaedic Research Society. 2004. San Francisco.
    • (2004)
    • Stolk, J.1    Dormans, K.W.2    Sluimer, J.3    Van Rietbergen, B.4    Geesink, R.G.5    Huiskes, R.6
  • 18
    • 77952490622 scopus 로고    scopus 로고
    • Using digital image correlation to determine bone surface strains during loading and after adaptation of the mouse tibia
    • Sztefek P., Vanleene M., Olsson R., Collinson R., Pitsillides A.A., Shefelbine S. Using digital image correlation to determine bone surface strains during loading and after adaptation of the mouse tibia. Journal of Biomechanics 2010, 43:599-605.
    • (2010) Journal of Biomechanics , vol.43 , pp. 599-605
    • Sztefek, P.1    Vanleene, M.2    Olsson, R.3    Collinson, R.4    Pitsillides, A.A.5    Shefelbine, S.6
  • 19
    • 0030623595 scopus 로고    scopus 로고
    • A technique for measuring the compressive modulus of articular cartilage under physiological loading rates with preliminary results
    • Shepherd D.E.T., Seedhorn B.B. A technique for measuring the compressive modulus of articular cartilage under physiological loading rates with preliminary results. Proceedings of the IMechE, Part H: Journal of Engineering in Medicine 1997, 211:155-165.
    • (1997) Proceedings of the IMechE, Part H: Journal of Engineering in Medicine , vol.211 , pp. 155-165
    • Shepherd, D.E.T.1    Seedhorn, B.B.2
  • 20
    • 0032990771 scopus 로고    scopus 로고
    • Thickness of human articular cartilage in joints of the lower limb
    • Shepherd D.E.T., Seedhorn B.B. Thickness of human articular cartilage in joints of the lower limb. Annals of the Rheumatic Diseases 1999, 58:27-34.
    • (1999) Annals of the Rheumatic Diseases , vol.58 , pp. 27-34
    • Shepherd, D.E.T.1    Seedhorn, B.B.2
  • 21
    • 0027381478 scopus 로고
    • Hydroxyapatite ceramic coating for bone-implant fixation. Mechanical and histological studies in dogs
    • Søballe K. Hydroxyapatite ceramic coating for bone-implant fixation. Mechanical and histological studies in dogs. Acta Orthopaedica Scandinavica 1993, 65(S255):1-58.
    • (1993) Acta Orthopaedica Scandinavica , vol.65 , Issue.S255 , pp. 1-58
    • Søballe, K.1
  • 22
    • 49849104468 scopus 로고    scopus 로고
    • Design considerations and life prediction of metal-on-metal bearings: the effect of clearance
    • Tuke M.A., Scott G., Roques A., Hu X.Q., Taylor A.C. Design considerations and life prediction of metal-on-metal bearings: the effect of clearance. Journal of Bone and Joint Surgery 2008, 90:134-141.
    • (2008) Journal of Bone and Joint Surgery , vol.90 , pp. 134-141
    • Tuke, M.A.1    Scott, G.2    Roques, A.3    Hu, X.Q.4    Taylor, A.C.5
  • 23
    • 0036048713 scopus 로고    scopus 로고
    • Effects of acetabular resurfacing component material and fixation on the strain distribution in the pelvis
    • Thompson M.S., Northmore-Ball M.D., Tanner K.E. Effects of acetabular resurfacing component material and fixation on the strain distribution in the pelvis. Proceedings of the IMechE 2002, 216:237-245.
    • (2002) Proceedings of the IMechE , vol.216 , pp. 237-245
    • Thompson, M.S.1    Northmore-Ball, M.D.2    Tanner, K.E.3
  • 24
    • 34247546030 scopus 로고    scopus 로고
    • Digital image correlation: a technique for determining local mechanical conditions within early bone callus
    • Thompson M.S., Schell H., Lienau J., Duda G.N. Digital image correlation: a technique for determining local mechanical conditions within early bone callus. Medical Engineering and Physics 2007, 29:820-823.
    • (2007) Medical Engineering and Physics , vol.29 , pp. 820-823
    • Thompson, M.S.1    Schell, H.2    Lienau, J.3    Duda, G.N.4
  • 25
    • 85047691712 scopus 로고    scopus 로고
    • Finite element analysis of the resurfaced femoral head
    • Taylor M. Finite element analysis of the resurfaced femoral head. Proceedings of the IMechE H 2006, 220:289-297.
    • (2006) Proceedings of the IMechE H , vol.220 , pp. 289-297
    • Taylor, M.1
  • 26
    • 77955361755 scopus 로고    scopus 로고
    • Mapping the strain distribution on the proximal femur with titanium flexible-stemmed implants using digital image correlation
    • Tayton E., Evans S., O'Doherty D. Mapping the strain distribution on the proximal femur with titanium flexible-stemmed implants using digital image correlation. J Bone Joint Surg. [Br.] 2010, 92B:1176-1181.
    • (2010) J Bone Joint Surg. [Br.] , vol.92 B , pp. 1176-1181
    • Tayton, E.1    Evans, S.2    O'Doherty, D.3
  • 28
    • 0036787773 scopus 로고    scopus 로고
    • Load transfer and fixation mode of press-fit acetabular sockets
    • Widmer K.-H., Zurfluh B., Morscher E.W. Load transfer and fixation mode of press-fit acetabular sockets. Journal of Arthroplasty 2002, 17:926-935.
    • (2002) Journal of Arthroplasty , vol.17 , pp. 926-935
    • Widmer, K.-H.1    Zurfluh, B.2    Morscher, E.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.