메뉴 건너뛰기




Volumn 17, Issue 7, 2002, Pages 926-935

Load transfer and fixation mode of press-fit acetabular sockets

Author keywords

3 point support; Contact area; Peripheral load transfer; Physiologic load transmission; Press fit fixation

Indexed keywords

ACETABULUM; AGED; ARTICLE; BONE REGENERATION; CONTROLLED STUDY; ENDOPROSTHESIS LOOSENING; FEMALE; FORCE; HUMAN; HUMAN TISSUE; ILIAC BONE; IMAGE ANALYSIS; ISCHIUM; MALE; PROSTHESIS FIXATION; PUBIC BONE; TOTAL HIP PROSTHESIS; WEIGHT BEARING;

EID: 0036787773     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1054/arth.2002.34526     Document Type: Article
Times cited : (92)

References (40)
  • 1
    • 0028047426 scopus 로고
    • Osteolysis around uncemented acetabular components of cobalt-chrome surface replacement hip arthroplasty
    • Buechel FF, Drucker D, Jasty M, et al: Osteolysis around uncemented acetabular components of cobalt-chrome surface replacement hip arthroplasty. Clin Orthop 298:202, 1994
    • (1994) Clin Orthop , vol.298 , pp. 202
    • Buechel, F.F.1    Drucker, D.2    Jasty, M.3
  • 2
    • 0024800260 scopus 로고
    • Charnley total hip arthroplasty with cement: Fifteen year results
    • Kavanagh BF, Dewitz MA, Ilstrup DM, et al: Charnley total hip arthroplasty with cement: fifteen year results. J Bone Joint Surg Am 71:1496, 1989
    • (1989) J Bone Joint Surg Am , vol.71 , pp. 1496
    • Kavanagh, B.F.1    Dewitz, M.A.2    Ilstrup, D.M.3
  • 3
    • 0029942735 scopus 로고    scopus 로고
    • The Nicolas Andry Award. Comparative results of cemented and cementless total hip arthroplasty
    • Rorabeck CH, Bourne RB, Mulliken BD, et al: The Nicolas Andry Award. Comparative results of cemented and cementless total hip arthroplasty. Clin Orthop 325:330, 1996
    • (1996) Clin Orthop , vol.325 , pp. 330
    • Rorabeck, C.H.1    Bourne, R.B.2    Mulliken, B.D.3
  • 4
    • 0033029624 scopus 로고    scopus 로고
    • Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty
    • Sochart DH: Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop 363:135, 1999
    • (1999) Clin Orthop , vol.363 , pp. 135
    • Sochart, D.H.1
  • 5
    • 0030880257 scopus 로고    scopus 로고
    • Number of polyethylene particles and osteolysis in total joint replacements
    • Kobayashi A, Freemann MAR, Bonfield W, et al: Number of polyethylene particles and osteolysis in total joint replacements. Bone Joint Surg Br 79:844, 1997
    • (1997) Bone Joint Surg Br , vol.79 , pp. 844
    • Kobayashi, A.1    Freemann, M.A.R.2    Bonfield, W.3
  • 6
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J, Ilstrup D, Morrey B: Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 72:518, 1990
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 518
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 7
    • 0031943675 scopus 로고    scopus 로고
    • Polyethylene wear and periprosthetic osteolysis in metal-backed acetabular components with cylindrical liners
    • Perez RE, Rodriguez JA, Deshmukh RG, Ranawat CS: Polyethylene wear and periprosthetic osteolysis in metal-backed acetabular components with cylindrical liners. J Arthroplasty 13:1, 1998
    • (1998) J Arthroplasty , vol.13 , pp. 1
    • Perez, R.E.1    Rodriguez, J.A.2    Deshmukh, R.G.3    Ranawat, C.S.4
  • 8
    • 0033965755 scopus 로고    scopus 로고
    • Acute periprosthetic fracture of the acetabulum associated with osteolytic pelvic lesions
    • Sanchez-Sotelo J, McGrory BJ, Berry DJ: Acute periprosthetic fracture of the acetabulum associated with osteolytic pelvic lesions. J Arthroplasty 15:126, 2000
    • (2000) J Arthroplasty , vol.15 , pp. 126
    • Sanchez-Sotelo, J.1    McGrory, B.J.2    Berry, D.J.3
  • 10
    • 0025222261 scopus 로고
    • Osteolysis in alloarthroplasty of the hip - The role of UHMW-polyethylene wear
    • Willert HG, Bertram H, Buchhorn GH: Osteolysis in alloarthroplasty of the hip - the role of UHMW-polyethylene wear. Clin Orthop 258:95, 1990
    • (1990) Clin Orthop , vol.258 , pp. 95
    • Willert, H.G.1    Bertram, H.2    Buchhorn, G.H.3
  • 12
    • 0030845001 scopus 로고    scopus 로고
    • Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement
    • Bugbee WD, Culpepper WJ 2nd, Engh CA Jr, Engh CA Sr: Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement. J Bone Joint Surg Am 79:1007, 1997
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1007
    • Bugbee, W.D.1    Culpepper W.J. II2    Engh C.A., Jr.3    Engh C.A., Sr.4
  • 13
    • 0026560894 scopus 로고
    • Determinants of stress shielding: Design versus materials versus interface
    • Sumner DR, Galante JO: Determinants of stress shielding: design versus materials versus interface. Clin Orthop 274:202, 1992
    • (1992) Clin Orthop , vol.274 , pp. 202
    • Sumner, D.R.1    Galante, J.O.2
  • 14
    • 0026821443 scopus 로고
    • Experimental determination of friction characteristics at the trabecular bone porouscoated metal interface in cementless implants
    • Shirazi-Adl A: Experimental determination of friction characteristics at the trabecular bone porouscoated metal interface in cementless implants. J Biomed Mater Res 27:167, 1993
    • (1993) J Biomed Mater Res , vol.27 , pp. 167
    • Shirazi-Adl, A.1
  • 15
    • 0020068499 scopus 로고
    • A technique for measuring instantaneous in vitro contact stress distributions in articular joints
    • Brown TD, Shaw DT: A technique for measuring instantaneous in vitro contact stress distributions in articular joints. J Biomech 15:329, 1982
    • (1982) J Biomech , vol.15 , pp. 329
    • Brown, T.D.1    Shaw, D.T.2
  • 16
    • 0032838156 scopus 로고    scopus 로고
    • Quantitative determination of joint incongruity and pressure distribution during simulated gait and cartilage thickness in the human hip joint
    • Eisenhart-Rothe R, Adam C, Steinlechner M, et al: Quantitative determination of joint incongruity and pressure distribution during simulated gait and cartilage thickness in the human hip joint. J Orthop Res 17:532, 1999
    • (1999) J Orthop Res , vol.17 , pp. 532
    • Eisenhart-Rothe, R.1    Adam, C.2    Steinlechner, M.3
  • 18
    • 0028153815 scopus 로고
    • Areas of contact and extent of gaps with implantation of oversized acetabular components in total hip arthroplasty
    • MacKenzie JR, Callaghan JJ, Pedersen DR, Brown TD: Areas of contact and extent of gaps with implantation of oversized acetabular components in total hip arthroplasty. Clin Orthop 298:127, 1994
    • (1994) Clin Orthop , vol.298 , pp. 127
    • MacKenzie, J.R.1    Callaghan, J.J.2    Pedersen, D.R.3    Brown, T.D.4
  • 19
    • 0021362007 scopus 로고
    • Contact study of the hip joint: Load-deformation pattern, contact area and contact pressure
    • Miyanaga Y, Fukubayashi T, Kurosawa H: Contact study of the hip joint: Load-deformation pattern, contact area and contact pressure. Arch Orthop Trauma Surg 103:13, 1984
    • (1984) Arch Orthop Trauma Surg , vol.103 , pp. 13
    • Miyanaga, Y.1    Fukubayashi, T.2    Kurosawa, H.3
  • 20
    • 0027264739 scopus 로고
    • Evaluation of initial surface apposition in porous-coated acetabular components
    • Schwartz JT, Engh CA, Forte MR, et al: Evaluation of initial surface apposition in porous-coated acetabular components. Clin Orthop 293:174, 1993
    • (1993) Clin Orthop , vol.293 , pp. 174
    • Schwartz, J.T.1    Engh, C.A.2    Forte, M.R.3
  • 21
    • 0027715365 scopus 로고
    • Failed innovation in total hip replacement: Diagnosis and proposals for a cure
    • Huiskes R: Failed innovation in total hip replacement: Diagnosis and proposals for a cure. Acta Orthop Scand 64:699, 1993
    • (1993) Acta Orthop Scand , vol.64 , pp. 699
    • Huiskes, R.1
  • 22
    • 0028943725 scopus 로고
    • Ligamentous contributions to pelvic stability
    • Vrahas MS, Hern TC, DiAngelo D, et al: Ligamentous contributions to pelvic stability. Orthopedics 18:271, 1995
    • (1995) Orthopedics , vol.18 , pp. 271
    • Vrahas, M.S.1    Hern, T.C.2    DiAngelo, D.3
  • 23
    • 0021647838 scopus 로고
    • Untersuchungen zur eichung der druckmessfolie in der biomechanik
    • Hendrich V, Widmer KH, Ficker E: Untersuchungen zur Eichung der Druckmessfolie in der Biomechanik. Unfallchirurg 10:278, 1984
    • (1984) Unfallchirurg , vol.10 , pp. 278
    • Hendrich, V.1    Widmer, K.H.2    Ficker, E.3
  • 24
    • 0027642032 scopus 로고
    • An algorithm for approximate crinkle artifact compensation in pressure-sensitive film recordings
    • Caldwell NJ, Hale JE, Rudert MJ, Brown TD: An algorithm for approximate crinkle artifact compensation in pressure-sensitive film recordings. J Biomech 26:1001, 1993
    • (1993) J Biomech , vol.26 , pp. 1001
    • Caldwell, N.J.1    Hale, J.E.2    Rudert, M.J.3    Brown, T.D.4
  • 26
    • 0001551828 scopus 로고
    • Osseointegration of Sulmesh coatings
    • Morscher EW (ed). Springer-Verlag, Berlin
    • Schenk R: Osseointegration of Sulmesh coatings. In Morscher EW (ed): Endoprosthetics. Springer-Verlag, Berlin, 1995
    • (1995) Endoprosthetics
    • Schenk, R.1
  • 27
    • 0026581886 scopus 로고
    • Das zeitliche verhalten der verankerung einer zementfrei implantierten hueftpfanne im tierversuch
    • Bereiter H, Buergi M, Rahn BA: Das zeitliche Verhalten der Verankerung einer zementfrei implantierten Hueftpfanne im Tierversuch. Orthopaede 21:63, 1992
    • (1992) Orthopaede , vol.21 , pp. 63
    • Bereiter, H.1    Buergi, M.2    Rahn, B.A.3
  • 28
    • 0030983684 scopus 로고    scopus 로고
    • Contact area and pressure load at the implant/bone interface of press-fit cups compared with the natural hip joints
    • Widmer KH, Zurfluh B, Morscher EW: Contact area and pressure load at the implant/bone interface of press-fit cups compared with the natural hip joints. Orthopaede 26:181, 1997
    • (1997) Orthopaede , vol.26 , pp. 181
    • Widmer, K.H.1    Zurfluh, B.2    Morscher, E.W.3
  • 29
    • 0031707431 scopus 로고    scopus 로고
    • Intermediate clinical follow-up of a dual-radius acetabular component
    • van Flandern GJ, Bierbaum BE, Newberg AH, et al: Intermediate clinical follow-up of a dual-radius acetabular component. J Arthroplasty 13:804, 1998
    • (1998) J Arthroplasty , vol.13 , pp. 804
    • Van Flandern, G.J.1    Bierbaum, B.E.2    Newberg, A.H.3
  • 30
    • 0028849176 scopus 로고
    • Cementless total hip arthroplasty in patients with osteonecrosis of the femoral head
    • Kim Y, Oh J, Oh S: Cementless total hip arthroplasty in patients with osteonecrosis of the femoral head. Clin Orthop 320:73, 1995
    • (1995) Clin Orthop , vol.320 , pp. 73
    • Kim, Y.1    Oh, J.2    Oh, S.3
  • 31
    • 0032848288 scopus 로고    scopus 로고
    • The influence of friction and interference on the seating of a hemispherical press-fit cup: A finite element investigation
    • Spears IR, Morlock MM, Pfleiderer M, et al: The influence of friction and interference on the seating of a hemispherical press-fit cup: a finite element investigation. J Biomech 32:1183, 1999
    • (1999) J Biomech , vol.32 , pp. 1183
    • Spears, I.R.1    Morlock, M.M.2    Pfleiderer, M.3
  • 32
    • 0032762859 scopus 로고    scopus 로고
    • Photoelastic analysis of stresses produced by different acetabular cups
    • Ries MD, Salehi AS, Shea J: Photoelastic analysis of stresses produced by different acetabular cups. Clin Orthop 369:165, 1999
    • (1999) Clin Orthop , vol.369 , pp. 165
    • Ries, M.D.1    Salehi, A.S.2    Shea, J.3
  • 33
    • 0026676824 scopus 로고
    • Stabilisationsverfahren in der halswirbelsaeulentraumatologie: Implantate und biomechanik
    • Morscher EW: Stabilisationsverfahren in der Halswirbelsaeulentraumatologie: Implantate und Biomechanik. Z Orthop 130:441, 1992
    • (1992) Z Orthop , vol.130 , pp. 441
    • Morscher, E.W.1
  • 34
    • 0017186669 scopus 로고
    • Mechanical function of subchondral bone as experimentally determined on the acetabulum of the human pelvis
    • Jacobs HAC, Huggler AH, Dietschi C, Schreiber A: Mechanical function of subchondral bone as experimentally determined on the acetabulum of the human pelvis. J Biomech 9:625, 1976
    • (1976) J Biomech , vol.9 , pp. 625
    • Jacobs, H.A.C.1    Huggler, A.H.2    Dietschi, C.3    Schreiber, A.4
  • 35
    • 0029310682 scopus 로고
    • Load transfer across the pelvic bone
    • Dalstra M, Huiskes R: Load transfer across the pelvic bone. J Biomech 28:715, 1995
    • (1995) J Biomech , vol.28 , pp. 715
    • Dalstra, M.1    Huiskes, R.2
  • 36
    • 0030841384 scopus 로고    scopus 로고
    • Rationale of a flexible press fit cup in total hip replacement: 5-Year follow-up in 280 procedures
    • Morscher EW, Berli B, Jockers W, Schenk R: Rationale of a flexible press fit cup in total hip replacement: 5-year follow-up in 280 procedures. Clin Orthop 341:42, 1997
    • (1997) Clin Orthop , vol.341 , pp. 42
    • Morscher, E.W.1    Berli, B.2    Jockers, W.3    Schenk, R.4
  • 38
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in two patients
    • Bergmann G, Graichen F, Rohlmann A: Hip joint loading during walking and running, measured in two patients. J Biomech 26:969, 1993
    • (1993) J Biomech , vol.26 , pp. 969
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 39
    • 0031240038 scopus 로고    scopus 로고
    • Pelvic muscle and acetabular contact forces during gait
    • Pedersen DR, Brand RA, Davy DT: Pelvic muscle and acetabular contact forces during gait. J Biomech 30:959, 1997
    • (1997) J Biomech , vol.30 , pp. 959
    • Pedersen, D.R.1    Brand, R.A.2    Davy, D.T.3
  • 40
    • 0024351308 scopus 로고
    • Contact pressures from an instrumented hip endoprosthesis
    • Hodge WA, Carlson KL, Fijan RS, et al: Contact pressures from an instrumented hip endoprosthesis. J Bone Joint Surg Am 71:1378, 1989
    • (1989) J Bone Joint Surg Am , vol.71 , pp. 1378
    • Hodge, W.A.1    Carlson, K.L.2    Fijan, R.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.