메뉴 건너뛰기




Volumn 83, Issue 4, 2001, Pages 529-536

Bone density adjacent to press-fit acetabular components: A prospective analysis with quantitative computed tomography

Author keywords

[No Author keywords available]

Indexed keywords

ACETABULUM; ARTICLE; BONE DENSITY; BONE MINERAL; BONE REMODELING; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER SIMULATION; FEMUR SHAFT; FINITE ELEMENT ANALYSIS; FOLLOW UP; HIP PROSTHESIS; HUMAN; IMPLANT; MEASUREMENT; OSTEOARTHRITIS; OSTEOLYSIS; PELVIC GIRDLE; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; TOTAL HIP PROSTHESIS;

EID: 0035071654     PISSN: 00219355     EISSN: None     Source Type: Journal    
DOI: 10.2106/00004623-200104000-00007     Document Type: Article
Times cited : (86)

References (61)
  • 16
    • 0023777583 scopus 로고
    • The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty
    • (1988) Clin Orthop , vol.231 , pp. 7-28
    • Engh, C.A.1    Bobyn, J.D.2
  • 22
    • 0027748808 scopus 로고
    • Stress shielding and bone resorption in THA: Clinical versus computer-simulation studies
    • (1993) Acta Orthop Belg , vol.59 , Issue.SUPPL. 1 , pp. 118-129
    • Huiskes, R.1
  • 24
    • 0027686380 scopus 로고
    • Effects of porous coating and collar support on early load transfer for a cementless hip prosthesis
    • (1993) J Biomech , vol.26 , pp. 1205-1216
    • Keaveny, T.M.1    Bartel, D.L.2
  • 30
    • 0026594543 scopus 로고
    • Will stress shielding limit the longevity of cemented femoral components of total hip replacement?
    • (1992) Clin Orthop , vol.274 , pp. 120-123
    • Harris, W.H.1
  • 32
    • 0023547272 scopus 로고
    • Finite element analysis of acetabular reconstruction. Noncemented threaded cups
    • (1987) Acta Orthop Scand , vol.58 , pp. 620-625
    • Huiskes, R.1
  • 47
    • 0020038663 scopus 로고
    • Stress distributions in the acetabular region - II. Effects of cement thickness and metal backing of the total hip acetabular component
    • (1982) J Biomech , vol.15 , pp. 165-170
    • Carter, D.R.1    Vasu, R.2    Harris, W.H.3
  • 54
    • 0026442786 scopus 로고
    • The Harris-Galante porous-coated acetabular component with screw fixation. Radiographic analysis of eighty-three primary hip replacements at a minimum of five years
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 1130-1139
    • Schmalzried, T.P.1    Harris, W.H.2
  • 57
    • 0026588287 scopus 로고
    • Current status of acetabular fixation in primary total hip arthroplasty
    • (1992) Clin Orthop , vol.274 , pp. 172-193
    • Morscher, E.W.1
  • 58
    • 0005407722 scopus 로고
    • Noncemented acetabular fixation in primary total hip replacement
    • Morscher EW, editor. New York: Springer
    • (1995) Endoprosthetics , pp. 143-179
    • Morscher, E.W.1
  • 61
    • 0000399759 scopus 로고    scopus 로고
    • Measurement of periprosthetic bone mineral density after cementless hip arthroplasty by dual-energy x-ray absorptiometry
    • (1996) J Orthop Sci , vol.1 , pp. 113-122
    • Nakamura, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.