메뉴 건너뛰기




Volumn 88, Issue 2, 2002, Pages 183-191

The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws

Author keywords

[No Author keywords available]

Indexed keywords

GOLD; GOLD ALLOY;

EID: 0036673514     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1067/mpr.2002.127604     Document Type: Article
Times cited : (72)

References (20)
  • 1
    • 0024031358 scopus 로고
    • Biomaterials and biomechanics in dental implant design
    • Brunski JB. Biomaterials and biomechanics in dental implant design. Int J Oral Maxillofac Implants 1988;3:85-97.
    • (1988) Int J Oral Maxillofac Implants , vol.3 , pp. 85-97
    • Brunski, J.B.1
  • 2
    • 0029261217 scopus 로고
    • Comparison of "look-alike" implant prosthetic retaining screws
    • Jaarda MJ, Razzoog ME, Gratton DG. Comparison of "look-alike" implant prosthetic retaining screws. J Prosthodont 1995;4:23-7.
    • (1995) J Prosthodont , vol.4 , pp. 23-27
    • Jaarda, M.J.1    Razzoog, M.E.2    Gratton, D.G.3
  • 3
    • 0028451094 scopus 로고
    • Tightening characteristics for screwed joints in osseointegrated dental implants
    • Burguete RL, Johns RB, King T, Patterson EA. Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosthet Dent 1994; 71:592-9.
    • (1994) J Prosthet Dent , vol.71 , pp. 592-599
    • Burguete, R.L.1    Johns, R.B.2    King, T.3    Patterson, E.A.4
  • 5
    • 0028391163 scopus 로고
    • Implant treatment in partially edentulous patients: A report on prostheses after 3 years
    • Gunne J, Jemt T, Linden B. Implant treatment in partially edentulous patients: a report on prostheses after 3 years. Int J Prosthodont 1994;7: 143-8.
    • (1994) Int J Prosthodont , vol.7 , pp. 143-148
    • Gunne, J.1    Jemt, T.2    Linden, B.3
  • 6
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
    • Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1 994;9:169-78.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 7
    • 0028185281 scopus 로고
    • Osseointegrated implants for single-tooth replacement: Progress report from a multicenter prospective study after 3 years
    • Laney WR, Jemt T, Harris D, Henry PJ, Krogh PH, Polizzi G, et al. Osseointegrated implants for single-tooth replacement: progress report from a multicenter prospective study after 3 years. Int J Oral Maxillofac Implants 1994;9:49-54.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 49-54
    • Laney, W.R.1    Jemt, T.2    Harris, D.3    Henry, P.J.4    Krogh, P.H.5    Polizzi, G.6
  • 8
    • 0027793057 scopus 로고
    • Oral implant treatment in posterior partially edentulous jaws: A 5-year follow-up report
    • Jemt T, Lekholm U. Oral implant treatment in posterior partially edentulous jaws: a 5-year follow-up report. Int J Oral Maxillofac Implants 1993; 8:635-40.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 635-640
    • Jemt, T.1    Lekholm, U.2
  • 9
    • 0026832538 scopus 로고
    • Failures and complications in 127 consecutively placed fixed partial prostheses supported by Brånemark implants: From prosthetic treatment to first annual checkup
    • Jemt T, Linden B, Lekholm U. Failures and complications in 127 consecutively placed fixed partial prostheses supported by Brånemark implants: from prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants 1992;7:40-4.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 40-44
    • Jemt, T.1    Linden, B.2    Lekholm, U.3
  • 10
    • 0025471133 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered
    • Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: problems and complications encountered. J Prosthet Dent 1990;64:185-94.
    • (1990) J Prosthet Dent , vol.64 , pp. 185-194
    • Zarb, G.A.1    Schmitt, A.2
  • 11
    • 0024763839 scopus 로고
    • Complications with osseointegrated implants
    • Sones AD. Complications with osseointegrated implants. J Prosthet Dent 1989;62:581-5.
    • (1989) J Prosthet Dent , vol.62 , pp. 581-585
    • Sones, A.D.1
  • 12
    • 0026921977 scopus 로고
    • Loads and designs of screw joints for single crowns supported by osseointegrated implants
    • Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-9.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 353-359
    • Jorneus, L.1    Jemt, T.2    Carlsson, L.3
  • 13
    • 0027655334 scopus 로고
    • Torque required to loosen single-tooth implant abutment screws before and after simulated function
    • Breeding LC, Dixon DL, Nelson EW, Tietge JD. Torque required to loosen single-tooth implant abutment screws before and after simulated function. Int J Prosthodont 1993;6:435-9.
    • (1993) Int J Prosthodont , vol.6 , pp. 435-439
    • Breeding, L.C.1    Dixon, D.L.2    Nelson, E.W.3    Tietge, J.D.4
  • 14
    • 0026829920 scopus 로고
    • Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants
    • Patterson EA, Johns RB. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants 1992;7:26-33.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 26-33
    • Patterson, E.A.1    Johns, R.B.2
  • 16
    • 0029366883 scopus 로고
    • A comparison of implant/prosthesis loading with four clinical variables
    • Weinberg LA, Kruger B. A comparison of implant/prosthesis loading with four clinical variables. Int J Prosthodont 1995;8:421-33.
    • (1995) Int J Prosthodont , vol.8 , pp. 421-433
    • Weinberg, L.A.1    Kruger, B.2
  • 17
    • 0028394160 scopus 로고
    • Effect of preload torque on the ultimate tensile strength of implant prosthetic retaining screws
    • Jaarda MJ, Razzoog ME, Gratton DG. Effect of preload torque on the ultimate tensile strength of implant prosthetic retaining screws. Implant Dent 1994;3:17-21.
    • (1994) Implant Dent , vol.3 , pp. 17-21
    • Jaarda, M.J.1    Razzoog, M.E.2    Gratton, D.G.3
  • 18
    • 0029302999 scopus 로고
    • Nonlinear contact analysis of preload in dental implant screws
    • Sakaguchi RL, Borgersen SE. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants 1995;10:295-302.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 295-302
    • Sakaguchi, R.L.1    Borgersen, S.E.2
  • 19
    • 0028389987 scopus 로고
    • Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants
    • Goheen KL, Vermilyea SG, Vossoughi J, Agar JR. Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants. Int J Oral Maxillofac Implants 1994;9:149-55.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 149-155
    • Goheen, K.L.1    Vermilyea, S.G.2    Vossoughi, J.3    Agar, J.R.4
  • 20
    • 0027828236 scopus 로고
    • A measurement of torque values obtained with hand-held drivers in a simulated clinical setting
    • Dellinges MA, Tebrock OC. A measurement of torque values obtained with hand-held drivers in a simulated clinical setting. J Prosthodont 1993; 2:212-4.
    • (1993) J Prosthodont , vol.2 , pp. 212-214
    • Dellinges, M.A.1    Tebrock, O.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.