메뉴 건너뛰기




Volumn 26, Issue 4, 2011, Pages 707-717

Reference-based digital concept to restore partially edentulous patients following an immediate loading protocol: A pilot study

Author keywords

Dental implants; Guided surgery; Immediate loading

Indexed keywords

ADULT; ARTICLE; COMPUTER AIDED DESIGN; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; DENTAL PROCEDURE; EDENTULOUSNESS; FIDUCIAL MARKER; HUMAN; INSTRUMENTATION; METHODOLOGY; MIDDLE AGED; PATIENT CARE PLANNING; PILOT STUDY; PROSTHESIS; RADIOGRAPHY; THREE DIMENSIONAL IMAGING; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 84555170326     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (17)
  • 1
    • 0025583364 scopus 로고
    • Jemt T. Longterm follow-up study of osseointegrated implants in the treatment of totally edentulous jaws
    • Adell R, Eriksson B, Lekholm U, Brånemark PI. Jemt T. Longterm follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 1990;5:347-359.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 347-359
    • Adell, R.1    Eriksson, B.2    Lekholm, U.3    Brånemark, P.I.4
  • 2
    • 20744446711 scopus 로고    scopus 로고
    • A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: A prospective multicenter study
    • van Steenberghe D, Glauser R, Blombäck U, et al. A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: A prospective multicenter study. Clin Implant Dent Relat Res 2005;7(suppl 1):111-120.
    • (2005) Clin Implant Dent Relat Res , vol.7 , pp. 111-120
    • van Steenberghe, D.1    Glauser, R.2    Blombäck, U.3
  • 3
    • 0037946955 scopus 로고    scopus 로고
    • Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers
    • van Steenberghe D, Malevez C, van Cleynenbreugel J, et al. Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers. Clin Oral Implants Res 2003;14:131-136.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 131-136
    • van Steenberghe, D.1    Malevez, C.2    van Cleynenbreugel, J.3
  • 5
    • 43049114556 scopus 로고    scopus 로고
    • The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: A critical review on accuracy
    • Vercruyssen M, Jacobs R, van Assche N, van Steerberghe D. The use of CT scan based planning for oral rehabilitation by means of implants and its transfer to the surgical field: A critical review on accuracy. J Oral Rehabil 2008;35:454-474.
    • (2008) J Oral Rehabil , vol.35 , pp. 454-474
    • Vercruyssen, M.1    Jacobs, R.2    van Assche, N.3    van Steerberghe, D.4
  • 6
    • 0035053536 scopus 로고    scopus 로고
    • Effect of scattered radiation on image noise in cone beam CT
    • Endo M, Tsunoo T, Nakamori N, Yoshida K. Effect of scattered radiation on image noise in cone beam CT. Med Phys 2001;28:469-474.
    • (2001) Med Phys , vol.28 , pp. 469-474
    • Endo, M.1    Tsunoo, T.2    Nakamori, N.3    Yoshida, K.4
  • 7
    • 0032240404 scopus 로고    scopus 로고
    • A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results
    • Mozzo P, Procacci C, Tacconi A, Martini PT, Andreais A. A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results. Eur Radiol 1998;8:1558-1564.
    • (1998) Eur Radiol , vol.8 , pp. 1558-1564
    • Mozzo, P.1    Procacci, C.2    Tacconi, A.3    Martini, P.T.4    Andreais, A.5
  • 8
    • 0017195533 scopus 로고
    • Beam hardening in reconstructive tomography
    • Brooks RA, DiChiro G. Beam hardening in reconstructive tomography. Phys Med Biol 1976;21:390-398.
    • (1976) Phys Med Biol , vol.21 , pp. 390-398
    • Brooks, R.A.1    DiChiro, G.2
  • 9
    • 0033983855 scopus 로고    scopus 로고
    • An iterative approach to the beam hardening correction in cone beam CT
    • Hsieh J, Molthen RC, Dawson CA, Johnson RH. An iterative approach to the beam hardening correction in cone beam CT. Med Phys 2000;27:23-29.
    • (2000) Med Phys , vol.27 , pp. 23-29
    • Hsieh, J.1    Molthen, R.C.2    Dawson, C.A.3    Johnson, R.H.4
  • 10
    • 40549094662 scopus 로고    scopus 로고
    • Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements
    • Loubele M, Van Assche AN, Carpentier K, et al. Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;105:512-518.
    • (2008) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.105 , pp. 512-518
    • Loubele, M.1    Van Assche, A.N.2    Carpentier, K.3
  • 11
    • 67649227108 scopus 로고    scopus 로고
    • Accuracy of threedimensional measurements obtained from cone beam computed tomography surface-rendered images for cephalometric analyses: Influence of patient scanning position
    • Hassan B, van der Stelt P, Sanderink G. Accuracy of threedimensional measurements obtained from cone beam computed tomography surface-rendered images for cephalometric analyses: Influence of patient scanning position. Eur J Orthod 2009;31:129-134.
    • (2009) Eur J Orthod , vol.31 , pp. 129-134
    • Hassan, B.1    van der Stelt, P.2    Sanderink, G.3
  • 12
    • 75549091560 scopus 로고    scopus 로고
    • Computer technology applications in surgical implant dentistry. A systematic review
    • Jung RE, Schneider D, Ganeles J, et al. Computer technology applications in surgical implant dentistry. A systematic review. Int J Oral Maxillofac Implants 2009;24(suppl):92-109.
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 92-109
    • Jung, R.E.1    Schneider, D.2    Ganeles, J.3
  • 13
    • 70349571892 scopus 로고    scopus 로고
    • Computer-guided implant placement: 3D planning software, fixed intraoral reference points and CAD/CAM technology, a new approach. A case report
    • Tahmaseb A, De Clerck R, Wismeijer D. Computer-guided implant placement: 3D planning software, fixed intraoral reference points and CAD/CAM technology, a new approach. A case report. Int J Oral Maxillofac Implants 2009;24:541-546.
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 541-546
    • Tahmaseb, A.1    De Clerck, R.2    Wismeijer, D.3
  • 14
    • 77953273784 scopus 로고    scopus 로고
    • Parameters of passive fit of a novel technique to mill implant supported superstructure. A novel 3-dimensional misfit-force measurement method in an in vitro study
    • Tahmaseb A, van de Weijden J, Mercelis P, De Clerck R, Wismeijer D. Parameters of passive fit of a novel technique to mill implant supported superstructure. A novel 3-dimensional misfit-force measurement method in an in vitro study. Int J Oral Maxillofac Implants 2010;25:247-257.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 247-257
    • Tahmaseb, A.1    van de Weijden, J.2    Mercelis, P.3    De Clerck, R.4    Wismeijer, D.5
  • 15
    • 0018507962 scopus 로고
    • Distortion in indexing method and investing media for soldering and remount procedures
    • Harper RJ, Nicholls JI. Distortion in indexing method and investing media for soldering and remount procedures. J Prosthet Dent 1979;42:172-179.
    • (1979) J Prosthet Dent , vol.42 , pp. 172-179
    • Harper, R.J.1    Nicholls, J.I.2
  • 16
    • 0017496465 scopus 로고
    • The measurement of distortion: Theoretical considerations
    • Nicholls JI. The measurement of distortion: Theoretical considerations. J Prosthet Dent 1977;37:578-586.
    • (1977) J Prosthet Dent , vol.37 , pp. 578-586
    • Nicholls, J.I.1
  • 17
    • 0017950083 scopus 로고
    • The measurement of distortion: Mathematical considerations
    • Nicholls JI. The measurement of distortion: Mathematical considerations. J Prosthet Dent 1978;39:339-343.
    • (1978) J Prosthet Dent , vol.39 , pp. 339-343
    • Nicholls, J.I.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.