메뉴 건너뛰기




Volumn 25, Issue 2, 2010, Pages 247-257

Parameters of passive fit using a new technique to mill implant-supported superstructures: An in vitro study of a novel three-dimensional force measurement-misfit method

Author keywords

Dental implants; Guided surgery; Misfit; Superstructure

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; CALCIUM SULFATE; TITANIUM;

EID: 77953273784     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (28)

References (20)
  • 1
    • 0036728374 scopus 로고    scopus 로고
    • Verification jig for implant-supported prostheses: A comparison of standard impressions with verification jigs made of different materials
    • De La Cruz JE, Funkenbusch PD, Ercoli C, Moss ME, Graser GN, Tallens RH. Verification jig for implant-supported prostheses: A comparison of standard impressions with verification jigs made of different materials. J Prosthet Dent 2002;88:329-336.
    • (2002) J Prosthet Dent , vol.88 , pp. 329-336
    • De La Cruz, J.E.1    Funkenbusch, P.D.2    Ercoli, C.3    Moss, M.E.4    Graser, G.N.5    Tallens, R.H.6
  • 2
    • 0033122309 scopus 로고    scopus 로고
    • Precision of CNC-milled titanium frameworks for implant treatment in the edentulous jaw
    • Jemt T, Bäck T, Petersson A. Precision of CNC-milled titanium frameworks for implant treatment in the edentulous jaw. Int J Prosthodont 1999;12:209-215.
    • (1999) Int J Prosthodont , vol.12 , pp. 209-215
    • Jemt, T.1    Bäck, T.2    Petersson, A.3
  • 4
    • 0034574921 scopus 로고    scopus 로고
    • Clinical experiences of CNC-milled titanium frameworks supported by implants in the edentulous jaw:1-year prospective study
    • Ortorp A, Jemt T. Clinical experiences of CNC-milled titanium frameworks supported by implants in the edentulous jaw:1-year prospective study. Clin Implant Dent Relat Res 2000;2:2-9.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 2-9
    • Ortorp, A.1    Jemt, T.2
  • 5
    • 0038488528 scopus 로고    scopus 로고
    • Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible
    • Ortorp A, Jemt T, Back T, Jalevik T. Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible. Int J Prosthodont 2003;16:194-200.
    • (2003) Int J Prosthodont , vol.16 , pp. 194-200
    • Ortorp, A.1    Jemt, T.2    Back, T.3    Jalevik, T.4
  • 7
    • 0041510493 scopus 로고    scopus 로고
    • Stereolithographic surgical templates for placement of dental implants in complex cases
    • Sarment DP, Al-Shammari K, Kazor CE. Stereolithographic surgical templates for placement of dental implants in complex cases. Int J Periodontics Restorative Dent 2003;23:287-295.
    • (2003) Int J Periodontics Restorative Dent , vol.23 , pp. 287-295
    • Sarment, D.P.1    Al-Shammari, K.2    Kazor, C.E.3
  • 8
    • 70349571892 scopus 로고    scopus 로고
    • Computer-guided implant placement: 3D planning software, fixed intraoral reference points and CAD/CAM technology. A case report
    • Tahmaseb A, De Clerck R, Wismeijer D. Computer-guided implant placement: 3D planning software, fixed intraoral reference points and CAD/CAM technology. A case report. Int J Oral Maxillofac Implants 2009;24:541-546.
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 541-546
    • Tahmaseb, A.1    De Clerck, R.2    Wismeijer, D.3
  • 11
    • 62349138332 scopus 로고    scopus 로고
    • Model and algorithms for point cloud construction using digital projection patterns
    • Peng T, Gupta SK. Model and algorithms for point cloud construction using digital projection patterns. ASME J Comput Inf Sci Eng 2007;7:372-381.
    • (2007) ASME J Comput Inf Sci Eng , vol.7 , pp. 372-381
    • Peng, T.1    Gupta, S.K.2
  • 12
    • 0018507962 scopus 로고
    • Distortions in indexing methods and investing media for soldering and remount procedures
    • Harper RJ, Nicholls JI. Distortions in indexing methods and investing media for soldering and remount procedures. J Prosthet Dent 1979;42:172-179.
    • (1979) J Prosthet Dent , vol.42 , pp. 172-179
    • Harper, R.J.1    Nicholls, J.I.2
  • 13
    • 0017496465 scopus 로고
    • The measurement of distortion: Theoretical considerations
    • Nicholls JI. The measurement of distortion: Theoretical considerations. J Prosthet Dent 1977;37:578-586.
    • (1977) J Prosthet Dent , vol.37 , pp. 578-586
    • Nicholls, J.I.1
  • 14
    • 0017950083 scopus 로고
    • The measurement of distortion: Mathematical considerations
    • Nicholls JI. The measurement of distortion: Mathematical considerations. J Prosthet Dent 1978;97:339-343.
    • (1978) J Prosthet Dent , vol.97 , pp. 339-343
    • Nicholls, J.I.1
  • 15
    • 0035053536 scopus 로고    scopus 로고
    • Effect of scattered radiation on image noise in cone beam CT
    • Endo M, Tsunoo T, Nakamori N, Yoshida K. Effect of scattered radiation on image noise in cone beam CT. Med Phys 2001;28:469-74.
    • (2001) Med Phys , vol.28 , pp. 469-474
    • Endo, M.1    Tsunoo, T.2    Nakamori, N.3    Yoshida, K.4
  • 16
    • 0032240404 scopus 로고    scopus 로고
    • A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results
    • Mozzo P, Procacci C, Tacconi A, Martini PT, Andreais A. A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results. Eur Radiol 1998;8:1558-1564.
    • (1998) Eur Radiol , vol.8 , pp. 1558-1564
    • Mozzo, P.1    Procacci, C.2    Tacconi, A.3    Martini, P.T.4    Andreais, A.5
  • 17
    • 0017195533 scopus 로고
    • Beam hardening in reconstructive tomography
    • Brooks RA, DiChiro G. Beam hardening in reconstructive tomography. Phys Med Biol 1976;21:390-398.
    • (1976) Phys Med Biol , vol.21 , pp. 390-398
    • Brooks, R.A.1    DiChiro, G.2
  • 18
    • 0033983855 scopus 로고    scopus 로고
    • An iterative approach to the beam hardening correction in cone beam CT
    • Hsieh J, Molthen RC, Dawson CA, Johnson RH. An iterative approach to the beam hardening correction in cone beam CT. Med Phys 2000;27:23-29.
    • (2000) Med Phys , vol.27 , pp. 23-29
    • Hsieh, J.1    Molthen, R.C.2    Dawson, C.A.3    Johnson, R.H.4
  • 19
    • 40549094662 scopus 로고    scopus 로고
    • Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements
    • Loubele M, Van Assche AN, Carpentier K, et al. Comparative localized linear accuracy of small-field cone-beam CT and multislice CT for alveolar bone measurements. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;105:512-518.
    • (2008) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.105 , pp. 512-518
    • Loubele, M.1    Van Assche, A.N.2    Carpentier, K.3
  • 20
    • 67649227108 scopus 로고    scopus 로고
    • Accuracy of threedimensional measurements obtained from cone-beam computed tomography surface-rendered images for cephalometric analyses: Influence of patient scanning position
    • Hassan B, van der Stelt P, Sanderink G. Accuracy of threedimensional measurements obtained from cone-beam computed tomography surface-rendered images for cephalometric analyses: Influence of patient scanning position. Eur J Orthod 2009;31:129-134.
    • (2009) Eur J Orthod , vol.31 , pp. 129-134
    • Hassan, B.1    van der Stelt, P.2    Sanderink, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.