메뉴 건너뛰기




Volumn 22, Issue 16, 2011, Pages 1811-1827

Semi-active vibration control of connected buildings using magnetorheological dampers

Author keywords

clipped optimal control; connected buildings; LQR; MR damper; recurrent neural network

Indexed keywords

ADJACENT BUILDINGS; BASE SHEAR; BOUC WEN MODEL; CONTROL FORCE; DAMPER FORCE; INPUT VOLTAGES; LQR; LQR CONTROL; LQR CONTROLLER; MAGNETO-RHEOLOGICAL DAMPERS; MR DAMPER; MR DAMPERS; NON-TRIVIAL TASKS; OPTIMAL CONTROLS; PEAK ACCELERATION; RE-DISTRIBUTION; SATURATION VOLTAGE; SEMI-ACTIVE; SEMI-ACTIVE VIBRATION CONTROL;

EID: 82955223450     PISSN: 1045389X     EISSN: 15308138     Source Type: Journal    
DOI: 10.1177/1045389X11412640     Document Type: Article
Times cited : (32)

References (21)
  • 1
    • 0036463023 scopus 로고    scopus 로고
    • Neural network emulation of inverse dynamics for a magnetorheological damper
    • DOI 10.1061/(ASCE)0733-9445(2002)128:2(231)
    • Chang CC, Zhou L. Neural network emulation of inverse dynamics for a magnetorheological damper. ASCE J Struct Eng. 2002 ; 128 (2). 231-239 (Pubitemid 35023057)
    • (2002) Journal of Structural Engineering , vol.128 , Issue.2 , pp. 231-239
    • Chang, C.-C.1    Zhou, L.2
  • 2
    • 33847124441 scopus 로고    scopus 로고
    • Semiactive connected control method for adjacent multidegree-of-freedom buildings
    • DOI 10.1061/(ASCE)0733-9399(2007)133:3(290)
    • Christenson RE, Spencer BF, Johnson EA. Semi-active connected control method for adjacent multidegree-of-freedom buildings. J Eng Mech. 2007 ; 133 (3). 290-298 (Pubitemid 46291395)
    • (2007) Journal of Engineering Mechanics , vol.133 , Issue.3 , pp. 290-298
    • Christenson, R.E.1    Spencer, B.F.2    Johnson, E.A.3
  • 4
    • 0030264561 scopus 로고    scopus 로고
    • Modeling and control of magnetorheological dampers for seismic response reduction
    • Dyke SJ, Spencer BF, Sain MK, Carlson JD. Modelling and control of magnetorheological dampers for seismic response reduction. Smart Mater Struct. 1996 ; 5 (5). 565-575 (Pubitemid 126649193)
    • (1996) Smart Materials and Structures , vol.5 , Issue.5 , pp. 565-575
    • Dyke, S.J.1    Spencer Jr., B.F.2    Sain, M.K.3    Carlson, J.D.4
  • 5
    • 14544284545 scopus 로고    scopus 로고
    • LuGre friction model for a magnetorheological damper
    • DOI 10.1002/stc.58
    • Jimenez R, Alvarez-Icaza L. LuGre friction model for a magnetorheological damper. Struct Control Health Monitor. 2005 ; 12: 91-116 (Pubitemid 40305113)
    • (2005) Structural Control and Health Monitoring , vol.12 , Issue.1 , pp. 91-116
    • Jimenez, R.1    Alvarez-Icaza, L.2
  • 7
    • 13844268977 scopus 로고    scopus 로고
    • Benchmark control problems for seismically excited nonlinear buildings
    • DOI 10.1061/(ASCE)0733-9399(2004)130:4(366)
    • Ohtori Y, Christenson RE, Spencer BF, Dyke SJ. Benchmark control problems for seismically excited nonlinear buildings. J Eng Mech. 2004 ; 130 (4). 366-385 (Pubitemid 38502910)
    • (2004) Journal of Engineering Mechanics , vol.130 , Issue.4 , pp. 366-385
    • Ohtori, Y.1    Christenson, R.E.2    Spencer Jr., B.F.3    Dyke, S.J.4
  • 8
    • 67849135880 scopus 로고    scopus 로고
    • Optimal semi-active preview control response of a half car vehicle model with magnetorheological damper
    • Prabakar RS, Sujatha C, Narayanan S. Optimal semi-active preview control response of a half car vehicle model with magnetorheological damper. J Sound Vib. 2009 ; 326: 400-420
    • (2009) J Sound Vib , vol.326 , pp. 400-420
    • Prabakar, R.S.1    Sujatha, C.2    Narayanan, S.3
  • 10
    • 0035451867 scopus 로고    scopus 로고
    • Semi-active control of seismic response of tall buildings with podium structure using ER/MR dampers
    • DOI 10.1002/tal.177
    • Qu WL, Xu YL. Semi-active control of seismic response of tall buildings with podium structure using ER/MR dampers. Struct Design Tall Build. 2001 ; 10: 179-192 (Pubitemid 32761182)
    • (2001) Structural Design of Tall Buildings , vol.10 , Issue.3 , pp. 179-192
    • Qu, W.L.1    Xu, Y.L.2
  • 12
  • 13
    • 0033150113 scopus 로고    scopus 로고
    • Semi-active control systems for seismic protection of structures: A state-of-art review
    • Symans MD, Constantinou MC. Semi-active control systems for seismic protection of structures: a state-of-art review. Engi Struct. 1999 ; 21: 469-487
    • (1999) Engi Struct , vol.21 , pp. 469-487
    • Symans, M.D.1    Constantinou, M.C.2
  • 14
    • 13844272520 scopus 로고    scopus 로고
    • Modeling and control of magnetorheological fluid dampers using neural networks
    • DOI 10.1088/0964-1726/14/1/011
    • Wang DH, Liao WH. Modelling and control of magnetorheological fluid dampers using neural networks. Smart Mater Struct. 2005 ; 14: 111-126 (Pubitemid 40253476)
    • (2005) Smart Materials and Structures , vol.14 , Issue.1 , pp. 111-126
    • Wang, D.H.1    Liao, W.H.2
  • 15
    • 33846050937 scopus 로고    scopus 로고
    • Modelling hysteretic behaviour in magnetorheological fluids and dampers using phase-transition theory
    • DOI 10.1088/0964-1726/15/6/027, PII S0964172606328996, 027
    • Wang LX, Kamath H. Modelling hysteretic behaviour in magnetorheological fluids and dampers using phase-transition theory. Smart Mater Struct. 2006 ; 15: 1725-1733 (Pubitemid 46069454)
    • (2006) Smart Materials and Structures , vol.15 , Issue.6 , pp. 1725-1733
    • Wang, L.X.1    Kamath, H.2
  • 16
    • 0016939287 scopus 로고
    • Method for random vibration of hysteretic systems
    • Wen YK. Method for random vibration of hysteretic systems. ASCE J Eng Mech Division. 1976 ; 102: 249-263
    • (1976) ASCE J Eng Mech Division , vol.102 , pp. 249-263
    • Wen, Y.K.1
  • 17
    • 0028548793 scopus 로고
    • Steady state oscillation of hysteretic differential model II: Performance analysis
    • Wong CW, Ni YQ, Ko JM. Steady state oscillation of hysteretic differential model II: performance analysis. ASCE J Eng Mech. 1994 ; 120 (11). 2299-2325
    • (1994) ASCE J Eng Mech , vol.120 , Issue.11 , pp. 2299-2325
    • Wong, C.W.1    Ni, Y.Q.2    Ko, J.M.3
  • 18
    • 20444451144 scopus 로고    scopus 로고
    • Semiactive seismic response control of buildings with podium structure
    • DOI 10.1061/(ASCE)0733-9445(2005)131:6(890)
    • Xu YL, Chen J, Ng CL, Qu WL. Semi-active seismic response control of buildings with podium structure. J Struct Eng. 2005 ; 131 (6). 890-899 (Pubitemid 40818715)
    • (2005) Journal of Structural Engineering , vol.131 , Issue.6 , pp. 890-899
    • Xu, Y.L.1    Chen, J.2    Ng, C.L.3    Qu, W.L.4
  • 19
    • 0042348286 scopus 로고    scopus 로고
    • Intelligent bi-state control for the structure with magnetorheological dampers
    • Xu ZD, Shen YP. Intelligent bi-state control for the structure with magnetorheological dampers. J Intell Mater Syst Struct. 2003 ; 14: 35-42
    • (2003) J Intell Mater Syst Struct , vol.14 , pp. 35-42
    • Xu, Z.D.1    Shen, Y.P.2
  • 20
    • 34848908795 scopus 로고    scopus 로고
    • Structural protection using MR dampers with clipped robust reliability-based control
    • DOI 10.1007/s00158-007-0097-3
    • Yuen KV, Shi Y, Beck JL, Lam HF. Structural protection using MR dampers with clipped robust reliability-based control. Struct Multidiscip Optim. 2007 ; 34: 431-443 (Pubitemid 47501694)
    • (2007) Structural and Multidisciplinary Optimization , vol.34 , Issue.5 , pp. 431-443
    • Yuen, K.-V.1    Shi, Y.2    Beck, J.L.3    Lam, H.-F.4
  • 21
    • 0035215832 scopus 로고    scopus 로고
    • A study on interaction control for seismic response of parallel structures
    • Zhu H, Wen Y, Iemura H. A study on interaction control for seismic response of parallel structures. Comput Struct. 2001 ; 79: 231-242
    • (2001) Comput Struct , vol.79 , pp. 231-242
    • Zhu, H.1    Wen, Y.2    Iemura, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.