메뉴 건너뛰기




Volumn 13, Issue SUPPL. 7, 2011, Pages 78-82

Robotic platforms for general and colorectal surgery

Author keywords

Minimally invasive; Robotic; Surgery

Indexed keywords

ARTICLE; COLORECTAL SURGERY; GENERAL SURGERY; HUMAN; MINIMALLY INVASIVE SURGERY; PRIORITY JOURNAL; ROBOTICS; SURGICAL APPROACH;

EID: 82055176296     PISSN: 14628910     EISSN: 14631318     Source Type: Journal    
DOI: 10.1111/j.1463-1318.2011.02788.x     Document Type: Article
Times cited : (8)

References (38)
  • 1
    • 0034018334 scopus 로고    scopus 로고
    • Robotics and telemanipulation technologies for endoscopic surgery. A review of the ARTEMIS project
    • Schurr MO. Robotics and telemanipulation technologies for endoscopic surgery. A review of the ARTEMIS project. Surg Endosc 2000; 14: 375-81.
    • (2000) Surg Endosc , vol.14 , pp. 375-381
    • Schurr, M.O.1
  • 2
    • 69249130053 scopus 로고    scopus 로고
    • The raven - design and validation of a telesurgery system. Int J Rob Res; (accessed July 2011).
    • Lum MJH, Friedman DCW, Sankaranarayanan G et al. The raven - design and validation of a telesurgery system. Int J Rob Res 2009; (accessed July 2011).
    • (2009)
    • Lum, M.J.H.1    Friedman, D.C.W.2    Sankaranarayanan, G.3
  • 3
    • 33646465841 scopus 로고    scopus 로고
    • Comparison of totally robotic laparoscopic Roux-en-Y gastric bypass and traditional laparoscopic Roux-en-Y gastric bypass
    • Sanchez BR, Mohr CJ, Morton JM, Safadi BY, Alami RS, Curet MJ. Comparison of totally robotic laparoscopic Roux-en-Y gastric bypass and traditional laparoscopic Roux-en-Y gastric bypass. Surg Obes Relat Dis 2005; 1: 549-54.
    • (2005) Surg Obes Relat Dis , vol.1 , pp. 549-554
    • Sanchez, B.R.1    Mohr, C.J.2    Morton, J.M.3    Safadi, B.Y.4    Alami, R.S.5    Curet, M.J.6
  • 4
    • 77649192119 scopus 로고    scopus 로고
    • Robotic gastrectomy for gastric cancer: surgical techniques and clinical merits
    • Kim M-C, Heo G-U, Jung G-J. Robotic gastrectomy for gastric cancer: surgical techniques and clinical merits. Surg Endosc 2009; 24: 610-5.
    • (2009) Surg Endosc , vol.24 , pp. 610-615
    • Kim, M.-C.1    Heo, G.-U.2    Jung, G.-J.3
  • 5
    • 78650180327 scopus 로고    scopus 로고
    • Robotic liver surgery: results for 70 resections
    • Giulianotti PC, Coratti A, Sbrana F et al. Robotic liver surgery: results for 70 resections. Surgery 2011; 149: 29-39.
    • (2011) Surgery , vol.149 , pp. 29-39
    • Giulianotti, P.C.1    Coratti, A.2    Sbrana, F.3
  • 6
    • 77954657077 scopus 로고    scopus 로고
    • "Chopstick" surgery: a novel technique improves surgeon performance and eliminates arm collision in robotic single-incision laparoscopic surgery
    • Joseph RA, Goh AC, Cuevas SP et al. "Chopstick" surgery: a novel technique improves surgeon performance and eliminates arm collision in robotic single-incision laparoscopic surgery. Surg Endosc 2009; 24: 1331-5.
    • (2009) Surg Endosc , vol.24 , pp. 1331-1335
    • Joseph, R.A.1    Goh, A.C.2    Cuevas, S.P.3
  • 7
    • 78649906109 scopus 로고    scopus 로고
    • Novel Robotic da Vinci instruments for laparoendoscopic single-site surgery
    • Haber G-P, White MA, Autorino R et al. Novel Robotic da Vinci instruments for laparoendoscopic single-site surgery. Urology 2010; 76: 1279-82.
    • (2010) Urology , vol.76 , pp. 1279-1282
    • Haber, G.-P.1    White, M.A.2    Autorino, R.3
  • 8
    • 33744799053 scopus 로고    scopus 로고
    • Davinci canvas: a telerobotic surgical system with integrated, robot-assisted, laparoscopic ultrasound capability
    • Leven J, Burschka D, Kumar R et al. Davinci canvas: a telerobotic surgical system with integrated, robot-assisted, laparoscopic ultrasound capability. Med Image Comput Comput Assist Interv 2005; 8: 811-8.
    • (2005) Med Image Comput Comput Assist Interv , vol.8 , pp. 811-818
    • Leven, J.1    Burschka, D.2    Kumar, R.3
  • 9
    • 80052261181 scopus 로고    scopus 로고
    • Intraoperative laparoscopic fluorescence guidance to the sentinel lymph node in prostate cancer patients: clinical proof of concept of an integrated functional imaging approach using a multimodal tracer. Eur Urol (in press); Corrected Proof. (accessed July 2011).
    • van der Poel HG, Buckle T, Brouwer OR, Valdés Olmos RA, van Leeuwen FWB. Intraoperative laparoscopic fluorescence guidance to the sentinel lymph node in prostate cancer patients: clinical proof of concept of an integrated functional imaging approach using a multimodal tracer. Eur Urol (in press); Corrected Proof. (accessed July 2011).
    • van der Poel, H.G.1    Buckle, T.2    Brouwer, O.R.3    Valdés Olmos, R.A.4    van Leeuwen, F.W.B.5
  • 10
    • 79958295070 scopus 로고    scopus 로고
    • Near infrared fluorescence imaging with robotic assisted laparoscopic partial nephrectomy: initial clinical experience for renal cortical tumors
    • Tobis S, Knopf J, Silvers C et al. Near infrared fluorescence imaging with robotic assisted laparoscopic partial nephrectomy: initial clinical experience for renal cortical tumors. J Urol 2011; 186: 47-52.
    • (2011) J Urol , vol.186 , pp. 47-52
    • Tobis, S.1    Knopf, J.2    Silvers, C.3
  • 11
    • 46249110406 scopus 로고    scopus 로고
    • The DLR MIRO: a versatile lightweight robot for surgical applications
    • Hagn U, Nickl M, Jörg S et al. The DLR MIRO: a versatile lightweight robot for surgical applications. Ind Rob: Int J 2008; 35: 324-36.
    • (2008) Ind Rob: Int J , vol.35 , pp. 324-336
    • Hagn, U.1    Nickl, M.2    Jörg, S.3
  • 12
    • 78649342396 scopus 로고    scopus 로고
    • MiroSurge - advanced user interaction modalities in minimally invasive robotic surgery
    • Tobergte A, Passig G, Kuebler B et al. MiroSurge - advanced user interaction modalities in minimally invasive robotic surgery. Presence (Camb) 2011; 19: 400-14.
    • (2011) Presence (Camb) , vol.19 , pp. 400-414
    • Tobergte, A.1    Passig, G.2    Kuebler, B.3
  • 13
    • 79955677937 scopus 로고    scopus 로고
    • Robots in healthcare
    • Bogue R. Robots in healthcare. Ind Rob: Int J 2011; 38: 218-23.
    • (2011) Ind Rob: Int J , vol.38 , pp. 218-223
    • Bogue, R.1
  • 14
    • 79954426404 scopus 로고    scopus 로고
    • Surgery in space: the future of robotic telesurgery
    • Haidegger T, Sándor J, Benyó Z. Surgery in space: the future of robotic telesurgery. Surg Endosc 2010; 25: 681-90.
    • (2010) Surg Endosc , vol.25 , pp. 681-690
    • Haidegger, T.1    Sándor, J.2    Benyó, Z.3
  • 17
    • 78650415782 scopus 로고    scopus 로고
    • ViKY robotic scope holder: initial clinical experience and preliminary results using instrument tracking
    • Voros S, Haber G-P, Menudet J-F, Long J-A, Cinquin P. ViKY robotic scope holder: initial clinical experience and preliminary results using instrument tracking. IEEE ASME Trans Mechatron 2010; 15: 879-86.
    • (2010) IEEE ASME Trans Mechatron , vol.15 , pp. 879-886
    • Voros, S.1    Haber, G.-P.2    Menudet, J.-F.3    Long, J.-A.4    Cinquin, P.5
  • 22
    • 34548405143 scopus 로고    scopus 로고
    • Recent in vivo surgical robot and mechanism developments
    • Rentschler ME, Oleynikov D. Recent in vivo surgical robot and mechanism developments. Surg Endosc 2007; 21: 1477-81.
    • (2007) Surg Endosc , vol.21 , pp. 1477-1481
    • Rentschler, M.E.1    Oleynikov, D.2
  • 23
    • 57149087955 scopus 로고    scopus 로고
    • Comparison of monoscopic insertable, remotely controlled imaging device with a standard laparoscope in a porcine model
    • Hogle NJ, Hu T, Allen PK, Fowler DL. Comparison of monoscopic insertable, remotely controlled imaging device with a standard laparoscope in a porcine model. Surg Innov 2008; 15: 271-6.
    • (2008) Surg Innov , vol.15 , pp. 271-276
    • Hogle, N.J.1    Hu, T.2    Allen, P.K.3    Fowler, D.L.4
  • 24
    • 70349768439 scopus 로고    scopus 로고
    • Novel magnetically guided intra-abdominal camera to facilitate laparoendoscopic single-site surgery: initial human experience
    • Cadeddu J, Fernandez R, Desai M et al. Novel magnetically guided intra-abdominal camera to facilitate laparoendoscopic single-site surgery: initial human experience. Surg Endosc 2009; 23: 1894-9.
    • (2009) Surg Endosc , vol.23 , pp. 1894-1899
    • Cadeddu, J.1    Fernandez, R.2    Desai, M.3
  • 25
    • 77952994843 scopus 로고    scopus 로고
    • A magnetic internal mechanism for precise orientation of the camera in wireless endoluminal applications
    • Valdastri P, Quaglia C, Buselli E et al. A magnetic internal mechanism for precise orientation of the camera in wireless endoluminal applications. Endoscopy 2010; 42: 481-6.
    • (2010) Endoscopy , vol.42 , pp. 481-486
    • Valdastri, P.1    Quaglia, C.2    Buselli, E.3
  • 26
    • 65249167480 scopus 로고    scopus 로고
    • Natural orifice cholecystectomy using a miniature robot
    • Lehman AC, Dumpert J, Wood NA et al. Natural orifice cholecystectomy using a miniature robot. Surg Endosc 2009; 23: 260-6.
    • (2009) Surg Endosc , vol.23 , pp. 260-266
    • Lehman, A.C.1    Dumpert, J.2    Wood, N.A.3
  • 28
    • 84856179168 scopus 로고    scopus 로고
    • Miniature in vivo robot for laparoendoscopic single-site surgery. Surg Endosc; (accessed July 2011).
    • Dolghi O, Strabala KW, Wortman TD, Goede MR, Farritor SM, Oleynikov D. Miniature in vivo robot for laparoendoscopic single-site surgery. Surg Endosc 2011; (accessed July 2011).
    • (2011)
    • Dolghi, O.1    Strabala, K.W.2    Wortman, T.D.3    Goede, M.R.4    Farritor, S.M.5    Oleynikov, D.6
  • 30
    • 78650419110 scopus 로고    scopus 로고
    • Design of a novel bimanual robotic system for single-port laparoscopy
    • Piccigallo M, Scarfogliero U, Quaglia C et al. Design of a novel bimanual robotic system for single-port laparoscopy. IEEE ASME Trans Mechatron 2010; 15: 871-8.
    • (2010) IEEE ASME Trans Mechatron , vol.15 , pp. 871-878
    • Piccigallo, M.1    Scarfogliero, U.2    Quaglia, C.3
  • 31
    • 78650911581 scopus 로고    scopus 로고
    • Magnetic anchoring and guidance system instrumentation for laparo-endoscopic single-site surgery/natural orifice transluminal endoscopic surgery: lack of histologic damage after prolonged magnetic coupling across the abdominal wall
    • Best SL, Kabbani W, Scott DJ et al. Magnetic anchoring and guidance system instrumentation for laparo-endoscopic single-site surgery/natural orifice transluminal endoscopic surgery: lack of histologic damage after prolonged magnetic coupling across the abdominal wall. Urology 2011; 77: 243-7.
    • (2011) Urology , vol.77 , pp. 243-247
    • Best, S.L.1    Kabbani, W.2    Scott, D.J.3
  • 32
    • 67650630642 scopus 로고    scopus 로고
    • Vision and task assistance using modular wireless in vivo surgical robots
    • Platt SR, Hawks JA, Rentschler ME. Vision and task assistance using modular wireless in vivo surgical robots. IEEE Trans Biomed Eng 2009; 56: 1700-10.
    • (2009) IEEE Trans Biomed Eng , vol.56 , pp. 1700-1710
    • Platt, S.R.1    Hawks, J.A.2    Rentschler, M.E.3
  • 33
    • 77954857155 scopus 로고    scopus 로고
    • Wet adhesion for a miniature mobile intra-abdominal device based on biomimetic principles. Proceedings of the Institution of Mechanical Engineers Part C-Journal of Mechanical Engineering Science; Issue: C7 Special Issue: Sp. Iss. SI Pages: -
    • Taylor GW, Neville A, Jayne DG et al. Wet adhesion for a miniature mobile intra-abdominal device based on biomimetic principles. Proceedings of the Institution of Mechanical Engineers Part C-Journal of Mechanical Engineering Science 2010; 224 Issue: C7 Special Issue: Sp. Iss. SI Pages: 1473-85.
    • (2010) , vol.224 , pp. 1473-1485
    • Taylor, G.W.1    Neville, A.2    Jayne, D.G.3
  • 34
    • 82055187627 scopus 로고    scopus 로고
    • Understanding tribological and adhesion properties of a micro-structured surface to peritoneal tissue for an intra-abdominal device
    • (in press).
    • Roshan R, Jayne DG, Liskiewicz T, Montellano Lopez A, Morina A, Neville A. Understanding tribological and adhesion properties of a micro-structured surface to peritoneal tissue for an intra-abdominal device. Acta Biomater (in press).
    • Acta Biomater
    • Roshan, R.1    Jayne, D.G.2    Liskiewicz, T.3    Montellano Lopez, A.4    Morina, A.5    Neville, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.