Volumn 160, Issue 1, 2011, Pages 1098-1105

Amperometric inhibition-based detection of organophosphorus pesticides in unary and binary mixtures employing flow-injection analysis

Author keywords

Amperometric biosensor; Flow injection system; Immobilized acetylcholinesterase; Pesticides

Indexed keywords

ACETYLCHOLINESTERASE; AMPEROMETRIC; AMPEROMETRIC BIOSENSORS; AMPEROMETRIC MEASUREMENTS; CALIBRATION CURVES; CALIBRATION PLOT; CORRELATION COEFFICIENT; DETECTION LIMITS; DICHLORVOS; ENZYME MEMBRANES; FLOW-INJECTION ANALYSIS; FLOW-INJECTION SYSTEM; INHIBITION CONSTANTS; LINEAR INTERVALS; MONOCROTOPHOS; OPTIMAL OPERATING CONDITIONS; ORGANOPHOSPHORUS PESTICIDE; PARAOXON; RESIDUAL ACTIVITY; RESIDUAL ENZYMES; STORAGE STABILITY; STORAGE TIME; SUBSTRATE CONCENTRATIONS;

EID: 81155148201     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.09.033     Document Type: Article
Times cited : (21)

References (32)
  • 1
    • 78650039937 scopus 로고    scopus 로고
    • Review on the use of enzymes for the detection of organochlorine, organophosphate and carbamate pesticides in the environment
    • J. Van Dyk, and B. Pletschke Review on the use of enzymes for the detection of organochlorine, organophosphate and carbamate pesticides in the environment Chemosphere 82 2011 291 307
    • (2011) Chemosphere , vol.82 , pp. 291-307
    • Van Dyk, J.1    Pletschke, B.2
  • 2
    • 32644444408 scopus 로고    scopus 로고
    • Twenty years research in cholinesterase biosensors: From basic research to practical applications
    • S. Andreescu, and J.-L. Marty Twenty years research in cholinesterase biosensors: from basic research to practical applications Biomolecular Engineering 23 2006 1 15
    • (2006) Biomolecular Engineering , vol.23 , pp. 1-15
    • Andreescu, S.1    Marty, J.-L.2
  • 3
    • 80555155582 scopus 로고    scopus 로고
    • Nanomaterials based biosensors for food analysis applications
    • 10.1016/j.tifs.2011.04.001
    • B. Pérez-López, and A. Merkoi Nanomaterials based biosensors for food analysis applications Trends in Food Science & Technology 2011 10.1016/j.tifs.2011.04.001
    • (2011) Trends in Food Science & Technology
    • Pérez-López, B.1    Merkoi, A.2
  • 5
    • 31044455163 scopus 로고    scopus 로고
    • Enzyme inhibition-based biosensors for food safety and environmental monitoring
    • A. Amine, H. Mohammadi, I. Bourais, and G. Palleschi Enzyme inhibition-based biosensors for food safety and environmental monitoring Biosensors and Bioelectronics 21 2006 1405 1423
    • (2006) Biosensors and Bioelectronics , vol.21 , pp. 1405-1423
    • Amine, A.1    Mohammadi, H.2    Bourais, I.3    Palleschi, G.4
  • 6
    • 0033025195 scopus 로고    scopus 로고
    • Amperometric flow-through biosensor for the determination of cholinesterase inhibitors
    • G. Evtugyn, A. Ivanov, E. Gogol, J.-L. Marty, and H. Budnikov Amperometric flow-through biosensor for the determination of cholinesterase inhibitors Analytica Chimica Acta 385 1999 13 21
    • (1999) Analytica Chimica Acta , vol.385 , pp. 13-21
    • Evtugyn, G.1    Ivanov, A.2    Gogol, E.3    Marty, J.-L.4    Budnikov, H.5
  • 7
    • 0035370091 scopus 로고    scopus 로고
    • Automated detection of chlorpyrifos and its metabolites by a continuous flow system-based enzyme sensor
    • G. Jeanty, C. Ghommidh, and J.-L. Marty Automated detection of chlorpyrifos and its metabolites by a continuous flow system-based enzyme sensor Analytica Chimica Acta 436 2001 119 128
    • (2001) Analytica Chimica Acta , vol.436 , pp. 119-128
    • Jeanty, G.1    Ghommidh, C.2    Marty, J.-L.3
  • 8
    • 31344454566 scopus 로고    scopus 로고
    • Binding of acetylcholinesterase to multiwall carbon nanotube-cross-linked chitosan composite for flow-injection amperometric detection of an organophosphorous insecticide
    • V. Kandimalla, and H. Ju Binding of acetylcholinesterase to multiwall carbon nanotube-cross-linked chitosan composite for flow-injection amperometric detection of an organophosphorous insecticide Chemistry - European Journal 12 2006 1074 1080
    • (2006) Chemistry - European Journal , vol.12 , pp. 1074-1080
    • Kandimalla, V.1    Ju, H.2
  • 9
    • 70349600273 scopus 로고    scopus 로고
    • Recent developments in electrochemical flow detections - A review. Part I. Flow analysis and capillary electrophoresis
    • M. Trojanowicz Recent developments in electrochemical flow detections - a review. Part I. Flow analysis and capillary electrophoresis Analytica Chimica Acta 653 2009 36 58
    • (2009) Analytica Chimica Acta , vol.653 , pp. 36-58
    • Trojanowicz, M.1
  • 10
    • 0001242480 scopus 로고
    • Affinity and phosphorylation constants for the inhibition of esterases by organophosphates
    • A. Main Affinity and phosphorylation constants for the inhibition of esterases by organophosphates Science 22 1964 992 993
    • (1964) Science , vol.22 , pp. 992-993
    • Main, A.1
  • 12
    • 0028133523 scopus 로고
    • Reactivation of an immobilized enzyme reactor for the determination of acetylcholinesterase inhibitors. Flow injection determination of paraoxon
    • C. García de María, T. Muñoz, and A. Townshend Reactivation of an immobilized enzyme reactor for the determination of acetylcholinesterase inhibitors. Flow injection determination of paraoxon Analytica Chimica Acta 295 1994 287 296
    • (1994) Analytica Chimica Acta , vol.295 , pp. 287-296
    • García De María, C.1    Muñoz, T.2    Townshend, A.3
  • 13
    • 0037140952 scopus 로고    scopus 로고
    • Reactivation of immobilized acetyl cholinesterase in an amperometric biosensor for organophosphorus pesticide
    • K. Gulla, M. Gouda, M. Thakur, and N. Karanth Reactivation of immobilized acetyl cholinesterase in an amperometric biosensor for organophosphorus pesticide Biochimica et Biophysica Acta 1597 2002 133 139
    • (2002) Biochimica et Biophysica Acta , vol.1597 , pp. 133-139
    • Gulla, K.1    Gouda, M.2    Thakur, M.3    Karanth, N.4
  • 14
    • 68349144417 scopus 로고    scopus 로고
    • New series of monoquaternary pyridinium oximes: Synthesis and reactivation potency for paraoxon-inhibited electric eel and recombinant human acetylcholinesterase
    • S. Bharate, L. Guo, T. Reeves, D. Cerasoli, and C. Thompson New series of monoquaternary pyridinium oximes: synthesis and reactivation potency for paraoxon-inhibited electric eel and recombinant human acetylcholinesterase Bioorganic & Medicinal Chemistry Letters 19 2009 5101 5104
    • (2009) Bioorganic & Medicinal Chemistry Letters , vol.19 , pp. 5101-5104
    • Bharate, S.1    Guo, L.2    Reeves, T.3    Cerasoli, D.4    Thompson, C.5
  • 15
    • 71549162552 scopus 로고    scopus 로고
    • Amperometric acetylthiocholine sensor based on acetylcholinesterase immobilized on nanostructured polymer membrane containing gold nanoparticles
    • I. Marinov, Y. Ivanov, K. Gabrovska, and T. Godjevargova Amperometric acetylthiocholine sensor based on acetylcholinesterase immobilized on nanostructured polymer membrane containing gold nanoparticles Journal of Molecular Catalysis B: Enzymatic 62 2010 67 75
    • (2010) Journal of Molecular Catalysis B: Enzymatic , vol.62 , pp. 67-75
    • Marinov, I.1    Ivanov, Y.2    Gabrovska, K.3    Godjevargova, T.4
  • 17
    • 24944508568 scopus 로고    scopus 로고
    • Insecticide detection through protein engineering of Nippostrongylus brasiliensis acetylcholinesterase B
    • H. Schulze, S. Muench, F. Villatte, R. Schmid, and T. Bachmann Insecticide detection through protein engineering of Nippostrongylus brasiliensis acetylcholinesterase B Analytical Chemistry 77 2005 5823 5830
    • (2005) Analytical Chemistry , vol.77 , pp. 5823-5830
    • Schulze, H.1    Muench, S.2    Villatte, F.3    Schmid, R.4    Bachmann, T.5
  • 18
    • 33745256183 scopus 로고    scopus 로고
    • On-chip integrated hydrolysis, fluorescent labeling, and electrophoretic separation utilized for acetylcholinesterase assay
    • V. Heleg-Shabtai, N. Gratziany, and Z. Liron On-chip integrated hydrolysis, fluorescent labeling, and electrophoretic separation utilized for acetylcholinesterase assay Analytica Chimica Acta 571 2006 228 234
    • (2006) Analytica Chimica Acta , vol.571 , pp. 228-234
    • Heleg-Shabtai, V.1    Gratziany, N.2    Liron, Z.3
  • 19
    • 0036523489 scopus 로고    scopus 로고
    • Detection of pesticides using an amperometric biosensor based on ferophthalocyanine chemically modified carbon paste electrode and immobilized bienzymatic system
    • A. Ciucu, C. Negulescu, and R. Baldwin Detection of pesticides using an amperometric biosensor based on ferophthalocyanine chemically modified carbon paste electrode and immobilized bienzymatic system Biosensors and Bioelectronics 18 2003 303 310
    • (2003) Biosensors and Bioelectronics , vol.18 , pp. 303-310
    • Ciucu, A.1    Negulescu, C.2    Baldwin, R.3
  • 21
    • 0032007153 scopus 로고    scopus 로고
    • Engineering sensitive acetylcholinesterase for detection of organophosphate and carbamate insecticides
    • F. Villatte, V. Marcel, S. Estrada-Mondaca, and D. Fournier Engineering sensitive acetylcholinesterase for detection of organophosphate and carbamate insecticides Biosensors and Bioelectronics 13 1998 157 164
    • (1998) Biosensors and Bioelectronics , vol.13 , pp. 157-164
    • Villatte, F.1    Marcel, V.2    Estrada-Mondaca, S.3    Fournier, D.4
  • 22
    • 0036883617 scopus 로고    scopus 로고
    • Development, validation, and application of an acetylcholinesterase- biosensor test for the direct detection of insecticide residues in infant food
    • H. Schulze, E. Scherbaum, M. Anastassiades, S. Vorlova, R. Schmid, and T. Bachmann Development, validation, and application of an acetylcholinesterase- biosensor test for the direct detection of insecticide residues in infant food Biosensors and Bioelectronics 17 2002 1095 1105
    • (2002) Biosensors and Bioelectronics , vol.17 , pp. 1095-1105
    • Schulze, H.1    Scherbaum, E.2    Anastassiades, M.3    Vorlova, S.4    Schmid, R.5    Bachmann, T.6
  • 23
    • 74349101119 scopus 로고    scopus 로고
    • Selective spectrophotometric detection of insecticides using cholinesterases, phosphotriesterase and chemometric analysis
    • A. Rhouati, G. Istamboulie, M. Cortina-Puig, J.-L. Marty, and T. Noguer Selective spectrophotometric detection of insecticides using cholinesterases, phosphotriesterase and chemometric analysis Enzyme and Microbial Technology 46 2010 212 216
    • (2010) Enzyme and Microbial Technology , vol.46 , pp. 212-216
    • Rhouati, A.1    Istamboulie, G.2    Cortina-Puig, M.3    Marty, J.-L.4    Noguer, T.5
  • 24
    • 58149150036 scopus 로고    scopus 로고
    • Automated resolution of dichlorvos and methylparaoxon pesticide mixtures employing a Flow Injection system with an inhibition electronic tongue
    • G. Valdés-Ramírez, M. Gutiérrez, M. del Valle, M. Ramírez-Silva, D. Fournier, and J.-L. Marty Automated resolution of dichlorvos and methylparaoxon pesticide mixtures employing a Flow Injection system with an inhibition electronic tongue Biosensors and Bioelectronics 24 2009 1103 1108
    • (2009) Biosensors and Bioelectronics , vol.24 , pp. 1103-1108
    • Valdés-Ramírez, G.1    Gutiérrez, M.2    Del Valle, M.3    Ramírez-Silva, M.4    Fournier, D.5    Marty, J.-L.6
  • 25
    • 0346725086 scopus 로고    scopus 로고
    • Determination of binary pesticide mixtures by an acetylcholinesterase- choline oxidase biosensor
    • F. Kok, and V. Hasirci Determination of binary pesticide mixtures by an acetylcholinesterase-choline oxidase biosensor Biosensors and Bioelectronics 19 2004 661 665
    • (2004) Biosensors and Bioelectronics , vol.19 , pp. 661-665
    • Kok, F.1    Hasirci, V.2
  • 26
    • 0035691831 scopus 로고    scopus 로고
    • A theoretical model for immobilized enzyme inhibition biosensors
    • S. Zhang, H. Zhao, and R. John A theoretical model for immobilized enzyme inhibition biosensors Electroanalysis 13 2001 1528 1534
    • (2001) Electroanalysis , vol.13 , pp. 1528-1534
    • Zhang, S.1    Zhao, H.2    John, R.3
  • 27
    • 0029029334 scopus 로고
    • Amperometric flow-through biosensor for the determination of pesticides
    • C. La Rosa, F. Pariente, L. Hernhdez, and E. Lorenzo Amperometric flow-through biosensor for the determination of pesticides Analytica Chimica Acta 308 1995 129 136
    • (1995) Analytica Chimica Acta , vol.308 , pp. 129-136
    • La Rosa, C.1    Pariente, F.2    Hernhdez, L.3    Lorenzo, E.4
  • 28
    • 0036038874 scopus 로고    scopus 로고
    • Flow-injection amperometric determination of pesticides on the basis of their inhibition of immobilized acetylcholinesterases of different origin
    • G. Jeanty, A. Wojciechowska, J.-L. Marty, and M. Trojanowicz Flow-injection amperometric determination of pesticides on the basis of their inhibition of immobilized acetylcholinesterases of different origin Analytical and Bioanalytical Chemistry 373 2002 691 695
    • (2002) Analytical and Bioanalytical Chemistry , vol.373 , pp. 691-695
    • Jeanty, G.1    Wojciechowska, A.2    Marty, J.-L.3    Trojanowicz, M.4
  • 29
    • 32444433649 scopus 로고    scopus 로고
    • Biosensor based on self-assembling acetylcholinesterase on carbon nanotubes for flow injection/amperometric detection of organophosphate pesticides and nerve agents
    • G. Liu, and Y. Lin Biosensor based on self-assembling acetylcholinesterase on carbon nanotubes for flow injection/amperometric detection of organophosphate pesticides and nerve agents Analytical Chemistry 78 2006 835 843
    • (2006) Analytical Chemistry , vol.78 , pp. 835-843
    • Liu, G.1    Lin, Y.2
  • 30
    • 0032007154 scopus 로고    scopus 로고
    • Biosensor based on self-assembling acetylcholinesterase on carbon nanotubes for flow injection/amperometric detection of organophosphate pesticides and nerve agents
    • G. Jeanty, and J.-L. Marty Biosensor based on self-assembling acetylcholinesterase on carbon nanotubes for flow injection/amperometric detection of organophosphate pesticides and nerve agents Biosensors and Bioelectronics 13 1998 213 218
    • (1998) Biosensors and Bioelectronics , vol.13 , pp. 213-218
    • Jeanty, G.1    Marty, J.-L.2
  • 31
    • 14644440792 scopus 로고    scopus 로고
    • Sonochemically fabricated acetylcholinesterase micro-electrode arrays within a flow injection analyser for the determination of organophosphate pesticides
    • K. Law, and S. Higson Sonochemically fabricated acetylcholinesterase micro-electrode arrays within a flow injection analyser for the determination of organophosphate pesticides Biosensors and Bioelectronics 20 2005 1914 1924
    • (2005) Biosensors and Bioelectronics , vol.20 , pp. 1914-1924
    • Law, K.1    Higson, S.2
  • 32
    • 30644466642 scopus 로고    scopus 로고
    • A mediator-free screen-printed amperometric biosensor for screening of organophosphorus pesticides with flow-injection analysis (FIA) system
    • M. Shi, J. Xu, S. Zhang, B. Liu, and J. Kong A mediator-free screen-printed amperometric biosensor for screening of organophosphorus pesticides with flow-injection analysis (FIA) system Talanta 68 2006 1089 1095
    • (2006) Talanta , vol.68 , pp. 1089-1095
    • Shi, M.1    Xu, J.2    Zhang, S.3    Liu, B.4    Kong, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.