메뉴 건너뛰기




Volumn 20, Issue 10 SPEC. ISS., 2005, Pages 1914-1924

Sonochemically fabricated acetylcholinesterase micro-electrode arrays within a flow injection analyser for the determination of organophosphate pesticides

Author keywords

Amperometric; Micro electrode arrays; Pesticides; Sonochemistry

Indexed keywords

BINARY MIXTURES; BIOMEDICAL ENGINEERING; COBALT COMPOUNDS; CONCENTRATION (PROCESS); ELECTRODES; ENZYME IMMOBILIZATION; PESTICIDES; PHOSPHATES; SONOCHEMISTRY; SUGAR (SUCROSE);

EID: 14644440792     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bios.2004.08.048     Document Type: Conference Paper
Times cited : (70)

References (35)
  • 1
    • 0032527917 scopus 로고    scopus 로고
    • Determination of organophosphorus and carbamate pesticides using a piezoelectric biosensor
    • J.M. Abad, F. Pariente, L. Hernandez, H.D. Abruna, and E. Lorenzo Determination of organophosphorus and carbamate pesticides using a piezoelectric biosensor Anal. Chem. 70 1998 2848 2855
    • (1998) Anal. Chem. , vol.70 , pp. 2848-2855
    • Abad, J.M.1    Pariente, F.2    Hernandez, L.3    Abruna, H.D.4    Lorenzo, E.5
  • 3
    • 0034210910 scopus 로고    scopus 로고
    • Improved multianalyte detection of organophosphates and carbamates with disposable multielectrode biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks
    • T.T. Bachmann, B. Leca, F. Vilatte, J.-L. Marty, D. Fournier, and R.D. Schmid Improved multianalyte detection of organophosphates and carbamates with disposable multielectrode biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks Biosens. Bioelectron. 15 2000 193 201
    • (2000) Biosens. Bioelectron. , vol.15 , pp. 193-201
    • Bachmann, T.T.1    Leca, B.2    Vilatte, F.3    Marty, J.-L.4    Fournier, D.5    Schmid, R.D.6
  • 4
    • 0032728583 scopus 로고    scopus 로고
    • A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution
    • T.T. Bachmann, and R.D. Schmid A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution Anal. Chim. Acta. 401 1999 95 103
    • (1999) Anal. Chim. Acta. , vol.401 , pp. 95-103
    • Bachmann, T.T.1    Schmid, R.D.2
  • 6
    • 0030258217 scopus 로고    scopus 로고
    • Direct electron transfer-based tri-enzyme electrode for monitoring of organophosphorus pesticides
    • J. Diehl-Faxon, A.L. Ghindilis, P. Atanasov, and E. Wilkins Direct electron transfer-based tri-enzyme electrode for monitoring of organophosphorus pesticides. Sens. Actuat. B - Chem. 36 1-3 1996 448 457
    • (1996) Sens. Actuat. B - Chem. , vol.36 , Issue.1-3 , pp. 448-457
    • Diehl-Faxon, J.1    Ghindilis, A.L.2    Atanasov, P.3    Wilkins, E.4
  • 7
    • 0002390776 scopus 로고    scopus 로고
    • Development of a disposable organophosphate biosensor
    • M. Espinosa, P. Atanasov, and E. Wilkins Development of a disposable organophosphate biosensor Electroanalysis 11 14 1999 1055 1062
    • (1999) Electroanalysis , vol.11 , Issue.14 , pp. 1055-1062
    • Espinosa, M.1    Atanasov, P.2    Wilkins, E.3
  • 8
    • 14644387159 scopus 로고    scopus 로고
    • European Commission: EU Water Framework Directive 2000/60/EC.
    • European Commission: EU Water Framework Directive 2000/60/EC.
  • 9
    • 14644400756 scopus 로고    scopus 로고
    • European Commission: Drinking Water Directive 98/83/EC.
    • European Commission: Drinking Water Directive 98/83/EC.
  • 10
    • 0031817907 scopus 로고    scopus 로고
    • Sensitivity and selectivity of electrochemical enzyme sensors for inhibitor determination
    • G.A. Evtugyn, H.C. Budnikov, and E.B. Nikolskaya Sensitivity and selectivity of electrochemical enzyme sensors for inhibitor determination Talanta 46 1998 465 484
    • (1998) Talanta , vol.46 , pp. 465-484
    • Evtugyn, G.A.1    Budnikov, H.C.2    Nikolskaya, E.B.3
  • 11
    • 0030480213 scopus 로고    scopus 로고
    • Influence of surface-active compounds on the response of cholinesterase biosensors for inhibitor determination
    • G.A. Evtugyn, H.C. Budnikov, and E.B. Nikolskaya Influence of surface-active compounds on the response of cholinesterase biosensors for inhibitor determination Analyst 121 1996 1911 1915
    • (1996) Analyst , vol.121 , pp. 1911-1915
    • Evtugyn, G.A.1    Budnikov, H.C.2    Nikolskaya, E.B.3
  • 12
    • 0042639157 scopus 로고    scopus 로고
    • Improvements in the stability characteristics of biosensors using protein-polyelectrolyte complexes
    • T.D. Gibson, B.L.J. Pierce, J.N. Hulbert, and S. Gillespie Improvements in the stability characteristics of biosensors using protein-polyelectrolyte complexes Sens. Actuat. B - Chem. 33 1996 13 18
    • (1996) Sens. Actuat. B - Chem. , vol.33 , pp. 13-18
    • Gibson, T.D.1    Pierce, B.L.J.2    Hulbert, J.N.3    Gillespie, S.4
  • 13
    • 0029744541 scopus 로고    scopus 로고
    • Potentiometric biosensors for cholinesterase inhibitor analysis based on mediatorless bioelectrocatalysis
    • A.L. Ghindilis, T.G. Morzunova, A.V. Barmin, and I.N. Kurochkin Potentiometric biosensors for cholinesterase inhibitor analysis based on mediatorless bioelectrocatalysis Biosens. Bioelectron. 11 1996 873 880
    • (1996) Biosens. Bioelectron. , vol.11 , pp. 873-880
    • Ghindilis, A.L.1    Morzunova, T.G.2    Barmin, A.V.3    Kurochkin, I.N.4
  • 14
    • 0031934934 scopus 로고    scopus 로고
    • A new spray reagent for the detection of synthetic pyrethoids containing a nitrile group on thin-layer plates
    • S. Gupta, S.K. Handa, and K.K. Sharma A new spray reagent for the detection of synthetic pyrethoids containing a nitrile group on thin-layer plates Talanta 45 6 1998 1111 1114
    • (1998) Talanta , vol.45 , Issue.6 , pp. 1111-1114
    • Gupta, S.1    Handa, S.K.2    Sharma, K.K.3
  • 15
    • 0030819417 scopus 로고    scopus 로고
    • The response of screen-printed enzyme electrodes containing cholinesterases to organo-phosphates in solution and from commercial formulations
    • A.L. Hart, W.A. Collier, and D. Janssen The response of screen-printed enzyme electrodes containing cholinesterases to organo-phosphates in solution and from commercial formulations Biosens. Bioelectron. 12 1997 645 654
    • (1997) Biosens. Bioelectron. , vol.12 , pp. 645-654
    • Hart, A.L.1    Collier, W.A.2    Janssen, D.3
  • 18
    • 14644441363 scopus 로고    scopus 로고
    • Sensor International Patent: PCT/GB96/00922, continuation of UK patent 9507991 - filed 19th November 1996. Patents granted to date in Europe, US, Canada, Japan and Australia.
    • Higson, S.P.J., Sensor International Patent: PCT/GB96/00922, continuation of UK patent 9507991 - filed 19th November 1996. Patents granted to date in Europe, US, Canada, Japan and Australia.
    • Higson, S.P.J.1
  • 19
    • 0033990869 scopus 로고    scopus 로고
    • Comparative investigation of electrochemical cholinesterase biosensors for pesticide determination
    • A.N. Ivanov, G.A. Evtugyn, R.E. Gyurcsányi, K. Tóth, and H.C. Budnikov Comparative investigation of electrochemical cholinesterase biosensors for pesticide determination Anal. Chim. Acta 404 1 2000 55 65
    • (2000) Anal. Chim. Acta , vol.404 , Issue.1 , pp. 55-65
    • Ivanov, A.N.1    Evtugyn, G.A.2    Gyurcsányi, R.E.3    Tóth, K.4    Budnikov, H.C.5
  • 20
    • 0035370091 scopus 로고    scopus 로고
    • Automated detection of chlorpyrifos and its metabolites by a continuous flow system-based enzyme sensor
    • G. Jeanty, Ch. Ghommidh, and J.L. Marty Automated detection of chlorpyrifos and its metabolites by a continuous flow system-based enzyme sensor Anal. Chim. Acta 436 1 2001 119 128
    • (2001) Anal. Chim. Acta , vol.436 , Issue.1 , pp. 119-128
    • Jeanty, G.1    Ghommidh, Ch.2    Marty, J.L.3
  • 21
    • 0014674227 scopus 로고
    • Molecular properties of acetylcholinesterase
    • W. Leuzinger, M. Goldberg, and E. Cauvin Molecular properties of acetylcholinesterase J. Mol. Biol. 40 1969 217 225
    • (1969) J. Mol. Biol. , vol.40 , pp. 217-225
    • Leuzinger, W.1    Goldberg, M.2    Cauvin, E.3
  • 22
    • 0034940546 scopus 로고    scopus 로고
    • Spectroscopic investigation on polymer films obtained by oxidation of o-phenylenediamine on platinum electrodes at different pHs
    • H. Losito, E. De Giglio, N. Cioffi, and C. Malitesta Spectroscopic investigation on polymer films obtained by oxidation of o-phenylenediamine on platinum electrodes at different pHs J. Mater. Chem. 11 2001 1812 1817
    • (2001) J. Mater. Chem. , vol.11 , pp. 1812-1817
    • Losito, H.1    De Giglio, E.2    Cioffi, N.3    Malitesta, C.4
  • 23
    • 0030284960 scopus 로고    scopus 로고
    • Environmental applications of analytical biosensors
    • M.-P. Marco, and D. Barcelo Environmental applications of analytical biosensors Meas. Sci. Technol. 7 11 1996 1547 1562
    • (1996) Meas. Sci. Technol. , vol.7 , Issue.11 , pp. 1547-1562
    • Marco, M.-P.1    Barcelo, D.2
  • 24
    • 0028136099 scopus 로고
    • Acetylcholinesterase in organic solvents for the detection of pesticides: Biosensor application
    • N. Mionetto, J.-L. Marty, and I. Karube Acetylcholinesterase in organic solvents for the detection of pesticides: biosensor application Biosens. Bioelectron. 9 1994 463 470
    • (1994) Biosens. Bioelectron. , vol.9 , pp. 463-470
    • Mionetto, N.1    Marty, J.-L.2    Karube, I.3
  • 25
    • 0035869359 scopus 로고    scopus 로고
    • Disposable cholinesterase biosensor for the detection of pesticides in water-miscible organic solvents
    • T. Montesinos, S. Pérez-Munguia, F. Valdez, and J.L. Marty Disposable cholinesterase biosensor for the detection of pesticides in water-miscible organic solvents Anal. Chim. Acta. 431 2001 231 237
    • (2001) Anal. Chim. Acta. , vol.431 , pp. 231-237
    • Montesinos, T.1    Pérez-Munguia, S.2    Valdez, F.3    Marty, J.L.4
  • 26
    • 14644439517 scopus 로고    scopus 로고
    • Ph.D. Thesis, UMIST, Manchester, UK.
    • Myler, S., 2000. Ph.D. Thesis, UMIST, Manchester, UK.
    • (2000)
    • Myler, S.1
  • 27
    • 0026838908 scopus 로고
    • Determination of organophosphorus insecticides with a choline electrochemical biosensor
    • G. Palleschi, M. Bernabei, C. Cremisini, and M. Mascini Determination of organophosphorus insecticides with a choline electrochemical biosensor Sens. Actuators B 7 1992 513 517
    • (1992) Sens. Actuators B , vol.7 , pp. 513-517
    • Palleschi, G.1    Bernabei, M.2    Cremisini, C.3    Mascini, M.4
  • 28
    • 7444225756 scopus 로고    scopus 로고
    • Sonochemically fabricated micro-electrode arrays for the environmental monitoring of pesticides
    • J. Pritchard, K. Law, A. Vakurov, P. Millner, and S.P.J. Higson Sonochemically fabricated micro-electrode arrays for the environmental monitoring of pesticides Biosens. Bioelectron. 20 2004 765 772
    • (2004) Biosens. Bioelectron. , vol.20 , pp. 765-772
    • Pritchard, J.1    Law, K.2    Vakurov, A.3    Millner, P.4    Higson, S.P.J.5
  • 29
    • 0030808758 scopus 로고    scopus 로고
    • Flow-injection detector incorporating a screen-printed disposable amperometric biosensor for monitoring organophosphorus pesticides
    • J.J. Rippeth, T.D. Gibson, J.P. Hart, I.C. Hartley, and G. Nelson Flow-injection detector incorporating a screen-printed disposable amperometric biosensor for monitoring organophosphorus pesticides. Analyst 122 11 1997 1425 1429
    • (1997) Analyst , vol.122 , Issue.11 , pp. 1425-1429
    • Rippeth, J.J.1    Gibson, T.D.2    Hart, J.P.3    Hartley, I.C.4    Nelson, G.5
  • 31
    • 0001985710 scopus 로고    scopus 로고
    • Biosensors based on cholinesterase for detection of pesticides
    • P. Skladal Biosensors based on cholinesterase for detection of pesticides Food Technol. Biotechnol. 34 1996 43 49
    • (1996) Food Technol. Biotechnol. , vol.34 , pp. 43-49
    • Skladal, P.1
  • 32
    • 0026534679 scopus 로고
    • Sensitive detection of pesticides using amperometric sensors based on cobalt phthalocyanine-modified composite electrodes and immobilised cholinesterase
    • P. Skladal, and M. Mascini Sensitive detection of pesticides using amperometric sensors based on cobalt phthalocyanine-modified composite electrodes and immobilised cholinesterase Biosens. Bioelectron. 7 1992 335 343
    • (1992) Biosens. Bioelectron. , vol.7 , pp. 335-343
    • Skladal, P.1    Mascini, M.2
  • 33
    • 0021857185 scopus 로고
    • Immobilised enzyme probes for determining inhibitors
    • C. Tran-Minh Immobilised enzyme probes for determining inhibitors. Ion-Selective Electrode Rev. 7 1 1985 41 75
    • (1985) Ion-Selective Electrode Rev. , vol.7 , Issue.1 , pp. 41-75
    • Tran-Minh, C.1
  • 34
    • 8844287576 scopus 로고    scopus 로고
    • Acetylcholinesterase-based biosensor electrodes for organophosphate pesticide detection. II. Immobilisation and stabilisation of acetylcholinesterase
    • doi:10.1016/j.bios.2004.07.022
    • Vakurov, A., Simpson, C.E., Daly, C.L., Gibson, T.D., Millner, P.A., 2004. Acetylcholinesterase-based biosensor electrodes for organophosphate pesticide detection. II. Immobilisation and stabilisation of acetylcholinesterase. Biosens. Bioelectron., doi:10.1016/j.bios.2004.07.022.
    • (2004) Biosens. Bioelectron.
    • Vakurov, A.1    Simpson, C.E.2    Daly, C.L.3    Gibson, T.D.4    Millner, P.A.5
  • 35
    • 0001727689 scopus 로고
    • Voltammetry with microscopic electrodes in new domains
    • R.M. Whightman Voltammetry with microscopic electrodes in new domains Science 240 1988 415 420
    • (1988) Science , vol.240 , pp. 415-420
    • Whightman, R.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.