메뉴 건너뛰기




Volumn 108, Issue 40, 2011, Pages 16539-16544

Noninvasive and localized neuronal delivery using short ultrasonic pulses and microbubbles

Author keywords

[No Author keywords available]

Indexed keywords

DEXTRAN;

EID: 80053639355     PISSN: 00278424     EISSN: 10916490     Source Type: Journal    
DOI: 10.1073/pnas.1105116108     Document Type: Article
Times cited : (126)

References (27)
  • 1
    • 33845675648 scopus 로고    scopus 로고
    • Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice
    • DOI 10.1016/j.ultrasmedbio.2006.07.018, PII S0301562906017467
    • Choi JJ, Pernot M, Small SA, Konofagou EE (2007) Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice. Ultrasound Med Biol 33:95-104. (Pubitemid 44959316)
    • (2007) Ultrasound in Medicine and Biology , vol.33 , Issue.1 , pp. 95-104
    • Choi, J.J.1    Pernot, M.2    Small, S.A.3    Konofagou, E.E.4
  • 2
    • 0034876083 scopus 로고    scopus 로고
    • Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits
    • Hynynen K, McDannold N, Vykhodtseva N, Jolesz FA (2001) Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits. Radiology 220:640-646. (Pubitemid 32799969)
    • (2001) Radiology , vol.220 , Issue.3 , pp. 640-646
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.A.4
  • 3
    • 77956285915 scopus 로고    scopus 로고
    • Quantitative and qualitative investigation into the impact of focused ultrasound with microbubbles on the triggered release of nanoparticles from vasculature in mouse tumors
    • Lin CY, et al. (2010) Quantitative and qualitative investigation into the impact of focused ultrasound with microbubbles on the triggered release of nanoparticles from vasculature in mouse tumors. J Control Release 146:291-298.
    • (2010) J Control Release , vol.146 , pp. 291-298
    • Lin, C.Y.1
  • 4
    • 44149103793 scopus 로고    scopus 로고
    • Ultrasonic gene and drug delivery to the cardiovascular system
    • Mayer CR, Bekeredjian R (2008) Ultrasonic gene and drug delivery to the cardiovascular system. Adv Drug Deliv Rev 60:1177-1192.
    • (2008) Adv Drug Deliv Rev , vol.60 , pp. 1177-1192
    • Mayer, C.R.1    Bekeredjian, R.2
  • 5
    • 73949134550 scopus 로고    scopus 로고
    • Renal ultrafiltration changes induced by focused US
    • Fischer K, et al. (2009) Renal ultrafiltration changes induced by focused US. Radiology 253:697-705.
    • (2009) Radiology , vol.253 , pp. 697-705
    • Fischer, K.1
  • 6
    • 0031042962 scopus 로고    scopus 로고
    • Sonic effervescence: A tutorial on acoustic cavitation
    • Apfel RE (1997) Sonic effervescence: A tutorial on acoustic cavitation. J Acoust Soc Am 101:1227-1237.
    • (1997) J Acoust Soc Am , vol.101 , pp. 1227-1237
    • Apfel, R.E.1
  • 7
    • 33846438234 scopus 로고    scopus 로고
    • Multiphoton imaging of ultrasound/Optison mediated cerebrovascular effects in vivo
    • DOI 10.1038/sj.jcbfm.9600336, PII 9600336
    • Raymond SB, Skoch J, Hynynen K, Bacskai BJ (2007) Multiphoton imaging of ultrasound/Optison mediated cerebrovascular effects in vivo. J Cereb Blood Flow Metab 27:393-403. (Pubitemid 46148465)
    • (2007) Journal of Cerebral Blood Flow and Metabolism , vol.27 , Issue.2 , pp. 393-403
    • Raymond, S.B.1    Skoch, J.2    Hynynen, K.3    Bacskai, B.J.4
  • 9
    • 76649113997 scopus 로고    scopus 로고
    • Microbubble-size dependence of focused ultrasound-induced blood-brain barrier opening in mice in vivo
    • Choi JJ, et al. (2010) Microbubble-size dependence of focused ultrasound-induced blood-brain barrier opening in mice in vivo. IEEE Trans Biomed Eng 57:145-154.
    • (2010) IEEE Trans Biomed Eng , vol.57 , pp. 145-154
    • Choi, J.J.1
  • 10
    • 68949131105 scopus 로고    scopus 로고
    • An ex vivo study of the correlation between acoustic emission and microvascular damage
    • Samuel S, Cooper MA, Bull JL, Fowlkes JB, Miller DL (2009) An ex vivo study of the correlation between acoustic emission and microvascular damage. Ultrasound Med Biol 35:1574-1586.
    • (2009) Ultrasound Med Biol , vol.35 , pp. 1574-1586
    • Samuel, S.1    Cooper, M.A.2    Bull, J.L.3    Fowlkes, J.B.4    Miller, D.L.5
  • 11
    • 77956023302 scopus 로고    scopus 로고
    • Multi-modality safety assessment of blood-brain barrier opening using focused ultrasound and definity microbubbles: A short-term study
    • Baseri B, Choi JJ, Tung YS, Konofagou EE (2010) Multi-modality safety assessment of blood-brain barrier opening using focused ultrasound and definity microbubbles: A short-term study. Ultrasound Med Biol 36:1445-1459.
    • (2010) Ultrasound Med Biol , vol.36 , pp. 1445-1459
    • Baseri, B.1    Choi, J.J.2    Tung, Y.S.3    Konofagou, E.E.4
  • 12
    • 0034730121 scopus 로고    scopus 로고
    • Diagnostic ultrasound activation of contrast agent gas bodies induces capillary rupture in mice
    • Miller DL, Quddus J (2000) Diagnostic ultrasound activation of contrast agent gas bodies induces capillary rupture in mice. Proc Natl Acad Sci USA 97:10179-10184.
    • (2000) Proc Natl Acad Sci USA , vol.97 , pp. 10179-10184
    • Miller, D.L.1    Quddus, J.2
  • 14
    • 35848934576 scopus 로고    scopus 로고
    • Spatio-temporal analysis of molecular delivery through the blood-brain barrier using focused ultrasound
    • DOI 10.1088/0031-9155/52/18/004, PII S0031915507441641
    • Choi JJ, Pernot M, Brown TR, Small SA, Konofagou EE (2007) Spatio-temporal analysis of molecular delivery through the blood-brain barrier using focused ultrasound. Phys Med Biol 52:5509-5530. (Pubitemid 350056681)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.18 , pp. 5509-5530
    • Choi, J.J.1    Pernot, M.2    Brown, T.R.3    Small, S.A.4    Konofagou, E.E.5
  • 15
    • 42949140276 scopus 로고    scopus 로고
    • Blood-Brain Barrier Disruption Induced by Focused Ultrasound and Circulating Preformed Microbubbles Appears to Be Characterized by the Mechanical Index
    • DOI 10.1016/j.ultrasmedbio.2007.10.016, PII S0301562907005480
    • McDannold N, Vykhodtseva N, Hynynen K (2008) Blood-brain barrier disruption induced by focused ultrasound and circulating preformed microbubbles appears to be characterized by the mechanical index. Ultrasound Med Biol 34:834-840. (Pubitemid 351608039)
    • (2008) Ultrasound in Medicine and Biology , vol.34 , Issue.5 , pp. 834-840
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 16
    • 79551632443 scopus 로고    scopus 로고
    • Noninvasive and localized blood-brain barrier disruption using focused ultrasound can be achieved at short pulse lengths and low pulse repetition frequencies
    • Choi JJ, et al. (2011) Noninvasive and localized blood-brain barrier disruption using focused ultrasound can be achieved at short pulse lengths and low pulse repetition frequencies. J Cereb Blood Flow Metab 31:725-737.
    • (2011) J Cereb Blood Flow Metab , vol.31 , pp. 725-737
    • Choi, J.J.1
  • 17
    • 71849102712 scopus 로고    scopus 로고
    • Molecules of various pharmacologically-relevant sizes can cross the ultrasound-induced blood-brain barrier opening in vivo
    • Choi JJ, Wang S, Tung YS, Morrison B, 3rd, Konofagou EE (2010) Molecules of various pharmacologically-relevant sizes can cross the ultrasound-induced blood-brain barrier opening in vivo. Ultrasound Med Biol 36:58-67.
    • (2010) Ultrasound Med Biol , vol.36 , pp. 58-67
    • Choi, J.J.1    Wang, S.2    Tung, Y.S.3    Morrison III, B.4    Konofagou, E.E.5
  • 19
    • 58149265130 scopus 로고    scopus 로고
    • Noninvasive and transient blood-brain barrier opening in the hippocampus of Alzheimer's double transgenic mice using focused ultrasound
    • Choi JJ, et al. (2008) Noninvasive and transient blood-brain barrier opening in the hippocampus of Alzheimer's double transgenic mice using focused ultrasound. Ultrason Imaging 30:189-200.
    • (2008) Ultrason Imaging , vol.30 , pp. 189-200
    • Choi, J.J.1
  • 20
    • 80051704697 scopus 로고    scopus 로고
    • Permeability dependence study of the focused ultrasound-induced blood-brain barrier opening at distinct pressures and microbubble diameters using DCE-MRI
    • Vlachos F, Tung YS, Konofagou E (2011) Permeability dependence study of the focused ultrasound-induced blood-brain barrier opening at distinct pressures and microbubble diameters using DCE-MRI. Magn Reson Med 66:821-830.
    • (2011) Magn Reson Med , vol.66 , pp. 821-830
    • Vlachos, F.1    Tung, Y.S.2    Konofagou, E.3
  • 21
    • 34147197890 scopus 로고    scopus 로고
    • Enhancement of vascular permeability with low-frequency contrast-enhanced ultrasound in the chorioallantoic membrane model
    • DOI 10.1148/radiol.2431060167
    • Stieger SM, et al. (2007) Enhancement of vascular permeability with low-frequency contrast-enhanced ultrasound in the chorioallantoic membrane model. Radiology 243:112-121. (Pubitemid 46579701)
    • (2007) Radiology , vol.243 , Issue.1 , pp. 112-121
    • Stieger, S.M.1    Caskey, C.F.2    Adamson, R.H.3    Qin, S.4    Curry, F.-R.E.5    Wisner, E.R.6    Ferrara, K.W.7
  • 22
    • 77952309289 scopus 로고    scopus 로고
    • Identifying the inertial cavitation threshold and skull effects in a vessel phantom using focused ultrasound and microbubbles
    • Tung YS, Choi JJ, Baseri B, Konofagou EE (2010) Identifying the inertial cavitation threshold and skull effects in a vessel phantom using focused ultrasound and microbubbles. Ultrasound Med Biol 36:840-852.
    • (2010) Ultrasound Med Biol , vol.36 , pp. 840-852
    • Tung, Y.S.1    Choi, J.J.2    Baseri, B.3    Konofagou, E.E.4
  • 23
    • 78149317618 scopus 로고    scopus 로고
    • In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice
    • Tung YS, et al. (2010) In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice. Phys Med Biol 55:6141-6155.
    • (2010) Phys Med Biol , vol.55 , pp. 6141-6155
    • Tung, Y.S.1
  • 26
    • 0037237319 scopus 로고    scopus 로고
    • Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans
    • DOI 10.1121/1.1529663
    • Aubry JF, Tanter M, Pernot M, Thomas JL, Fink M (2003) Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans. J Acoust Soc Am 113:84-93. (Pubitemid 36105663)
    • (2003) Journal of the Acoustical Society of America , vol.113 , Issue.1 , pp. 84-93
    • Aubry, J.-F.1    Tanter, M.2    Pernot, M.3    Thomas, J.-L.4    Fink, M.5
  • 27
    • 78149308911 scopus 로고    scopus 로고
    • Numerical study of a simple transcranial focused ultrasound system applied to blood-brain barrier opening
    • Deffieux T, Konofagou EE (2010) Numerical study of a simple transcranial focused ultrasound system applied to blood-brain barrier opening. IEEE Trans Ultrason Ferroelectr Freq Control 57:2637-2653.
    • (2010) IEEE Trans Ultrason Ferroelectr Freq Control , vol.57 , pp. 2637-2653
    • Deffieux, T.1    Konofagou, E.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.