메뉴 건너뛰기




Volumn 261, Issue 1, 2011, Pages 100-108

Coronary artery stenoses: Accuracy of 64-detector row CT angiography in segments with mild, moderate, or severe calcification - A subanalysis of the CORE-64 trial

Author keywords

[No Author keywords available]

Indexed keywords

CALCIUM;

EID: 80053077385     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.11110537     Document Type: Article
Times cited : (135)

References (26)
  • 1
    • 60449094498 scopus 로고    scopus 로고
    • Heart disease and stroke statistics: 2009 update-a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee
    • Lloyd-Jones D, Adams R, Carnethon M, et al. Heart disease and stroke statistics: 2009 update-a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee . Circulation 2009;119(3):e21-e181.
    • (2009) Circulation , vol.119 , Issue.3
    • Lloyd-Jones, D.1    Adams, R.2    Carnethon, M.3
  • 2
    • 44449098165 scopus 로고    scopus 로고
    • Dual-source CT: Effect of heart rate, heart rate variability, and calcifi cation on image quality and diagnostic accuracy
    • Brodoefel H, Burgstahler C, Tsifl ikas I, et al. Dual-source CT: effect of heart rate, heart rate variability, and calcifi cation on image quality and diagnostic accuracy . Radiology 2008;247(2):346-355.
    • (2008) Radiology , vol.247 , Issue.2 , pp. 346-355
    • Brodoefel, H.1    Burgstahler, C.2    Tsiflikas, I.3
  • 3
    • 33646237121 scopus 로고    scopus 로고
    • Non-invasive half millimetre 32 detector row computed tomography angiography accurately excludes significant stenoses in patients with advanced coronary artery disease and high calcium scores
    • Cordeiro MA, Miller JM, Schmidt A, et al. Non-invasive half millimetre 32 detector row computed tomography angiography accurately excludes signifi cant stenoses in patients with advanced coronary artery disease and high calcium scores . Heart 2006;92(5):589-597.
    • (2006) Heart , vol.92 , Issue.5 , pp. 589-597
    • Cordeiro, M.A.1    Miller, J.M.2    Schmidt, A.3
  • 4
    • 36248999527 scopus 로고    scopus 로고
    • Coronary arteries: Diagnostic performance of 16- versus 64-section spiral CT compared with invasive coronary angiography - Meta-analysis
    • DOI 10.1148/radiol.2453061899
    • Hamon M, Morello R, Riddell JW, Hamon M. Coronary arteries: diagnostic performance of 16- versus 64-section spiral CT compared with invasive coronary angiography-metaanalysis . Radiology 2007;245(3):720-731. (Pubitemid 350127342)
    • (2007) Radiology , vol.245 , Issue.3 , pp. 720-731
    • Hamon, M.1    Morello, R.2    Riddell, J.W.3    Hamon, M.4
  • 5
    • 57449115879 scopus 로고    scopus 로고
    • Diagnostic accuracy of 64-slice computed tomography coronary angiography: A prospective, multicenter, multivendor study
    • Meijboom WB, Meijs MF, Schuijf JD, et al. Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study . J Am Coll Cardiol 2008;52(25):2135-2144.
    • (2008) J Am Coll Cardiol , vol.52 , Issue.25 , pp. 2135-2144
    • Meijboom, W.B.1    Meijs, M.F.2    Schuijf, J.D.3
  • 6
    • 57149121037 scopus 로고    scopus 로고
    • Diagnostic performance of coronary angiography by 64-row CT
    • Miller JM, Rochitte CE, Dewey M, et al. Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med 2008;359(22:2324-2336.
    • (2008) N Engl J Med , vol.359 , Issue.22 , pp. 2324-2336
    • Miller, J.M.1    Rochitte, C.E.2    Dewey, M.3
  • 7
    • 22844448174 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography
    • DOI 10.1016/j.jacc.2005.05.056, PII S0735109705013148
    • Raff GL, Gallagher MJ, O'Neill WW, Goldstein JA. Diagnostic accuracy of noninvasive coro nary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 2005;46(3):552-557. (Pubitemid 41040301)
    • (2005) Journal of the American College of Cardiology , vol.46 , Issue.3 , pp. 552-557
    • Raff, G.L.1    Gallagher, M.J.2    O'Neill, W.W.3    Goldstein, J.A.4
  • 8
    • 74749099540 scopus 로고    scopus 로고
    • Patient characteristics as predictors of image quality and diagnostic accuracy of MDCT compared with conventional coronary angiography for detecting coronary artery stenoses: CORE-64 multicenter international trial
    • Dewey M, Vavere AL, Arbab-Zadeh A, et al. Patient characteristics as predictors of image quality and diagnostic accuracy of MDCT compared with conventional coronary angiography for detecting coronary artery stenoses: CORE-64 multicenter international trial. AJR Am J Roentgenol 2010;194(1):93-102.
    • (2010) AJR Am J Roentgenol , vol.194 , Issue.1 , pp. 93-102
    • Dewey, M.1    Vavere, A.L.2    Arbab-Zadeh, A.3
  • 9
    • 54549122949 scopus 로고    scopus 로고
    • Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: Results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial
    • Budoff MJ, Dowe D, Jollis JG, et al. Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial. J Am Coll Cardiol 2008;52(21):1724-1732.
    • (2008) J Am Coll Cardiol , vol.52 , Issue.21 , pp. 1724-1732
    • Budoff, M.J.1    Dowe, D.2    Jollis, J.G.3
  • 11
    • 37149045276 scopus 로고    scopus 로고
    • Non-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease: The Coronary Angiography by Computed Tomography with the Use of a Submillimeter resolution (CACTUS) trial
    • DOI 10.1093/eurheartj/ehm150
    • Hausleiter J, Meyer T, Hadamitzky M, et al. Non-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease: the Coronary Angiography by Computed Tomography with the Use of a Submillimeter Resolution (CACTUS) trial. Eur Heart J 2007;28(24):3034-3041. (Pubitemid 350262249)
    • (2007) European Heart Journal , vol.28 , Issue.24 , pp. 3034-3041
    • Hausleiter, J.1    Meyer, T.2    Hadamitzky, M.3    Zankl, M.4    Gerein, P.5    Dorrler, K.6    Kastrati, A.7    Martinoff, S.8    Schomig, A.9
  • 12
    • 39549099086 scopus 로고    scopus 로고
    • Diagnostic performance of coronary CT angiography by using different generations of multisection scanners: Single-center experience
    • Pugliese F, Mollet NR, Hunink MG, et al. Diagnostic performance of coronary CT angiography by using different generations of multisection scanners: single-center experience. Radiology 2008;246(2):384-393.
    • (2008) Radiology , vol.246 , Issue.2 , pp. 384-393
    • Pugliese, F.1    Mollet, N.R.2    Hunink, M.G.3
  • 13
    • 33744967019 scopus 로고    scopus 로고
    • Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: Infl uence of calcification
    • Ong TK, Chin SP, Liew CK, et al. Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: infl uence of calcification. Am Heart J 2006;151(6):1323.e1-1323.e6.
    • (2006) Am Heart J , vol.151 , Issue.6
    • Ong, T.K.1    Chin, S.P.2    Liew, C.K.3
  • 14
    • 67650468873 scopus 로고    scopus 로고
    • Effect of heart rate and coronary calcifi cation on the diagnostic accuracy of the dual-source CT coronary angiography in patients with suspected coronary artery disease
    • Meng L, Cui L, Cheng Y, et al. Effect of heart rate and coronary calcifi cation on the diagnostic accuracy of the dual-source CT coronary angiography in patients with suspected coronary artery disease. Korean J Radiol 2009;10(4):347-354.
    • (2009) Korean J Radiol , vol.10 , Issue.4 , pp. 347-354
    • Meng, L.1    Cui, L.2    Cheng, Y.3
  • 15
    • 76449094887 scopus 로고    scopus 로고
    • The absence of coronary calcifi cation does not exclude obstructive coronary artery disease or the need for revascularization in patients referred for conventional coronary angiography
    • Gottlieb I, Miller JM, Arbab-Zadeh A, et al. The absence of coronary calcifi cation does not exclude obstructive coronary artery disease or the need for revascularization in patients referred for conventional coronary angiography. J Am Coll Cardiol 2010;55(7):627-634.
    • (2010) J Am Coll Cardiol , vol.55 , Issue.7 , pp. 627-634
    • Gottlieb, I.1    Miller, J.M.2    Arbab-Zadeh, A.3
  • 16
    • 62649110273 scopus 로고    scopus 로고
    • Coronary CT angiography using 64 detector rows: Methods and design of the multi-centre trial CORE-64
    • Miller JM, Dewey M, Vavere AL, et al. Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64 . Eur Radiol 2009;19(4):816-828.
    • (2009) Eur Radiol , vol.19 , Issue.4 , pp. 816-828
    • Miller, J.M.1    Dewey, M.2    Vavere, A.L.3
  • 17
    • 1642351485 scopus 로고    scopus 로고
    • Multisegment and Halfscan Reconstruction of 16-Slice Computed Tomography for Detection of Coronary Artery Stenoses
    • DOI 10.1097/01.rli.0000115201.27096.6e
    • Dewey M, Laule M, Krug L, et al. Multisegment and halfscan reconstruction of 16- slice computed tomography for detection of coronary artery stenoses. Invest Radiol 2004;39(4):223-229. (Pubitemid 38391787)
    • (2004) Investigative Radiology , vol.39 , Issue.4 , pp. 223-229
    • Dewey, M.1    Laule, M.2    Krug, L.3    Schnapauff, D.4    Rogalla, P.5    Rutsch, W.6    Hamm, B.7    Lembcke, A.8
  • 18
    • 0028905580 scopus 로고
    • Patterns of calcifi cation in coronary artery disease: A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions
    • Mintz GS, Popma JJ, Pichard AD, et al. Patterns of calcifi cation in coronary artery disease: a statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions. Circulation 1995;91(7):1959-1965.
    • (1995) Circulation , vol.91 , Issue.7 , pp. 1959-1965
    • Mintz, G.S.1    Popma, J.J.2    Pichard, A.D.3
  • 20
    • 33846894344 scopus 로고    scopus 로고
    • Receiver-operating characteristic analysis for evaluating diagnostic tests and predictive models
    • DOI 10.1161/CIRCULATIONAHA.105.594929, PII 0000301720070206000016
    • Zou KH, O'Malley AJ, Mauri L. Receiveroperating characteristic analysis for evaluating diagnostic tests and predictive models. Circulation 2007;115(5):654-657. (Pubitemid 46226175)
    • (2007) Circulation , vol.115 , Issue.5 , pp. 654-657
    • Zou, K.H.1    O'Malley, A.J.2    Mauri, L.3
  • 22
    • 57149118092 scopus 로고    scopus 로고
    • Accuracy of MDCT in assessing the degree of stenosis caused by calcifi ed coronary artery plaques
    • Zhang S, Levin DC, Halpern EJ, Fischman D, Savage M, Walinsky P. Accuracy of MDCT in assessing the degree of stenosis caused by calcifi ed coronary artery plaques. AJR Am J Roentgenol 2008;191(6):1676-1683.
    • (2008) AJR Am J Roentgenol , vol.191 , Issue.6 , pp. 1676-1683
    • Zhang, S.1    Levin, D.C.2    Halpern, E.J.3    Fischman, D.4    Savage, M.5    Walinsky, P.6
  • 23
    • 79952398815 scopus 로고    scopus 로고
    • Coronary CT versus MR angiography: Pro CT-the role of CT angiography
    • Dewey M . Coronary CT versus MR angiography: pro CT-the role of CT angiography. Radiology 2011;258(2):329-339.
    • (2011) Radiology , vol.258 , Issue.2 , pp. 329-339
    • Dewey, M.1
  • 24
    • 77953935506 scopus 로고    scopus 로고
    • Characterization and correction of beam-hardening artifacts during dynamic volume CT assessment of myocardial perfusion
    • Kitagawa K, George RT, Arbab-Zadeh A, Lima JA, Lardo AC. Characterization and correction of beam-hardening artifacts during dynamic volume CT assessment of myocardial perfusion. Radiology 2010;256(1):111-118.
    • (2010) Radiology , vol.256 , Issue.1 , pp. 111-118
    • Kitagawa, K.1    George, R.T.2    Arbab-Zadeh, A.3    Lima, J.A.4    Lardo, A.C.5
  • 25
    • 79251557813 scopus 로고    scopus 로고
    • Evaluation of severely calcifi ed coronary artery using fast-switching dual-kVp 64-slice computed tomography
    • Yamada M, Jinzaki M, Imai Y, et al. Evaluation of severely calcifi ed coronary artery using fast-switching dual-kVp 64-slice computed tomography. Circ J 2011;75(2):472-473.
    • (2011) Circ J , vol.75 , Issue.2 , pp. 472-473
    • Yamada, M.1    Jinzaki, M.2    Imai, Y.3
  • 26
    • 84861482335 scopus 로고    scopus 로고
    • Improvement of in-stent lumen measurement accuracy with new High-Defi nition CT in a phantom model: Comparison with conventional 64-detector row CT
    • doi:10. 1007/s10554-010-9786-x. Published online January 8, Accessed May 11, 2011
    • Tanami Y, Jinzaki M, Yamada M, Imai Y, Segawa K, Kuribayashi S. Improvement of in-stent lumen measurement accuracy with new High-Defi nition CT in a phantom model: comparison with conventional 64-detector row CT. Int J Cardiovasc Imaging doi:10. 1007/s10554-010-9786-x. Published online January 8, 2011. Accessed May 11, 2011.
    • (2011) Int J Cardiovasc Imaging
    • Tanami, Y.1    Jinzaki, M.2    Yamada, M.3    Imai, Y.4    Segawa, K.5    Kuribayashi, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.