메뉴 건너뛰기




Volumn 19, Issue 10, 2011, Pages 1749-1754

Tendon-grasping strength of various suture configurations for rotator cuff repair

Author keywords

Double mattress stitch; Lasso loop; Mason Allen; Rotator cuff repair

Indexed keywords


EID: 80052870740     PISSN: 09422056     EISSN: 14337347     Source Type: Journal    
DOI: 10.1007/s00167-010-1322-y     Document Type: Article
Times cited : (16)

References (34)
  • 1
    • 33747044407 scopus 로고    scopus 로고
    • Comparative study of different tendon grasping techniques for arthroscopic repair of the rotator cuff
    • Baleani M, Ohman C, Guandalini L, Rotini R, Giavaresi G, Traina F et al (2006) Comparative study of different tendon grasping techniques for arthroscopic repair of the rotator cuff. Clin Biomech 8: 799-803.
    • (2006) Clin Biomech , vol.8 , pp. 799-803
    • Baleani, M.1    Ohman, C.2    Guandalini, L.3    Rotini, R.4    Giavaresi, G.5    Traina, F.6
  • 2
    • 0041736605 scopus 로고    scopus 로고
    • Surgical repair of the rotator cuff: a biomechanical evaluation of different tendon grasping and bone suture fixation techniques
    • Baleani M, Schrader S, Veronesi CA, Rotini R, Giardino R, Toni A (2003) Surgical repair of the rotator cuff: a biomechanical evaluation of different tendon grasping and bone suture fixation techniques. Clin Biomech 18: 721-729.
    • (2003) Clin Biomech , vol.18 , pp. 721-729
    • Baleani, M.1    Schrader, S.2    Veronesi, C.A.3    Rotini, R.4    Giardino, R.5    Toni, A.6
  • 3
    • 58549109431 scopus 로고    scopus 로고
    • Cyclic load and failure behavior of arthroscopic knots and high strength sutures
    • Barber FA, Herbert MA, Beavis RC (2009) Cyclic load and failure behavior of arthroscopic knots and high strength sutures. Arthroscopy 25: 192-199.
    • (2009) Arthroscopy , vol.25 , pp. 192-199
    • Barber, F.A.1    Herbert, M.A.2    Beavis, R.C.3
  • 4
    • 55349146237 scopus 로고    scopus 로고
    • Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material
    • Baums MH, Buchhorn GH, Spahn G, Poppendieck B, Schultz W, Klinger HM (2008) Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material. Knee Surg Sports Traumatol Arthrosc 11: 1052-1060.
    • (2008) Knee Surg Sports Traumatol Arthrosc , vol.11 , pp. 1052-1060
    • Baums, M.H.1    Buchhorn, G.H.2    Spahn, G.3    Poppendieck, B.4    Schultz, W.5    Klinger, H.M.6
  • 5
    • 42249109213 scopus 로고    scopus 로고
    • Influence of suture material on the biomechanical behavior of suture-tendon specimens: a controlled study in bovine rotator cuff
    • Bisson LJ, Manohar LM, Wilkins RD, Gurske-Deperio J, Ehrensberger MT (2008) Influence of suture material on the biomechanical behavior of suture-tendon specimens: a controlled study in bovine rotator cuff. Am J Sports Med 36: 907-912.
    • (2008) Am J Sports Med , vol.36 , pp. 907-912
    • Bisson, L.J.1    Manohar, L.M.2    Wilkins, R.D.3    Gurske-Deperio, J.4    Ehrensberger, M.T.5
  • 6
    • 33645017933 scopus 로고    scopus 로고
    • Comparative and experimental study on different tendinous grasping techniques in rotator cuff repair: a new reinforced stitch
    • Bungaro P, Rotini R, Traina F, Baleani M, Antonioli D, Fini M, Castagna A (2005) Comparative and experimental study on different tendinous grasping techniques in rotator cuff repair: a new reinforced stitch. Chir Organi Mov 2: 113-119.
    • (2005) Chir Organi Mov , vol.2 , pp. 113-119
    • Bungaro, P.1    Rotini, R.2    Traina, F.3    Baleani, M.4    Antonioli, D.5    Fini, M.6    Castagna, A.7
  • 7
    • 0035526413 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair. Analysis of results by tear size and by repair technique-margin convergence versus direct tendon-to-bone repair
    • Burkhart SS, Danaceau SM, Pearce CE Jr (2001) Arthroscopic rotator cuff repair. Analysis of results by tear size and by repair technique-margin convergence versus direct tendon-to-bone repair. Arthroscopy 17: 905-912.
    • (2001) Arthroscopy , vol.17 , pp. 905-912
    • Burkhart, S.S.1    Danaceau, S.M.2    Pearce Jr., C.E.3
  • 9
    • 34047242088 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair using a triple loaded suture anchor and a modified Mason-Allen technique
    • Castagna A, Garofalo R, Conti M, Borroni M, Snyder SJ (2007) Arthroscopic rotator cuff repair using a triple loaded suture anchor and a modified Mason-Allen technique. Arthroscopy 4: 440e1-440e4.
    • (2007) Arthroscopy , vol.4
    • Castagna, A.1    Garofalo, R.2    Conti, M.3    Borroni, M.4    Snyder, S.J.5
  • 10
    • 0037492958 scopus 로고    scopus 로고
    • Mode of failure for rotator cuff repair with suture anchors identified at revision surgery
    • Cummins CA, Murrell GA (2003) Mode of failure for rotator cuff repair with suture anchors identified at revision surgery. J Shoulder Elbow Surg 12: 128-133.
    • (2003) J Shoulder Elbow Surg , vol.12 , pp. 128-133
    • Cummins, C.A.1    Murrell, G.A.2
  • 11
    • 0031808081 scopus 로고    scopus 로고
    • Arthroscopic repair of full-thickness tears of the rotator cuff
    • Gartsman GM, Khan M, Hammerman SM (1998) Arthroscopic repair of full-thickness tears of the rotator cuff. J Bone Joint Surg Am 80: 832-840.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 832-840
    • Gartsman, G.M.1    Khan, M.2    Hammerman, S.M.3
  • 12
    • 0034087111 scopus 로고    scopus 로고
    • The results of repair of massive tears of the rotator cuff
    • Gerber C, Fuchs B, Hodler J (2000) The results of repair of massive tears of the rotator cuff. J Bone Joint Surg Am 82: 505-515.
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 505-515
    • Gerber, C.1    Fuchs, B.2    Hodler, J.3
  • 16
    • 39149099170 scopus 로고    scopus 로고
    • Biomechanical evaluation of rotator cuff repairs in a sheep model: Suture anchors using arthroscopic Mason-Allen stitches compared with transosseous sutures using traditional modified Mason-Allen stitches
    • Klinger HM, Buchhorn GH, Heidrich G, Kahl E, Baums MH (2008) Biomechanical evaluation of rotator cuff repairs in a sheep model: Suture anchors using arthroscopic Mason-Allen stitches compared with transosseous sutures using traditional modified Mason-Allen stitches. Clin Biomech 3: 291-298.
    • (2008) Clin Biomech , vol.3 , pp. 291-298
    • Klinger, H.M.1    Buchhorn, G.H.2    Heidrich, G.3    Kahl, E.4    Baums, M.H.5
  • 17
    • 33845667858 scopus 로고    scopus 로고
    • Biomechanical comparison of double-loaded suture anchors using arthroscopic Mason-Allen Stitches versus traditional transosseous suture technique and modified Mason-Allen stitches for rotator cuff repair
    • Klinger HM, Steckel H, Spahn G, Buchhorn GH, Baums MH (2007) Biomechanical comparison of double-loaded suture anchors using arthroscopic Mason-Allen Stitches versus traditional transosseous suture technique and modified Mason-Allen stitches for rotator cuff repair. Clin Biomech 1: 106-111.
    • (2007) Clin Biomech , vol.1 , pp. 106-111
    • Klinger, H.M.1    Steckel, H.2    Spahn, G.3    Buchhorn, G.H.4    Baums, M.H.5
  • 19
    • 33750940583 scopus 로고    scopus 로고
    • Biomechanical comparison of traditional and locked suture configurations for arthroscopic repairs of the rotator cuff
    • Koganti AK, Adamson GJ, Gregersen CS, Pink MM, Shankwiler JA (2006) Biomechanical comparison of traditional and locked suture configurations for arthroscopic repairs of the rotator cuff. Am J Sports Med 11: 1832-1838.
    • (2006) Am J Sports Med , vol.11 , pp. 1832-1838
    • Koganti, A.K.1    Adamson, G.J.2    Gregersen, C.S.3    Pink, M.M.4    Shankwiler, J.A.5
  • 20
    • 33750432478 scopus 로고    scopus 로고
    • A new technique to improve tissue grip: "the lasso-loop stitch"
    • Lafosse L, van Raebroeckx A, Brzoska R (2006) A new technique to improve tissue grip: "the lasso-loop stitch". Arthroscopy 11: 1246e1-1246e3.
    • (2006) Arthroscopy , vol.11
    • Lafosse, L.1    van Raebroeckx, A.2    Brzoska, R.3
  • 21
    • 77956392361 scopus 로고    scopus 로고
    • Three-dimensional evaluation of the cyclic loading behavior of different rotator cuff reconstructions
    • Lorbach O, Anagnostakos K, Vees J, Kohn D, Pape D (2010) Three-dimensional evaluation of the cyclic loading behavior of different rotator cuff reconstructions. Arthroscopy 9(Suppl): 95-105.
    • (2010) Arthroscopy , vol.9 , Issue.SUPPL. , pp. 95-105
    • Lorbach, O.1    Anagnostakos, K.2    Vees, J.3    Kohn, D.4    Pape, D.5
  • 22
    • 47649097837 scopus 로고    scopus 로고
    • Cyclic loading of rotator cuff reconstructions: single-row repair with modified suture configurations versus double-row repair
    • Lorbach O, Bachelier F, Vees J, Kohn D, Pape D (2008) Cyclic loading of rotator cuff reconstructions: single-row repair with modified suture configurations versus double-row repair. Am J Sports Med 36: 1504-1510.
    • (2008) Am J Sports Med , vol.36 , pp. 1504-1510
    • Lorbach, O.1    Bachelier, F.2    Vees, J.3    Kohn, D.4    Pape, D.5
  • 24
    • 36549000239 scopus 로고    scopus 로고
    • Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model
    • Mahar A, Tamborlane J, Oka R, Esch J, Pedowitz RA (2007) Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model. Arthroscopy 12: 1265-1270.
    • (2007) Arthroscopy , vol.12 , pp. 1265-1270
    • Mahar, A.1    Tamborlane, J.2    Oka, R.3    Esch, J.4    Pedowitz, R.A.5
  • 26
    • 0036357088 scopus 로고    scopus 로고
    • Arthroscopic repair of medium to large full-thickness rotator cuff tears: outcome at 2- to 6-year follow-up
    • Murray TF Jr, Lajtai G, Mileski RM, Snyder SJ (2002) Arthroscopic repair of medium to large full-thickness rotator cuff tears: outcome at 2- to 6-year follow-up. J Shoulder Elbow Surg 11: 19-24.
    • (2002) J Shoulder Elbow Surg , vol.11 , pp. 19-24
    • Murray Jr., T.F.1    Lajtai, G.2    Mileski, R.M.3    Snyder, S.J.4
  • 27
    • 0029879091 scopus 로고    scopus 로고
    • MR imaging of the rotator cuff: peritendinous and bone abnormalities in an asymptomatic population
    • Needell SD, Zlatkin MB, Sher JS, Murphy BJ, Uribe JW (1996) MR imaging of the rotator cuff: peritendinous and bone abnormalities in an asymptomatic population. AJR Am J Roentgenol 166: 863-867.
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 863-867
    • Needell, S.D.1    Zlatkin, M.B.2    Sher, J.S.3    Murphy, B.J.4    Uribe, J.W.5
  • 28
    • 47649124821 scopus 로고    scopus 로고
    • Single-row modified mason-allen versus double-row arthroscopic rotator cuff repair: a biomechanical and surface area comparison
    • Nelson CO, Sileo MJ, Grossman MG, Serra-Hsu F (2008) Single-row modified mason-allen versus double-row arthroscopic rotator cuff repair: a biomechanical and surface area comparison. Arthroscopy 8: 941-948.
    • (2008) Arthroscopy , vol.8 , pp. 941-948
    • Nelson, C.O.1    Sileo, M.J.2    Grossman, M.G.3    Serra-Hsu, F.4
  • 29
    • 33846229252 scopus 로고    scopus 로고
    • An in vivo comparison of the modified Mason-Allen suture technique versus an inclined horizontal mattress suture technique with regard to tendon-to-bone healing: a biomechanical and histologic study in sheep
    • Schlegel TF, Hawkins RJ, Lewis CW, Turner AS (2007) An in vivo comparison of the modified Mason-Allen suture technique versus an inclined horizontal mattress suture technique with regard to tendon-to-bone healing: a biomechanical and histologic study in sheep. J Shoulder Elbow Surg 16: 115-121.
    • (2007) J Shoulder Elbow Surg , vol.16 , pp. 115-121
    • Schlegel, T.F.1    Hawkins, R.J.2    Lewis, C.W.3    Turner, A.S.4
  • 30
    • 33847363106 scopus 로고    scopus 로고
    • A biomechanical comparison of the modified Mason-Allen stitch and massive cuff stitch in vitro
    • Sileo MJ, Ruotolo CR, Nelson CO, Serra-Hsu F, Panchal AP (2007) A biomechanical comparison of the modified Mason-Allen stitch and massive cuff stitch in vitro. Arthroscopy 3: 235-240.
    • (2007) Arthroscopy , vol.3 , pp. 235-240
    • Sileo, M.J.1    Ruotolo, C.R.2    Nelson, C.O.3    Serra-Hsu, F.4    Panchal, A.P.5
  • 31
    • 67349281418 scopus 로고    scopus 로고
    • A new approach to improving the tissue grip of the medial-row repair in the suture-bridge technique: the Modified Lasso-Loop Stitch
    • Toussaint B, Schnaser E, Lafosse L, Bahurel J, Gobezie R (2009) A new approach to improving the tissue grip of the medial-row repair in the suture-bridge technique: the Modified Lasso-Loop Stitch. Arthroscopy 6: 691-695.
    • (2009) Arthroscopy , vol.6 , pp. 691-695
    • Toussaint, B.1    Schnaser, E.2    Lafosse, L.3    Bahurel, J.4    Gobezie, R.5
  • 32
    • 33746805425 scopus 로고    scopus 로고
    • The strength of suture configurations in arthroscopic rotator cuff repair
    • White CD, Bunker TD, Hooper RM (2006) The strength of suture configurations in arthroscopic rotator cuff repair. Arthroscopy 8: 837-841.
    • (2006) Arthroscopy , vol.8 , pp. 837-841
    • White, C.D.1    Bunker, T.D.2    Hooper, R.M.3
  • 33
    • 0036488171 scopus 로고    scopus 로고
    • Arthroscopic repair of full-thickness tears of the rotator cuff: 2- to 14-year follow-up
    • Wilson F, Hinov V, Adams G (2002) Arthroscopic repair of full-thickness tears of the rotator cuff: 2- to 14-year follow-up. Arthroscopy 18: 136-144.
    • (2002) Arthroscopy , vol.18 , pp. 136-144
    • Wilson, F.1    Hinov, V.2    Adams, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.