메뉴 건너뛰기




Volumn 21, Issue 8, 2006, Pages 799-803

Comparative study of different tendon grasping techniques for arthroscopic repair of the rotator cuff

Author keywords

Biomechanics; Experimental testing; Repair technique; Rotator cuff; Tensile strength

Indexed keywords

EXPERIMENTAL TESTING; REPAIR TECHNIQUES; ROTATOR CUFF;

EID: 33747044407     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2006.04.011     Document Type: Article
Times cited : (34)

References (29)
  • 1
    • 0041736605 scopus 로고    scopus 로고
    • Surgical repair of the rotator cuff: a biomechanical evaluation of different tendon grasping and bone suture fixation techniques
    • Baleani M., Schrader S., Veronesi C.A., Rotini R., Giardino R., and Toni A. Surgical repair of the rotator cuff: a biomechanical evaluation of different tendon grasping and bone suture fixation techniques. Clin. Biomech. 18 (2003) 721-729
    • (2003) Clin. Biomech. , vol.18 , pp. 721-729
    • Baleani, M.1    Schrader, S.2    Veronesi, C.A.3    Rotini, R.4    Giardino, R.5    Toni, A.6
  • 2
    • 22144437280 scopus 로고    scopus 로고
    • Cyclic loading of rotator cuff repairs: an in vitro biomechanical comparison of bioabsorbable tacks with transosseous sutures
    • Bicknell R.T., Harwood C., Ferreira L., King G.J., Johnson J.A., Faber K., et al. Cyclic loading of rotator cuff repairs: an in vitro biomechanical comparison of bioabsorbable tacks with transosseous sutures. Arthroscopy 21 (2005) 875-880
    • (2005) Arthroscopy , vol.21 , pp. 875-880
    • Bicknell, R.T.1    Harwood, C.2    Ferreira, L.3    King, G.J.4    Johnson, J.A.5    Faber, K.6
  • 3
    • 19044374049 scopus 로고    scopus 로고
    • Open versus arthroscopic rotator cuff repair: a comparative view of 96 cases
    • Buess E., Steuber K.U., and Waibl B. Open versus arthroscopic rotator cuff repair: a comparative view of 96 cases. Arthroscopy 21 (2005) 597-604
    • (2005) Arthroscopy , vol.21 , pp. 597-604
    • Buess, E.1    Steuber, K.U.2    Waibl, B.3
  • 4
    • 33645017933 scopus 로고    scopus 로고
    • Comparative and experimental study on different tendinous grasping techniques in rotator cuff repair: a new reinforced stitch
    • Bungaro P., Rotini R., Traina F., Baleani M., Antonioli D., Fini M., et al. Comparative and experimental study on different tendinous grasping techniques in rotator cuff repair: a new reinforced stitch. Chir. Organi. Mov. 90 (2005) 113-119
    • (2005) Chir. Organi. Mov. , vol.90 , pp. 113-119
    • Bungaro, P.1    Rotini, R.2    Traina, F.3    Baleani, M.4    Antonioli, D.5    Fini, M.6
  • 5
    • 0030900130 scopus 로고    scopus 로고
    • Cyclic loading of transosseous rotator cuff repairs: tension overload as a possible cause of failure
    • Burkhart S.S., Johnson T.C., Wirth M.A., and Athanasiou K.A. Cyclic loading of transosseous rotator cuff repairs: tension overload as a possible cause of failure. Arthroscopy 13 (1997) 172-176
    • (1997) Arthroscopy , vol.13 , pp. 172-176
    • Burkhart, S.S.1    Johnson, T.C.2    Wirth, M.A.3    Athanasiou, K.A.4
  • 7
    • 0035526413 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair: analysis of results by tear size and by repair technique-margin convergence versus direct tendon-to-bone repair
    • Burkhart S.S., Danaceau S.M., and Pearce Jr. C.E. Arthroscopic rotator cuff repair: analysis of results by tear size and by repair technique-margin convergence versus direct tendon-to-bone repair. Arthroscopy 17 (2001) 905-912
    • (2001) Arthroscopy , vol.17 , pp. 905-912
    • Burkhart, S.S.1    Danaceau, S.M.2    Pearce Jr., C.E.3
  • 8
    • 0037492958 scopus 로고    scopus 로고
    • Mode of failure for rotator cuff repair with suture anchors identified at revision surgery
    • Cummins C.A., and Murrell G.A. Mode of failure for rotator cuff repair with suture anchors identified at revision surgery. J. Shoulder Elb. Surg. 12 (2003) 128-133
    • (2003) J. Shoulder Elb. Surg. , vol.12 , pp. 128-133
    • Cummins, C.A.1    Murrell, G.A.2
  • 9
    • 0031935488 scopus 로고    scopus 로고
    • Early effectiveness of arthroscopic repair for full-thickness tears of the rotator cuff: an outcome analysis
    • Gartsman G.M., Brinker M.R., and Khan M. Early effectiveness of arthroscopic repair for full-thickness tears of the rotator cuff: an outcome analysis. J. Bone Joint Surg. Am. 80 (1998) 33-40
    • (1998) J. Bone Joint Surg. Am. , vol.80 , pp. 33-40
    • Gartsman, G.M.1    Brinker, M.R.2    Khan, M.3
  • 12
    • 0034087111 scopus 로고    scopus 로고
    • The results of repair of massive tears of the rotator cuff
    • Gerber C., Fuchs B., and Hodler J. The results of repair of massive tears of the rotator cuff. J. Bone Joint Surg. Am. 82 (2000) 505-515
    • (2000) J. Bone Joint Surg. Am. , vol.82 , pp. 505-515
    • Gerber, C.1    Fuchs, B.2    Hodler, J.3
  • 16
    • 0026816612 scopus 로고
    • Towards a model for force predictions in the human shoulder
    • Karlsson D., and Peterson B. Towards a model for force predictions in the human shoulder. J. Biomech. 25 (1992) 189-199
    • (1992) J. Biomech. , vol.25 , pp. 189-199
    • Karlsson, D.1    Peterson, B.2
  • 17
    • 0035497430 scopus 로고    scopus 로고
    • Significance of the internal locking mechanism for loop security enhancement in the arthroscopic knot
    • Kim S.H., Ha K.I., and Kim J.S. Significance of the internal locking mechanism for loop security enhancement in the arthroscopic knot. Arthroscopy 17 (2001) 850-855
    • (2001) Arthroscopy , vol.17 , pp. 850-855
    • Kim, S.H.1    Ha, K.I.2    Kim, J.S.3
  • 18
  • 19
    • 0035031682 scopus 로고    scopus 로고
    • The effect of immobilization on rotator cuff healing using modified Mason-Allen stitches: a biomechanical study in sheep
    • Lewis C.W., Schlegel T.F., Hawkins R.J., James S.P., and Turner A.S. The effect of immobilization on rotator cuff healing using modified Mason-Allen stitches: a biomechanical study in sheep. Biomed. Sci. Instrum. 37 (2001) 263-268
    • (2001) Biomed. Sci. Instrum. , vol.37 , pp. 263-268
    • Lewis, C.W.1    Schlegel, T.F.2    Hawkins, R.J.3    James, S.P.4    Turner, A.S.5
  • 20
    • 2442511176 scopus 로고    scopus 로고
    • Arthroscopic knots: determining the optimal balance of loop security and knot security
    • Lo I.K., Burkhart S.S., Chan K.C., and Athanasiou K. Arthroscopic knots: determining the optimal balance of loop security and knot security. Arthroscopy 20 (2004) 489-502
    • (2004) Arthroscopy , vol.20 , pp. 489-502
    • Lo, I.K.1    Burkhart, S.S.2    Chan, K.C.3    Athanasiou, K.4
  • 23
    • 31844453610 scopus 로고    scopus 로고
    • Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation
    • Ma C.B., Comerford L., Wilson J., and Puttlitz C.M. Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation. J. Bone Joint Surg. Am. 88 (2006) 403-410
    • (2006) J. Bone Joint Surg. Am. , vol.88 , pp. 403-410
    • Ma, C.B.1    Comerford, L.2    Wilson, J.3    Puttlitz, C.M.4
  • 24
    • 84862375694 scopus 로고    scopus 로고
    • An arthroscopic stitch for massive rotator cuff tears: the Mac stitch
    • MacGillivray J.D., and Ma C.B. An arthroscopic stitch for massive rotator cuff tears: the Mac stitch. Arthroscopy 20 (2004) 669-671
    • (2004) Arthroscopy , vol.20 , pp. 669-671
    • MacGillivray, J.D.1    Ma, C.B.2
  • 26
    • 0031887679 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair: analysis of technique and results at 2- and 3-year follow-up
    • Tauro J.C. Arthroscopic rotator cuff repair: analysis of technique and results at 2- and 3-year follow-up. Arthroscopy 14 (1998) 45-51
    • (1998) Arthroscopy , vol.14 , pp. 45-51
    • Tauro, J.C.1
  • 27
    • 0036488171 scopus 로고    scopus 로고
    • Arthroscopic repair of full-thickness tears of the rotator cuff: 2- to 14-year follow-up
    • Wilson F., Hinov V., and Adams G. Arthroscopic repair of full-thickness tears of the rotator cuff: 2- to 14-year follow-up. Arthroscopy 18 (2002) 136-144
    • (2002) Arthroscopy , vol.18 , pp. 136-144
    • Wilson, F.1    Hinov, V.2    Adams, G.3
  • 28
    • 0347951321 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair: 4- to 10-year results
    • Wolf E.M., Pennington W.T., and Agrawal V. Arthroscopic rotator cuff repair: 4- to 10-year results. Arthroscopy 20 (2004) 5-12
    • (2004) Arthroscopy , vol.20 , pp. 5-12
    • Wolf, E.M.1    Pennington, W.T.2    Agrawal, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.