메뉴 건너뛰기




Volumn 24, Issue 8, 2008, Pages 941-948

Single-Row Modified Mason-Allen Versus Double-Row Arthroscopic Rotator Cuff Repair: A Biomechanical and Surface Area Comparison

Author keywords

Biomechanics; Double row; Modified Mason Allen; Rotator cuff; Single row; Surface area

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTHROSCOPIC SURGERY; ARTICLE; BIOMECHANICS; CONTROLLED STUDY; DOUBLE ROW ARTHROSCOPIC REPAIR; FILM; FIXATION DEVICE; FRACTURE HEALING; INTERMETHOD COMPARISON; NONHUMAN; ROTATOR CUFF INJURY; SHEEP; SINGLE ROW MODIFIED MASON ALLEN REPAIR; STATISTICAL SIGNIFICANCE; SURGICAL APPROACH; SURGICAL TECHNIQUE; SUTURE ANCHOR;

EID: 47649124821     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2008.03.011     Document Type: Article
Times cited : (111)

References (27)
  • 1
    • 47649094564 scopus 로고    scopus 로고
    • AAOS research Web page statistics Accessed April 23, 2008.
    • AAOS research Web page statistics. www.aaos.org/wordhtml/research/stats/patientstats.asp Accessed April 23, 2008.
  • 2
    • 0029166070 scopus 로고
    • Repair of the rotator cuff. A comparison of results in two populations of patients
    • Misamore G.W., Ziegler D.W., and Rushton II J.L. Repair of the rotator cuff. A comparison of results in two populations of patients. J Bone Joint Surg Am 77 (1995) 1335-1339
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1335-1339
    • Misamore, G.W.1    Ziegler, D.W.2    Rushton II, J.L.3
  • 5
    • 0026032441 scopus 로고
    • Shoulder surgery for rotator cuff tears. Ultrasonographic 3-year follow-up of 97 cases
    • Wulker N., Melzer C., and Wirth C.J. Shoulder surgery for rotator cuff tears. Ultrasonographic 3-year follow-up of 97 cases. Acta Orthop Scand 62 (1991) 142-147
    • (1991) Acta Orthop Scand , vol.62 , pp. 142-147
    • Wulker, N.1    Melzer, C.2    Wirth, C.J.3
  • 6
    • 0942279683 scopus 로고    scopus 로고
    • The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears
    • Galatz L.M., Ball C.M., Teefey S.A., Middleton W.D., and Yamaguchi K. The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Joint Surg Am 86 (2004) 219-224
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 219-224
    • Galatz, L.M.1    Ball, C.M.2    Teefey, S.A.3    Middleton, W.D.4    Yamaguchi, K.5
  • 8
    • 0036590568 scopus 로고    scopus 로고
    • Rotator cuff tears: The effect of the reconstruction method on three-dimensional repair site area
    • Apreleva M., Ozbaydar M., Fitzgibbons P.G., and Warner J.J.P. Rotator cuff tears: The effect of the reconstruction method on three-dimensional repair site area. Arthroscopy 18 (2002) 519-526
    • (2002) Arthroscopy , vol.18 , pp. 519-526
    • Apreleva, M.1    Ozbaydar, M.2    Fitzgibbons, P.G.3    Warner, J.J.P.4
  • 9
    • 0242678574 scopus 로고    scopus 로고
    • Double-row arthroscopic rotator cuff repair: Re-establishing the footprint of the rotator cuff
    • Lo I.K.Y., and Burkhart S.S. Double-row arthroscopic rotator cuff repair: Re-establishing the footprint of the rotator cuff. Arthroscopy 19 (2003) 1035-1042
    • (2003) Arthroscopy , vol.19 , pp. 1035-1042
    • Lo, I.K.Y.1    Burkhart, S.S.2
  • 10
    • 5044221036 scopus 로고    scopus 로고
    • Mattress double anchor footprint repair: A novel, arthroscopic rotator cuff repair technique
    • Millett P.J., Mazzocca A., and Guanche C.A. Mattress double anchor footprint repair: A novel, arthroscopic rotator cuff repair technique. Arthroscopy 20 (2004) 875-879
    • (2004) Arthroscopy , vol.20 , pp. 875-879
    • Millett, P.J.1    Mazzocca, A.2    Guanche, C.A.3
  • 11
    • 0038386327 scopus 로고    scopus 로고
    • Primary fixation strength of rotator cuff repair techniques: A comparative study
    • Demirhan M., Atalar A.C., and Kilicoglu O. Primary fixation strength of rotator cuff repair techniques: A comparative study. Arthroscopy 19 (2003) 572-576
    • (2003) Arthroscopy , vol.19 , pp. 572-576
    • Demirhan, M.1    Atalar, A.C.2    Kilicoglu, O.3
  • 15
    • 0037336377 scopus 로고    scopus 로고
    • A modified Mason-Allen technique for rotator cuff repair using suture anchors
    • Scheibel M.T., and Habermeyer P. A modified Mason-Allen technique for rotator cuff repair using suture anchors. Arthroscopy 19 (2003) 330-333
    • (2003) Arthroscopy , vol.19 , pp. 330-333
    • Scheibel, M.T.1    Habermeyer, P.2
  • 16
    • 26844477493 scopus 로고    scopus 로고
    • Rotator cuff repair: An ex vivo analysis of suture anchor repair techniques on initial load to failure
    • Cummins C.A., Appleyard R.C., Strickland S., Haen P.S., Chen S., and Murrell A.C. Rotator cuff repair: An ex vivo analysis of suture anchor repair techniques on initial load to failure. Arthroscopy 21 (2005) 1236-1241
    • (2005) Arthroscopy , vol.21 , pp. 1236-1241
    • Cummins, C.A.1    Appleyard, R.C.2    Strickland, S.3    Haen, P.S.4    Chen, S.5    Murrell, A.C.6
  • 17
    • 22944438054 scopus 로고    scopus 로고
    • Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques
    • Park M.C., Cadet E.R., Levine W.N., Bigliani L.U., and Ahmad C.S. Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques. Am J Sports Med 33 (2005) 1154-1159
    • (2005) Am J Sports Med , vol.33 , pp. 1154-1159
    • Park, M.C.1    Cadet, E.R.2    Levine, W.N.3    Bigliani, L.U.4    Ahmad, C.S.5
  • 19
    • 28344449190 scopus 로고    scopus 로고
    • Contact area, contact pressure, and pressure patterns of the tendon-bone interface after rotator cuff repair
    • Tuoheti Y., Itoi E., Yamamoto N., et al. Contact area, contact pressure, and pressure patterns of the tendon-bone interface after rotator cuff repair. Am J Sports Med 33 (2005) 1869-1874
    • (2005) Am J Sports Med , vol.33 , pp. 1869-1874
    • Tuoheti, Y.1    Itoi, E.2    Yamamoto, N.3
  • 20
    • 32944480447 scopus 로고    scopus 로고
    • Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair
    • Kim D.H., El Attrache N.S., Tibone J.E., et al. Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair. Am J Sports Med 34 (2006) 407-414
    • (2006) Am J Sports Med , vol.34 , pp. 407-414
    • Kim, D.H.1    El Attrache, N.S.2    Tibone, J.E.3
  • 21
    • 31844453610 scopus 로고    scopus 로고
    • Biomechanical evaluation of arthroscopic rotator cuff repairs: Double-row compared with single-row fixation
    • Ma C.B., Comerford L., Wilson J., and Puttlitz C.M. Biomechanical evaluation of arthroscopic rotator cuff repairs: Double-row compared with single-row fixation. J Bone Joint Surg Am 88 (2006) 403-410
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 403-410
    • Ma, C.B.1    Comerford, L.2    Wilson, J.3    Puttlitz, C.M.4
  • 22
    • 36549000239 scopus 로고    scopus 로고
    • Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model
    • Mahar A., Tamborlane J., Oka R., Esch J., and Pedowitz R.A. Single-row suture anchor repair of the rotator cuff is biomechanically equivalent to double-row repair in a bovine model. Arthroscopy 23 (2007) 1265-1270
    • (2007) Arthroscopy , vol.23 , pp. 1265-1270
    • Mahar, A.1    Tamborlane, J.2    Oka, R.3    Esch, J.4    Pedowitz, R.A.5
  • 23
    • 33750844296 scopus 로고    scopus 로고
    • A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair
    • Smith C.D., Alexander S., Hill A.M., et al. A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair. J Bone Joint Surg Am 88 (2006) 2425-2431
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 2425-2431
    • Smith, C.D.1    Alexander, S.2    Hill, A.M.3
  • 24
    • 33750442166 scopus 로고    scopus 로고
    • The effect of double-row fixation on initial repair strength in rotator cuff repair: A biomechanical study
    • Meier S.W., and Meier J.D. The effect of double-row fixation on initial repair strength in rotator cuff repair: A biomechanical study. Arthroscopy 22 (2006) 1168-1173
    • (2006) Arthroscopy , vol.22 , pp. 1168-1173
    • Meier, S.W.1    Meier, J.D.2
  • 26
    • 34447560059 scopus 로고    scopus 로고
    • Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: A randomized controlled trial
    • Franceschi F., Ruzzini L., Longo U.G., et al. Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: A randomized controlled trial. Am J Sports Med 35 (2007) 1254-1260
    • (2007) Am J Sports Med , vol.35 , pp. 1254-1260
    • Franceschi, F.1    Ruzzini, L.2    Longo, U.G.3
  • 27
    • 34447529361 scopus 로고    scopus 로고
    • Can a double-row anchorage technique improve tendon healing in arthroscopic rotator cuff repair?. A prospective, nonrandomized, comparative study of double-row and single-row anchorage techniques with computed tomographic arthrography tendon healing assessment
    • Charousset C., Grimberg J., Duranthon L.D., Bellaiche L., and Petrover D. Can a double-row anchorage technique improve tendon healing in arthroscopic rotator cuff repair?. A prospective, nonrandomized, comparative study of double-row and single-row anchorage techniques with computed tomographic arthrography tendon healing assessment. Am J Sports Med 35 (2007) 1247-1253
    • (2007) Am J Sports Med , vol.35 , pp. 1247-1253
    • Charousset, C.1    Grimberg, J.2    Duranthon, L.D.3    Bellaiche, L.4    Petrover, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.