메뉴 건너뛰기




Volumn 16, Issue 5, 2008, Pages 497-503

Arthroscopic repair of rotator cuff tear with a modified Mason-Allen stitch: Mid-term clinical and ultrasound outcomes

Author keywords

Arthroscopy; Modified Mason Allen; Re tear; Repair; Rotator cuff; Shoulder; Stitch

Indexed keywords

AGE; ARTHROSCOPY; ARTICLE; ECHOGRAPHY; FEMALE; HUMAN; INJURY; MALE; METHODOLOGY; MIDDLE AGED; PATIENT SATISFACTION; PROSPECTIVE STUDY; RECURRENT DISEASE; RETROSPECTIVE STUDY; ROTATOR CUFF; SUTURE ANCHOR; SUTURING METHOD;

EID: 43049171631     PISSN: 09422056     EISSN: 14337347     Source Type: Journal    
DOI: 10.1007/s00167-007-0461-2     Document Type: Article
Times cited : (40)

References (42)
  • 1
    • 0036590568 scopus 로고    scopus 로고
    • Rotator cuff tears: The effect of the reconstruction method on three-dimensional repair site area
    • 5
    • Apreleva M, Ozbazdar M, Fitygibbons BA, Warner JJP (2002) Rotator cuff tears: the effect of the reconstruction method on three-dimensional repair site area. Arthroscopy 18(5):519-526
    • (2002) Arthroscopy , vol.18 , pp. 519-526
    • Apreleva, M.1    Ozbazdar, M.2    Fitygibbons, B.A.3    Warner, J.J.P.4
  • 5
    • 33645017933 scopus 로고    scopus 로고
    • Comparative and experimental study on different tendinous grasping techniques in rotator cuff repair: A new reinforced stitch
    • 2
    • Bungaro P, Rotini R, Traina F et al (2005) Comparative and experimental study on different tendinous grasping techniques in rotator cuff repair: a new reinforced stitch. Chir Organi Mov 90(2):113-119
    • (2005) Chir Organi Mov , vol.90 , pp. 113-119
    • Bungaro, P.1    Rotini, R.2    Traina, F.3
  • 6
    • 0033971525 scopus 로고    scopus 로고
    • A stepwise approach to arthroscopic rotator cuff repair based on biomechanical principles
    • Burkhart SS (2000) A stepwise approach to arthroscopic rotator cuff repair based on biomechanical principles. Arthroscopy 16:82-90
    • (2000) Arthroscopy , vol.16 , pp. 82-90
    • Burkhart, S.S.1
  • 7
    • 0035526413 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair: Analysis of results by tear size and repair technique: Margin convergence versus direct tendon-to-bone repair
    • Burkhart SS, Danaceau SM, Pearce CE Jr (2001) Arthroscopic rotator cuff repair:analysis of results by tear size and repair technique: margin convergence versus direct tendon-to-bone repair. Arthroscopy 17:905-912
    • (2001) Arthroscopy , vol.17 , pp. 905-912
    • Burkhart, S.S.1    Danaceau, S.M.2    Pearce Jr., C.E.3
  • 10
    • 0023115201 scopus 로고
    • A clinical method of functional assessment of the shoulder
    • Constant C, Murley A (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160-164
    • (1987) Clin Orthop Relat Res , vol.214 , pp. 160-164
    • Constant, C.1    Murley, A.2
  • 11
    • 0037492958 scopus 로고    scopus 로고
    • Mode of failure for rotator cuff repair with suture anchors identified at revision surgery
    • Cummins CA, Murrell GA (2003) Mode of failure for rotator cuff repair with suture anchors identified at revision surgery. J Shoulder Elbow Surg 12:128-133
    • (2003) J Shoulder Elbow Surg , vol.12 , pp. 128-133
    • Cummins, C.A.1    Murrell, G.A.2
  • 12
    • 0023001093 scopus 로고
    • Repair of the rotator cuff. End result study of factors influencing reconstruction
    • Ellman H, Hanker G, Bayer M (1986) Repair of the rotator cuff. End result study of factors influencing reconstruction. J Bone Joint Surg Am 68:1136-1144
    • (1986) J Bone Joint Surg Am , vol.68 , pp. 1136-1144
    • Ellman, H.1    Hanker, G.2    Bayer, M.3
  • 13
    • 0942279683 scopus 로고    scopus 로고
    • The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears
    • Galatz LM, Ball CM, Teefey SA, Middleton W, Yamaguchi K (2004) The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Joint Surg Am 86:708-716
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 708-716
    • Galatz, L.M.1    Ball, C.M.2    Teefey, S.A.3    Middleton, W.4    Yamaguchi, K.5
  • 14
    • 0028279818 scopus 로고
    • Functional and anatomical results after rotator cuff repair
    • Gazielly DF, Gleyze P, Montagnon C (1994) Functional and anatomical results after rotator cuff repair. Clin Orthop 304:43-53
    • (1994) Clin Orthop , vol.304 , pp. 43-53
    • Gazielly, D.F.1    Gleyze, P.2    Montagnon, C.3
  • 17
    • 0028243496 scopus 로고
    • Fatty muscle degeneration in cuff ruptures. Pre and postoperative evaluation by CT scan
    • Goutallier D, postel JM, Bernageau J, Lavau L, Voisin MC (1994) Fatty muscle degeneration in cuff ruptures. Pre and postoperative evaluation by CT scan. Clin Orthop 304:78-83
    • (1994) Clin Orthop , vol.304 , pp. 78-83
    • Goutallier, D.1    Postel, J.M.2    Bernageau, J.3    Lavau, L.4    Voisin, M.C.5
  • 20
    • 0030279929 scopus 로고    scopus 로고
    • Postoperative assessment of shoulder function: A prospective study of full-thickness rotator cuff tears
    • 6
    • Iannotti JP,Bernot MP, Kuhlman JR, Kelley MJ, Williams JR (1996) Postoperative assessment of shoulder function: a prospective study of full-thickness rotator cuff tears. J Shoulder Elbow Surg 5(6):449-457
    • (1996) J Shoulder Elbow Surg , vol.5 , pp. 449-457
    • Iannotti, J.P.1    Bernot, M.P.2    Kuhlman, J.R.3    Kelley, M.J.4    Williams, J.R.5
  • 21
    • 6344253406 scopus 로고    scopus 로고
    • Prospective evaluation of the effect of rotator cuff integrity on the outcome of open rotator cuff repairs
    • Klepps S, Bishop J, Lin J, Cahon O, Strauss A, Hayes P, Flatow EL (2004) Prospective evaluation of the effect of rotator cuff integrity on the outcome of open rotator cuff repairs. Am J Sports Med 322:1716-1722
    • (2004) Am J Sports Med , vol.322 , pp. 1716-1722
    • Klepps, S.1    Bishop, J.2    Lin, J.3    Cahon, O.4    Strauss, A.5    Hayes, P.6    Flatow, E.L.7
  • 24
    • 33750698975 scopus 로고    scopus 로고
    • Influence of tendon healing after arthroscopic rotator cuff repair on clinical outcome using single row Mason-Allen suture technique: A prospective, MRI controlled study
    • July15 (Epub)
    • Lichtenberg S, Liem D, Magossch P, Habermeyer P (2006) Influence of tendon healing after arthroscopic rotator cuff repair on clinical outcome using single row Mason-Allen suture technique: a prospective, MRI controlled study. Knee Surg Sports Traumatol Arthrosc, July15 (Epub)
    • (2006) Knee Surg Sports Traumatol Arthrosc
    • Lichtenberg, S.1    Liem, D.2    Magossch, P.3    Habermeyer, P.4
  • 27
    • 33745742730 scopus 로고    scopus 로고
    • Responsiveness of self-report scales in patients recovering from rotator cuff surgery
    • 4
    • MacDermid JC, Drosdowech D, Faber K (2006) Responsiveness of self-report scales in patients recovering from rotator cuff surgery. J Shoulder Elbow Surg 15(4):407-414
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 407-414
    • MacDermid, J.C.1    Drosdowech, D.2    Faber, K.3
  • 29
    • 28344447544 scopus 로고    scopus 로고
    • Arthroscopic single-row versus double-row suture anchor rotator cuff repair
    • 12. Epub 2005 Oct 6
    • Mazzocca AD, Millett PJ, Guanche CA, Santangelo SA, Arciero RA (2005) Arthroscopic single-row versus double-row suture anchor rotator cuff repair. Am J Sports Med 33(12):1861-1868. Epub 2005 Oct 6
    • (2005) Am J Sports Med , vol.33 , pp. 1861-1868
    • Mazzocca, A.D.1    Millett, P.J.2    Guanche, C.A.3    Santangelo, S.A.4    Arciero, R.A.5
  • 30
    • 1942532792 scopus 로고    scopus 로고
    • Association of osteopenia of the humeral head with full-thickness rotator cuff tears
    • Meyer DC, Fucentese SF, Koller B, Gerber C (2004) Association of osteopenia of the humeral head with full-thickness rotator cuff tears. J Shoulder Elbow Surg 13:333-337
    • (2004) J Shoulder Elbow Surg , vol.13 , pp. 333-337
    • Meyer, D.C.1    Fucentese, S.F.2    Koller, B.3    Gerber, C.4
  • 31
    • 5044221036 scopus 로고    scopus 로고
    • Mattress double anchor footprint: A novel, arthroscopic rotator cuff repair technique
    • Millett PJ, Mazzocca A, Guanche C (2004) Mattress double anchor footprint: A novel, arthroscopic rotator cuff repair technique. Arthroscopy 20:875-887
    • (2004) Arthroscopy , vol.20 , pp. 875-887
    • Millett, P.J.1    Mazzocca, A.2    Guanche, C.3
  • 32
    • 0036357088 scopus 로고    scopus 로고
    • Arthroscopic repair of medium to large full-thikness rotator cuff tears: Outcome at 2-to-6 year follow-up
    • Murray TF Jr, Lajtai G, Mileski RM, Snyder SJ (2002) Arthroscopic repair of medium to large full-thikness rotator cuff tears: outcome at 2-to-6 year follow-up. J Shoulder Elbow Surg 11:19-24
    • (2002) J Shoulder Elbow Surg , vol.11 , pp. 19-24
    • Murray Jr., T.F.1    Lajtai, G.2    Mileski, R.M.3    Snyder, S.J.4
  • 34
    • 0025239585 scopus 로고
    • Classification of rotator cuff lesions
    • Patte D (1990) Classification of rotator cuff lesions. Clin Orthop 254:81-86
    • (1990) Clin Orthop , vol.254 , pp. 81-86
    • Patte, D.1
  • 35
    • 0031006780 scopus 로고    scopus 로고
    • A biomechanical evaluation of the suture anchors in repair of the rotator cuff
    • Rossouw DJ, McElroy BJ, Amis AA, Emery RJ (1997) A biomechanical evaluation of the suture anchors in repair of the rotator cuff. J Bone Joint Surg Br 79:458-461
    • (1997) J Bone Joint Surg Br , vol.79 , pp. 458-461
    • Rossouw, D.J.1    McElroy, B.J.2    Amis, A.A.3    Emery, R.J.4
  • 36
    • 34250709969 scopus 로고    scopus 로고
    • Stress distribution in the supraspinatus tendon after tendon repair: Suture anchors versus transosseous suture fixation
    • Jan 11 (Epub)
    • Sano H, Yamashita T, Waabayashi I, Itoi E (2007) Stress distribution in the supraspinatus tendon after tendon repair: suture anchors versus transosseous suture fixation. Am J Sports Med, Jan 11 (Epub)
    • (2007) Am J Sports Med
    • Sano, H.1    Yamashita, T.2    Waabayashi, I.3    Itoi, E.4
  • 38
    • 28444453275 scopus 로고    scopus 로고
    • Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: Single-row versus dual row fixation
    • 11
    • Sugaya H, Maeda K, Matsuki K, Moriishi J (2005) Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual row fixation. Arthroscopy 21(11):1307-1316
    • (2005) Arthroscopy , vol.21 , pp. 1307-1316
    • Sugaya, H.1    Maeda, K.2    Matsuki, K.3    Moriishi, J.4
  • 39
    • 0031887679 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair: Analysis of technique and results at 2- and 3 year follow-up
    • Tauro JC (1998) Arthroscopic rotator cuff repair: analysis of technique and results at 2- and 3 year follow-up. Arthroscopy 14:45-51
    • (1998) Arthroscopy , vol.14 , pp. 45-51
    • Tauro, J.C.1
  • 40
    • 1842578965 scopus 로고    scopus 로고
    • Detection and quantification of rotator cuff tears. Comparison of ultrasonographic, magnetic resonance imaging, and arthroscopic findings in seventy-one consecutive cases
    • 4
    • Teefey SA, Rubin DA, Middleton WD, Hildebolt CF, Boyer MI (2004) Detection and quantification of rotator cuff tears. Comparison of ultrasonographic, magnetic resonance imaging, and arthroscopic findings in seventy-one consecutive cases. J Bone Joint Surg Am 86-A(4):708-716
    • (2004) J Bone Joint Surg Am , vol.86 A , pp. 708-716
    • Teefey, S.A.1    Rubin, D.A.2    Middleton, W.D.3    Hildebolt, C.F.4    Boyer, M.I.5
  • 41
    • 28344449190 scopus 로고    scopus 로고
    • Contact area, contact pressure, and pressure patterns of the tendon-bone interface after rotator cuff repair
    • 12. Epub 2005 Sep 12
    • Tuoheti Y, Itoi E, Yamamoto N, Seki N, Abe H, Minagawa H, Okada K, Shimada Y (2005) Contact area, contact pressure, and pressure patterns of the tendon-bone interface after rotator cuff repair. Am J Sports Med 33(12):1869-1874. Epub 2005 Sep 12
    • (2005) Am J Sports Med , vol.33 , pp. 1869-1874
    • Tuoheti, Y.1    Itoi, E.2    Yamamoto, N.3    Seki, N.4    Abe, H.5    Minagawa, H.6    Okada, K.7    Shimada, Y.8
  • 42
    • 0015965271 scopus 로고
    • Surgical repair of tears of tears of the rotator cuff of the shoulder. Factors influencing the result
    • Wolgang GL (1974) Surgical repair of tears of tears of the rotator cuff of the shoulder. Factors influencing the result. J Bone Joint Surg Am 56:14-26
    • (1974) J Bone Joint Surg Am , vol.56 , pp. 14-26
    • Wolgang, G.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.