메뉴 건너뛰기




Volumn 25, Issue 2, 2009, Pages 192-199

Cyclic Load and Failure Behavior of Arthroscopic Knots and High Strength Sutures

Author keywords

Arthroscopy; Biomechanics; Braided sutures; Knot tying; Rotator cuff; Ultra high molecular weight polyethylene

Indexed keywords

POLYETHYLENE; ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE;

EID: 58549109431     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2008.09.010     Document Type: Article
Times cited : (108)

References (27)
  • 1
    • 38549160736 scopus 로고    scopus 로고
    • Cyclic load testing and ultimate failure strength of biodegradable glenoid anchors
    • Barber F.A., Coons D.A., and Ruiz-Suarez M. Cyclic load testing and ultimate failure strength of biodegradable glenoid anchors. Arthroscopy 24 (2008) 224-228
    • (2008) Arthroscopy , vol.24 , pp. 224-228
    • Barber, F.A.1    Coons, D.A.2    Ruiz-Suarez, M.3
  • 2
    • 33846579087 scopus 로고    scopus 로고
    • Biomechanical comparison of 3 suture anchor configurations for repair of type II SLAP lesions
    • Domb B.G., Ehteshami J.R., Shindle M.K., et al. Biomechanical comparison of 3 suture anchor configurations for repair of type II SLAP lesions. Arthroscopy 23 (2007) 135-140
    • (2007) Arthroscopy , vol.23 , pp. 135-140
    • Domb, B.G.1    Ehteshami, J.R.2    Shindle, M.K.3
  • 3
    • 28444457254 scopus 로고    scopus 로고
    • The biomechanical evaluation of four fixation techniques for proximal biceps tenodesis
    • Mazzocca A.D., Bicos J., Santangelo S., Romeo A.A., and Arciero R.A. The biomechanical evaluation of four fixation techniques for proximal biceps tenodesis. Arthroscopy 21 (2005) 1296-1306
    • (2005) Arthroscopy , vol.21 , pp. 1296-1306
    • Mazzocca, A.D.1    Bicos, J.2    Santangelo, S.3    Romeo, A.A.4    Arciero, R.A.5
  • 4
    • 44249105621 scopus 로고    scopus 로고
    • Medial rotator cuff failure after arthroscopic double-row rotator cuff repair
    • Trantalis J.N., Boorman R.S., Pletsch K., and Lo I.K. Medial rotator cuff failure after arthroscopic double-row rotator cuff repair. Arthroscopy 24 (2008) 727-731
    • (2008) Arthroscopy , vol.24 , pp. 727-731
    • Trantalis, J.N.1    Boorman, R.S.2    Pletsch, K.3    Lo, I.K.4
  • 5
    • 43049123163 scopus 로고    scopus 로고
    • Arthroscopic repair of full-thickness tears of the rotator cuff in patients younger than 40 years
    • Krishnan S.G., Harkins D.C., Schiffern S.C., Pennington S.D., and Burkhead W.Z. Arthroscopic repair of full-thickness tears of the rotator cuff in patients younger than 40 years. Arthroscopy 24 (2008) 324-328
    • (2008) Arthroscopy , vol.24 , pp. 324-328
    • Krishnan, S.G.1    Harkins, D.C.2    Schiffern, S.C.3    Pennington, S.D.4    Burkhead, W.Z.5
  • 6
    • 31844455176 scopus 로고    scopus 로고
    • A biomechanical and radiographic analysis of standard and intracortical suture anchors for arthroscopic rotator cuff repair
    • Mahar A., Allred D.W., Wedemeyer M., Abbi G., and Pedowitz R. A biomechanical and radiographic analysis of standard and intracortical suture anchors for arthroscopic rotator cuff repair. Arthroscopy 22 (2006) 130-135
    • (2006) Arthroscopy , vol.22 , pp. 130-135
    • Mahar, A.1    Allred, D.W.2    Wedemeyer, M.3    Abbi, G.4    Pedowitz, R.5
  • 7
    • 34047143640 scopus 로고    scopus 로고
    • Cyclic load testing of biodegradable suture anchors containing 2 high-strength sutures
    • Barber F.A., Coons D.A., and Ruiz-Suarez M. Cyclic load testing of biodegradable suture anchors containing 2 high-strength sutures. Arthroscopy 23 (2007) 355-360
    • (2007) Arthroscopy , vol.23 , pp. 355-360
    • Barber, F.A.1    Coons, D.A.2    Ruiz-Suarez, M.3
  • 8
    • 0942279683 scopus 로고    scopus 로고
    • The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears
    • Galatz L.M., Ball C.M., Teefey S.A., Middleton W.D., and Yamaguchi K. The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Joint Surg Am 86 (2004) 219-224
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 219-224
    • Galatz, L.M.1    Ball, C.M.2    Teefey, S.A.3    Middleton, W.D.4    Yamaguchi, K.5
  • 10
    • 33751062368 scopus 로고    scopus 로고
    • Mechanical and handling properties of braided polyblend polyethylene sutures in comparison to braided polyester and monofilament polydioxanone sutures
    • Wust D.M., Meyer D.C., Favre P., and Gerber C. Mechanical and handling properties of braided polyblend polyethylene sutures in comparison to braided polyester and monofilament polydioxanone sutures. Arthroscopy 22 (2006) 1146-1153
    • (2006) Arthroscopy , vol.22 , pp. 1146-1153
    • Wust, D.M.1    Meyer, D.C.2    Favre, P.3    Gerber, C.4
  • 11
    • 30144435964 scopus 로고    scopus 로고
    • Evaluation of 5 knots and 2 suture materials for arthroscopic rotator cuff repair: Very strong sutures can still slip
    • Abbi G., Espinoza L., Odell T., Mahar A., and Pedowitz R. Evaluation of 5 knots and 2 suture materials for arthroscopic rotator cuff repair: Very strong sutures can still slip. Arthroscopy 22 (2006) 38-43
    • (2006) Arthroscopy , vol.22 , pp. 38-43
    • Abbi, G.1    Espinoza, L.2    Odell, T.3    Mahar, A.4    Pedowitz, R.5
  • 12
    • 0035497430 scopus 로고    scopus 로고
    • Significance of the internal locking mechanism for loop security enhancement in the arthroscopic knot
    • Kim S.H., Ha K.I., and Kim J.S. Significance of the internal locking mechanism for loop security enhancement in the arthroscopic knot. Arthroscopy 17 (2001) 850-855
    • (2001) Arthroscopy , vol.17 , pp. 850-855
    • Kim, S.H.1    Ha, K.I.2    Kim, J.S.3
  • 13
    • 33744524585 scopus 로고    scopus 로고
    • Comparison and performance characteristics of 3 different knots when tied with 2 suture materials used for shoulder arthroscopy
    • Mahar A.T., Moezzi D.M., Serra-Hsu F., and Pedowitz R.A. Comparison and performance characteristics of 3 different knots when tied with 2 suture materials used for shoulder arthroscopy. Arthroscopy 22 (2006) 614.e1-614.e2
    • (2006) Arthroscopy , vol.22
    • Mahar, A.T.1    Moezzi, D.M.2    Serra-Hsu, F.3    Pedowitz, R.A.4
  • 14
    • 33746810983 scopus 로고    scopus 로고
    • Biomechanical characteristics of 10 arthroscopic knots
    • Hassinger S.M., Wongworawat M.D., and Hechanova J.W. Biomechanical characteristics of 10 arthroscopic knots. Arthroscopy 22 (2006) 827-832
    • (2006) Arthroscopy , vol.22 , pp. 827-832
    • Hassinger, S.M.1    Wongworawat, M.D.2    Hechanova, J.W.3
  • 15
    • 34547544257 scopus 로고    scopus 로고
    • Initial loop and knot security of arthroscopic knots using high-strength sutures
    • Shah M.R., Strauss E.J., Kaplan K., Jazrawi L., and Rosen J. Initial loop and knot security of arthroscopic knots using high-strength sutures. Arthroscopy 23 (2007) 884-888
    • (2007) Arthroscopy , vol.23 , pp. 884-888
    • Shah, M.R.1    Strauss, E.J.2    Kaplan, K.3    Jazrawi, L.4    Rosen, J.5
  • 16
    • 0034235854 scopus 로고    scopus 로고
    • The SMC knot-A new slip knot with locking mechanism
    • Kim S.H., and Ha K.I. The SMC knot-A new slip knot with locking mechanism. Arthroscopy 16 (2000) 563-565
    • (2000) Arthroscopy , vol.16 , pp. 563-565
    • Kim, S.H.1    Ha, K.I.2
  • 17
    • 15944392291 scopus 로고    scopus 로고
    • Arthroscopic sliding knot: How many additional half-hitches are really needed?
    • Kim S.H., Yoo J.C., Wang J.H., Choi K.W., Bae T.S., and Lee C.Y. Arthroscopic sliding knot: How many additional half-hitches are really needed?. Arthroscopy 21 (2005) 405-411
    • (2005) Arthroscopy , vol.21 , pp. 405-411
    • Kim, S.H.1    Yoo, J.C.2    Wang, J.H.3    Choi, K.W.4    Bae, T.S.5    Lee, C.Y.6
  • 18
    • 13444263371 scopus 로고    scopus 로고
    • A biomechanical comparison of arthroscopic sliding and sliding-locking knots
    • Elkousy H.A., Sekiya J.K., Stabile K.J., and McMahon P.J. A biomechanical comparison of arthroscopic sliding and sliding-locking knots. Arthroscopy 21 (2005) 204-210
    • (2005) Arthroscopy , vol.21 , pp. 204-210
    • Elkousy, H.A.1    Sekiya, J.K.2    Stabile, K.J.3    McMahon, P.J.4
  • 20
    • 0031452936 scopus 로고    scopus 로고
    • Cyclic loading of anchor-based rotator cuff repairs: Confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation
    • Burkhart S.S., Diaz Pagan J.L., Wirth M.A., and Athanasiou K.A. Cyclic loading of anchor-based rotator cuff repairs: Confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation. Arthroscopy 13 (1997) 720-724
    • (1997) Arthroscopy , vol.13 , pp. 720-724
    • Burkhart, S.S.1    Diaz Pagan, J.L.2    Wirth, M.A.3    Athanasiou, K.A.4
  • 21
    • 0030900130 scopus 로고    scopus 로고
    • Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure
    • Burkhart S.S., Johnson T.C., Wirth M.A., and Athanasiou K.A. Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure. Arthroscopy 13 (1997) 172-176
    • (1997) Arthroscopy , vol.13 , pp. 172-176
    • Burkhart, S.S.1    Johnson, T.C.2    Wirth, M.A.3    Athanasiou, K.A.4
  • 22
    • 33745872209 scopus 로고    scopus 로고
    • The arthroscopic square knot: A biomechanical comparison with open and arthroscopic knots
    • Elkousy H., Hammerman S.M., Edwards T.B., et al. The arthroscopic square knot: A biomechanical comparison with open and arthroscopic knots. Arthroscopy 22 (2006) 736-741
    • (2006) Arthroscopy , vol.22 , pp. 736-741
    • Elkousy, H.1    Hammerman, S.M.2    Edwards, T.B.3
  • 23
    • 2442511176 scopus 로고    scopus 로고
    • Arthroscopic knots: Determining the optimal balance of loop security and knot security
    • Lo I.K., Burkhart S.S., Chan K.C., and Athanasiou K. Arthroscopic knots: Determining the optimal balance of loop security and knot security. Arthroscopy 20 (2004) 489-502
    • (2004) Arthroscopy , vol.20 , pp. 489-502
    • Lo, I.K.1    Burkhart, S.S.2    Chan, K.C.3    Athanasiou, K.4
  • 25
  • 27
    • 11844282194 scopus 로고    scopus 로고
    • Arthroscopic knot tying: The role of instrumentation in achieving knot security
    • Milia M.J., Peindl R.D., and Connor P.M. Arthroscopic knot tying: The role of instrumentation in achieving knot security. Arthroscopy 21 (2005) 69-76
    • (2005) Arthroscopy , vol.21 , pp. 69-76
    • Milia, M.J.1    Peindl, R.D.2    Connor, P.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.