메뉴 건너뛰기




Volumn 32, Issue 2, 2007, Pages 217-222

Fluoroscopic computer-assisted pedicle screw placement through a mature fusion mass: An assessment of 24 consecutive cases with independent analysis of computed tomography and clinical data

Author keywords

Computed tomography; Computer assisted fluoroscopy; Fusion mass; Thoracolumbar pedicle screws

Indexed keywords

ARTICLE; CLINICAL ARTICLE; COHORT ANALYSIS; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FLUOROSCOPY; HUMAN; PEDICLE SCREW; PRIORITY JOURNAL; SPINE FUSION; SPINE TUMOR; STATISTICAL SIGNIFICANCE;

EID: 33846279003     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/01.brs.0000251751.51936.3f     Document Type: Article
Times cited : (33)

References (41)
  • 1
    • 0034061781 scopus 로고    scopus 로고
    • Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    • Amiot LP, Lang K, Putzier M, et al. Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 2000;25:606-14.
    • (2000) Spine , vol.25 , pp. 606-614
    • Amiot, L.P.1    Lang, K.2    Putzier, M.3
  • 2
    • 0030909607 scopus 로고    scopus 로고
    • Planning and insertion of pedicle screws with computer assistance
    • Berlermann U, Monin D, Arm E, et al. Planning and insertion of pedicle screws with computer assistance. J Spinal Disord 1997;10:117-24.
    • (1997) J Spinal Disord , vol.10 , pp. 117-124
    • Berlermann, U.1    Monin, D.2    Arm, E.3
  • 4
    • 0029157802 scopus 로고
    • Application of frameless stereotaxy to pedicle screw fixation of the spine
    • Kalfas IH, Korsmos DW, Murphy MA, et al. Application of frameless stereotaxy to pedicle screw fixation of the spine. J Neurosurg 1995;83:641-7.
    • (1995) J Neurosurg , vol.83 , pp. 641-647
    • Kalfas, I.H.1    Korsmos, D.W.2    Murphy, M.A.3
  • 5
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomized controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M, et al. Accuracy of pedicle screw insertion with and without computer assistance: a randomized controlled clinical study in 100 consecutive patients. Eur Spine J 2000;9:235-40.
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3
  • 6
    • 0031696110 scopus 로고    scopus 로고
    • Pedicle screw placement using imageguided techniques
    • Merloz P, Tonetti J, Pittet L, et al. Pedicle screw placement using imageguided techniques. Clin Orthop 1998;354:39-48.
    • (1998) Clin Orthop , vol.354 , pp. 39-48
    • Merloz, P.1    Tonetti, J.2    Pittet, L.3
  • 7
    • 0037442352 scopus 로고    scopus 로고
    • Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: A cadaver study
    • Mirza SK, Wiggins GC, Kuntz IV C, et al. Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study. Spine 2003;28:402-13.
    • (2003) Spine , vol.28 , pp. 402-413
    • Mirza, S.K.1    Wiggins, G.C.2    Kuntz IV, C.3
  • 8
    • 0035865653 scopus 로고    scopus 로고
    • Accuracy requirements for image-guided spinal pedicle screw placement
    • Rampersaud YR, Simon DA, Foley KT. Accuracy requirements for image-guided spinal pedicle screw placement. Spine 2001;26:352-9.
    • (2001) Spine , vol.26 , pp. 352-359
    • Rampersaud, Y.R.1    Simon, D.A.2    Foley, K.T.3
  • 9
    • 0002660907 scopus 로고    scopus 로고
    • Computer-assisted spine surgery
    • Schlenzka D, Laine T, Lund T. Computer-assisted spine surgery. Eur Spine J 2000;1(suppl):57- 64.
    • (2000) Eur Spine J , vol.1 , Issue.SUPPL. , pp. 57-64
    • Schlenzka, D.1    Laine, T.2    Lund, T.3
  • 10
    • 0035865652 scopus 로고    scopus 로고
    • Virtual fluoroscopy: Computerassisted fluoroscopic navigation
    • Foley KT, Simon DA, Rampersaud YR. Virtual fluoroscopy: computerassisted fluoroscopic navigation. Spine 2001;26:347-51.
    • (2001) Spine , vol.26 , pp. 347-351
    • Foley, K.T.1    Simon, D.A.2    Rampersaud, Y.R.3
  • 12
    • 33747822778 scopus 로고    scopus 로고
    • Virtual fluoroscopy: Multi-planar x-ray guidance with minimal radiation exposure
    • Foley KT, Rampersaud YR, Simon DA. Virtual fluoroscopy: multi-planar x-ray guidance with minimal radiation exposure. Eur Spine J 1999;8(suppl 1):36.
    • (1999) Eur Spine J , vol.8 , Issue.SUPPL. 1 , pp. 36
    • Foley, K.T.1    Rampersaud, Y.R.2    Simon, D.A.3
  • 13
    • 0002880775 scopus 로고    scopus 로고
    • A new approach to computer-aided spine surgery: Fluoroscopy-based surgical navigation
    • Nolte LP, Slomczykowski MA, Berlemann U, et al. A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation. Eur Spine J 2000;9(suppl):78-88.
    • (2000) Eur Spine J , vol.9 , Issue.SUPPL. , pp. 78-88
    • Nolte, L.P.1    Slomczykowski, M.A.2    Berlemann, U.3
  • 14
    • 0038546468 scopus 로고    scopus 로고
    • Prospective comparison of virtual fluoroscopy to fluoroscopy and plain radiographs for placement of lumbar pedicle screws
    • Resnick DK. Prospective comparison of virtual fluoroscopy to fluoroscopy and plain radiographs for placement of lumbar pedicle screws. J Spinal Disord Tech 2003;16:254-60.
    • (2003) J Spinal Disord Tech , vol.16 , pp. 254-260
    • Resnick, D.K.1
  • 15
    • 0023790873 scopus 로고
    • Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
    • Weinstein JN, Spratt KF, Spengler D, et al. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 1988;13:1012-8.
    • (1988) Spine , vol.13 , pp. 1012-1018
    • Weinstein, J.N.1    Spratt, K.F.2    Spengler, D.3
  • 16
    • 0032076473 scopus 로고    scopus 로고
    • Anatomic considerations of pedicle screw placement in the thoracic spine: Roy-Camille technique versus open lamina technique
    • Xu R, Ebraheim NA, Ou Y, et al. Anatomic considerations of pedicle screw placement in the thoracic spine: Roy-Camille technique versus open lamina technique. Spine 1998;23:1065-8.
    • (1998) Spine , vol.23 , pp. 1065-1068
    • Xu, R.1    Ebraheim, N.A.2    Ou, Y.3
  • 17
    • 0034667336 scopus 로고    scopus 로고
    • Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion
    • Rampersaud YR, Foley KT, Shen AC, et al. Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine 2000;25:2637-45.
    • (2000) Spine , vol.25 , pp. 2637-2645
    • Rampersaud, Y.R.1    Foley, K.T.2    Shen, A.C.3
  • 18
    • 0037099509 scopus 로고    scopus 로고
    • Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities
    • Belmont PJ Jr, Klemme WR, Robinson M, et al. Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities. Spine 2002;27:1558-66.
    • (2002) Spine , vol.27 , pp. 1558-1566
    • Belmont Jr, P.J.1    Klemme, W.R.2    Robinson, M.3
  • 19
    • 0035500223 scopus 로고    scopus 로고
    • In vivo accuracy of thoracic pedicle screws
    • Belmont PJ Jr, Klemme WR, Dhawan A, et al. In vivo accuracy of thoracic pedicle screws. Spine 2001;26:2340-6.
    • (2001) Spine , vol.26 , pp. 2340-2346
    • Belmont Jr, P.J.1    Klemme, W.R.2    Dhawan, A.3
  • 20
    • 0034466194 scopus 로고    scopus 로고
    • Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique
    • Boachie-Adjei O, Girardi FP, Bansal M, et al. Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique. J Spinal Disord 2000;13:496-500.
    • (2000) J Spinal Disord , vol.13 , pp. 496-500
    • Boachie-Adjei, O.1    Girardi, F.P.2    Bansal, M.3
  • 21
    • 0037227158 scopus 로고    scopus 로고
    • Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: Technique and short-term complications
    • Carbone JJ, Tortolani PJ, Quartararo LG. Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: technique and short-term complications. Spine 2003;28:91-7.
    • (2003) Spine , vol.28 , pp. 91-97
    • Carbone, J.J.1    Tortolani, P.J.2    Quartararo, L.G.3
  • 22
    • 0029893644 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement in lumbar vertebrae
    • Castro WHM, Halm H, Jerosch J, et al. Accuracy of pedicle screw placement in lumbar vertebrae. Spine 1996;21:1320-4.
    • (1996) Spine , vol.21 , pp. 1320-1324
    • Castro, W.H.M.1    Halm, H.2    Jerosch, J.3
  • 23
    • 0029044493 scopus 로고
    • Accuracy of pedicle screw placement in lumbar fusion by plain radiographs and CT
    • Farber GL, Place HM, Mazur RA, et al. Accuracy of pedicle screw placement in lumbar fusion by plain radiographs and CT. Spine 1995;20:1494-9.
    • (1995) Spine , vol.20 , pp. 1494-1499
    • Farber, G.L.1    Place, H.M.2    Mazur, R.A.3
  • 24
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine 1990;15:11-4.
    • (1990) Spine , vol.15 , pp. 11-14
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 25
    • 0031438992 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement: A prospective CT-study in 30 consecutive low back patients
    • Laine T, Makitalo K, Schlenzka D, et al. Accuracy of pedicle screw placement: a prospective CT-study in 30 consecutive low back patients. Eur Spine J 1997;7:402-5.
    • (1997) Eur Spine J , vol.7 , pp. 402-405
    • Laine, T.1    Makitalo, K.2    Schlenzka, D.3
  • 26
    • 0031413907 scopus 로고    scopus 로고
    • Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis
    • Liljenqvist UR, Halm HF, Link TM. Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine 1997;22:2239-45.
    • (1997) Spine , vol.22 , pp. 2239-2245
    • Liljenqvist, U.R.1    Halm, H.F.2    Link, T.M.3
  • 27
    • 0029773637 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement with the assistance of lateral plain radiography
    • Odgers CJ, Vaccaro AR, Pollack ME, et al. Accuracy of pedicle screw placement with the assistance of lateral plain radiography. J Spinal Disord 1996;9:334-8.
    • (1996) J Spinal Disord , vol.9 , pp. 334-338
    • Odgers, C.J.1    Vaccaro, A.R.2    Pollack, M.E.3
  • 28
    • 0032532465 scopus 로고    scopus 로고
    • Clinical relevance of accuracy of pedicle screw placement: A computed tomographic-supported analysis
    • Schulze CJ, Munzinger E, Weber U. Clinical relevance of accuracy of pedicle screw placement: a computed tomographic-supported analysis. Spine 1998;23:2215-21.
    • (1998) Spine , vol.23 , pp. 2215-2221
    • Schulze, C.J.1    Munzinger, E.2    Weber, U.3
  • 29
    • 0029070230 scopus 로고
    • Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis
    • Suk S, Lee CK, Kim WJ, et al. Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine 1995;20:1399-405.
    • (1995) Spine , vol.20 , pp. 1399-1405
    • Suk, S.1    Lee, C.K.2    Kim, W.J.3
  • 30
    • 0029156076 scopus 로고
    • Placement of pedicle screws in the thoracic spine: I. Morphometric analysis of the thoracic vertebrae
    • Vaccaro AR, Rizzolo SJ, Allardyce TJ, et al. Placement of pedicle screws in the thoracic spine: I. Morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 1995;77:1193-9.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1193-1199
    • Vaccaro, A.R.1    Rizzolo, S.J.2    Allardyce, T.J.3
  • 31
    • 0029098570 scopus 로고
    • Placement of pedicle screws in the thoracic spine: II. An anatomical and radiographic assessment
    • Vaccaro AR, Rizzolo SJ, Balderston RA, et al. Placement of pedicle screws in the thoracic spine: II. An anatomical and radiographic assessment. J Bone Joint Surg Am 1995;77:1200-6.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1200-1206
    • Vaccaro, A.R.1    Rizzolo, S.J.2    Balderston, R.A.3
  • 32
    • 0027484342 scopus 로고
    • Complications associated with the technique of pedicle screw fixation: A selected survey of ABS members
    • Esses SI, Barton LS, Vadim D. Complications associated with the technique of pedicle screw fixation: a selected survey of ABS members. Spine 1993;18:2231-9.
    • (1993) Spine , vol.18 , pp. 2231-2239
    • Esses, S.I.1    Barton, L.S.2    Vadim, D.3
  • 34
    • 33644877691 scopus 로고    scopus 로고
    • Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: A CT analysis
    • Rampersaud YR, Pik JHT, Salonen D, et al. Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine 2005;30:E183-90.
    • (2005) Spine , vol.30
    • Rampersaud, Y.R.1    Pik, J.H.T.2    Salonen, D.3
  • 35
    • 0022340141 scopus 로고
    • Quantitative anatomy of the thoracolumbar epidural space
    • Reynolds AF, Roberts A, Pollay M, et al. Quantitative anatomy of the thoracolumbar epidural space. Neurosurgery 1985;17:905-7.
    • (1985) Neurosurgery , vol.17 , pp. 905-907
    • Reynolds, A.F.1    Roberts, A.2    Pollay, M.3
  • 36
    • 0742269914 scopus 로고    scopus 로고
    • Free hand pedicle screw placement in the thoracic spine: Is it safe?
    • Kim YJ, Lenke LG, Bridwell KH, et al. Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 2004;29:333-42.
    • (2004) Spine , vol.29 , pp. 333-342
    • Kim, Y.J.1    Lenke, L.G.2    Bridwell, K.H.3
  • 38
    • 0036726784 scopus 로고    scopus 로고
    • Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement
    • Rao G, Brodke DS, Rondina M, et al. Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement. J Neurosurg 2002;97(suppl 2):223- 6.
    • (2002) J Neurosurg , vol.97 , Issue.SUPPL. 2 , pp. 223-226
    • Rao, G.1    Brodke, D.S.2    Rondina, M.3
  • 39
    • 0031431918 scopus 로고    scopus 로고
    • Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine
    • Yoo JU, Ghanayem A, Petersilge C, et al. Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine. Spine 1997;22:2668-71.
    • (1997) Spine , vol.22 , pp. 2668-2671
    • Yoo, J.U.1    Ghanayem, A.2    Petersilge, C.3
  • 40
    • 0142120104 scopus 로고    scopus 로고
    • Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement [Technical note]
    • Holly LT, Foley KT. Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement [Technical note]. J Neurosurg Spine 2003;99:324-9.
    • (2003) J Neurosurg Spine , vol.99 , pp. 324-329
    • Holly, L.T.1    Foley, K.T.2
  • 41
    • 2342535057 scopus 로고    scopus 로고
    • Intraoperative Iso-C C-arm navigation in craniospinal surgery: The first 60 cases
    • Hott JS, Deshmukh VR, Klopfenstein JD, et al. Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery 2004;54:1131-7.
    • (2004) Neurosurgery , vol.54 , pp. 1131-1137
    • Hott, J.S.1    Deshmukh, V.R.2    Klopfenstein, J.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.