메뉴 건너뛰기




Volumn 53, Issue 2, 2011, Pages 127-138

Non-invasive estimate of blood glucose and blood pressure from a photoplethysmograph by means of machine learning techniques

Author keywords

Blood glucose estimate; Blood pressure estimate; Machine learning; Noninvasive measurement; Photoplethysmography

Indexed keywords

ACTIVITY DETECTION; BLOOD GLUCOSE; BLOOD GLUCOSE LEVEL; CLINICAL USE; CROSS VALIDATION; FUNCTIONAL RELATIONSHIP; GLUCOSE LEVEL; GRADE B; MACHINE LEARNING TECHNIQUES; MACHINE-LEARNING; MULTI-LAYER PERCEPTRON NEURAL NETWORKS; NON-INVASIVE; NONINVASIVE MEASUREMENTS; PHOTOPLETHYSMOGRAPH; PHOTOPLETHYSMOGRAPHY; PRESSURE VALUES; RANDOM FORESTS; WAVE FORMS;

EID: 80052475559     PISSN: 09333657     EISSN: 18732860     Source Type: Journal    
DOI: 10.1016/j.artmed.2011.05.001     Document Type: Article
Times cited : (254)

References (52)
  • 2
    • 0038047699 scopus 로고    scopus 로고
    • Hypertension prevalence and blood pressure levels in 6 European Countries, Canada, and the United States
    • Wolf-Maier K., Cooper R.S., Banegas J.R., Giampaoli S., Hense H-W. Hypertension prevalence and blood pressure levels in 6 European Countries, Canada, and the United States. JAMA 2003, 289(18):2363-2369.
    • (2003) JAMA , vol.289 , Issue.18 , pp. 2363-2369
    • Wolf-Maier, K.1    Cooper, R.S.2    Banegas, J.R.3    Giampaoli, S.4    Hense, H.-W.5
  • 3
    • 84858005571 scopus 로고    scopus 로고
    • Diabetes statistics. American Diabetes Asociation. Last accessed May 2, URL
    • Diabetes statistics. American Diabetes Asociation. Last accessed May 2, 2011. URL http://www.diabetes.org/diabetes-basics/diabetes-statistics.
    • (2011)
  • 4
    • 84858005566 scopus 로고    scopus 로고
    • The pursuit of noninvasive glucose: hunting the deceitful turkey. Last accessed May 2, URL
    • Smith JL. The pursuit of noninvasive glucose: hunting the deceitful turkey. Last accessed May 2, 2011. URL http://www.mendosa.com/noninvasive_glucose.pdf.
    • (2011)
    • Smith, J.L.1
  • 5
    • 85165634569 scopus 로고
    • Reagentless near-infrared determination of glucose in whole blood using multivariate calibration
    • Haaland M., Ries M., Koepp V.T.W., Eaton R. Reagentless near-infrared determination of glucose in whole blood using multivariate calibration. Appl Spectrosc 1992, 46(10):1575-1578.
    • (1992) Appl Spectrosc , vol.46 , Issue.10 , pp. 1575-1578
    • Haaland, M.1    Ries, M.2    Koepp, V.T.W.3    Eaton, R.4
  • 7
    • 0034281859 scopus 로고    scopus 로고
    • Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration
    • Chen W., Kobayashi T., Ichikawa S., Takeuchi Y., Togawa T. Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration. Med Biol Eng Comput 2000, 5:569-574.
    • (2000) Med Biol Eng Comput , vol.5 , pp. 569-574
    • Chen, W.1    Kobayashi, T.2    Ichikawa, S.3    Takeuchi, Y.4    Togawa, T.5
  • 8
    • 34247467602 scopus 로고    scopus 로고
    • Photoplethysmography and its application in clinical physiological measurement
    • Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiol Meas 2007, 28:R1-R39.
    • (2007) Physiol Meas , vol.28
    • Allen, J.1
  • 9
    • 74049131693 scopus 로고    scopus 로고
    • Automatic noninvasive measurement of systolic blood pressure using photoplethysmography
    • Nitzan M., Patron A., Glik Z., Weiss A. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography. BioMed Eng OnLine 2009, 8(1):28.
    • (2009) BioMed Eng OnLine , vol.8 , Issue.1 , pp. 28
    • Nitzan, M.1    Patron, A.2    Glik, Z.3    Weiss, A.4
  • 10
    • 77954269382 scopus 로고    scopus 로고
    • Non-invasive estimation of systolic blood pressure and diastolic blood pressure using photoplethysmograph components
    • Jeong I., Jun S., Um D., Oh K., Yoon H. Non-invasive estimation of systolic blood pressure and diastolic blood pressure using photoplethysmograph components. Yonsei Med J 2010, 51(3):345-353.
    • (2010) Yonsei Med J , vol.51 , Issue.3 , pp. 345-353
    • Jeong, I.1    Jun, S.2    Um, D.3    Oh, K.4    Yoon, H.5
  • 12
    • 84858006115 scopus 로고    scopus 로고
    • ipod (r) digital oximeter. Last accessed May 2, URL
    • ipod (r) digital oximeter. Last accessed May 2, 2011. URL http://www.nonin.com/OEMSolutions/iPod.
    • (2011)
  • 13
    • 84858006114 scopus 로고    scopus 로고
    • Accu-chek aviva. Last accessed May 2,URL
    • Accu-chek aviva. Last accessed May 2, 2011. URL https://www.accu-chek.com/us/glucose-meters/aviva.html.
    • (2011)
  • 14
    • 0035024492 scopus 로고    scopus 로고
    • Blood viscosity and blood pressure: role of temperature and hyperglycemia
    • Yildirim C., Mete S., Kamber D. Blood viscosity and blood pressure: role of temperature and hyperglycemia. Am J Hypertens 2001, 14(5):433-438.
    • (2001) Am J Hypertens , vol.14 , Issue.5 , pp. 433-438
    • Yildirim, C.1    Mete, S.2    Kamber, D.3
  • 15
    • 0036785535 scopus 로고    scopus 로고
    • Arterial baroreflex function and cardiovascular variability: interactions and implications
    • Lanfranchi P.A., Somers V.K. Arterial baroreflex function and cardiovascular variability: interactions and implications. Am J Physiol Regul Integr Comp Physiol 2002, 283(4):815-826.
    • (2002) Am J Physiol Regul Integr Comp Physiol , vol.283 , Issue.4 , pp. 815-826
    • Lanfranchi, P.A.1    Somers, V.K.2
  • 16
    • 0030272423 scopus 로고    scopus 로고
    • Modeling of cardiovascular variability using a differential delay equation
    • Cavalcanti S., Belardinelli E. Modeling of cardiovascular variability using a differential delay equation. IEEE Trans Biomed Eng 1996, 43(10):982-989.
    • (1996) IEEE Trans Biomed Eng , vol.43 , Issue.10 , pp. 982-989
    • Cavalcanti, S.1    Belardinelli, E.2
  • 17
    • 0028152164 scopus 로고
    • Baroreflex modulation of blood pressure and heart rate variabilities in rats: assessment by spectral analysis
    • Cerutti C., Barres C., Paultre C. Baroreflex modulation of blood pressure and heart rate variabilities in rats: assessment by spectral analysis. Am J Physiol Heart Circ Physiol 1994, 266(5):H1993-H2000.
    • (1994) Am J Physiol Heart Circ Physiol , vol.266 , Issue.5
    • Cerutti, C.1    Barres, C.2    Paultre, C.3
  • 19
    • 0023622017 scopus 로고
    • Hemodynamic fluctuations and baroreflex sensitivity in humans: a beat-to-beat model
    • deBoer R.W., Karemaker J.M., Strackee J. Hemodynamic fluctuations and baroreflex sensitivity in humans: a beat-to-beat model. Am J Physiol Heart Circ Physiol 1987, 253(3):680-689.
    • (1987) Am J Physiol Heart Circ Physiol , vol.253 , Issue.3 , pp. 680-689
    • deBoer, R.W.1    Karemaker, J.M.2    Strackee, J.3
  • 21
    • 65549137628 scopus 로고    scopus 로고
    • Baroreflex contribution to blood pressure and heart rate oscillations: time scales, time-variant characteristics and nonlinearities
    • Di Rienzo M., Parati G., Radaelli A., Castiglioni P. Baroreflex contribution to blood pressure and heart rate oscillations: time scales, time-variant characteristics and nonlinearities. Philos Trans R Soc A: Math Phys Eng Sci 2009, 367(1892):1301-1318.
    • (2009) Philos Trans R Soc A: Math Phys Eng Sci , vol.367 , Issue.1892 , pp. 1301-1318
    • Di Rienzo, M.1    Parati, G.2    Radaelli, A.3    Castiglioni, P.4
  • 23
    • 0032972916 scopus 로고    scopus 로고
    • Noninvasive exploration of cardiac autonomic neuropathy. Four reliable methods for diabetes?
    • Ducher M., Cerutti C., Gustin M.P., Abou-Amara S., Thivolet C., Laville M,., et al. Noninvasive exploration of cardiac autonomic neuropathy. Four reliable methods for diabetes?. Diabetes Care 1999, 22(3):388-393.
    • (1999) Diabetes Care , vol.22 , Issue.3 , pp. 388-393
    • Ducher, M.1    Cerutti, C.2    Gustin, M.P.3    Abou-Amara, S.4    Thivolet, C.5    Laville, M.6
  • 25
    • 0034454682 scopus 로고    scopus 로고
    • How do glucocorticoids influence stress responses? Integrating permissive, suppressive, stimulatory, and preparative actions
    • Sapolsky R.M., Romero L.M., Munck A.U. How do glucocorticoids influence stress responses? Integrating permissive, suppressive, stimulatory, and preparative actions. Endocr Rev 2000, 21(1):55-89.
    • (2000) Endocr Rev , vol.21 , Issue.1 , pp. 55-89
    • Sapolsky, R.M.1    Romero, L.M.2    Munck, A.U.3
  • 26
    • 0028792030 scopus 로고
    • The effects of emotions on short-term power spectrum analysis of heart rate variability
    • McCraty R., Atkinson M., Tiller W.A., Rein G., Watkins A.D. The effects of emotions on short-term power spectrum analysis of heart rate variability. Am J Cardiol 1995, 76(14):1089-1093.
    • (1995) Am J Cardiol , vol.76 , Issue.14 , pp. 1089-1093
    • McCraty, R.1    Atkinson, M.2    Tiller, W.A.3    Rein, G.4    Watkins, A.D.5
  • 28
    • 16644391818 scopus 로고    scopus 로고
    • Graded blood pressure reduction in hypertensive outpatients associated with use of a device to assist with slow breathing
    • Elliot W., Izzo J., White W., Rosing D., Snyder C., Alter A,., et al. Graded blood pressure reduction in hypertensive outpatients associated with use of a device to assist with slow breathing. J Clin Hypertens 2004, 10(6):553-559.
    • (2004) J Clin Hypertens , vol.10 , Issue.6 , pp. 553-559
    • Elliot, W.1    Izzo, J.2    White, W.3    Rosing, D.4    Snyder, C.5    Alter, A.6
  • 29
    • 79951718637 scopus 로고    scopus 로고
    • High blood pressure reduction in diabetics with interactive device-guided paced breathing: final results of a randomized controlled study
    • Schein M., Alter A., Levine S., Baevsky T., Nessing A., Gavish B. High blood pressure reduction in diabetics with interactive device-guided paced breathing: final results of a randomized controlled study. J Hypertens 2007, 25(2):292.
    • (2007) J Hypertens , vol.25 , Issue.2 , pp. 292
    • Schein, M.1    Alter, A.2    Levine, S.3    Baevsky, T.4    Nessing, A.5    Gavish, B.6
  • 30
    • 0344121909 scopus 로고    scopus 로고
    • Standard pulse oximeters can be used to monitor respiratory rate
    • Leonard P., Beattie T.F., Addison P.S., Watson J.N. Standard pulse oximeters can be used to monitor respiratory rate. Emerg Med J 2003, 20(6):524-525.
    • (2003) Emerg Med J , vol.20 , Issue.6 , pp. 524-525
    • Leonard, P.1    Beattie, T.F.2    Addison, P.S.3    Watson, J.N.4
  • 35
    • 0036508040 scopus 로고    scopus 로고
    • Robust endpoint detection and energy normalization for real-time speech and speaker recognition
    • Li Q., Zheng J., Tsai A., Zhou Q. Robust endpoint detection and energy normalization for real-time speech and speaker recognition. IEEE Trans Speech Audio Process 2002, 10(3):146-157.
    • (2002) IEEE Trans Speech Audio Process , vol.10 , Issue.3 , pp. 146-157
    • Li, Q.1    Zheng, J.2    Tsai, A.3    Zhou, Q.4
  • 37
    • 85009078216 scopus 로고    scopus 로고
    • Entropy based voice activity detection in very noisy conditions. In: Dalsgaard P, Lindberg B, Benner H, Tan Z-H, editors. In: EUROSPEECH-2001. Aalborg, Denmark.
    • Renevey P, Drygajlo A. Entropy based voice activity detection in very noisy conditions. In: Dalsgaard P, Lindberg B, Benner H, Tan Z-H, editors. In: EUROSPEECH-2001. Aalborg, Denmark; 2001:1887-1890.
    • (2001) , pp. 1887-1890
    • Renevey, P.1    Drygajlo, A.2
  • 38
    • 77951493947 scopus 로고    scopus 로고
    • Robust entropy-based endpoint detection for speech recognition in noisy environments
    • Australasian Speech Science and Technology Association
    • Shen J-L., Hung J-W., Lee L-S. Robust entropy-based endpoint detection for speech recognition in noisy environments. Proc. ICSLP98 1998, 1015-1018. Australasian Speech Science and Technology Association.
    • (1998) Proc. ICSLP98 , pp. 1015-1018
    • Shen, J.-L.1    Hung, J.-W.2    Lee, L.-S.3
  • 39
    • 33645755636 scopus 로고    scopus 로고
    • A fully automated algorithm for the determination of respiratory rate from the photoplethysmogram
    • February
    • Leonard P., Douglas J., Grubb N., Clifton D., Addison P., Watson J. A fully automated algorithm for the determination of respiratory rate from the photoplethysmogram. J Clin Monit Comput 2006, 20(February 4):33-36.
    • (2006) J Clin Monit Comput , vol.20 , Issue.4 , pp. 33-36
    • Leonard, P.1    Douglas, J.2    Grubb, N.3    Clifton, D.4    Addison, P.5    Watson, J.6
  • 40
    • 0034276320 scopus 로고    scopus 로고
    • Randomizing outputs to increase prediction accuracy
    • Breiman L. Randomizing outputs to increase prediction accuracy. Machine Learn 2000, 40(3):229-242.
    • (2000) Machine Learn , vol.40 , Issue.3 , pp. 229-242
    • Breiman, L.1
  • 43
    • 0001011612 scopus 로고
    • Learning from hints in neural networks
    • Abu-Mostafa Y.S. Learning from hints in neural networks. J Complex 1990, 6:192-198.
    • (1990) J Complex , vol.6 , pp. 192-198
    • Abu-Mostafa, Y.S.1
  • 45
    • 84858005567 scopus 로고    scopus 로고
    • SVM and kernel methods matlab toolbox. Perception Systmes et Information. INSA de Rouen. Rouen, France; Last accessed May 2, 2011. URL .
    • Canu S, Grandvalet Y, Guigue V, Rakotomamonjy A, SVM and kernel methods matlab toolbox. Perception Systmes et Information. INSA de Rouen. Rouen, France; 2005. Last accessed May 2, 2011. URL http://asi.insa-rouen.fr/enseignants/arakotom/toolbox/index.html.
    • (2005)
    • Canu, S.1    Grandvalet, Y.2    Guigue, V.3    Rakotomamonjy, A.4
  • 47
    • 0035478854 scopus 로고    scopus 로고
    • Random forests
    • Breiman L. Random forests. Machine Learn 2001, 45(1):5-32.
    • (2001) Machine Learn , vol.45 , Issue.1 , pp. 5-32
    • Breiman, L.1
  • 48
    • 0035799041 scopus 로고    scopus 로고
    • Blood pressure measuring devices: recommendations of the European Society of Hypertension
    • O'Brien E., Waeber B., Parati G., Staessen J., Myers M.G. Blood pressure measuring devices: recommendations of the European Society of Hypertension. Br Med J 2001, 322(7285):531-536.
    • (2001) Br Med J , vol.322 , Issue.7285 , pp. 531-536
    • O'Brien, E.1    Waeber, B.2    Parati, G.3    Staessen, J.4    Myers, M.G.5
  • 49
    • 0023205574 scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose
    • Clarke W.L., Cox D., Gonder-Frederick L.A., Carter W., Pohl S.L. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 1987, 10(5):622-628.
    • (1987) Diabetes Care , vol.10 , Issue.5 , pp. 622-628
    • Clarke, W.L.1    Cox, D.2    Gonder-Frederick, L.A.3    Carter, W.4    Pohl, S.L.5
  • 50
    • 84858002966 scopus 로고    scopus 로고
    • Clarke error grid analysis; 2008. matlabcentral fileexchange. Last accessed May 2, URL .
    • Codina EG, Clarke error grid analysis; 2008. matlabcentral fileexchange. Last accessed May 2, 2011. URL http://www.mathworks.com/matlabcentral/fileexchange/20545-clarke-error-grid-analysis.
    • (2011)
    • Codina, E.G.1
  • 51
    • 84858006111 scopus 로고    scopus 로고
    • Descripción de un sistema para estimar el nivel de glucosa y de presión sanguínea a partir de las medidas de un pulsioximetro e información auxiliar. Internal Report 252 Mon. Universitat Politècnica de Catalunya. Barcelona, Spain; (June).
    • Monte E. Descripción de un sistema para estimar el nivel de glucosa y de presión sanguínea a partir de las medidas de un pulsioximetro e información auxiliar. Internal Report 252 Mon. Universitat Politècnica de Catalunya. Barcelona, Spain; 2008 (June).
    • (2008)
    • Monte, E.1
  • 52
    • 84858005568 scopus 로고    scopus 로고
    • Validated blood pressure monitors. Last accessed May 2, URL
    • Validated blood pressure monitors. Last accessed May 2, 2011. URL http://www.bhsoc.org/blood_pressure_list.stm.
    • (2011)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.