메뉴 건너뛰기




Volumn 51, Issue 3, 2010, Pages 345-353

Non-invasive estimation of systolic blood pressure and diastolic blood pressure using photoplethysmograph components

Author keywords

Blood volume; Cardiovascular system; Dopamine; Epinephrine; Invasive blood pressure; Photoplethysmography; Vascular resistance and compliance

Indexed keywords

ADRENALIN; DOPAMINE; ENFLURANE; KETAMINE;

EID: 77954269382     PISSN: 05135796     EISSN: None     Source Type: Journal    
DOI: 10.3349/ymj.2010.51.3.345     Document Type: Article
Times cited : (28)

References (31)
  • 1
    • 0035857984 scopus 로고    scopus 로고
    • ABC of hypertension: The pathophysiology of hypertension
    • Beevers G, Lip GY, O'Brien E. ABC of hypertension: The pathophysiology of hypertension. BMJ 2001;322:912-916.
    • (2001) BMJ , vol.322 , pp. 912-916
    • Beevers, G.1    Lip, G.Y.2    O'Brien, E.3
  • 2
    • 19944429836 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurement in humans and experimental animals: Part 1: Blood pressure easurement in humans: A statement for professionals from the subcommittee of professional and public education of the merican heart association council on high blood pressure esearch
    • Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure easurement in humans: a statement for professionals from the subcommittee of Professional and Public Education of the merican Heart Association Council on High Blood Pressure esearch. Hypertension 2005;45:142-161.
    • (2005) Hypertension , vol.45 , pp. 142-161
    • Pickering, T.G.1    Hall, J.E.2    Appel, L.J.3    Falkner, B.E.4    Graves, J.5    Hill, M.N.6
  • 4
    • 0033863524 scopus 로고    scopus 로고
    • Similarity in bilateral photoplethysmographic peripheral pulse wave characteristics at the ears, thumbs and toes
    • Allen J, Murray A. Similarity in bilateral photoplethysmographic peripheral pulse wave characteristics at the ears, thumbs and toes. Physiol Meas 2000;21:369-77.
    • (2000) Physiol Meas , vol.21 , pp. 369-377
    • Allen, J.1    Murray, A.2
  • 5
    • 34247467602 scopus 로고    scopus 로고
    • Photoplethysmography and its application in clinical hysiological measurement
    • Allen J. Photoplethysmography and its application in clinical hysiological measurement. Physiol Meas 2007;28:R1-R39.
    • (2007) Physiol Meas , vol.28
    • Allen, J.1
  • 6
    • 0038519373 scopus 로고    scopus 로고
    • Respiratory variations in the eflection mode photoplethysmographic signal. Relationships to eripheral venous pressure
    • Nilsson L, Johansson A, Kalman S. Respiratory variations in the eflection mode photoplethysmographic signal. Relationships to eripheral venous pressure. Med Biol Eng Comput 2003;41:249-254.
    • (2003) Med Biol Eng Comput , vol.41 , pp. 249-254
    • Nilsson, L.1    Johansson, A.2    Kalman, S.3
  • 8
    • 0031735703 scopus 로고    scopus 로고
    • Simultaneous measurement of the photoplethysmographic signal variability in the right and left hands
    • Nitzan M, Vatine JJ, Babchenko A, Khanokh B, Tsenter J, tessman J. Simultaneous measurement of the photoplethysmographic signal variability in the right and left hands. Lasers Med ci 1998;13:189-195.
    • (1998) Lasers Med Ci , vol.13 , pp. 189-195
    • Nitzan, M.1    Vatine, J.J.2    Babchenko, A.3    Khanokh, B.4    Tsenter, J.5    Tessman, J.6
  • 9
    • 18744416257 scopus 로고    scopus 로고
    • An optical device to measure blood omponents by a photoplethysmographic method
    • Kraitl J, Ewald H, Gehring H. An optical device to measure blood omponents by a photoplethysmographic method. J Pure Appl pt 2005;7:S318-S324.
    • (2005) J Pure Appl Pt , vol.7
    • Kraitl, J.1    Ewald, H.2    Gehring, H.3
  • 10
    • 7044223006 scopus 로고    scopus 로고
    • The effect of contacting force on photoplethysmographic signals
    • Teng XF, Zhang YT. The effect of contacting force on photoplethysmographic signals. Physiol Meas 2004;25:1323-1335.
    • (2004) Physiol Meas , vol.25 , pp. 1323-1335
    • Teng, X.F.1    Zhang, Y.T.2
  • 11
    • 0026709388 scopus 로고
    • The role of epinephrine, norepinephrine,and dopamine in blood pressure disturbances in patients with pheochromocytoma
    • Ito Y, Fujimoto Y, Obara T. The role of epinephrine, norepinephrine,and dopamine in blood pressure disturbances in patients with pheochromocytoma. World J Surg 1992;16:759-763.
    • (1992) World J Surg , vol.16 , pp. 759-763
    • Ito, Y.1    Fujimoto, Y.2    Obara, T.3
  • 13
    • 0038047593 scopus 로고    scopus 로고
    • Effects of dopamine, norepinephrine, and epinephrine on the splanchnic circulation in septic shock: Which is best?
    • De Backer D, Creteur J, Silva E, Vincent JL. Effects of dopamine, norepinephrine, and epinephrine on the splanchnic circulation in septic shock: which is best? Crit Care Med 2003;31:1659-1667.
    • (2003) Crit Care Med , vol.31 , pp. 1659-1667
    • de Backer, D.1    Creteur, J.2    Silva, E.3    Vincent, J.L.4
  • 14
    • 0026410742 scopus 로고
    • Peripheral dopamine in pathophysiology of hypertension. Interaction with aging and lifestyle
    • Kuchel OG, Kuchel GA. Peripheral dopamine in pathophysiology of hypertension. Interaction with aging and lifestyle. Hypertension 1991;18:709-721.
    • (1991) Hypertension , vol.18 , pp. 709-721
    • Kuchel, O.G.1    Kuchel, G.A.2
  • 16
    • 0025900322 scopus 로고
    • Dopamine receptor agonists in cardiovascular medicine
    • Horn PT, Murphy MB. Dopamine receptor agonists in cardiovascular medicine. Trends Cardiovasc Med 1991;1:103-107.
    • (1991) Trends Cardiovasc Med , vol.1 , pp. 103-107
    • Horn, P.T.1    Murphy, M.B.2
  • 17
    • 0025177388 scopus 로고
    • Dopamine and dopamine receptor agonists in cardiovascular therapy
    • Murphy MB, Elliott WJ. Dopamine and dopamine receptor agonists in cardiovascular therapy. Crit Care Med 1990;18:S14-S18.
    • (1990) Crit Care Med , vol.18
    • Murphy, M.B.1    Elliott, W.J.2
  • 21
    • 0014290804 scopus 로고
    • Responses of the superficial limb veins of the dog to changes in temperature
    • Webb-Peploe MM, Shepherd JT. Responses of the superficial limb veins of the dog to changes in temperature. Circ Res 1968; 22:737-746.
    • (1968) Circ Res , vol.22 , pp. 737-746
    • Webb-Peploe, M.M.1    Shepherd, J.T.2
  • 26
    • 0032902259 scopus 로고    scopus 로고
    • Very low frequency variability in arterial blood pressure and blood volume pulse
    • Nitzan M, Babchenko A, Khanokh B. Very low frequency variability in arterial blood pressure and blood volume pulse. Med Biol Eng Comput 1999;37:54-58.
    • (1999) Med Biol Eng Comput , vol.37 , pp. 54-58
    • Nitzan, M.1    Babchenko, A.2    Khanokh, B.3
  • 27
    • 0029828436 scopus 로고    scopus 로고
    • Estimation of arterial blood pressure variability by spectral analysis: Comparison between finapres and invasive measurements
    • Pinna GD, Maestri R, Mortara A. Estimation of arterial blood pressure variability by spectral analysis: comparison between Finapres and invasive measurements. Physiol Meas 1996;17:147-149.
    • (1996) Physiol Meas , vol.17 , pp. 147-149
    • Pinna, G.D.1    Maestri, R.2    Mortara, A.3
  • 28
    • 16044371643 scopus 로고    scopus 로고
    • Finger arterial pressure measurement with finapres
    • Wesseling KH. Finger arterial pressure measurement with Finapres. Z Kardiol 1996;85 Suppl 3:38-44.
    • (1996) Z Kardiol , vol.85 , Issue.3 SUPPL. , pp. 38-44
    • Wesseling, K.H.1
  • 29
    • 0032887875 scopus 로고    scopus 로고
    • The effect of increasing blood pressure with dopamine on systemic, splanchnic, and lower extremity hemodynamics in patients with acute liver failure
    • Clemmesen JO, Galatius S, Skak C, Dalgaard P, Larsen FS, Ott P. The effect of increasing blood pressure with dopamine on systemic, splanchnic, and lower extremity hemodynamics in patients with acute liver failure. Scand J Gastroenterol 1999; 34:921-927.
    • (1999) Scand J Gastroenterol , vol.34 , pp. 921-927
    • Clemmesen, J.O.1    Galatius, S.2    Skak, C.3    Dalgaard, P.4    Larsen, F.S.5    Ott, P.6
  • 30
    • 33846898788 scopus 로고    scopus 로고
    • Calibration of the photoplethysmogram to arterial blood pressure: Capabilities and limitations for continuous pressure monitoring
    • Shaltis P, Reisner A, Asada H. Calibration of the photoplethysmogram to arterial blood pressure: capabilities and limitations for continuous pressure monitoring. Conf Proc IEEE Eng Med Biol Soc 2005;3970-3973.
    • (2005) Conf Proc IEEE Eng Med Biol Soc , pp. 3970-3973
    • Shaltis, P.1    Reisner, A.2    Asada, H.3
  • 31
    • 12244304832 scopus 로고    scopus 로고
    • Pulse wave velocity and the second derivative of the finger photoplethysmogram in treated hypertensive patients: Their relationship and associating factors
    • Hashimoto J, Chonan K, Aoki Y, Nishimura T, Ohkubo T, Hozawa A, et al. Pulse wave velocity and the second derivative of the finger photoplethysmogram in treated hypertensive patients: their relationship and associating factors. J Hypertens 2002;20: 2415-2422.
    • (2002) J Hypertens , vol.20 , pp. 2415-2422
    • Hashimoto, J.1    Chonan, K.2    Aoki, Y.3    Nishimura, T.4    Ohkubo, T.5    Hozawa, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.