메뉴 건너뛰기




Volumn 49, Issue 5, 2011, Pages 1053-1069

Radiation, Thoracic Imaging, and Children: Radiation Safety

Author keywords

Computed tomography; Infants and children; Radiation dose; Radiation risk

Indexed keywords

ACUTE GRANULOCYTIC LEUKEMIA; ACUTE LYMPHOBLASTIC LEUKEMIA; ANGIOGRAPHY; ASTROCYTOMA; BRAIN TUMOR; COMPUTER ASSISTED RADIOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC IMAGING; DIGITAL RADIOGRAPHY; DOSIMETRY; ECHOGRAPHY; EWING SARCOMA; FLUOROSCOPY; HUMAN; IMAGE QUALITY; IONIZING RADIATION; LEUKEMIA; LYMPHOMA; MULTIDETECTOR COMPUTED TOMOGRAPHY; NEUROBLASTOMA; NEUROECTODERM TUMOR; NUCLEAR MAGNETIC RESONANCE IMAGING; OSTEOSARCOMA; PRIORITY JOURNAL; RADIATION CARCINOGENESIS; RADIATION DOSE; RADIATION EXPOSURE; RADIATION HAZARD; RADIATION PROTECTION; RADIATION SAFETY; RADIOSENSITIVITY; REVIEW; RISK REDUCTION;

EID: 80052288985     PISSN: 00338389     EISSN: 15578275     Source Type: Journal    
DOI: 10.1016/j.rcl.2011.06.003     Document Type: Review
Times cited : (27)

References (69)
  • 1
    • 79955558376 scopus 로고    scopus 로고
    • Use of medical imaging procedures with ionizing radiation in children
    • Dorfman A.L., Fazel R., Einstein A.J., et al. Use of medical imaging procedures with ionizing radiation in children. Arch Pediatr Adolesc Med 2011, 165:458-464.
    • (2011) Arch Pediatr Adolesc Med , vol.165 , pp. 458-464
    • Dorfman, A.L.1    Fazel, R.2    Einstein, A.J.3
  • 2
    • 79952299747 scopus 로고    scopus 로고
    • Managing radiation use in medical imaging: a multifaceted challenge
    • Hricak H., Brenner D.J., Adelstein S.J., et al. Managing radiation use in medical imaging: a multifaceted challenge. Radiology 2010, 258:889-905.
    • (2010) Radiology , vol.258 , pp. 889-905
    • Hricak, H.1    Brenner, D.J.2    Adelstein, S.J.3
  • 3
    • 72049125581 scopus 로고    scopus 로고
    • The association between hospital outcomes and diagnostic imaging: early findings
    • Lee D., Foster D. The association between hospital outcomes and diagnostic imaging: early findings. J Am Coll Radiol 2009, 6:780-785.
    • (2009) J Am Coll Radiol , vol.6 , pp. 780-785
    • Lee, D.1    Foster, D.2
  • 4
    • 77950620860 scopus 로고    scopus 로고
    • Multidetector computed tomography and 3-dimensional imaging: preoperative evaluation of thoracic vascular and tracheobronchial anomalies and abnormalities in pediatric patients
    • Lee E., Boiselle P., Shamberger R. Multidetector computed tomography and 3-dimensional imaging: preoperative evaluation of thoracic vascular and tracheobronchial anomalies and abnormalities in pediatric patients. J Pediatr Surg 2010, 45(4):811-821.
    • (2010) J Pediatr Surg , vol.45 , Issue.4 , pp. 811-821
    • Lee, E.1    Boiselle, P.2    Shamberger, R.3
  • 5
    • 77956020491 scopus 로고    scopus 로고
    • Computed tomography of pediatric cardiovascular disease
    • Siegel M.J. Computed tomography of pediatric cardiovascular disease. J Thorac Imaging 2010, 25:256-266.
    • (2010) J Thorac Imaging , vol.25 , pp. 256-266
    • Siegel, M.J.1
  • 6
    • 65649131164 scopus 로고    scopus 로고
    • Thoracic cardiovascular CT: technique and applications
    • Frush D.P. Thoracic cardiovascular CT: technique and applications. Pediatr Radiol 2009, 39(3):464-470.
    • (2009) Pediatr Radiol , vol.39 , Issue.3 , pp. 464-470
    • Frush, D.P.1
  • 7
    • 77957344632 scopus 로고    scopus 로고
    • Addressing overutilization in medical imaging
    • Hendee W.R., Becker G.J., Borgstede J.P., et al. Addressing overutilization in medical imaging. Radiology 2010, 257:240-245.
    • (2010) Radiology , vol.257 , pp. 240-245
    • Hendee, W.R.1    Becker, G.J.2    Borgstede, J.P.3
  • 8
    • 64949091695 scopus 로고    scopus 로고
    • Effect of computerized order entry with integrated decision support on the growth of outpatient procedure volumes: seven-year time series
    • Sistrom C.L., Dang P.A., Weilburg J.B., et al. Effect of computerized order entry with integrated decision support on the growth of outpatient procedure volumes: seven-year time series. Radiology 2009, 251:147-155.
    • (2009) Radiology , vol.251 , pp. 147-155
    • Sistrom, C.L.1    Dang, P.A.2    Weilburg, J.B.3
  • 9
    • 77958544804 scopus 로고    scopus 로고
    • Clinical radiation management for fluoroscopically guided interventional procedures
    • Miller D., Balter S., Schueler B., et al. Clinical radiation management for fluoroscopically guided interventional procedures. Radiology 2010, 257(2):321-332.
    • (2010) Radiology , vol.257 , Issue.2 , pp. 321-332
    • Miller, D.1    Balter, S.2    Schueler, B.3
  • 10
    • 80052278116 scopus 로고    scopus 로고
    • Available at: Accessed January 19
    • Available at: Accessed January 19, 2011. http://www.nytimes.com/2010/11/23/us/23scan.html?_r=1&pagewanted=allNY.
    • (2011)
  • 11
    • 80052302821 scopus 로고    scopus 로고
    • Available at: Accessed January 19
    • Available at: Accessed January 19, 2011. http://www.nytimes.com/2009/10/16/us/16radiation.html.
    • (2011)
  • 12
    • 0032621833 scopus 로고    scopus 로고
    • The right place at the wrong time: historical perspective of the relation of the thymus gland and pediatric radiology
    • Jacobs M.T., Frush D.P., Donnelly L.F. The right place at the wrong time: historical perspective of the relation of the thymus gland and pediatric radiology. Radiology 1999, 210:11-16.
    • (1999) Radiology , vol.210 , pp. 11-16
    • Jacobs, M.T.1    Frush, D.P.2    Donnelly, L.F.3
  • 13
    • 78649999084 scopus 로고    scopus 로고
    • Thyroid cancer risk 40+ years after irradiation for an enlarged thymus: an update of the Hempelmann cohort
    • Adams M.J., Shore R.D., Dozier A.L., et al. Thyroid cancer risk 40+ years after irradiation for an enlarged thymus: an update of the Hempelmann cohort. Radiat Res 2010, 174:753-762.
    • (2010) Radiat Res , vol.174 , pp. 753-762
    • Adams, M.J.1    Shore, R.D.2    Dozier, A.L.3
  • 14
    • 74549155691 scopus 로고    scopus 로고
    • Breast cancer risk 55+ years after irradiation for an enlarged thymus and its implications for early childhood medical irradiation today
    • Adams M.J., Shore R.D., Dozier A.L., et al. Breast cancer risk 55+ years after irradiation for an enlarged thymus and its implications for early childhood medical irradiation today. Cancer Epidemiol Biomarkers Prev 2010, 19:48-58.
    • (2010) Cancer Epidemiol Biomarkers Prev , vol.19 , pp. 48-58
    • Adams, M.J.1    Shore, R.D.2    Dozier, A.L.3
  • 15
    • 80052289205 scopus 로고
    • Q & A
    • Consum Rep September 1961, 493-501. Q & A.
    • (1961) Consum Rep , pp. 493-501
  • 16
    • 0035141920 scopus 로고    scopus 로고
    • Helical CT of the body: are settings adjusted for pediatric patients?
    • Paterson A., Frush D.P., Donnelly L.F. Helical CT of the body: are settings adjusted for pediatric patients?. Am J Roentgenol 2001, 176:297-301.
    • (2001) Am J Roentgenol , vol.176 , pp. 297-301
    • Paterson, A.1    Frush, D.P.2    Donnelly, L.F.3
  • 17
    • 0035142347 scopus 로고    scopus 로고
    • Taking care of children: check out the parameters used for helical CT
    • Rogers L.F. Taking care of children: check out the parameters used for helical CT. Am J Roentgenol 2001, 176:287-288.
    • (2001) Am J Roentgenol , vol.176 , pp. 287-288
    • Rogers, L.F.1
  • 18
    • 80052284615 scopus 로고    scopus 로고
    • Health devices: top ten health technology hazards for 2011. ECRI Institute: the discipline of science. The integrity of independence.
    • Health devices: top ten health technology hazards for 2011. ECRI Institute: the discipline of science. The integrity of independence. 2010; 39(11):386-98.
    • (2010) , vol.39 , Issue.11 , pp. 386-98
  • 19
    • 80052283068 scopus 로고    scopus 로고
    • Available at: Accessed February 7
    • Available at: Accessed February 7, 2011. http://www.acr.org/HomePageCategories/News/ACRNewsCenter/California-State-Senate-Bill-1237.aspx.
    • (2011)
  • 21
    • 84928096038 scopus 로고    scopus 로고
    • Computed tomography and radiation: understanding the issues
    • Frush D.P., Applegate K. Computed tomography and radiation: understanding the issues. J Am Coll Radiol 2004, 1:113-119.
    • (2004) J Am Coll Radiol , vol.1 , pp. 113-119
    • Frush, D.P.1    Applegate, K.2
  • 22
    • 77951967054 scopus 로고    scopus 로고
    • Has pediatric CT at Children's hospitals reached its peak?
    • Townsend B.A., Callahan M.J., Zurakowski D., et al. Has pediatric CT at Children's hospitals reached its peak?. AJR Am J Roentgenol 2010, 194:1194-1196.
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 1194-1196
    • Townsend, B.A.1    Callahan, M.J.2    Zurakowski, D.3
  • 23
    • 34548184941 scopus 로고    scopus 로고
    • Increasing utilization of computed tomography in the pediatric emergency department, 2000-2006
    • Broder J., Fordham L.A., Warshauer D.M. Increasing utilization of computed tomography in the pediatric emergency department, 2000-2006. Emerg Radiol 2007, 14:227-232.
    • (2007) Emerg Radiol , vol.14 , pp. 227-232
    • Broder, J.1    Fordham, L.A.2    Warshauer, D.M.3
  • 24
    • 79956299842 scopus 로고    scopus 로고
    • Rising use of CT in child visits to the emergency department in the United States, 1995-2008
    • Larson D.B., Johnson L.W., Schnell L.W., et al. Rising use of CT in child visits to the emergency department in the United States, 1995-2008. Radiology 2011, 258(1):793-801.
    • (2011) Radiology , vol.258 , Issue.1 , pp. 793-801
    • Larson, D.B.1    Johnson, L.W.2    Schnell, L.W.3
  • 25
    • 78650609722 scopus 로고    scopus 로고
    • National trends in CT use in the emergency department 1995-2007
    • Larson D.B., Johnson L.W., Schnell L.W., et al. National trends in CT use in the emergency department 1995-2007. Radiology 2011, 258(1):164-173.
    • (2011) Radiology , vol.258 , Issue.1 , pp. 164-173
    • Larson, D.B.1    Johnson, L.W.2    Schnell, L.W.3
  • 27
    • 80052301327 scopus 로고    scopus 로고
    • IAEA training material on radiation protection of children. Available at: Accessed July 30
    • IAEA training material on radiation protection of children. Available at: Accessed July 30, 2011. http://rpop.iaea.org.
    • (2011)
  • 28
    • 43149119002 scopus 로고    scopus 로고
    • Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method
    • Thomas K., Wang B. Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method. Pediatr Radiol 2008, 38:645-656.
    • (2008) Pediatr Radiol , vol.38 , pp. 645-656
    • Thomas, K.1    Wang, B.2
  • 29
    • 47249166093 scopus 로고    scopus 로고
    • Effective doses in radiology and diagnostic nuclear medicine: a catalog
    • Mettler F.A., Huda W., Yoshizumi T.T., et al. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 2008, 248(1):254-256.
    • (2008) Radiology , vol.248 , Issue.1 , pp. 254-256
    • Mettler, F.A.1    Huda, W.2    Yoshizumi, T.T.3
  • 30
    • 34948887091 scopus 로고    scopus 로고
    • Effective dose: how should it be applied to medical exposures?
    • Martin C.J. Effective dose: how should it be applied to medical exposures?. Br J Radiol 2007, 80:639-647.
    • (2007) Br J Radiol , vol.80 , pp. 639-647
    • Martin, C.J.1
  • 31
    • 16644370288 scopus 로고    scopus 로고
    • Radiosensitivity of children: potential for overexposure in CR and DR and magnitude of doses in ordinary radiographic examinations
    • Don S. Radiosensitivity of children: potential for overexposure in CR and DR and magnitude of doses in ordinary radiographic examinations. Pediatr Radiol 2004, 34(3):S167-S172.
    • (2004) Pediatr Radiol , vol.34 , Issue.3
    • Don, S.1
  • 32
    • 34250806587 scopus 로고    scopus 로고
    • Pediatric cardiac-gated CT angiography: assessment of radiation dose
    • Hollingsworth C.L., Frush D.P., Yoshizumi T.T., et al. Pediatric cardiac-gated CT angiography: assessment of radiation dose. AJR Am J Roentgenol 2007, 189(1):12-18.
    • (2007) AJR Am J Roentgenol , vol.189 , Issue.1 , pp. 12-18
    • Hollingsworth, C.L.1    Frush, D.P.2    Yoshizumi, T.T.3
  • 33
    • 49049113873 scopus 로고    scopus 로고
    • CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland
    • Verdun F., Gutierrez D., Vader J., et al. CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland. Eur Radiol 2008, 18:1980-1986.
    • (2008) Eur Radiol , vol.18 , pp. 1980-1986
    • Verdun, F.1    Gutierrez, D.2    Vader, J.3
  • 34
    • 77954192925 scopus 로고    scopus 로고
    • Paediatric CT examinations in 19 developing countries: frequency and radiation dose
    • Muhogora W.E., Ahmed N.A., Alsuwaidi J.S., et al. Paediatric CT examinations in 19 developing countries: frequency and radiation dose. Radiat Prot Dosimetry 2010, 140(1):49-58.
    • (2010) Radiat Prot Dosimetry , vol.140 , Issue.1 , pp. 49-58
    • Muhogora, W.E.1    Ahmed, N.A.2    Alsuwaidi, J.S.3
  • 35
    • 0038480004 scopus 로고    scopus 로고
    • Survey of effective dose levels from typical paediatric CT protocols
    • McLean D., Malitz N., Lewis S. Survey of effective dose levels from typical paediatric CT protocols. Australas Radiol 2003, 47:135-142.
    • (2003) Australas Radiol , vol.47 , pp. 135-142
    • McLean, D.1    Malitz, N.2    Lewis, S.3
  • 36
    • 77950475244 scopus 로고    scopus 로고
    • Radiation oncology organization, FDA announces radiation safety initiatives
    • Hampton T. Radiation oncology organization, FDA announces radiation safety initiatives. JAMA 2010, 303(13):1239-1240.
    • (2010) JAMA , vol.303 , Issue.13 , pp. 1239-1240
    • Hampton, T.1
  • 37
    • 80052292210 scopus 로고    scopus 로고
    • NEMA Standards Publication XR 25-2010.
    • Computed tomography dose check 2010, NEMA Standards Publication XR 25-2010, p. 1-15.
    • (2010) Computed tomography dose check , pp. 1-5
  • 38
    • 63249127591 scopus 로고    scopus 로고
    • Radiation biology for pediatric radiologists
    • Hall E.J. Radiation biology for pediatric radiologists. Pediatr Radiol 2009, 39(1):S57-S64.
    • (2009) Pediatr Radiol , vol.39 , Issue.1
    • Hall, E.J.1
  • 39
    • 80052274748 scopus 로고    scopus 로고
    • Available at: Accessed February 8
    • Available at: Accessed February 8, 2011. http://www.icrp.org/docs/ICRP_Publication_103-Annals_of_the_ICRP_37(2-4)-Free_extract.pdf.
    • (2011)
  • 40
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • Brenner D.J., Elliston C.D., Hall E.J., et al. Estimated risks of radiation-induced fatal cancer from pediatric CT. Am J Roentgenol 2001, 176:289-296.
    • (2001) Am J Roentgenol , vol.176 , pp. 289-296
    • Brenner, D.J.1    Elliston, C.D.2    Hall, E.J.3
  • 41
    • 64949094007 scopus 로고    scopus 로고
    • Risks associated with low doses and low dose rates of ionizing radiation: why linearity may be (almost) the best we can do
    • Little M.P., Wakeford R., Tawn E.J., et al. Risks associated with low doses and low dose rates of ionizing radiation: why linearity may be (almost) the best we can do. Radiology 2009, 251:6-12.
    • (2009) Radiology , vol.251 , pp. 6-12
    • Little, M.P.1    Wakeford, R.2    Tawn, E.J.3
  • 42
    • 64949191402 scopus 로고    scopus 로고
    • The linear no-threshold relationship is inconsistent with radiation biologic and experimental data
    • Tubiana M., Feinendegen L.E., Yang C., et al. The linear no-threshold relationship is inconsistent with radiation biologic and experimental data. Radiology 2009, 251:13-22.
    • (2009) Radiology , vol.251 , pp. 13-22
    • Tubiana, M.1    Feinendegen, L.E.2    Yang, C.3
  • 43
    • 63249126021 scopus 로고    scopus 로고
    • Children's exposure to diagnostic medical radiation and cancer risk: epidemiologic and dosimetric considerations
    • Linet M., Kim K., Rajaraman P. Children's exposure to diagnostic medical radiation and cancer risk: epidemiologic and dosimetric considerations. Pediatr Radiol 2009, 39(1):S4-S26.
    • (2009) Pediatr Radiol , vol.39 , Issue.1
    • Linet, M.1    Kim, K.2    Rajaraman, P.3
  • 44
    • 10744219719 scopus 로고    scopus 로고
    • Cancer risks attributable to low doses of ionizing radiation: assessing what we really know
    • Brenner D.J., Doll R., Goodhead D.T., et al. Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci U S A 2003, 100(24):13761-13766.
    • (2003) Proc Natl Acad Sci U S A , vol.100 , Issue.24 , pp. 13761-13766
    • Brenner, D.J.1    Doll, R.2    Goodhead, D.T.3
  • 45
    • 34548279773 scopus 로고    scopus 로고
    • Excess lifetime cancer mortality risk attributable to radiation exposure from computed tomography examinations in children
    • Chodick G., Ronckers C., Shalew V., et al. Excess lifetime cancer mortality risk attributable to radiation exposure from computed tomography examinations in children. Isr Med Assoc J 2007, 9:584-587.
    • (2007) Isr Med Assoc J , vol.9 , pp. 584-587
    • Chodick, G.1    Ronckers, C.2    Shalew, V.3
  • 46
    • 78649772292 scopus 로고    scopus 로고
    • Diagnostic x-rays and risk of childhood leukaemia
    • Bartley K., Metayer C., Selvin S., et al. Diagnostic x-rays and risk of childhood leukaemia. Int J Epidemiol 2010, 39:1628-1637.
    • (2010) Int J Epidemiol , vol.39 , pp. 1628-1637
    • Bartley, K.1    Metayer, C.2    Selvin, S.3
  • 47
    • 12344309053 scopus 로고    scopus 로고
    • The ALARA concept in pediatric CR and DR: dose reduction in pediatric radiographic exams-a white paper conference executive
    • Willis C., Slovis T. The ALARA concept in pediatric CR and DR: dose reduction in pediatric radiographic exams-a white paper conference executive. Radiology 2005, 234:343-344.
    • (2005) Radiology , vol.234 , pp. 343-344
    • Willis, C.1    Slovis, T.2
  • 48
    • 16644387283 scopus 로고    scopus 로고
    • Strategies for dose reduction in ordinary radiographic examinations using CR and DR
    • Willis C. Strategies for dose reduction in ordinary radiographic examinations using CR and DR. Pediatr Radiol 2004, 34(3):S196-S200.
    • (2004) Pediatr Radiol , vol.34 , Issue.3
    • Willis, C.1
  • 49
    • 54949132544 scopus 로고    scopus 로고
    • The additional dose to radiosensitive organs caused by using under-collimated x-ray beams in neonatal intensive care radiography
    • Datz H., Ben-Shlomo A., Bader D. The additional dose to radiosensitive organs caused by using under-collimated x-ray beams in neonatal intensive care radiography. Radiat Prot Dosimetry 2008, 130(4):518-524.
    • (2008) Radiat Prot Dosimetry , vol.130 , Issue.4 , pp. 518-524
    • Datz, H.1    Ben-Shlomo, A.2    Bader, D.3
  • 50
    • 71849086801 scopus 로고    scopus 로고
    • Chest tomosynthesis: technical principles and clinical update
    • Dobbins J., McAdams H. Chest tomosynthesis: technical principles and clinical update. Eur J Radiol 2009, 72:244-251.
    • (2009) Eur J Radiol , vol.72 , pp. 244-251
    • Dobbins, J.1    McAdams, H.2
  • 51
    • 77958603417 scopus 로고    scopus 로고
    • Image gently, step lightly: promoting radiation safety in pediatric interventional radiology
    • Sidhu M., Goske M.J., Connolly B., et al. Image gently, step lightly: promoting radiation safety in pediatric interventional radiology. AJR Am J Roentgenol 2010, 195:299-301.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 299-301
    • Sidhu, M.1    Goske, M.J.2    Connolly, B.3
  • 52
    • 77954423361 scopus 로고    scopus 로고
    • Multidetector CT in children: current concepts and dose reduction strategies
    • Nievelstein R.A., van Dam I., van der Molen A. Multidetector CT in children: current concepts and dose reduction strategies. Pediatr Radiol 2010, 40:1324-1344.
    • (2010) Pediatr Radiol , vol.40 , pp. 1324-1344
    • Nievelstein, R.A.1    van Dam, I.2    van der Molen, A.3
  • 53
    • 67650077358 scopus 로고    scopus 로고
    • Dose reduction and compliance with pediatric CT protocols adapted to patient size, clinical indication, and number of prior studies
    • Singh S., Kalra M., Moore M., et al. Dose reduction and compliance with pediatric CT protocols adapted to patient size, clinical indication, and number of prior studies. Radiology 2009, 252(1):200-206.
    • (2009) Radiology , vol.252 , Issue.1 , pp. 200-206
    • Singh, S.1    Kalra, M.2    Moore, M.3
  • 54
    • 65649083137 scopus 로고    scopus 로고
    • MDCT in children: scan techniques and contrast issues
    • springer, Italy, Chapter 26, M.K. Kalra, S. Saini, G.D. Rubin (Eds.)
    • Frush D.P. MDCT in children: scan techniques and contrast issues. MDCT from protocols to practice 2008, 333-354. springer, Italy, Chapter 26. M.K. Kalra, S. Saini, G.D. Rubin (Eds.).
    • (2008) MDCT from protocols to practice , pp. 333-354
    • Frush, D.P.1
  • 55
    • 77951958464 scopus 로고    scopus 로고
    • Evaluation of a radiation dose reduction strategy for pediatric chest CT
    • Kim J., Newman B. Evaluation of a radiation dose reduction strategy for pediatric chest CT. AJR Am J Roentgenol 2010, 194:1188-1193.
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 1188-1193
    • Kim, J.1    Newman, B.2
  • 56
    • 66649108047 scopus 로고    scopus 로고
    • Pediatric MDCT: towards assessing the diagnostic influence of dose reduction on the detection of small lung nodules
    • Li X., Samei E., Frush D.P., et al. Pediatric MDCT: towards assessing the diagnostic influence of dose reduction on the detection of small lung nodules. Acad Radiol 2009, 16(7):872-880.
    • (2009) Acad Radiol , vol.16 , Issue.7 , pp. 872-880
    • Li, X.1    Samei, E.2    Frush, D.P.3
  • 57
    • 0043033136 scopus 로고    scopus 로고
    • Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE dose)
    • Greess H., Nomayr A., Wolf H., et al. Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE dose). Eur Radiol 2002, 12:1571-1576.
    • (2002) Eur Radiol , vol.12 , pp. 1571-1576
    • Greess, H.1    Nomayr, A.2    Wolf, H.3
  • 58
    • 0344441737 scopus 로고    scopus 로고
    • Usefulness of a method for changing tube current during helical scanning in multislice CT
    • Kojima M., Itoh S., Ikeda M., et al. Usefulness of a method for changing tube current during helical scanning in multislice CT. Radiat Med 2003, 21:193-204.
    • (2003) Radiat Med , vol.21 , pp. 193-204
    • Kojima, M.1    Itoh, S.2    Ikeda, M.3
  • 59
    • 2942752143 scopus 로고    scopus 로고
    • Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation
    • Grees H., Iutz J., Nomayr A., et al. Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation. Eur Radiol 2003, 14:995-999.
    • (2003) Eur Radiol , vol.14 , pp. 995-999
    • Grees, H.1    Iutz, J.2    Nomayr, A.3
  • 60
    • 73149107026 scopus 로고    scopus 로고
    • Use of automatic tube current modulation with a standardized noise index in young children undergoing chest computed tomography scans with 64-slice multidetector computed tomography
    • Peng Y., Li J., Ma D., et al. Use of automatic tube current modulation with a standardized noise index in young children undergoing chest computed tomography scans with 64-slice multidetector computed tomography. Acta Radiol 2009, 50(10):1175-1181.
    • (2009) Acta Radiol , vol.50 , Issue.10 , pp. 1175-1181
    • Peng, Y.1    Li, J.2    Ma, D.3
  • 61
    • 78650196158 scopus 로고    scopus 로고
    • Bismuth shielding in CT: support for use in children
    • Kim S., Frush D., Yoshizumi T. Bismuth shielding in CT: support for use in children. Pediatr Radiol 2010, 40:1739-1743.
    • (2010) Pediatr Radiol , vol.40 , pp. 1739-1743
    • Kim, S.1    Frush, D.2    Yoshizumi, T.3
  • 62
    • 78650202675 scopus 로고    scopus 로고
    • The use of breast shielding for dose reduction in pediatric CT: arguments against the proposition
    • Geleijns J., Wang J., McCollough C. The use of breast shielding for dose reduction in pediatric CT: arguments against the proposition. Pediatr Radiol 2010, 40(11):1744-1747.
    • (2010) Pediatr Radiol , vol.40 , Issue.11 , pp. 1744-1747
    • Geleijns, J.1    Wang, J.2    McCollough, C.3
  • 64
    • 74749087439 scopus 로고    scopus 로고
    • Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm
    • Silva A.C., Lawder H.J., Hara A., et al. Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol 2010, 194:191-199.
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 191-199
    • Silva, A.C.1    Lawder, H.J.2    Hara, A.3
  • 65
    • 78650910629 scopus 로고    scopus 로고
    • Patient-specific radiation dose and cancer risk estimation in CT: part I. Development and validation of a Monte Carlo Program
    • Li X., Segars P., Frush D.P. Patient-specific radiation dose and cancer risk estimation in CT: part I. Development and validation of a Monte Carlo Program. Med Phys 2011, 38:397-407.
    • (2011) Med Phys , vol.38 , pp. 397-407
    • Li, X.1    Segars, P.2    Frush, D.P.3
  • 66
    • 77956360099 scopus 로고    scopus 로고
    • Tracking radiation exposure of patients
    • Rehani M., Frush D.P. Tracking radiation exposure of patients. Lancet 2011, 376:754-755.
    • (2011) Lancet , vol.376 , pp. 754-755
    • Rehani, M.1    Frush, D.P.2
  • 67
    • 38849188775 scopus 로고    scopus 로고
    • The image gently campaign: working together to change practice
    • Goske M.J., Applegate K.E., Frush D.P., et al. The image gently campaign: working together to change practice. Am J Roentgenol 2008, 190(2):273-274.
    • (2008) Am J Roentgenol , vol.190 , Issue.2 , pp. 273-274
    • Goske, M.J.1    Applegate, K.E.2    Frush, D.P.3
  • 68
    • 77950614409 scopus 로고    scopus 로고
    • Image gently: ten steps you can take to optimize image quality and lower CT dose for pediatric patients
    • Strauss K.J., Goske M.J., Kaste S.C., et al. Image gently: ten steps you can take to optimize image quality and lower CT dose for pediatric patients. AJR Am J Roentgenol 2010, 194:868-873.
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 868-873
    • Strauss, K.J.1    Goske, M.J.2    Kaste, S.C.3
  • 69
    • 78649665790 scopus 로고    scopus 로고
    • Image wisely: a campaign to increase awareness about adult radiation protection
    • Brink J.A., Amis E.S. Image wisely: a campaign to increase awareness about adult radiation protection. Radiology 2010, 257(3):601-602.
    • (2010) Radiology , vol.257 , Issue.3 , pp. 601-602
    • Brink, J.A.1    Amis, E.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.