메뉴 건너뛰기




Volumn 130, Issue 4, 2008, Pages 518-524

The additional dose to radiosensitive organs caused by using under-collimated X-ray beams in neonatal intensive care radiography

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL RADIOGRAPHY; ARTICLE; BONE MARROW; CONTROLLED STUDY; DOSE RESPONSE; DOSIMETRY; FEASIBILITY STUDY; HUMAN; LARGE INTESTINE; LUNG; MAJOR CLINICAL STUDY; MONTE CARLO METHOD; NEWBORN; NEWBORN INTENSIVE CARE; OVARY; RADIATION DOSE; RADIATION EXPOSURE; RADIOSENSITIVITY; STOMACH; TESTIS; THORAX RADIOGRAPHY; THYMUS; THYROID GLAND; X IRRADIATION;

EID: 54949132544     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncn090     Document Type: Article
Times cited : (21)

References (22)
  • 3
    • 0003733263 scopus 로고
    • Recommendations of the International Cominission on Radiological Protection
    • International Commission on Radiological Protection
    • International Commission on Radiological Protection. Recommendations of the International Cominission on Radiological Protection, ICRP Publication 60 (1990).
    • (1990) ICRP Publication , vol.60
  • 5
    • 54949119392 scopus 로고
    • National Research Council Health effects of exposure to low levels of ionizing radiation BEIR V
    • National Research Council Health effects of exposure to low levels of ionizing radiation BEIR V (1990).
    • (1990)
  • 6
    • 15544375367 scopus 로고    scopus 로고
    • Long-term follow-up for brain tumor development following childhood exposure to ionizing radiation for tinea capitis
    • Sadetzki, S., Chetrit, A., Freedman, L., Stovall, M., Modan, B. and Novikov, I. Long-term follow-up for brain tumor development following childhood exposure to ionizing radiation for tinea capitis. Radiat. Res. 163, 424-432 (2005).
    • (2005) Radiat. Res , vol.163 , pp. 424-432
    • Sadetzki, S.1    Chetrit, A.2    Freedman, L.3    Stovall, M.4    Modan, B.5    Novikov, I.6
  • 8
    • 54949096826 scopus 로고    scopus 로고
    • European guidelines on quality criteria for diagnostic radiographic images in paediatrics EUR 16261 EN European Commission
    • European guidelines on quality criteria for diagnostic radiographic images in paediatrics EUR 16261 EN European Commission (1996).
    • (1996)
  • 9
    • 54949094218 scopus 로고
    • World Health Organization Rational use of diagnostic imaging in paediatrics. Report 757
    • World Health Organization Rational use of diagnostic imaging in paediatrics. Report 757 (1987).
    • (1987)
  • 11
    • 54949098001 scopus 로고    scopus 로고
    • Tapioxaara, M., Lakkisto, M. and Servomaa, A. PCXMC, a PC-based Monte Carlo program for calculating patient doses in medical X-ray examinations. STUK-A139 (1997).
    • Tapioxaara, M., Lakkisto, M. and Servomaa, A. PCXMC, a PC-based Monte Carlo program for calculating patient doses in medical X-ray examinations. STUK-A139 (1997).
  • 12
    • 0014525649 scopus 로고
    • Intrauterine growth of live-born Caucasian infants at sea level: Standards obtained from measurements in 7 dimensions of infants born between 25 and 44 weeks of gestation
    • Usher, R. and McLean, F. Intrauterine growth of live-born Caucasian infants at sea level: Standards obtained from measurements in 7 dimensions of infants born between 25 and 44 weeks of gestation. J. Pediatr. 74, 901-910 (1969).
    • (1969) J. Pediatr , vol.74 , pp. 901-910
    • Usher, R.1    McLean, F.2
  • 13
    • 0037278220 scopus 로고    scopus 로고
    • Neonatal doses from X ray examinations by birth weight in a neonatal intensive care unit
    • Ono, K., Akahane, K., Aota, T, Hada, M., Takano, Y, Kai, M. and Kusama, T. Neonatal doses from X ray examinations by birth weight in a neonatal intensive care unit. Radiat. Prot. Dosim. 103, 155-162 (2003).
    • (2003) Radiat. Prot. Dosim , vol.103 , pp. 155-162
    • Ono, K.1    Akahane, K.2    Aota, T.3    Hada, M.4    Takano, Y.5    Kai, M.6    Kusama, T.7
  • 15
    • 0022622880 scopus 로고
    • The risk of diagnostic radiation of the newborn
    • Fletcher, W. L., Baum, J. D. and Draper, G. The risk of diagnostic radiation of the newborn. Br. J. Radiol. 59, 165-170 (1986).
    • (1986) Br. J. Radiol , vol.59 , pp. 165-170
    • Fletcher, W.L.1    Baum, J.D.2    Draper, G.3
  • 16
    • 0036316052 scopus 로고    scopus 로고
    • Radiation dose quantities and risk in neonates in a special care baby unit
    • Armpilia, C. I., Fite, I. A. J. and Croasdale, P. L. Radiation dose quantities and risk in neonates in a special care baby unit. Br. J. Radiol. 75, 590-595 (2002).
    • (2002) Br. J. Radiol , vol.75 , pp. 590-595
    • Armpilia, C.I.1    Fite, I.A.J.2    Croasdale, P.L.3
  • 17
    • 0024559174 scopus 로고
    • Radiation dose to neonates on a special care baby unit
    • Faulkner, K., Barry, J. L. and Smalley, P. Radiation dose to neonates on a special care baby unit. Br. J. Radiol. 52, 230-233 (1989).
    • (1989) Br. J. Radiol , vol.52 , pp. 230-233
    • Faulkner, K.1    Barry, J.L.2    Smalley, P.3
  • 20
    • 0031908617 scopus 로고    scopus 로고
    • Digital radiography in paediatrics: Radiation dose considerations and magnitude of possible dose reduction
    • Hufton, A. P., Doyle, S. M. and Carty, H. M. L. Digital radiography in paediatrics: Radiation dose considerations and magnitude of possible dose reduction. Br. J. Radiol. 71, 186-199 (1998).
    • (1998) Br. J. Radiol , vol.71 , pp. 186-199
    • Hufton, A.P.1    Doyle, S.M.2    Carty, H.M.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.