메뉴 건너뛰기




Volumn 1, Issue 2, 2004, Pages 113-119

Computed tomography and radiation: Understanding the issues

Author keywords

Computed tomography; Practice of radiology; Radiation exposure

Indexed keywords

CLINICAL PRACTICE; COMPUTER ASSISTED TOMOGRAPHY; HUMAN; IONIZING RADIATION; PATIENT CARE; PRACTICE GUIDELINE; RADIATION DOSE; RADIATION EXPOSURE; RADIOLOGIST; REVIEW;

EID: 84928096038     PISSN: 15461440     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jacr.2003.11.012     Document Type: Article
Times cited : (88)

References (58)
  • 1
    • 0036831529 scopus 로고    scopus 로고
    • AAPM/RSNA physics tutorial for residents: Topics in CT: Radiation dose in CT
    • McNitt-Gray M.F. AAPM/RSNA physics tutorial for residents: topics in CT: radiation dose in CT. Radiographics. 22:2002;1541-1553
    • (2002) Radiographics , vol.22 , pp. 1541-1553
    • McNitt-Gray, M.F.1
  • 2
    • 0036943726 scopus 로고    scopus 로고
    • Strategies of dose reduction
    • Frush D.P. Strategies of dose reduction. Pediatr Radiol. 32:2002;293-297
    • (2002) Pediatr Radiol , vol.32 , pp. 293-297
    • Frush, D.P.1
  • 3
    • 0036938794 scopus 로고    scopus 로고
    • Pediatric CT: Practical approach to diminish radiation dose
    • Frush D.P. Pediatric CT practical approach to diminish radiation dose. Pediatr Radiol. 32:(10):2002;714-717
    • (2002) Pediatr Radiol , vol.32 , Issue.10 , pp. 714-717
    • Frush, D.P.1
  • 5
    • 0031727651 scopus 로고    scopus 로고
    • Multidetector-array CT: Once again, technology creates new opportunities
    • Berland L.L, Smith J.K. Multidetector-array CT once again, technology creates new opportunities. Radiology. 209:1998;327-329
    • (1998) Radiology , vol.209 , pp. 327-329
    • Berland, L.L.1    Smith, J.K.2
  • 7
    • 0042845953 scopus 로고    scopus 로고
    • National conference on dose reduction in computed tomography, emphasis on pediatrics
    • Linton O.W, Mettler F.A. National conference on dose reduction in computed tomography, emphasis on pediatrics. Am J Roentgenol. 181:2003;321-329
    • (2003) Am J Roentgenol , vol.181 , pp. 321-329
    • Linton, O.W.1    Mettler, F.A.2
  • 8
    • 85030810578 scopus 로고    scopus 로고
    • New York: United Nations Scientific Committee on the Effects of Atomic Radiation
    • United Nations Scientific Committee on the Effects of Atomic Radiation. Medical radiation exposures, annex D [Report to the General Assembly]. 2000;United Nations Scientific Committee on the Effects of Atomic Radiation, New York
    • (2000) Medical Radiation Exposures, Annex D [Report to the General Assembly]
  • 9
    • 0042826172 scopus 로고    scopus 로고
    • Accessed: June 27, Available at:
    • U.S. Census Bureau. Home page. 2003;. Accessed: June 27, Available at: http://www.census.gov
    • (2003) Home Page
  • 10
    • 0042826172 scopus 로고    scopus 로고
    • Accessed June 27, Available at:
    • Arlington Medical Resources, Inc. Home page. 2003;. Accessed June 27, Available at: http://www.amr-data.com
    • (2003) Home Page
  • 12
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • Brenner D.J, Elliston C.D, Hall E.J, et al. Estimated risks of radiation-induced fatal cancer from pediatric CT. Am J Roentgenol. 176:2001;289-296
    • (2001) Am J Roentgenol , vol.176 , pp. 289-296
    • Brenner, D.J.1    Elliston, C.D.2    Hall, E.J.3
  • 13
    • 0034944282 scopus 로고    scopus 로고
    • Radiation exposure to patients from CT: Reality, public perception, and policy
    • Nickoloff E.L, Alderson P.O. Radiation exposure to patients from CT reality, public perception, and policy. Am J Roentgenol. 177:2001;285-287
    • (2001) Am J Roentgenol , vol.177 , pp. 285-287
    • Nickoloff, E.L.1    Alderson, P.O.2
  • 15
    • 0034037495 scopus 로고    scopus 로고
    • Effective doses to patients undergoing thoracic computed tomography examinations
    • Huda W, Scalzetti E.M, Roskopf M. Effective doses to patients undergoing thoracic computed tomography examinations. Med Phys. 27:2000;838-844
    • (2000) Med Phys , vol.27 , pp. 838-844
    • Huda, W.1    Scalzetti, E.M.2    Roskopf, M.3
  • 16
    • 0029883007 scopus 로고    scopus 로고
    • Energy imparted and effective doses in computed tomography
    • Atherton J.V, Huda W. Energy imparted and effective doses in computed tomography. Med Phys. 23:1996;735-741
    • (1996) Med Phys , vol.23 , pp. 735-741
    • Atherton, J.V.1    Huda, W.2
  • 17
    • 0033008479 scopus 로고    scopus 로고
    • Radiation effective doses to patients undergoing abdominal CT examinations
    • Ware D.E, Huda W, Mergo P.J, et al. Radiation effective doses to patients undergoing abdominal CT examinations. Radiology. 210:1999;645-650
    • (1999) Radiology , vol.210 , pp. 645-650
    • Ware, D.E.1    Huda, W.2    Mergo, P.J.3
  • 18
    • 0036939376 scopus 로고    scopus 로고
    • Dose reduction for CT pediatric imaging
    • Morgan H.T. Dose reduction for CT pediatric imaging. Pediatr Radiol. 32:2002;724-728
    • (2002) Pediatr Radiol , vol.32 , pp. 724-728
    • Morgan, H.T.1
  • 19
    • 0036122975 scopus 로고    scopus 로고
    • Is it useful to assess annual effective doses that are less than 100 mSv?
    • Strom D.J, Cameron J.R. Is it useful to assess annual effective doses that are less than 100 mSv? Radiat Prot Dosimetry. 98:2002;239-245
    • (2002) Radiat Prot Dosimetry , vol.98 , pp. 239-245
    • Strom, D.J.1    Cameron, J.R.2
  • 20
    • 0042826172 scopus 로고    scopus 로고
    • Accessed July 2, Available at:
    • Radiology Info. Home page. 2003;. Accessed July 2, Available at: http://www.radiologyinfo.org
    • (2003) Home Page
  • 21
    • 8644274378 scopus 로고    scopus 로고
    • Accessed July 2, Available at:
    • U.S. Food and Drug Administration, Center for Devices and Radiological Health. Whole body scanning using computed tomography (CT). 2003;. Accessed July 2, Available at: http://www.fda.gov/cdrh/ct/index.html
    • (2003) Whole Body Scanning Using Computed Tomography (CT)
  • 22
    • 0043033136 scopus 로고    scopus 로고
    • Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE dose)
    • Greess H, Nömayr A, Wolf H, et al. Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE dose). Eur Radiol. 12:2002;1571-1576
    • (2002) Eur Radiol , vol.12 , pp. 1571-1576
    • Greess, H.1    Nömayr, A.2    Wolf, H.3
  • 23
    • 0034055634 scopus 로고    scopus 로고
    • Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: Evaluation of six anatomical regions
    • Greess H, Wolf H, Baum U, et al. Dose reduction in computed tomography by attenuation-based on-line modulation of tube current evaluation of six anatomical regions. Eur Radiol. 10:2000;391-394
    • (2000) Eur Radiol , vol.10 , pp. 391-394
    • Greess, H.1    Wolf, H.2    Baum, U.3
  • 24
    • 0037380211 scopus 로고    scopus 로고
    • Single versus multi-detector row CT: Comparison of radiation doses and dose profile
    • Thornton F.J, Paulson E.K, Yoshizumi T.T, Frush D.P, Nelson R.C. Single versus multi-detector row CT comparison of radiation doses and dose profile. Acad Radiol. 10:2003;379-385
    • (2003) Acad Radiol , vol.10 , pp. 379-385
    • Thornton, F.J.1    Paulson, E.K.2    Yoshizumi, T.T.3    Frush, D.P.4    Nelson, R.C.5
  • 25
    • 0037372750 scopus 로고    scopus 로고
    • Multi-detector row CT: Radiation dose characteristics
    • Hamberg L.M, Rhea J.T, Hunter G.J, Thrall J.H. Multi-detector row CT radiation dose characteristics. Radiology. 226:2003;762-772
    • (2003) Radiology , vol.226 , pp. 762-772
    • Hamberg, L.M.1    Rhea, J.T.2    Hunter, G.J.3    Thrall, J.H.4
  • 28
    • 0033658777 scopus 로고    scopus 로고
    • Data acquisition for pediatric CT angiography: Problems and solutions
    • Cohen R.A, Frush D.P, Donnelly L.F. Data acquisition for pediatric CT angiography problems and solutions. Pediatr Radiol. 30:2000;813-822
    • (2000) Pediatr Radiol , vol.30 , pp. 813-822
    • Cohen, R.A.1    Frush, D.P.2    Donnelly, L.F.3
  • 29
    • 0038245045 scopus 로고    scopus 로고
    • Multiplanar and three-dimensional imaging of the thorax
    • Ravenel J.G, McAdams H.P. Multiplanar and three-dimensional imaging of the thorax. Radiol Clin North Am. 41:2003;475-489
    • (2003) Radiol Clin North Am , vol.41 , pp. 475-489
    • Ravenel, J.G.1    McAdams, H.P.2
  • 31
    • 0032518878 scopus 로고    scopus 로고
    • Effect of computed tomography of the appendix on treatment of patients and use of hospital resources
    • Rao P.M, Rhea J.T, Novelline R.A, Mostafavi A.A, McCabe C.J. Effect of computed tomography of the appendix on treatment of patients and use of hospital resources. N Engl J Med. 338:1998;141-146
    • (1998) N Engl J Med , vol.338 , pp. 141-146
    • Rao, P.M.1    Rhea, J.T.2    Novelline, R.A.3    Mostafavi, A.A.4    McCabe, C.J.5
  • 32
    • 0035840874 scopus 로고    scopus 로고
    • Has misdiagnosis of appendicitis decreased over time? a population-based analysis
    • Flum D.R, Morris A, Koepsell T, Dellinger E.P. Has misdiagnosis of appendicitis decreased over time? A population-based analysis. JAMA. 286:2001;1748-1753
    • (2001) JAMA , vol.286 , pp. 1748-1753
    • Flum, D.R.1    Morris, A.2    Koepsell, T.3    Dellinger, E.P.4
  • 33
  • 34
    • 0036069105 scopus 로고    scopus 로고
    • CT screening: Why do I do it?
    • Brant-Zawadzki M. CT screening why do I do it? Am J Roentgenol. 179:2002;319-326
    • (2002) Am J Roentgenol , vol.179 , pp. 319-326
    • Brant-Zawadzki, M.1
  • 36
    • 84928100304 scopus 로고    scopus 로고
    • Yes, for high dose helical CT. Response
    • In press
    • Hall EJ. Yes, for high dose helical CT. Response. Pediatr Radiol. In press
    • Pediatr Radiol
    • Hall, E.J.1
  • 37
    • 0036838837 scopus 로고    scopus 로고
    • Cancer risk from low level radiation
    • Cohen B.C. Cancer risk from low level radiation. Am J Roentgenol. 179:2002;1137-1143
    • (2002) Am J Roentgenol , vol.179 , pp. 1137-1143
    • Cohen, B.C.1
  • 38
    • 0036943614 scopus 로고    scopus 로고
    • Estimating cancer risks from pediatric CT: Going from the qualitative to the quantitative
    • Brenner D.J. Estimating cancer risks from pediatric CT going from the qualitative to the quantitative. Pediatr Radiol. 32:2002;228-231
    • (2002) Pediatr Radiol , vol.32 , pp. 228-231
    • Brenner, D.J.1
  • 39
    • 0035403775 scopus 로고    scopus 로고
    • Biological responses to low dose of ionizing radiation: Detriment versus hormesis. 1. Dose responses of cells and tissues
    • Feinendegen L.E, Pollycove M. Biological responses to low dose of ionizing radiation detriment versus hormesis. 1. Dose responses of cells and tissues. J Nucl Med. 42:2001;17N-37N
    • (2001) J Nucl Med , vol.42
    • Feinendegen, L.E.1    Pollycove, M.2
  • 40
    • 0035463425 scopus 로고    scopus 로고
    • Biological responses to low dose of ionizing radiation: Detriment versus hormesis. 1. Dose responses to organisms
    • Pollycove M, Feinendegen L.E. Biological responses to low dose of ionizing radiation detriment versus hormesis. 1. Dose responses to organisms. J Nucl Med. 42:2001;26N-37N
    • (2001) J Nucl Med , vol.42
    • Pollycove, M.1    Feinendegen, L.E.2
  • 41
    • 0034920719 scopus 로고    scopus 로고
    • 100 Years of observation on British radiologists: Mortality from cancer and other causes 1897-1997
    • Berrington A, Darby S.C, Weiss H.A, Doll R. 100 years of observation on British radiologists mortality from cancer and other causes 1897-1997. Br J Radiol. 74:2001;507-519
    • (2001) Br J Radiol , vol.74 , pp. 507-519
    • Berrington, A.1    Darby, S.C.2    Weiss, H.A.3    Doll, R.4
  • 42
    • 0036942687 scopus 로고    scopus 로고
    • Lessons we have learned from our children: Cancer risks from diagnostic radiology
    • Hall E.J. Lessons we have learned from our children cancer risks from diagnostic radiology. Pediatr Radiol. 32:2002;700-706
    • (2002) Pediatr Radiol , vol.32 , pp. 700-706
    • Hall, E.J.1
  • 43
    • 0036939214 scopus 로고    scopus 로고
    • Ionizing radiation and cancer risks: Evidence from epidemiology
    • Ron E. Ionizing radiation and cancer risks evidence from epidemiology. Pediatr Radiol. 32:2002;232-237
    • (2002) Pediatr Radiol , vol.32 , pp. 232-237
    • Ron, E.1
  • 44
    • 0033864575 scopus 로고    scopus 로고
    • Radiation-related cancer risks at low doses among atomic bomb survivors
    • Pierce D.A, Preston D.L. Radiation-related cancer risks at low doses among atomic bomb survivors. Radiat Res. 154:2000;178-186
    • (2000) Radiat Res , vol.154 , pp. 178-186
    • Pierce, D.A.1    Preston, D.L.2
  • 45
    • 0029900122 scopus 로고    scopus 로고
    • Studies of the mortality of atomic bomb survivors Report 12, part 1. Cancer. 1950-1990
    • Pierce D.A, Shimizu Y, Preston D.L, et al. Studies of the mortality of atomic bomb survivors Report 12, part 1. Cancer. 1950-1990. Radiat Res. 146:1996;1-27
    • (1996) Radiat Res , vol.146 , pp. 1-27
    • Pierce, D.A.1    Shimizu, Y.2    Preston, D.L.3
  • 47
    • 0035141920 scopus 로고    scopus 로고
    • Helical CT of the body: Are settings adjusted for pediatric patients?
    • Paterson A, Frush D.P, Donnelly L.F. Helical CT of the body are settings adjusted for pediatric patients? Am J Roentgenol. 176:2001;297-301
    • (2001) Am J Roentgenol , vol.176 , pp. 297-301
    • Paterson, A.1    Frush, D.P.2    Donnelly, L.F.3
  • 48
    • 0036939135 scopus 로고    scopus 로고
    • Conference on the ALARA (as low as reasonably achievable) concept in pediatric CT: Intelligent dose reduction
    • Slovis T.L. Conference on the ALARA (as low as reasonably achievable) concept in pediatric CT intelligent dose reduction. Pediatr Radiol. 32:2002;217-218
    • (2002) Pediatr Radiol , vol.32 , pp. 217-218
    • Slovis, T.L.1
  • 49
    • 0037307190 scopus 로고    scopus 로고
    • Potential legal ramifications of whole-body CT screening: Taking a peek into Pandora' s box
    • Berlin L. Potential legal ramifications of whole-body CT screening taking a peek into Pandora' s box. Am J Roentgenol. 180:2003;317-322
    • (2003) Am J Roentgenol , vol.180 , pp. 317-322
    • Berlin, L.1
  • 50
    • 0142088633 scopus 로고    scopus 로고
    • Response. Responsible CT
    • Frush D.P. Response. Responsible CT. Radiology. 229:2003;289-291
    • (2003) Radiology , vol.229 , pp. 289-291
    • Frush, D.P.1
  • 51
    • 85030812196 scopus 로고    scopus 로고
    • Available at: ftp: //ftp.cordis.lu/pub.fp5-euratom/docs/eur1626.pdf. Accessed June 27, 2003
  • 55
    • 0033966290 scopus 로고    scopus 로고
    • Application of European Commission reference levels to a regional CT dose survey
    • Clarke J, Cranley K, Robinson J, Smith P.H, Workman A. Application of European Commission reference levels to a regional CT dose survey. Br J Radiol. 73:2000;43-50
    • (2000) Br J Radiol , vol.73 , pp. 43-50
    • Clarke, J.1    Cranley, K.2    Robinson, J.3    Smith, P.H.4    Workman, A.5
  • 56
    • 0030732612 scopus 로고    scopus 로고
    • CT standard protocols are of limited value in assessing actual patient dose
    • Wade J.P, Weyman J.L, Goldstone K.E. CT standard protocols are of limited value in assessing actual patient dose. Br J Radiol. 70:1997;1146-1151
    • (1997) Br J Radiol , vol.70 , pp. 1146-1151
    • Wade, J.P.1    Weyman, J.L.2    Goldstone, K.E.3
  • 57
    • 0034804973 scopus 로고    scopus 로고
    • Application of European Commission reference dose levels in CT examinations in Crete, Greece
    • Tsapaki V, Kottous S, Papadimitriov D. Application of European Commission reference dose levels in CT examinations in Crete, Greece. Br J Radiol. 74:2001;836-840
    • (2001) Br J Radiol , vol.74 , pp. 836-840
    • Tsapaki, V.1    Kottous, S.2    Papadimitriov, D.3
  • 58
    • 85030809331 scopus 로고    scopus 로고
    • Accessed July 2, Available at:
    • American College of Radiology. ACR accreditation programs. 2003;. Accessed July 2, Available at: http://www.acr.org/dyna/?doc=departments/ stand_accred/accreditation/index.html
    • (2003) ACR Accreditation Programs


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.