Skin penetration and fracture strength testing of silicon dioxide microneedles

Author keywords

Bio MEMS; DRIE; Lab on a chip; Microneedles

Indexed keywords

BIOMEMS; DRIE; FLUID DELIVERY; FRACTURE STRENGTHS; INSERTION FORCE; LAB-ON-A-CHIP; LOAD CELLS; MICRONEEDLES; SHEAR FRACTURE; SKIN PENETRATION;

EID: 80052268207     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2010.09.024     Document Type: Article
Times cited : (17)

References (23)
  • 2
    • 33846492454 scopus 로고    scopus 로고
    • Coated microneedles for transdermal delivery
    • DOI 10.1016/j.jconrel.2006.10.017, PII S0168365906005839
    • H.S. Gill, and M.R. Prausnitz Coated microneedles for transdermal delivery Journal of Controlled Release 117 2 2007 227 237 (Pubitemid 46161873)
    • (2007) Journal of Controlled Release , vol.117 , Issue.2 , pp. 227-237
    • Gill, H.S.1    Prausnitz, M.R.2
  • 5
    • 18144410179 scopus 로고    scopus 로고
    • Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
    • DOI 10.1016/j.jconrel.2005.02.002
    • J.H. Park, M.G. Allen, and M.R. Prausnitz Biodegradable polymer microneedles: fabrication, mechanics and transdermal drug delivery Journal of Controlled Release 104 1 2005 51 66 (Pubitemid 40615235)
    • (2005) Journal of Controlled Release , vol.104 , Issue.1 , pp. 51-66
    • Park, J.-H.1    Allen, M.G.2    Prausnitz, M.R.3
  • 6
    • 0037871729 scopus 로고    scopus 로고
    • Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer
    • P. Griss, and G. Stemme Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer, Journal of Microelectromechanical Systems 12 3 2003 296 301
    • (2003) Journal of Microelectromechanical Systems , vol.12 , Issue.3 , pp. 296-301
    • Griss, P.1    Stemme, G.2
  • 9
    • 18144406839 scopus 로고    scopus 로고
    • Microdialysis microneedles for continuous medical monitoring
    • DOI 10.1007/s10544-005-6173-9
    • J.D. Zahn, D. Trebotich, and D. Liepmann Microdialysis microneedles for continuous medical monitoring Biomedical Microdevices 7 1 2005 59 69 (Pubitemid 40613132)
    • (2005) Biomedical Microdevices , vol.7 , Issue.1 , pp. 59-69
    • Zahn, J.D.1    Trebotich, D.2    Liepmann, D.3
  • 11
  • 12
    • 14744302241 scopus 로고    scopus 로고
    • A unique fabrication approach for microneedles using coherent porous silicon technology
    • DOI 10.1016/j.snb.2004.06.035, PII S0925400504004745
    • S. Rajaraman, and H.T. Henderson A unique fabrication approach for microneedles using coherent porous silicon technology Sensors and Actuators: B Chemical 105 2 2005 443 448 (Pubitemid 40330121)
    • (2005) Sensors and Actuators, B: Chemical , vol.105 , Issue.2 , pp. 443-448
    • Rajaraman, S.1    Henderson, H.T.2
  • 14
    • 2942716734 scopus 로고    scopus 로고
    • Insertion of microneedles into skin: Measurement and prediction of insertion force and needle fracture force
    • DOI 10.1016/j.jbiomech.2003.12.010, PII S0021929003004731
    • S.P. Davis, B.J. Landis, Z.H. Adams, M.G. Allen, and M.R. Prausnitz Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force Journal of Biomechanics 37 8 2004 1155 1163 (Pubitemid 38798369)
    • (2004) Journal of Biomechanics , vol.37 , Issue.8 , pp. 1155-1163
    • Davis, S.P.1    Landis, B.J.2    Adams, Z.H.3    Allen, M.G.4    Prausnitz, M.R.5
  • 15
    • 0031059931 scopus 로고    scopus 로고
    • Ranking the fracture toughness of thin mammalian soft tissues using the scissors cutting test
    • DOI 10.1016/S0021-9290(96)00101-7, PII S0021929096001017
    • B.P. Pereira, P.W. Lucas, and T. SweeHin Ranking the fracture toughness of thin mammalian soft tissues using the scissors cutting test Journal of Biomechanics 30 1 1997 91 94 (Pubitemid 26421560)
    • (1997) Journal of Biomechanics , vol.30 , Issue.1 , pp. 91-94
    • Pereira, B.P.1    Lucas, P.W.2    Swee-Hin, T.3
  • 17
    • 0020935536 scopus 로고
    • Measurement of the fracture-toughness of extensible connective tissues
    • P.P. Purslow Measurement of the fracture-toughness of extensible connective tissues Journal of Materials Science 18 12 1983 3591 3598 (Pubitemid 14504791)
    • (1983) Journal of Materials Science , vol.18 , Issue.12 , pp. 3591-3598
    • Purslow, P.P.1
  • 18
    • 41749123410 scopus 로고    scopus 로고
    • Optimization of square microneedle arrays for increasing drug permeability in skin
    • B. Al-Qallaf, and D.B. Das Optimization of square microneedle arrays for increasing drug permeability in skin Chemical Engineering Science 63 9 2008 2523 2535
    • (2008) Chemical Engineering Science , vol.63 , Issue.9 , pp. 2523-2535
    • Al-Qallaf, B.1    Das, D.B.2
  • 21
    • 77952418937 scopus 로고    scopus 로고
    • Axial and shear fracture strength evaluation of silicon microneedles
    • P. Khanna, K. Luongo, J.A. Strom, and S. Bhansali Axial and shear fracture strength evaluation of silicon microneedles Microsystem Technologies 16 6 2010 973 978
    • (2010) Microsystem Technologies , vol.16 , Issue.6 , pp. 973-978
    • Khanna, P.1    Luongo, K.2    Strom, J.A.3    Bhansali, S.4
  • 23
    • 0008670190 scopus 로고    scopus 로고
    • Microfabricated polysilicon microneedles for minimally invasive biomedical devices
    • J.D Zahn, N.H. Talbot, D. Liepmann, and A.P. Pisano Microfabricated polysilicon microneedles for minimally invasive biomedical devices Biomedical Microdevices 2 4 2000 295 303
    • (2000) Biomedical Microdevices , vol.2 , Issue.4 , pp. 295-303
    • Zahn, J.D.1    Talbot, N.H.2    Liepmann, D.3    Pisano, A.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.