메뉴 건너뛰기




Volumn 16, Issue 6, 2010, Pages 973-978

Axial and shear fracture strength evaluation of silicon microneedles

Author keywords

[No Author keywords available]

Indexed keywords

ANALYTICAL DETERMINATION; AXIAL FORCES; BEAM FRACTURE; BULK MATERIALS; CRITICAL LIMIT; HUMAN CADAVER SKINS; HUMAN SKIN; MICRO-SCALES; MICRONEEDLES; PEAK STRESS; SHEAR FORCE; SHEAR FRACTURE; SHEAR LOADS; SILICON MICRONEEDLES;

EID: 77952418937     PISSN: 09467076     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00542-010-1070-4     Document Type: Article
Times cited : (25)

References (11)
  • 1
    • 0033230574 scopus 로고    scopus 로고
    • Micromachined needle arrays for drug delivery or fluid extraction
    • 10.1109/51.805145
    • J Brazzle I Papautsky, et al. 1999 Micromachined needle arrays for drug delivery or fluid extraction Eng Med Biol Mag IEEE 18 6 53 58 10.1109/51.805145
    • (1999) Eng Med Biol Mag IEEE , vol.18 , Issue.6 , pp. 53-58
    • Brazzle, J.1    Papautsky, I.2
  • 2
    • 0034320862 scopus 로고    scopus 로고
    • Investigating the influence of fabrication process and crystal orientation on shear strength of silicon microcomponents
    • 10.1023/A:1004873029495
    • Q Chen D Yao, et al. 2000 Investigating the influence of fabrication process and crystal orientation on shear strength of silicon microcomponents J Mater Sci 35 21 5465 5474 10.1023/A:1004873029495
    • (2000) J Mater Sci , vol.35 , Issue.21 , pp. 5465-5474
    • Chen, Q.1    Yao, D.2
  • 3
    • 2942716734 scopus 로고    scopus 로고
    • Insertion of microneedles into skin: Measurement and prediction of insertion force and needle fracture force
    • DOI 10.1016/j.jbiomech.2003.12.010, PII S0021929003004731
    • SP Davis BJ Landis, et al. 2004 Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force J Biomech 37 8 1155 1163 10.1016/j.jbiomech.2003.12.010 (Pubitemid 38798369)
    • (2004) Journal of Biomechanics , vol.37 , Issue.8 , pp. 1155-1163
    • Davis, S.P.1    Landis, B.J.2    Adams, Z.H.3    Allen, M.G.4    Prausnitz, M.R.5
  • 4
    • 0742301752 scopus 로고    scopus 로고
    • Silicon micromachined hollow microneedles for transdermal liquid transport
    • 10.1109/JMEMS.2003.820293
    • H Gardeniers R Luttge, et al. 2003 Silicon micromachined hollow microneedles for transdermal liquid transport J Microelectromech Syst 12 6 855 862 10.1109/JMEMS.2003.820293
    • (2003) J Microelectromech Syst , vol.12 , Issue.6 , pp. 855-862
    • Gardeniers, H.1    Luttge, R.2
  • 5
    • 33846492454 scopus 로고    scopus 로고
    • Coated microneedles for transdermal delivery
    • DOI 10.1016/j.jconrel.2006.10.017, PII S0168365906005839
    • H Gill M Prausnitz 2007 Coated microneedles for transdermal delivery J Control Release 117 2 227 237 10.1016/j.jconrel.2006.10.017 (Pubitemid 46161873)
    • (2007) Journal of Controlled Release , vol.117 , Issue.2 , pp. 227-237
    • Gill, H.S.1    Prausnitz, M.R.2
  • 6
    • 0037871729 scopus 로고    scopus 로고
    • Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer
    • 10.1109/JMEMS.2003.809959
    • P Griss G Stemme 2003 Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer J Microelectromech Syst 12 3 296 301 10.1109/JMEMS.2003.809959
    • (2003) J Microelectromech Syst , vol.12 , Issue.3 , pp. 296-301
    • Griss, P.1    Stemme, G.2
  • 8
    • 0034578084 scopus 로고    scopus 로고
    • Microfabricated microneedles for gene and drug delivery
    • 10.1146/annurev.bioeng.2.1.289
    • D McAllister M Allen, et al. 2000 Microfabricated microneedles for gene and drug delivery Annu Rev Biomed Eng 2 1 289 313 10.1146/annurev.bioeng.2.1.289
    • (2000) Annu Rev Biomed Eng , vol.2 , Issue.1 , pp. 289-313
    • McAllister, D.1    Allen, M.2
  • 10
    • 18144410179 scopus 로고    scopus 로고
    • Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
    • DOI 10.1016/j.jconrel.2005.02.002
    • J Park M Allen, et al. 2005 Biodegradable polymer microneedles: fabrication, mechanics and transdermal drug delivery J Control Release 104 1 51 66 10.1016/j.jconrel.2005.02.002 (Pubitemid 40615235)
    • (2005) Journal of Controlled Release , vol.104 , Issue.1 , pp. 51-66
    • Park, J.-H.1    Allen, M.G.2    Prausnitz, M.R.3
  • 11
    • 18144406839 scopus 로고    scopus 로고
    • Microdialysis microneedles for continuous medical monitoring
    • DOI 10.1007/s10544-005-6173-9
    • J Zahn D Trebotich, et al. 2005 Microdialysis microneedles for continuous medical monitoring Biomed Microdevices 7 1 59 69 10.1007/s10544-005-6173-9 (Pubitemid 40613132)
    • (2005) Biomedical Microdevices , vol.7 , Issue.1 , pp. 59-69
    • Zahn, J.D.1    Trebotich, D.2    Liepmann, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.