메뉴 건너뛰기




Volumn 40, Issue 3, 2011, Pages 736-742

In vitro assessment of heart valve bioprostheses by cardiovascular magnetic resonance: Four-dimensional mapping of flow patterns and orifice area planimetry

Author keywords

Blood flow velocity; Heart valve prosthesis; Heart valves; Hemodynamics; Magnetic resonance imaging

Indexed keywords

GLYCEROL; WATER;

EID: 80051575159     PISSN: 10107940     EISSN: 1873734X     Source Type: Journal    
DOI: 10.1016/j.ejcts.2010.12.040     Document Type: Article
Times cited : (19)

References (25)
  • 1
    • 77952589432 scopus 로고    scopus 로고
    • Choice of prosthetic heart valve in adults. An update
    • Rahimtoola S.H. Choice of prosthetic heart valve in adults. An update. J Am Coll Cardiol 2010, 55:2413-2426.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 2413-2426
    • Rahimtoola, S.H.1
  • 4
    • 48649091104 scopus 로고    scopus 로고
    • Time-resolved magnetic resonance angiography and flow-sensitive 4-dimensional magnetic resonance imaging at 3 Tesla for blood flow and wall shear stress analysis
    • Frydrychowicz A., Berger A., Russe M.F., Stalder A.F., Harloff A., Dittrich S., Hennig J., Langer M., Markl M. Time-resolved magnetic resonance angiography and flow-sensitive 4-dimensional magnetic resonance imaging at 3 Tesla for blood flow and wall shear stress analysis. J Thorac Cardiovasc Surg 2008, 136:400-407.
    • (2008) J Thorac Cardiovasc Surg , vol.136 , pp. 400-407
    • Frydrychowicz, A.1    Berger, A.2    Russe, M.F.3    Stalder, A.F.4    Harloff, A.5    Dittrich, S.6    Hennig, J.7    Langer, M.8    Markl, M.9
  • 5
    • 78751580683 scopus 로고    scopus 로고
    • Time-resolved three-dimensional magnetic resonance velocity mapping of cardiovascular flow paths in volunteers and patients with Fontan circulation
    • Markl M., Geiger J., Kilner P.J., Foll D., Stiller B., Beyersdorf F., Arnold R., Frydrychowicz A. Time-resolved three-dimensional magnetic resonance velocity mapping of cardiovascular flow paths in volunteers and patients with Fontan circulation. Eur J Cardiothorac Surg 2011, 39:206-212.
    • (2011) Eur J Cardiothorac Surg , vol.39 , pp. 206-212
    • Markl, M.1    Geiger, J.2    Kilner, P.J.3    Foll, D.4    Stiller, B.5    Beyersdorf, F.6    Arnold, R.7    Frydrychowicz, A.8
  • 6
    • 34848831791 scopus 로고    scopus 로고
    • Update of the European standards for inactive surgical implants in the area of heart valve prostheses
    • Eichinger W., Dabritz S., Lange R. Update of the European standards for inactive surgical implants in the area of heart valve prostheses. Eur J Cardiothorac Surg 2007, 32:690-695.
    • (2007) Eur J Cardiothorac Surg , vol.32 , pp. 690-695
    • Eichinger, W.1    Dabritz, S.2    Lange, R.3
  • 8
    • 34249010507 scopus 로고    scopus 로고
    • Carpentier-Edwards Perimount Magna valve versus Medtronic Hancock II: a matched hemodynamic comparison
    • Borger M.A., Nette A.F., Maganti M., Feindel C.M. Carpentier-Edwards Perimount Magna valve versus Medtronic Hancock II: a matched hemodynamic comparison. Ann Thorac Surg 2007, 83:2054-2058.
    • (2007) Ann Thorac Surg , vol.83 , pp. 2054-2058
    • Borger, M.A.1    Nette, A.F.2    Maganti, M.3    Feindel, C.M.4
  • 10
    • 1542619563 scopus 로고    scopus 로고
    • Mid-term hemodynamic and clinical results of the stented porcine medtronic mosaic valve in aortic position
    • Botzenhardt F., Gansera B., Kemkes B.M. Mid-term hemodynamic and clinical results of the stented porcine medtronic mosaic valve in aortic position. Thorac Cardiovasc Surg 2004, 52:34-41.
    • (2004) Thorac Cardiovasc Surg , vol.52 , pp. 34-41
    • Botzenhardt, F.1    Gansera, B.2    Kemkes, B.M.3
  • 11
    • 53349128872 scopus 로고    scopus 로고
    • The changing spectrum of bioprostheses hydrodynamic performance: considerations on in-vitro tests
    • Bottio T., Tarzia V., Rizzoli G., Gerosa G. The changing spectrum of bioprostheses hydrodynamic performance: considerations on in-vitro tests. Interact Cardiovasc Thorac Surg 2008, 7:750-754.
    • (2008) Interact Cardiovasc Thorac Surg , vol.7 , pp. 750-754
    • Bottio, T.1    Tarzia, V.2    Rizzoli, G.3    Gerosa, G.4
  • 12
    • 2642574330 scopus 로고    scopus 로고
    • Hemodynamic and clinical outcomes with the Biocor valve in the aortic position: an 8-year experience
    • Bottio T., Rizzoli G., Thiene G., Nesseris G., Casarotto D., Gerosa G. Hemodynamic and clinical outcomes with the Biocor valve in the aortic position: an 8-year experience. J Thorac Cardiovasc Surg 2004, 127:1616-1623.
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 1616-1623
    • Bottio, T.1    Rizzoli, G.2    Thiene, G.3    Nesseris, G.4    Casarotto, D.5    Gerosa, G.6
  • 13
    • 0036658324 scopus 로고    scopus 로고
    • Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis
    • Dellgren G., David T.E., Raanani E., Armstrong S., Ivanov J., Rakowski H. Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis. J Thorac Cardiovasc Surg 2002, 124:146-154.
    • (2002) J Thorac Cardiovasc Surg , vol.124 , pp. 146-154
    • Dellgren, G.1    David, T.E.2    Raanani, E.3    Armstrong, S.4    Ivanov, J.5    Rakowski, H.6
  • 17
    • 69549087044 scopus 로고    scopus 로고
    • Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report From the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Asso
    • Zoghbi W.A., Chambers J.B., Dumesnil J.G., Foster E., Gottdiener J.S., Grayburn P.A., Khandheria B.K., Levine R.A., Marx G.R., Miller F.A., Nakatani S., Quinones M.A., Rakowski H., Rodriguez L.L., Swaminathan M., Waggoner A.D., Weissman N.J., Zabalgoitia M. Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report From the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography. J Am Soc Echocardiogr 2009, 22:975-1014.
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 975-1014
    • Zoghbi, W.A.1    Chambers, J.B.2    Dumesnil, J.G.3    Foster, E.4    Gottdiener, J.S.5    Grayburn, P.A.6    Khandheria, B.K.7    Levine, R.A.8    Marx, G.R.9    Miller, F.A.10    Nakatani, S.11    Quinones, M.A.12    Rakowski, H.13    Rodriguez, L.L.14    Swaminathan, M.15    Waggoner, A.D.16    Weissman, N.J.17    Zabalgoitia, M.18
  • 18
    • 0242524394 scopus 로고    scopus 로고
    • Normal values for Doppler echocardiographic assessment of heart valve prostheses
    • Rosenhek R., Binder T., Maurer G., Baumgartner H. Normal values for Doppler echocardiographic assessment of heart valve prostheses. J Am Soc Echocardiogr 2003, 16:1116-1127.
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 1116-1127
    • Rosenhek, R.1    Binder, T.2    Maurer, G.3    Baumgartner, H.4
  • 19
    • 58249086539 scopus 로고    scopus 로고
    • Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database
    • Brown J.M., O'Brien S.M., Wu C., Sikora J.A., Griffith B.P., Gammie J.S. Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database. J Thorac Cardiovasc Surg 2009, 137:82-90.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 82-90
    • Brown, J.M.1    O'Brien, S.M.2    Wu, C.3    Sikora, J.A.4    Griffith, B.P.5    Gammie, J.S.6
  • 20
    • 33646168073 scopus 로고    scopus 로고
    • Small aortic annulus: the hydrodynamic performances of 5 commercially available tissue valves
    • Gerosa G., Tarzia V., Rizzoli G., Bottio T. Small aortic annulus: the hydrodynamic performances of 5 commercially available tissue valves. J Thorac Cardiovasc Surg 2006, 131:1058-1064.
    • (2006) J Thorac Cardiovasc Surg , vol.131 , pp. 1058-1064
    • Gerosa, G.1    Tarzia, V.2    Rizzoli, G.3    Bottio, T.4
  • 22
    • 0034961928 scopus 로고    scopus 로고
    • Magnetic resonance planimetry of the vena contracta as a new approach to assessment of stenotic heart valves: an in vitro study
    • Strohm O., Schulz-Menger J., Hanlein D., Dietz R., Friedrich M.G. Magnetic resonance planimetry of the vena contracta as a new approach to assessment of stenotic heart valves: an in vitro study. J Magn Reson Imaging 2001, 14:31-34.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 31-34
    • Strohm, O.1    Schulz-Menger, J.2    Hanlein, D.3    Dietz, R.4    Friedrich, M.G.5
  • 23
    • 34247868104 scopus 로고    scopus 로고
    • Quantification of aortic valve stenosis in MRI-comparison of steady-state free precession and fast low-angle shot sequences
    • Schlosser T., Malyar N., Jochims M., Breuckmann F., Hunold P., Bruder O., Erbel R., Barkhausen J. Quantification of aortic valve stenosis in MRI-comparison of steady-state free precession and fast low-angle shot sequences. Eur Radiol 2007, 17:1284-1290.
    • (2007) Eur Radiol , vol.17 , pp. 1284-1290
    • Schlosser, T.1    Malyar, N.2    Jochims, M.3    Breuckmann, F.4    Hunold, P.5    Bruder, O.6    Erbel, R.7    Barkhausen, J.8
  • 24
    • 77951610240 scopus 로고    scopus 로고
    • In vitro assessment of flow patterns and turbulence intensity in prosthetic heart valves using generalized phase-contrast MRI
    • Kvitting J.P., Dyverfeldt P., Sigfridsson A., Franzen S., Wigstrom L., Bolger A.F., Ebbers T. In vitro assessment of flow patterns and turbulence intensity in prosthetic heart valves using generalized phase-contrast MRI. J Magn Reson Imaging 2010, 31:1075-1080.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 1075-1080
    • Kvitting, J.P.1    Dyverfeldt, P.2    Sigfridsson, A.3    Franzen, S.4    Wigstrom, L.5    Bolger, A.F.6    Ebbers, T.7
  • 25
    • 51449112368 scopus 로고    scopus 로고
    • Assessment of fluctuating velocities in disturbed cardiovascular blood flow: in vivo feasibility of generalized phase-contrast MRI
    • Dyverfeldt P., Kvitting J.P., Sigfridsson A., Engvall J., Bolger A.F., Ebbers T. Assessment of fluctuating velocities in disturbed cardiovascular blood flow: in vivo feasibility of generalized phase-contrast MRI. J Magn Reson Imaging 2008, 28:655-663.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 655-663
    • Dyverfeldt, P.1    Kvitting, J.P.2    Sigfridsson, A.3    Engvall, J.4    Bolger, A.F.5    Ebbers, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.