-
1
-
-
0036210742
-
Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys
-
DOI 10.1016/S0142-9612(01)00328-3, PII S0142961201003283
-
Schiff N, Grosgogeat B, Lissac M, Dalard F,. Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys. Biomaterials 2002; 23: 1995-2002. (Pubitemid 34251073)
-
(2002)
Biomaterials
, vol.23
, Issue.9
, pp. 1995-2002
-
-
Schiff, N.1
Grosgogeat, B.2
Lissac, M.3
Dalard, F.4
-
2
-
-
11144305402
-
Evaluation of the effect of fluoride-containing acetic acid on NiTi wires
-
Kwon YH, Cho HS, Noh DJ, Kim HI, Kim KH,. Evaluation of the effect of fluoride-containing acetic acid on NiTi wires. J Biomed Mater Res B 2005; 72B: 102-108.
-
(2005)
J Biomed Mater Res B
, vol.72 B
, pp. 102-108
-
-
Kwon, Y.H.1
Cho, H.S.2
Noh, D.J.3
Kim, H.I.4
Kim, K.H.5
-
3
-
-
33644811285
-
Electrochemical release testing of nickel-titanium orthodontic wires in artificial saliva using thin layer activation
-
DOI 10.1016/j.actbio.2005.07.008, PII S1742706105001170
-
Cioffi M, Gilliland D, Ceccone G, Chiesa R, Cigada A,. Electrochemical release testing of nickel-titanium orthodontic wires in artificial saliva using thin layer activation. Acta Biomater 2005; 1: 717-724. (Pubitemid 43348763)
-
(2005)
Acta Biomaterialia
, vol.1
, Issue.6
, pp. 717-724
-
-
Cioffi, M.1
Gilliland, D.2
Ceccone, G.3
Chiesa, R.4
Cigada, A.5
-
4
-
-
33749180774
-
Effect of pH and temperature on orthodontic NiTi wires immersed in acidic fluoride solution
-
Ahn HS, Kim MJ, Seol HJ, Lee JH, Kim HI, Kim YH,. Effect of pH and temperature on orthodontic NiTi wires immersed in acidic fluoride solution. J Biomed Mater Res B 2006; 79B: 7-15.
-
(2006)
J Biomed Mater Res B
, vol.79 B
, pp. 7-15
-
-
Ahn, H.S.1
Kim, M.J.2
Seol, H.J.3
Lee, J.H.4
Kim, H.I.5
Kim, Y.H.6
-
5
-
-
33845303006
-
Variation in surface topography of different NiTi orthodontic archwires in various commercial fluoride-containing environments
-
Huang HH,. Variation in surface topography of different NiTi orthodontic archwires in various commercial fluoride-containing environments. Dent Mater 2007; 23: 24-33.
-
(2007)
Dent Mater
, vol.23
, pp. 24-33
-
-
Huang, H.H.1
-
6
-
-
34547651265
-
Influence of fluoride and chloride on corrosion behavior of NiTi orthodontic wires
-
DOI 10.1016/j.actbio.2007.02.002, PII S174270610700027X
-
Li X, Wang J, Han E, Ke W,. Influence of fluoride and chloride on corrosion behavior of NiTi orthodontic wires. Acta Biomater 2007; 3: 807-815. (Pubitemid 47209504)
-
(2007)
Acta Biomaterialia
, vol.3
, Issue.5
, pp. 807-815
-
-
Li, X.1
Wang, J.2
Han, E.-h.3
Ke, W.4
-
7
-
-
0141799744
-
Hydrogen embrittlement of Ni-Ti superelastic alloy in fluoride solution
-
Yokoyama K, Kaneko K, Moriyama K, Asaoka K, Sakai J, Nagumo M,. Hydrogen embrittlement of Ni-Ti superelastic alloy in fluoride solution. J Biomed Mater Res A 2003; 65A: 182-187. (Pubitemid 37521423)
-
(2003)
Journal of Biomedical Materials Research - Part A
, vol.65
, Issue.2
, pp. 182-187
-
-
Yokoyama, K.1
Kaneko, K.2
Moriyama, K.3
Asaoka, K.4
Sakai, J.5
Nagumo, M.6
-
8
-
-
1642408779
-
Delayed fracture of Ni-Ti superelastic alloys in acidic and neutral fluoride solutions
-
Yokoyama K, Kaneko K, Moriyama K, Asaoka K, Sakai J, Nagumo M,. Delayed fracture of Ni-Ti superelastic alloys in acidic and neutral fluoride solutions. J Biomed Mater Res A 2004; 69A: 105-113. (Pubitemid 38364966)
-
(2004)
Journal of Biomedical Materials Research - Part A
, vol.69
, Issue.1
, pp. 105-113
-
-
Yokoyama, K.1
Kaneko, K.2
Moriyama, K.3
Asaoka, K.4
Sakai, J.5
Nagumo, M.6
-
9
-
-
2942659317
-
Hydrogen embrittlement of work-hardened Ni-Ti alloy in fluoride solutions
-
DOI 10.1016/j.biomaterials.2004.02.009, PII S0142961204001474
-
Yokoyama K, Kaneko K, Ogawa T, Moriyama K, Asaoka K, Sakai J,. Hydrogen embrittlement of work-hardened Ni-Ti alloy in fluoride solutions. Biomaterials 2005; 26: 101-108. (Pubitemid 38765158)
-
(2005)
Biomaterials
, vol.26
, Issue.1
, pp. 101-108
-
-
Yokoyama, K.1
Kaneko, K.2
Ogawa, T.3
Moriyama, K.4
Asaoka, K.5
Sakai, J.6
-
10
-
-
33745684739
-
Hydrogen absorption of titanium and nickel-titanium alloys during long-term immersion in neutral fluoride solution
-
Yokoyama K, Ogawa T, Asaoka K, Sakai J,. Hydrogen absorption of titanium and nickel-titanium alloys during long-term immersion in neutral fluoride solution. J Biomed Mater Res B 2006; 78: 204-210.
-
(2006)
J Biomed Mater Res B
, vol.78
, pp. 204-210
-
-
Yokoyama, K.1
Ogawa, T.2
Asaoka, K.3
Sakai, J.4
-
11
-
-
0026899065
-
History, safety, and effectiveness of current bleaching techniques and applications of the nightguard vital bleaching technique
-
Haywood VB,. History, safety, and effectiveness of current bleaching techniques and applications of the nightguard vital bleaching technique. Quintessence Int 1992; 23: 471-488.
-
(1992)
Quintessence Int
, vol.23
, pp. 471-488
-
-
Haywood, V.B.1
-
12
-
-
49349096760
-
An overview of tooth-bleaching techniques: Chemistry, safety and efficacy
-
Sulieman MAM,. An overview of tooth-bleaching techniques: Chemistry, safety and efficacy. Periodontology 2000 2008; 48: 148-169.
-
(2008)
Periodontology 2000
, vol.48
, pp. 148-169
-
-
Sulieman, M.A.M.1
-
13
-
-
0030250798
-
Biological properties of peroxide-containing tooth whiteners
-
DOI 10.1016/S0278-6915(96)00044-0, PII S0278691596000440
-
Li Y,. Biological properties of peroxide-containing tooth whiteners. Food Chem Toxicol 1996; 34: 887-904. (Pubitemid 26419520)
-
(1996)
Food and Chemical Toxicology
, vol.34
, Issue.9
, pp. 887-904
-
-
Li, Y.1
-
14
-
-
0030113061
-
Surface morphology changes in human enamel, dentin and cementum following bleaching: A scanning electron microscopy study
-
Zalkind M, Arwaz JR, Goldman A, Rotstein I,. Surface morphology changes in human enamel, dentin and cementum following bleaching: A scanning electron microscopy study. Endod Dent Traumatol 1996; 12: 82-88. (Pubitemid 126797143)
-
(1996)
Endodontics and Dental Traumatology
, vol.12
, Issue.2
, pp. 82-88
-
-
Zalkind, M.1
Arwaz, J.R.2
Goldman, A.3
Rotstein, I.4
-
15
-
-
4143061454
-
A safety study in vitro for the effects of an in-office bleaching system on the integrity of enamel and dentine
-
DOI 10.1016/j.jdent.2004.06.003, PII S0300571204001034
-
Sulieman M, Addy M, Macdonald E, Rees JS,. A safety study in vitro for the effects of an in-office bleaching system on the integrity of enamel and dentine. J Dent 2004; 32: 581-590. (Pubitemid 39089090)
-
(2004)
Journal of Dentistry
, vol.32
, Issue.7
, pp. 581-590
-
-
Sulieman, M.1
Addy, M.2
Macdonald, E.3
Rees, J.S.4
-
16
-
-
33746298442
-
The bleaching of teeth: A review of the literature
-
DOI 10.1016/j.jdent.2006.02.002, PII S0300571206000492
-
Joiner A,. The bleaching of teeth: A review of the literature. J Dent 2006; 34: 412-419. (Pubitemid 44107626)
-
(2006)
Journal of Dentistry
, vol.34
, Issue.7
, pp. 412-419
-
-
Joiner, A.1
-
17
-
-
33644699749
-
Mineral loss from bovine enamel by a 30% hydrogen peroxide solution
-
DOI 10.1111/j.1365-2842.2004.01360.x
-
Lee KH, Kim HI, Kim KH, Kwon YH,. Mineral loss from bovine enamel by a 30% hydrogen peroxide solution. J Oral Rehabil 2006; 33: 229-233. (Pubitemid 43332416)
-
(2006)
Journal of Oral Rehabilitation
, vol.33
, Issue.3
, pp. 229-233
-
-
Lee, K.H.1
Kim, H.I.2
Kim, K.H.3
Kwon, Y.H.4
-
18
-
-
0037454510
-
Susceptibility to delayed fracture of Ni-Ti superelastic alloy
-
DOI 10.1016/S0921-5093(02)00201-0, PII S0921509302002010
-
Yokoyama K, Watabe S, Hamada K, Sakai J, Asaoka K, Nagumo M,. Susceptibility to delayed fracture of Ni-Ti superelastic alloy. Mater Sci Eng A 2003; 341: 91-97. (Pubitemid 35420111)
-
(2003)
Materials Science and Engineering A
, vol.341
, Issue.1-2
, pp. 91-97
-
-
Yokoyama, K.1
Watabe, S.2
Hamada, K.3
Sakai, J.4
Asaoka, K.5
Nagumo, M.6
-
19
-
-
34249991972
-
Hydrogen absorption and thermal desorption behaviors of Ni-Ti superelastic alloy subjected to sustained tensile-straining test with hydrogen charging
-
DOI 10.1016/j.scriptamat.2007.05.002, PII S135964620700351X
-
Yokoyama K, Tomita M, Asaoka K, Sakai J,. Hydrogen absorption and thermal desorption behaviors of Ni-Ti superelastic alloy subjected to sustained tensile-straining test with hydrogen charging. Scripta Materialia 2007; 57: 393-396. (Pubitemid 46891872)
-
(2007)
Scripta Materialia
, vol.57
, Issue.5
, pp. 393-396
-
-
Yokoyama, K.1
Tomita, M.2
Asaoka, K.3
Sakai, J.4
-
20
-
-
60849128795
-
Hydrogen embrittlement behavior induced by dynamic martensite transformation of Ni-Ti superelastic alloy
-
Yokoyama K, Tomita M, Sakai J,. Hydrogen embrittlement behavior induced by dynamic martensite transformation of Ni-Ti superelastic alloy. Acta Mater 2009; 57: 1875-1885.
-
(2009)
Acta Mater
, vol.57
, pp. 1875-1885
-
-
Yokoyama, K.1
Tomita, M.2
Sakai, J.3
-
21
-
-
0141907230
-
Degradation of tensile strength of Ni-Ti superelastic alloy due to hydrogen absorption in methanol solution containing hydrochloric acid
-
DOI 10.1016/S0921-5093(03)00403-9
-
Yokoyama K, Ogawa T, Asaoka K, Sakai J, Nagumo M,. Degradation of tensile strength of Ni-Ti superelastic alloy due to hydrogen absorption in methanol solution containing hydrochloric acid. Mater Sci Eng A 2003; 360: 153-159. (Pubitemid 37232000)
-
(2003)
Materials Science and Engineering A
, vol.360
, Issue.1-2
, pp. 153-159
-
-
Yokoyama, K.1
Ogawa, T.2
Asaoka, K.3
Sakai, J.4
Nagumo, M.5
-
22
-
-
13344261940
-
Hydrogen embrittlement of Ni-Ti superelastic alloy in ethanol solution containing hydrochloric acid
-
DOI 10.1016/j.msea.2004.10.020, PII S0921509304012717
-
Ogawa T, Yokoyama K, Asaoka K, Sakai J,. Hydrogen embrittlement of Ni-Ti superelastic alloy in ethanol solution containing hydrochloric acid. Mater Sci Eng A 2005; 393: 239-246. (Pubitemid 40198612)
-
(2005)
Materials Science and Engineering A
, vol.393
, Issue.1-2
, pp. 239-246
-
-
Ogawa, T.1
Yokoyama, K.2
Asaoka, K.3
Sakai, J.4
-
23
-
-
84956040351
-
Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants
-
Shabalovskaya SA, Anderegg JW,. Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants. J Vac Sci Technol A 1995; 13: 2624-2632.
-
(1995)
J Vac Sci Technol A
, vol.13
, pp. 2624-2632
-
-
Shabalovskaya, S.A.1
Anderegg, J.W.2
-
24
-
-
0035875976
-
Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials
-
DOI 10.1016/S0142-9612(00)00309-4, PII S0142961200003094
-
Aziz-Kerrzo M, Conroy KG, Fenelon AM, Farrell ST, Breslin CB,. Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials. Biomaterials 2001; 22: 1531-1539. (Pubitemid 32551902)
-
(2001)
Biomaterials
, vol.22
, Issue.12
, pp. 1531-1539
-
-
Aziz-Kerrzo, M.1
Conroy, K.G.2
Fenelon, A.M.3
Farrell, S.T.4
Breslin, C.B.5
-
25
-
-
33644845524
-
Fabrication and characteristics of bioactive sodium titanate/titania graded film on NiTi shape memory alloy
-
DOI 10.1002/jbm.a.30465
-
Chu CL, Chung CY, Zhou J, Pu YP, Lin PH,. Fabrication and characteristics of bioactive sodium titanate/titania graded film on NiTi shape memory alloy. J Biomed Mater Res A 2005; 75: 595-602. (Pubitemid 47233443)
-
(2005)
Journal of Biomedical Materials Research - Part A
, vol.75
, Issue.3
, pp. 595-602
-
-
Chu, C.L.1
Chung, C.Y.2
Zhou, J.3
Pu, Y.P.4
Lin, P.H.5
-
26
-
-
30944434044
-
Surface oxidation of NiTi shape memory alloy in a boiling aqueous solution containing hydrogen peroxide
-
DOI 10.1016/j.msea.2005.11.010, PII S0921509305014164
-
Chu CL, Chung CY, Chu PK,. Surface oxidation of NiTi shape memory alloy in a boiling aqueous solution containing hydrogen peroxide. Mater Sci Eng A 2006; 417: 104-109. (Pubitemid 43116298)
-
(2006)
Materials Science and Engineering A
, vol.417
, Issue.1-2
, pp. 104-109
-
-
Chu, C.L.1
Chung, C.Y.2
Chu, P.K.3
-
27
-
-
34547891045
-
Fracture of Ni-Ti superelastic alloy under sustained tensile load in physiological saline solution containing hydrogen peroxide
-
DOI 10.1002/jbm.a.31173
-
Yokoyama K, Ogawa T, Fujita A, Asaoka K, Sakai J,. Fracture of Ni-Ti superelastic alloy under sustained tensile load in physiological saline solution containing hydrogen peroxide. J Biomed Mater Res A 2007; 82: 558-567. (Pubitemid 47258570)
-
(2007)
Journal of Biomedical Materials Research - Part A
, vol.82
, Issue.3
, pp. 558-567
-
-
Yokoyama, K.1
Ogawa, T.2
Fujita, A.3
Asaoka, K.4
Sakai, J.5
-
28
-
-
0346965750
-
Fracture associated with hydrogen absorption of sustained tensile-loaded titanium in acid and neutral fluoride solutions
-
Yokoyama K, Kaneko K, Miyamoto Y, Asaoka K, Sakai J, Nagumo M,. Fracture associated with hydrogen absorption of sustained tensile-loaded titanium in acid and neutral fluoride solutions. J Biomed Mater Res A 2004; 68: 150-158. (Pubitemid 38030195)
-
(2004)
Journal of Biomedical Materials Research - Part A
, vol.68
, Issue.1
, pp. 150-158
-
-
Yokoyama, K.1
Kaneko, K.2
Miyamoto, Y.3
Asaoka, K.4
Sakai, J.5
Nagumo, M.6
-
29
-
-
0037400539
-
Delayed fracture of beta titanium orthodontic wire in fluoride aqueous solutions
-
DOI 10.1016/S0142-9612(02)00642-7
-
Kaneko K, Yokoyama K, Moriyama K, Asaoka K, Sakai J, Nagumo M,. Delayed fracture of beta titanium orthodontic wire in fluoride aqueous solutions. Biomaterials 2003; 24: 2113-2120. (Pubitemid 36298783)
-
(2003)
Biomaterials
, vol.24
, Issue.12
, pp. 2113-2120
-
-
Kaneko, K.1
Yokoyama, K.2
Moriyama, K.3
Asaoka, K.4
Sakai, J.5
Nagumo, M.6
-
30
-
-
14844284654
-
Susceptibility to delayed fracture of alpha-beta titanium alloy in fluoride solutions
-
DOI 10.1016/j.corsci.2004.08.007, PII S0010938X04002835
-
Yokoyama K, Ogawa T, Asaoka K, Sakai J,. Susceptibility to delayed fracture of alpha-beta titanium alloy in fluoride solutions. Corros Sci 2005; 47: 1778-1793. (Pubitemid 40350689)
-
(2005)
Corrosion Science
, vol.47
, Issue.7
, pp. 1778-1793
-
-
Yokoyama, K.1
Ogawa, T.2
Asaoka, K.3
Sakai, J.4
|