메뉴 건너뛰기




Volumn 82, Issue 3, 2007, Pages 558-567

Fracture of Ni-Ti superelastic alloy under sustained tensile load in physiological saline solution containing hydrogen peroxide

Author keywords

Corrosion; Fracture; Hydrogen peroxide; Ni Ti

Indexed keywords

CORROSION; FRACTURE MECHANICS; HYDROGEN PEROXIDE; MARTENSITIC TRANSFORMATIONS; METAL IONS; SODIUM CHLORIDE;

EID: 34547891045     PISSN: 15493296     EISSN: 15524965     Source Type: Journal    
DOI: 10.1002/jbm.a.31173     Document Type: Article
Times cited : (18)

References (49)
  • 1
    • 0019031792 scopus 로고
    • Some applications of shape-memory alloys
    • Wayman CM. Some applications of shape-memory alloys. J Met 1980;32:129-137.
    • (1980) J Met , vol.32 , pp. 129-137
    • Wayman, C.M.1
  • 2
    • 0030340747 scopus 로고    scopus 로고
    • On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys
    • Shabalovskaya SA. On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys. Biomed Mater Eng 1996;6:267-289.
    • (1996) Biomed Mater Eng , vol.6 , pp. 267-289
    • Shabalovskaya, S.A.1
  • 4
    • 3042703017 scopus 로고    scopus 로고
    • Medical shape memory alloy applications - The market and its products
    • Morgan NB. Medical shape memory alloy applications - The market and its products. Mater Sci Eng A 2004;378:16-23.
    • (2004) Mater Sci Eng A , vol.378 , pp. 16-23
    • Morgan, N.B.1
  • 5
    • 0024862881 scopus 로고
    • Development of shape memory alloys
    • Miyazaki S, Otsuka K. Development of shape memory alloys. ISIJ Int 1989;29:353-377.
    • (1989) ISIJ Int , vol.29 , pp. 353-377
    • Miyazaki, S.1    Otsuka, K.2
  • 6
    • 0030272059 scopus 로고    scopus 로고
    • Corrosion resistance tests on NiTi shape memory alloy
    • Rondelli G. Corrosion resistance tests on NiTi shape memory alloy. Biomaterials 1996;17:2003-2008.
    • (1996) Biomaterials , vol.17 , pp. 2003-2008
    • Rondelli, G.1
  • 8
    • 0033119606 scopus 로고    scopus 로고
    • Localized corrosion behaviour in simulated human body fluids of commercial Ni-Ti orthodontic wires
    • Rondelli G, Vicentini B. Localized corrosion behaviour in simulated human body fluids of commercial Ni-Ti orthodontic wires. Biomaterials 1999;20:785-792.
    • (1999) Biomaterials , vol.20 , pp. 785-792
    • Rondelli, G.1    Vicentini, B.2
  • 9
    • 0038384453 scopus 로고    scopus 로고
    • Ion release from NiTi orthodontic wires in artificial saliva with various acidities
    • Huang HH, Chiu YH, Lee TH, Wu SC, Yang HW, Su KH, Hsu CC. Ion release from NiTi orthodontic wires in artificial saliva with various acidities. Biomaterials 2003;24:3585-3592.
    • (2003) Biomaterials , vol.24 , pp. 3585-3592
    • Huang, H.H.1    Chiu, Y.H.2    Lee, T.H.3    Wu, S.C.4    Yang, H.W.5    Su, K.H.6    Hsu, C.C.7
  • 10
    • 0346850951 scopus 로고    scopus 로고
    • Corrosion behavior of nitinol wires in body fluid environments
    • Carroll WM, Kelly MJ. Corrosion behavior of nitinol wires in body fluid environments. J Biomed Mater Res A 2003;67:1123-1130.
    • (2003) J Biomed Mater Res A , vol.67 , pp. 1123-1130
    • Carroll, W.M.1    Kelly, M.J.2
  • 11
    • 33645926671 scopus 로고    scopus 로고
    • Susceptibility of nitinol to localized corrosion
    • Pound BG. Susceptibility of nitinol to localized corrosion. J Biomed Mater Res A 2006;77:185-191.
    • (2006) J Biomed Mater Res A , vol.77 , pp. 185-191
    • Pound, B.G.1
  • 15
    • 0037221706 scopus 로고    scopus 로고
    • Longitudinal stent fracture 11 months after implantation in the left pulmonary artery and successful management by a stentin-stent maneuver
    • Knirsch W, Haas NA, Lewin MAG, Uhlemann F. Longitudinal stent fracture 11 months after implantation in the left pulmonary artery and successful management by a stentin-stent maneuver. Catheter Cardiovasc Interv 2003;58:116-118.
    • (2003) Catheter Cardiovasc Interv , vol.58 , pp. 116-118
    • Knirsch, W.1    Haas, N.A.2    Lewin, M.A.G.3    Uhlemann, F.4
  • 18
    • 0024598059 scopus 로고
    • Interaction between hydrogen peroxide and titanium: A possible role in the biocompatibility of titanium
    • Tengvall P, Elwing H, Sjoqvist L, Lundström I, Bjursten LM. Interaction between hydrogen peroxide and titanium: A possible role in the biocompatibility of titanium. Biomaterials 1989;10:118-120.
    • (1989) Biomaterials , vol.10 , pp. 118-120
    • Tengvall, P.1    Elwing, H.2    Sjoqvist, L.3    Lundström, I.4    Bjursten, L.M.5
  • 19
    • 0024605097 scopus 로고
    • Titanium-hydrogen peroxide interaction: Model studies of the influence of the inflammatory response on titanium implants
    • Tengvall P, Lundström I, Sjöqvist L, Elwing H, Bjursten LM. Titanium-hydrogen peroxide interaction: Model studies of the influence of the inflammatory response on titanium implants. Biomaterials 1989;10:166-175.
    • (1989) Biomaterials , vol.10 , pp. 166-175
    • Tengvall, P.1    Lundström, I.2    Sjöqvist, L.3    Elwing, H.4    Bjursten, L.M.5
  • 20
    • 0028118588 scopus 로고
    • Electrochemical and XPS studies of titanium for biomaterial applications with respect to the effect of hydrogen peroxide
    • Pan J, Thierry D, Leygraf C. Electrochemical and XPS studies of titanium for biomaterial applications with respect to the effect of hydrogen peroxide. J Biomed Mater Res 1994;28:113-122.
    • (1994) J Biomed Mater Res , vol.28 , pp. 113-122
    • Pan, J.1    Thierry, D.2    Leygraf, C.3
  • 21
    • 0000911585 scopus 로고
    • Biological aspects of TiNi alloy surfaces
    • Shabalovskaya SA. Biological aspects of TiNi alloy surfaces. J Phys IV 1995;5:1199-1204.
    • (1995) J Phys IV , vol.5 , pp. 1199-1204
    • Shabalovskaya, S.A.1
  • 22
    • 0035275589 scopus 로고    scopus 로고
    • 2 studied by electrochemical impedance spectroscopy
    • 2 studied by electrochemical impedance spectroscopy. Corros Sci 2001;43:547-559.
    • (2001) Corros Sci , vol.43 , pp. 547-559
    • Fonseca, C.1    Barbosa, M.A.2
  • 23
    • 0346122852 scopus 로고    scopus 로고
    • Effect of hydrogen peroxide on titanium surfaces: In situ imaging and step-polarization impedance spectroscopy of commercially pure titanium and titanium, 6-aluminum, 4-vanadium
    • Bearinger JP, Orme CA, Gilbert JL. Effect of hydrogen peroxide on titanium surfaces: In situ imaging and step-polarization impedance spectroscopy of commercially pure titanium and titanium, 6-aluminum, 4-vanadium. J Biomed Mater Res A 2003;67:702-712.
    • (2003) J Biomed Mater Res A , vol.67 , pp. 702-712
    • Bearinger, J.P.1    Orme, C.A.2    Gilbert, J.L.3
  • 25
    • 1542609611 scopus 로고    scopus 로고
    • Fracture of nickel-titanium superelastic alloy in sodium hypochlorite solution
    • Yokoyama K, Kaneko K, Yabuta E, Asaoka K, Sakai J. Fracture of nickel-titanium superelastic alloy in sodium hypochlorite solution. Mater Sci Eng A 2004;369:43-48.
    • (2004) Mater Sci Eng A , vol.369 , pp. 43-48
    • Yokoyama, K.1    Kaneko, K.2    Yabuta, E.3    Asaoka, K.4    Sakai, J.5
  • 26
    • 34547906025 scopus 로고
    • A technical agreement for the determination of transformation temperature in shape memory alloys by means of DSC
    • Sugimoto K. A technical agreement for the determination of transformation temperature in shape memory alloys by means of DSC. Netsu Sokutei. 1986;13:110-111.
    • (1986) Netsu Sokutei , vol.13 , pp. 110-111
    • Sugimoto, K.1
  • 27
    • 0033990205 scopus 로고    scopus 로고
    • Thierry B, Tabrizian M, Savadogo O, Yahia L'H. Effect of sterilization processes on NiTi alloy: Surface characterization. J Biomed Mater Res 2000;49:88-98.
    • Thierry B, Tabrizian M, Savadogo O, Yahia L'H. Effect of sterilization processes on NiTi alloy: Surface characterization. J Biomed Mater Res 2000;49:88-98.
  • 29
    • 0034142581 scopus 로고    scopus 로고
    • Metal ion release from titanium with active oxygen species generated by rat macrophages in vitro
    • Mu Y, Kobayashi T, Sumita M, Yamamoto A, Hanawa T. Metal ion release from titanium with active oxygen species generated by rat macrophages in vitro. J Biomed Mater Res 2000;49:238-243.
    • (2000) J Biomed Mater Res , vol.49 , pp. 238-243
    • Mu, Y.1    Kobayashi, T.2    Sumita, M.3    Yamamoto, A.4    Hanawa, T.5
  • 30
    • 0030141235 scopus 로고    scopus 로고
    • Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application
    • Pan J, Thierry D, Leygraf C. Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant application. Electrochim Acta 1996;41:1143-1153.
    • (1996) Electrochim Acta , vol.41 , pp. 1143-1153
    • Pan, J.1    Thierry, D.2    Leygraf, C.3
  • 31
    • 0030111413 scopus 로고    scopus 로고
    • Hydrogen peroxide toward enhanced oxide growth on titanium in PBS solution: Blue coloration and clinical relevance
    • Pan J, Thierry D, Leygraf C. Hydrogen peroxide toward enhanced oxide growth on titanium in PBS solution: Blue coloration and clinical relevance. J Biomed Mater Res 1996;30:393-402.
    • (1996) J Biomed Mater Res , vol.30 , pp. 393-402
    • Pan, J.1    Thierry, D.2    Leygraf, C.3
  • 32
    • 1342323412 scopus 로고    scopus 로고
    • In vitro biocorrosion of Ti-6A1-4V implant alloy by a mouse macrophage cell line
    • Lin HY, Bumgardner JD. In vitro biocorrosion of Ti-6A1-4V implant alloy by a mouse macrophage cell line. J Biomed Mater Res A 2004;68:717-724.
    • (2004) J Biomed Mater Res A , vol.68 , pp. 717-724
    • Lin, H.Y.1    Bumgardner, J.D.2
  • 33
    • 1342329713 scopus 로고    scopus 로고
    • Changes in surface composition of the Ti-6A1-4V implant alloy by cultured macrophage cells
    • Lin HY, Bumgardner JD. Changes in surface composition of the Ti-6A1-4V implant alloy by cultured macrophage cells. App Surf Sci 2004;225:21-28.
    • (2004) App Surf Sci , vol.225 , pp. 21-28
    • Lin, H.Y.1    Bumgardner, J.D.2
  • 35
    • 0034038826 scopus 로고    scopus 로고
    • Evaluation by electrochemical tests of the passive film stability of equiatomic Ni-Ti alloy also in presence of stress-induced martensite
    • Rondelli G, Vicentini B. Evaluation by electrochemical tests of the passive film stability of equiatomic Ni-Ti alloy also in presence of stress-induced martensite. J Biomed Mater Res 2000;51:47-54.
    • (2000) J Biomed Mater Res , vol.51 , pp. 47-54
    • Rondelli, G.1    Vicentini, B.2
  • 36
    • 0346124163 scopus 로고    scopus 로고
    • Corrosion resistance of stressed NiTi and stainless steel orthodontic wires in acid artificial saliva
    • Huang HH. Corrosion resistance of stressed NiTi and stainless steel orthodontic wires in acid artificial saliva. J Biomed Mater Res A 2003;66:829-839.
    • (2003) J Biomed Mater Res A , vol.66 , pp. 829-839
    • Huang, H.H.1
  • 38
    • 2642542574 scopus 로고    scopus 로고
    • Effect of constituent phase of Ni-Ti shape memory alloy on susceptibility to hydrogen embrittlement
    • Yokoyama K, Eguchi T, Asaoka K, Nagumo M. Effect of constituent phase of Ni-Ti shape memory alloy on susceptibility to hydrogen embrittlement. Mater Sci Eng A 2004;374:177-183.
    • (2004) Mater Sci Eng A , vol.374 , pp. 177-183
    • Yokoyama, K.1    Eguchi, T.2    Asaoka, K.3    Nagumo, M.4
  • 39
    • 0026879344 scopus 로고
    • Microanalytical characterization and surface modification of TiNi orthodontic archwires
    • Oshida Y, Sachdeva RCL, Miyazaki S. Microanalytical characterization and surface modification of TiNi orthodontic archwires. Biomed Mater Eng 1992;2:51-69.
    • (1992) Biomed Mater Eng , vol.2 , pp. 51-69
    • Oshida, Y.1    Sachdeva, R.C.L.2    Miyazaki, S.3
  • 41
    • 0025192709 scopus 로고
    • The corrosion behaviour of nickel titanium shape memory alloys
    • Rondelli G, Vicentini B, Cigada A. The corrosion behaviour of nickel titanium shape memory alloys. Corros Sci 1990;30:805-812.
    • (1990) Corros Sci , vol.30 , pp. 805-812
    • Rondelli, G.1    Vicentini, B.2    Cigada, A.3
  • 42
    • 84956040351 scopus 로고
    • Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants
    • Shabalovskaya SA, Anderegg JW. Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants. J Vac Sci Technol A 1995;13:2624-2632.
    • (1995) J Vac Sci Technol A , vol.13 , pp. 2624-2632
    • Shabalovskaya, S.A.1    Anderegg, J.W.2
  • 43
    • 0035875976 scopus 로고    scopus 로고
    • Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials
    • Aziz-Kerrzo M, Conroy KG, Fenelon AM, Farrell ST, Breslin CB. Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials. Biomaterials 2001;22:1531-1539.
    • (2001) Biomaterials , vol.22 , pp. 1531-1539
    • Aziz-Kerrzo, M.1    Conroy, K.G.2    Fenelon, A.M.3    Farrell, S.T.4    Breslin, C.B.5
  • 44
    • 33644845524 scopus 로고    scopus 로고
    • Fabrication and characteristics of bioactive sodium titanate/titania graded film on NiTi shape memory alloy
    • Chu CL, Chung CY, Zhou J, Pu YP, Lin PH. Fabrication and characteristics of bioactive sodium titanate/titania graded film on NiTi shape memory alloy. J Biomed Mater Res A 2005;75:595-602.
    • (2005) J Biomed Mater Res A , vol.75 , pp. 595-602
    • Chu, C.L.1    Chung, C.Y.2    Zhou, J.3    Pu, Y.P.4    Lin, P.H.5
  • 45
    • 30944434044 scopus 로고    scopus 로고
    • Surface oxidation of NiTi shape memory alloy in a boiling aqueous solution containing hydrogen peroxide
    • Chu CL, Chung CY, Chu PK. Surface oxidation of NiTi shape memory alloy in a boiling aqueous solution containing hydrogen peroxide. Mater Sci Eng A 2006;417:104-109.
    • (2006) Mater Sci Eng A , vol.417 , pp. 104-109
    • Chu, C.L.1    Chung, C.Y.2    Chu, P.K.3
  • 46
    • 0027168664 scopus 로고
    • 2-treated titanium surfaces in contact with blood plasma and a simulated body fluid
    • 2-treated titanium surfaces in contact with blood plasma and a simulated body fluid. Clin Mater 1993;12:141-148.
    • (1993) Clin Mater , vol.12 , pp. 141-148
    • Wälivaara, B.1    Lundström, I.2    Tengvall, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.